LTM4680IY

LTM4680IY

  • 厂商:

    AD(亚德诺)

  • 封装:

    BGA-144

  • 描述:

    LTM4680IY

  • 数据手册
  • 价格&库存
LTM4680IY 数据手册
LTM4680 Dual 30A or Single 60A µModule Regulator with Digital Power System Management FEATURES DESCRIPTION Dual 30A or Single 60A Digitally Adjustable Analog Loops with Digital Interface for Control and Monitoring nn Wide Input Voltage Range: 4.5V to 16V nn Output Voltage Range: 0.5V to 3.3V nn 90% Full Load Efficiency from 12V to 1V IN OUT at 60A nn ±0.5% Maximum DC Output Error Over Temperature nn ±2.5% Current Readback Accuracy (25°C to 125°C) nn Integrated Input Current Sense Amplifier nn 400kHz PMBus-Compliant I2C Serial Interface nn Supports Telemetry Polling Rates up to 125Hz nn Constant Frequency Current Mode Control nn Parallel and Current Share Multiple Modules nn Pin Compatible with LTM4678 nn 16mm × 16mm × 7.82mm BGA Package Readable Data: nn Input and Output Voltages, Currents, and Temperatures nn Running Peak Values, Uptime, Faults and Warnings nn Onboard EEPROM Fault Log Record Writable Data and Configurable Parameters: nn Output Voltage, Voltage Sequencing and Margining nn Digital Soft-Start/Stop Ramp, Program Analog Loop nn OV/UV/OT, UVLO, Frequency and Phasing The LTM®4680 is a dual 30A or single 60A step-down µModule® (power module) DC/DC regulator featuring remote configurability and telemetry-monitoring of power management parameters over PMBus—an open standard I2C-based digital interface protocol. The LTM4680 is comprised of digitally programmable analog control loops, precision mixed-signal circuitry, EEPROM, power MOSFETs, inductors and supporting components. nn APPLICATIONS nn System Optimization, Characterization and Data Mining in Prototype, Production and Field Environments The LTM4680 product video is available on the website. The LTM4680’s 2-wire serial interface allows outputs to be margined, tuned and ramped up and down at programmable slew rates with sequencing delay times. True input current sense, output currents and voltages, output power, temperatures, uptime and peak values are readable. Custom configuration of the EEPROM contents is not required. At start-up, output voltages, switching frequency, and channel phase angle assignments can be set by pinstrapping resistors. The LTpowerPlay® GUI and DC1613 USB-to-PMBus converter and demo kits are available. The LTM4680 is offered in a 16mm × 16mm × 7.82mm BGA package available with SnPb or RoHS compliant terminal finish. Pin compatible with LTM4678. All registered trademarks and trademarks are the property of their respective owners. Protected by U.S. Patents including 5408150, 5481178, 5705919, 5929620, 6144194, 6177787, 6580258, 7420359, 8163643. Licensed under U.S. Patent 7000125 and other related patents worldwide. Click to view associated Video Design Idea. TYPICAL APPLICATION Dual 30A µModule Regulator with Digital Interface for Control and Monitoring* 22µF ×5 IN+ VOSNS0+ RSENSE ON/OFF CONTROL FAULT INTERRUPTS SYNCHRONIZATION TIME-BASE REGISTER WRITE PROTECTION IN– VIN1 VIN0 SVIN RUN1 VOSNS0– LTM4680 VOSNS1+ LOAD1 VOSNS1– FAULT1 SYNC SHARE_CLK *FOR COMPLETE CIRCUIT, SEE FIGURE 46 LOAD0 VOUT1 RUN0 FAULT0 WP VOUT0 ADJUSTABLE UP TO 30A VOUT0 SCL SDA ALERT SGND GND 100µF ×8 VOUT1 ADJUSTABLE UP TO 30A 100µF ×8 I2C/SMBus I/F WITH PMBus COMMAND SET TO/FROM IPMI OR OTHER BOARD MANAGEMENT CONTROLLER 4680 TA01a 95 90 EFFICIENCY (%) 4.5V to 16V (FROM 4.5V TO 5.75V, CONNECT VIN, SVIN AND INTVCC TOGETHER) Efficiency vs Current at 12V Input 100 85 80 75 70 65 1.0V, 250kHz 1.5V, 425kHz 0 5 10 15 20 LOAD CURRENT (A) 25 30 4680 TA01b Rev. B Document Feedback For more information www.analog.com 1 LTM4680 TABLE OF CONTENTS Features...................................................... 1 Applications................................................. 1 Typical Application ......................................... 1 Description.................................................. 1 Table of Contents........................................... 2 Absolute Maximum Ratings............................... 4 Order Information........................................... 4 Pin Configuration........................................... 4 Electrical Characteristics.................................. 5 Typical Performance Characteristics................... 12 Pin Functions............................................... 15 Simplified Block Diagram................................ 19 Decoupling Requirements................................ 19 Functional Diagram....................................... 20 Test Circuits................................................ 21 Operation................................................... 23 Power Module Introduction ....................................23 Power Module Overview, Major Features.................23 EEPROM with ECC .................................................. 24 Power-Up and Initialization .....................................25 Soft-Start ................................................................26 Time-Based Sequencing .........................................26 Voltage-Based Sequencing .....................................26 Shutdown ............................................................... 27 Light-Load Current Operation ................................. 27 Switching Frequency and Phase.............................. 28 PWM Loop Compensation ...................................... 28 Output Voltage Sensing .......................................... 28 INTVCC/EXTVCC Power ........................................... 28 Output Current Sensing and Sub Milliohm DCR Current Sensing ..............................................29 Input Current Sensing .............................................29 PolyPhase Load Sharing .........................................29 External/Internal Temperature Sense ......................30 RCONFIG (Resistor Configuration) Pins ..................30 Table 1. VOUTn_CFG Pin Strapping Look-Up Table for the LTM4680’s Output Voltage, Coarse Setting (Not Applicable if MFR_CONFIG_ALL[6] = 1b)..............31 Table 2. VTRIMn_CFG Pin Strapping Look-Up Table for the LTM4680’s Output Voltage, Fine Adjustment Setting (Not Applicable if MFR_ CONFIG_ALL[6] = 1b) ......................................... 31 2 Table 3. FSWPH_CFG Pin Strapping Look-Up Table to Set the LTM4680’s Switching Frequency and Channel Phase-Interleaving Angle (Not Applicable if MFR_CONFIG_ALL[6] = 1b) ............................ 32 Table 4. ASEL Pin Strapping Look-Up Table to Set the LTM4680’s Slave Address (Applicable Regardless of MFR_CONFIG_ALL[6] Setting) .....33 Table 5. LTM4680 MFR_ADDRESS Command Examples Expressed in 7- and 8-Bit Addressing ..... 33 Fault Detection and Handling ..................................33 Status Registers and ALERT Masking ...................34 Figure 5. LTM4680 Status Register Summary.......35 Mapping Faults to FAULT Pins ..............................36 Power Good Pins ..................................................36 CRC Protection .....................................................36 Serial Interface .......................................................36 Communication Protection ...................................36 Device Addressing ..................................................36 Responses to VOUT and IIN/IOUT Faults ................... 37 Output Overvoltage Fault Response ..................... 37 Output Undervoltage Response ............................38 Peak Output Overcurrent Fault Response .............38 Responses to Timing Faults ....................................38 Responses to VIN OV Faults ....................................38 Responses to OT/UT Faults .....................................38 Internal Overtemperature Fault Response ............38 External Overtemperature and Undertemperature Fault Response .....................39 Responses to Input Overcurrent and Output Undercurrent Faults ................................................39 Responses to External Faults .................................. 39 Fault Logging .......................................................... 39 Bus Timeout Protection .......................................... 39 Similarity Between PMBus, SMBus and I2C 2-Wire Interface ......................................................40 PMBus Serial Digital Interface ................................40 Table 6. Abbreviations of Supported Data Formats ....41 Figure 6. PMBus Timing Diagram.......................... 41 Figures 7 to 24 PMBus Protocols............................ 42 Rev. B For more information www.analog.com LTM4680 TABLE OF CONTENTS PMBus Command Summary............................. 45 PMBus Commands .................................................45 Table 7. PMBus Commands Summary (Note: The Data Format Abbreviations Are Detailed in Table 8) ............................................................45 Table 8. Data Format Abbreviations ......................50 Applications Information................................. 51 VIN to VOUT Step-Down Ratios ................................ 51 Input Capacitors ..................................................... 51 Output Capacitors ................................................... 51 Light Load Current Operation.................................. 51 Switching Frequency and Phase ............................. 52 Output Current Limit Programming ........................53 Minimum On-Time Considerations .........................54 Variable Delay Time, Soft-Start and Output Voltage Ramping ....................................................54 Digital Servo Mode .................................................54 Soft Off (Sequenced Off) ........................................55 Undervoltage Lockout .............................................56 Fault Detection and Handling ..................................56 Open-Drain Pins .....................................................56 Phase-Locked Loop and Frequency Synchronization .. 57 Input Current Sense Amplifier .................................58 Programmable Loop Compensation .......................58 Checking Transient Response ................................. 59 PolyPhase Configuration ......................................60 Connecting The USB to I2C/SMBus/PMBus Controller to the LTM4680 In System .....................60 LTpowerPlay: An Interactive GUI for Digital Power........ 61 PMBus Communication and Command Processing .............................................................. 61 Thermal Considerations and Output Current Derating ...................................................63 Tables 10 thru 11: Output Current Derating............66 Table 12. Channel Output Voltage vs Capacitor Selection, All Ceramic Configuration, 15A to 30A Load Step with 15A/µs Slew Rate .......................66 Table 13. Channel Output Voltage vs Capacitor Selection, Bulk and Ceramic Cap Configuration, 15A to 30A Load Step with 15A/µs Slew Rate .... 67 Table 14. Dual Phase Single Output Voltage vs Capacitor Selection, Bulk and Ceramic Cap Configuration, 30A to 60A Load Step with 30A/µs Slew Rate ...........................................................68 Derating Curves.......................................................69 EMI Performance .................................................... 70 Safety Considerations ............................................. 70 Layout Checklist/Example ...................................... 70 Typical Applications....................................... 72 PMBus Command Details................................ 77 Addressing and Write Protect..................................77 General Configuration Commands........................... 79 On/Off/Margin.........................................................80 PWM Configuration................................................. 82 Voltage.....................................................................85 Input Voltage and Limits........................................85 Output Voltage and Limits.....................................86 Output Current and Limits.......................................89 Input Current and Limits ....................................... 91 Temperature.............................................................92 Power Stage DCR Temperature Calibration...........92 Timing.....................................................................93 Timing—On Sequence/Ramp................................93 Timing—Off Sequence/Ramp...............................94 Precondition for Restart........................................95 Fault Response........................................................95 Fault Responses All Faults.....................................95 Fault Responses Input Voltage..............................96 Fault Responses Output Voltage............................96 Fault Responses Output Current............................99 Fault Responses IC Temperature......................... 100 Fault Responses External Temperature................ 101 Fault Sharing.......................................................... 102 Fault Sharing Propagation................................... 102 Fault Sharing Response....................................... 104 Scratchpad............................................................ 104 Identification.......................................................... 105 Fault Warning and Status....................................... 106 Telemetry............................................................... 113 NVM Memory Commands..................................... 117 Store/Restore...................................................... 117 Fault Logging....................................................... 118 Block Memory Write/Read................................... 122 Package Description.................................... 123 Table 23. LTM4680 BGA Pinout........................... 123 Revision History......................................... 125 Package Photograph.................................... 126 Design Resources....................................... 126 Related Parts............................................. 126 Rev. B For more information www.analog.com 3 LTM4680 ABSOLUTE MAXIMUM RATINGS PIN CONFIGURATION (Note 1) Terminal Voltages: VINn (Note 4), SVIN, IIN+, IIN−....................... –0.3V to 18V (SVIN – IIN+), (IIN+ – IIN−)............................ –0.3V to 0.3V SW0, SW1................... −1V to 18V, −5V to 18V Transient INTVCC, EXTVCC........................................... –0.3V to 6V VOUTn......................................................... –0.3V to 3.6V VOSNS0+, VOSNS1+.......................................... –0.3V to 6V VOSNS0−, VOSNS1−....................................... –0.3V to 0.3V RUNn, SDA, SCL, ALERT............................ –0.3V to 5.5V FSWPH_CFG, VOUT0,1_CFG, VTRIM0,1_CFG, ASEL.......................... –0.3V to 2.75V FAULTn, SYNC, SHARE_CLK, WP, PGOOD0, PGOOD1................................ −0.3V to 3.6V COMPna, COMPnb, ................................... –0.3V to 2.7V TSNS0a, TSNS1a....................................... –0.3V to 2.2V TSNS0b, TSNS1b....................................... –0.3V to 0.8V Temperatures Internal Operating Temperature Range (Notes 2, 13, 16, 17)............................... –40°C to 125°C Storage Temperature Range................... –55°C to 125°C Peak Solder Reflow Package Body Temperature.... 245°C (Not recommended for upside down reflow.) TOP VIEW VOSNS1+ VOSNS1– A VOUT1 GND SW1 B VOUT1 COMP1b C D VTRIM0_ CFG SHARE VDD25 TSNS1b PGOOD1 COMP1a CLK GND SVIN WP GND INTVCC VDD33 E VIN1 FSWPH_ VTRIM1_ VOUT0_ VOUT1_ CFG CFG EXTVCC F SGND GND G VIN0 COMP0b SDA CFG CFG RUN1 ASEL FAULT1 RUN0 ALERT FAULT0 H IIN+ PGOOD0 TSNS0b COMP0a TSNS1a TSNS0a SCL J IIN– GND SYNC K VOUT0 GND L VOUT0 SW0 VOSNS0+ VOSNS0– M 1 2 3 4 5 6 7 8 9 10 11 12 BGA PACKAGE 144-LEAD (16mm × 16mm × 7.82mm) TJMAX = 125°C, θJCtop = 3.3°C/W, θJCbottom = 2°C/W, θJB = 2°C/W, θJA = 7°C/W WEIGHT = 7.4 GRAMS ORDER INFORMATION PART MARKING* PART NUMBER LTM4680EY#PBF LTM4680IY#PBF LTM4680IY PAD OR BALL FINISH SAC305 (RoHS) SnPb (63/37) DEVICE LTM4680Y LTM4680Y LTM4680Y Contact the factory for parts specified with wider operating temperature ranges. *Device temperature grade is indicated by a label on the shipping container. Pad or ball finish code is per IPC/JEDEC J-STD-609. 4 FINISH CODE PACKAGE TYPE MSL RATING BGA 4 e1 TEMPERATURE RANGE (See Note 2) –40°C to 125°C e0 • Recommended LGA and BGA PCB Assembly and Manufacturing Procedures • LGA and BGA Package and Tray Drawings Rev. B For more information www.analog.com LTM4680 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the specified internal operating temperature range (Note 2). n is specified as each individual output channel (Note 4). TA = 25°C, VIN = 12V, RUNn = 3.3V, EXTVCC = 0, FREQUENCY_SWITCH = 350kHz and VOUTn commanded to 1.000V unless otherwise noted. Configured with factory-default EEPROM settings and per Test Circuit 1, unless otherwise noted. SYMBOL PARAMETER CONDITIONS VIN Input DC Voltage Test Circuit 1 Test Circuit 2; VIN_OFF < VIN_ON = 4V VOUTn Range of Output Voltage Regulation VOUTn Differentially Sensed on VOSNSn+/VOSNSn– Pin-Pair; Commanded by Serial Bus or with Resistors Present at Start-Up on VOUTn_CFG VOUTn(DC) Output Voltage, Total Variation with Line and Load Digital Servo Engaged (MFR_PWM_MODEn[6] = 1b) Digital Servo Disengaged (MFR_PWM_MODEn[6] = 0b) VOUTn Commanded to 1.000V, VOUTn Low Range (MFR_PWM_MODEn[1] = 1b) (Note 5) VUVLO Undervoltage Lockout Threshold, When VIN < 4.3V VINTVCC Falling VINTVCC Rising MAX UNITS l l 5.75 4.5 MIN TYP 16 5.75 V V l 0.5 3.34 V l 0.995 1.000 1.005 0.985 1.000 1.015 V V 3.55 3.90 V V Input Specifications IINRUSH(VIN) Input Inrush Current at Start-Up Test Circuit 1, VOUTn =1V, VIN = 12V; No Load Besides Capacitors; TON_RISEn = 3ms (Note 12) IQ(SVIN) Input Supply Bias Current Forced Continuous Mode, MFR_PWM_MODEn[0] = 1b RUNn = 3.3V Shutdown, RUN0 = RUN1 = 0V IS(VINn,DCM) Input Supply Current in Discontinuous Mode Operation Discontinuous Mode, MFR_PWM_MODEn[0] = 0b, IOUTn = 100mA IS(VINn,FCM) Input Supply Current in ForcedContinuous Mode Operation Forced Continuous Mode, MFR_PWM_MODEn[0] = 1b VINn = 12V, VOUTn = 1V IOUTn = 30A 50 mA 37 25 mA mA 20 mA 3.2 A Output Specifications IOUTn Output Continuous Current Range Utilizing MFR_PWM_MODE[7] = 1 for IOUT_OC_FAULT_ LIMIT, Page 90 (Note 6) ∆VOUTn(LINE) Line Regulation Accuracy Digital Servo Engaged (MFR_PWM_MODEn[6] = 1b) Digital Servo Disengaged (MFR_PWM_MODEn[6] = 0b) SVIN and VINn Electrically Shorted Together and INTVCC Open Circuit; IOUTn = 0A, 5.75V ≤ VIN ≤ 16V, VOUT Low Range (MFR_PWM_MODEn[1] = 1b), FREQUENCY_SWITCH = 350kHz (Note 5) VOUTn ∆VOUTn(LOAD) Load Regulation Accuracy VOUTn VOUTn(AC) Digital Servo Engaged (MFR_PWM_MODEn[6] = 1b) Digital Servo Disengaged (MFR_PWM_MODEn[6] = 0b) 0A ≤ IOUTn ≤ 30A, VOUTn Low Range, (MFR_PWM_ MODEn[1] = 1b) (Note 5) 0 30 A l 0.03 0.03 ±0.2 %/V %/V l 0.03 0.2 0.5 % % Output Voltage Ripple 10 fS (Each Channel) VOUTn Ripple Frequency FREQUENCY_SWITCH Set to 350kHz (0xFABC) ∆VOUTn(START) Turn-On Overshoot TON_RISEn = 3ms (Note 12) tSTART Turn-On Start-Up Time Time from VIN Toggling from 0V to 12V to Rising Edge PGOODn. TON_DELAYn = 0ms, TON_RISEn = 3ms l tDELAY(0ms) Turn-On Delay Time Time from First Rising Edge of RUNn to Rising Edge of PGOODn . TON_DELAYn = 0ms, TON_RISEn = 3ms, VIN Having Been Established for at Least 70ms l ∆VOUTn(LS) Peak Output Voltage Deviation for Dynamic Load Step Load: 0A to 15A and 15A to 0A at 15A/µs, VOUTn = 1V, VIN = 12V (Note 12) See Transient Graph tSETTLE Settling Time for Dynamic Load Step Load: 0A to 15A and 15A to 0A at 15A/µs, VOUTn = 1V, VIN = 12V (Note 12) See Transient Graphs l 320 2.75 350 mVP-P 370 kHz 8 mV 30 ms 3.1 3.8 ms 60 mV 50 µs Rev. B For more information www.analog.com 5 LTM4680 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the specified internal operating temperature range (Note 2). n is specified as each individual output channel (Note 4). TA = 25°C, VIN = 12V, RUNn = 3.3V, EXTVCC = 0, FREQUENCY_SWITCH = 350kHz and VOUTn commanded to 1.000V unless otherwise noted. Configured with factory-default EEPROM settings and per Test Circuit 1, unless otherwise noted. SYMBOL PARAMETER CONDITIONS IOUTn(OCL_AVG) Output Current Limit, Time Averaged, Readback Time-Averaged Output Inductor Current Limit Inception Threshold, Commanded by IOUT_OC_FAULT_LIMITn (Note 12) Utilizing MFR_PWM_MODE[7] = 0, Using IL PEAK = 40A, Page  90 VFBCMn Feedback Input Common Mode Range VOSNSn– Valid Input Range (Referred to SGND) VOSNSn+ Valid Input Range (Referred to SGND) VOUT-RNGL Full-Scale Command Voltage, Range VOUTn Commanded to 2.750V, MFR_PWM_MODEn[1] = 1b Low (0.5V to 2.75V) (Notes 7, 15) Set Point Accuracy Resolution LSB Step Size MIN TYP MAX 39 UNITS A Control Section VOUT-RNGH l l Full-Scale Command Voltage, Range VOUTn Commanded to 3.6V, MFR_PWM_MODEn[1] = 0b High (0.5V to 3.6V) Limit Design to 3.6V Operating for Module Set Point Accuracy (Notes 7, 15) Resolution LSB Step Size –0.1 0.3 3.6 2.75 −0.5 12 0.688 V 0.5 3.6 –0.5 12 1.375 V V % Bits mV V 0.5 % Bits mV RVSNS0+ VOSNS0+ Impedance to SGND 0.05V ≤ VVOSNS0+ – VSGND ≤ 3.3V 50 kΩ RVSNS1+ VOSNS1+ Impedance to SGND 0.05V ≤ VVOSNS1+ – VSGND ≤ 3.3V 50 kΩ tON(MIN) Minimum On-Time (Note 8 ) 60 ns RCOMP0,1 Resolution Compensation Resistor RTH(MAX) Compensation Resistor RTH(MIN) MFR_PWM_CONFIG[4:0] = 0 to 31 (See Figure 1) 5 62 0.5 Bits kΩ kΩ gm0,1 Resolution Error Amplifier gm(MAX) Error Amplifier gm(MIN) LSB Step Size COMP0,1 = 1.35V, MFR_PWM_CONFIG[7:5] = 0 to 7 3 5.76 1 0.68 Bits mmho mmho mmho Analog OV/UV (Overvoltage/Undervoltage) Output Voltage Supervisor Comparators (VOUT_OV/UV_FAULT_LIMIT and VOUT_OV/UV_WARN_LIMIT Monitors) NOV/UV_COMP Resolution, Output Voltage Supervisors (Note 15) VOV-RNG Output OV Comparator Threshold Detection Range (Note 15) High Range Scale, MFR_PWM_MODEn[1] = 0b Low Range Scale, MFR_PWM_MODEn[1] = 1b VOUSTP Output OV and UV Comparator Threshold Programming LSB Step Size (Note 15) High Range Scale, MFR_PWM_MODEn[1] = 0b Low Range Scale, MFR_PWM_MODEn[1] = 1b VOUT-RNGH Full-Scale Command Voltage, Range VOUTn Commanded to 3.6V, MFR_PWM_MODEn[1] = 0b High (0.5V to 3.6V) (Notes 7, 15) Set Point Accuracy Resolution LSB Step Size VOV-ACC-n Output OV Comparator Threshold Accuracy Channel 0 and 1 2V ≤ VVOSNSn+ – VVOSNSn– ≤ 3.6V, MFR_PWM_MODEn[1] = 0b l 0.5V ≤ VVOSNSn+ – VVOSNSn– < 2.7V, MFR_PWM_MODEn[1] = 1b l (Note 14) VUV-RNG Output UV Comparator Threshold Detection Range High Range Scale, MFR_PWM_MODEn[1] = 0b Low Range Scale, MFR_PWM_MODEn[1] = 1b (Note 15) 6 9 1 0.5 Bits 3.6 2.7 11.2 5.6 3.5 –0.5 1 0.5 12 1.375 V V mV mV 3.7 V –0.5 % Bits mV ±1.5 ±40 % mV 3.6 2.7 V V Rev. B For more information www.analog.com LTM4680 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the specified internal operating temperature range (Note 2). n is specified as each individual output channel (Note 4). TA = 25°C, VIN = 12V, RUNn = 3.3V, EXTVCC = 0, FREQUENCY_SWITCH = 350kHz and VOUTn commanded to 1.000V unless otherwise noted. Configured with factory-default EEPROM settings and per Test Circuit 1, unless otherwise noted. SYMBOL PARAMETER CONDITIONS VUV-ACC-n Output UV Comparator Threshold Accuracy 2V ≤ VVSNSn+ – VVSNSn– ≤ 3.6V, MFR_PWM_MODEn[1] = 0b 0.5V ≤ VVSNSn+ – VVSNSn– < 2.7V, MFR_PWM_MODEn[1] = 1b tPROP-OV Output OV Comparator Response Times tPROP-UV Output UV Comparator Response Times MIN TYP MAX UNITS ±1.5 ±40 % mV Overdrive to 10% Above Programmed Threshold 100 µs Under Drive to 10% Below Programmed Threshold 100 µs l l (Note 14) Analog OV/UV SVIN Input Voltage Supervisor Comparators (Threshold Detectors for VIN_ON and VIN_OFF) NSVIN-OV/UV-COMP SVIN OV/UV Comparator ThresholdProgramming Resolution (Notes 14, 15) 9 SVIN-OU-RANGE SVIN OV/UV Comparator ThresholdProgramming Range Limited to Abs Max = 18V for LTM4680 Module SVIN-OU-STP SVIN OV/UV Comparator ThresholdProgramming LSB Step Size (Note 15) SVIN-OU-ACC SVIN OV/UV Comparator Threshold Accuracy 4.5V < SVIN ≤ 16V l ±350 mV tPROP-SVIN-HIGH-VIN SVIN OV/UV Comparator Response Time, High VIN Operating Configuration Test Circuit 1, and: VIN_ON = 9V; SVIN Driven from 8.775V to 9.225V VIN_OFF = 9V; SVIN Driven from 9.225V to 8.775V l l 100 100 µs µs tPROP-SVIN-LOW-VIN SVIN OV/UV Comparator Response Time, Low VIN Operating Configuration Test Circuit 2, and: VIN_ON = 4.5V; SVIN Driven from 4.225V to 4.725V VIN_OFF = 4.5V; SVIN Driven from 4.725V to 4.225V l l 100 100 µs µs 4.5 Bits 18 V 76 mV Channels 0 and 1 Output Voltage Readback (READ_VOUTn) NVO-RB Output Voltage Readback Resolution (Note 15) and LSB Step Size VO-F/S Output Voltage Full-Scale Digitizable Range VRUNn = 0V (Note 15), Limited to 3.6V Max Operating VO-RB-ACC-n Output Voltage Readback Accuracy 1V ≤ VVOSNSn+ – VVOSNSn– ≤ 3.3V 0.5V ≤ VVOSNSn+ – VVOSNSn– < 1V tCONVERT-VO-RB Output Voltage Readback Update Rate MFR_ADC_CONTROL = 0x00 (Notes 9, 15) MFR_ADC_CONTROL = 0x01 through 0x0C (Notes 9, 15) MFR_ADC_CONTROL Section 16 244 Bits µV 8 l l V Within ±0.5% of Reading Within ±5mV of Reading 90 8 ms ms ms 10 15.625 Bits mV Input Voltage (SVIN) Readback (READ_VIN) NSVIN-RB Input Voltage Readback Resolution and LSB Step Size (Notes 11, 15) Limited to Abs Max = 18V for LTM4680 Module SVIN-F/S Input Voltage Full-Scale Digitizable Range (Notes 11, 15) SVIN-RB-ACC Input Voltage Readback Accuracy READ_VIN, 4.5V ≤ SVIN ≤ 16V tCONVERT-SVIN-RB Input Voltage Readback Update Rate MFR_ADC_CONTROL = 0x00 (Notes 9, 15) MFR_ADC_CONTROL = 0x01 (Notes 9, 15) 43 l V Within ±2% of Reading 90 8 ms ms Channels 0 and 1 Output Current (READ_IOUTn), Duty Cycle (READ_DUTY_CYCLEn), and Computed Input Current (MFR_READ_IINn) Readback NIO-RB Output Current Readback Resolution (Note 15) and LSB Step Size IO-F/S Output Current Full-Scale Digitizable Range (Note 15) Utilizing MFR_PWM_MODE[7] = 0b, Using IOUT_OC_FAULT_LIMIT = 40A, Page 90 10 34.1 30 Bits mA A Rev. B For more information www.analog.com 7 LTM4680 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the specified internal operating temperature range (Note 2). n is specified as each individual output channel (Note 4). TA = 25°C, VIN = 12V, RUNn = 3.3V, EXTVCC = 0, FREQUENCY_SWITCH = 350kHz and VOUTn commanded to 1.000V unless otherwise noted. Configured with factory-default EEPROM settings and per Test Circuit 1, unless otherwise noted. SYMBOL PARAMETER CONDITIONS IO-RB-ACC Output Current, Readback Accuracy READ_IOUTn, Channels 0 and 1, 0 ≤ IOUTn ≤ 30A, Forced-Continuous Mode, MFR_PWM_MODEn[0] = 1b 25°C to 125°C l –40°C to 125°C See Histograms in Typical Performance Characteristic, (Note 12). MIN TYP MAX UNITS Within 0.75A of Reading Within 1.5A of Reading IO-RB(30A) Full Load Output Current Readback IOUTn = 30A (Note 12). See Histograms in Typical Performance Characteristics 30 A tCONVERT-IO-RB Output Current Readback Update Rate MFR_ADC_CONTROL = 0x00 (Notes 9, 15) MFR_ADC_CONTROL = 0x06 (CH0 IOUT) or 0x0A (CH1 IOUT) (Notes 9, 15) See MFR_ADC_CONTROL Section 90 8 ms ms Resolution (Note 15) 10 Bits VIINSTP LSB Step Size Full-Scale Range = 16mV LSB Step Size Full-Scale Range = 32mV LSB Step Size Full-Scale Range = 64mV 15.26 30.52 61 µV µV µV IIN_TUE Total Unadjusted Error Gain = 8, 0V ≤ |VIIN+ – VIIN–| ≤ 5mV Gain = 4, 0V ≤ |VIIN+ – VIIN–| ≤ 20mV Gain = 2, 0V ≤ |VIIN+ – VIIN–| ≤ 50mV Gain = 8, 2.5mV ≤ |VIIN+ – VIIN–| (Note 14) Gain = 4, 4mV ≤ |VIIN+ – VIIN–| (Note 14) Gain = 2, 6mV ≤ |VIIN+ – VIIN–| (Note 14) VOS Zero-Code Offset Voltage (Note 15) tCONVERT Update Rate (Notes 9,15) See MFR_ADC_CONTROL Section for Faster Update Rates 90 ms Input Current Readback N ±2 ±1.3 ±1.2 l l l ±50 % % % µV Supply Current Readback N Resolution (Note 15) 10 Bits VICHIPSTP LSB Step Size Full-Scale Range = 256mV Onboard 1Ω Resistor 244 µV ICHIP_RB ICHIP Readback SVIN Current ±50 mA tCONVERT Update Rate (Notes 9,15) See MFR_ADC_CONTROL Section for Faster Update Rates 90 ms 0.25 °C ±2.5 °C Temperature Readback (T0, T1) TRES-RB Temperature Readback Resolution Channel 0, Channel 1, and Controller (Note 15) T0_TUE External Temperature Total Unadjusted Readback Error Supporting Only ΔVBE Sensing T1_TUE Internal TSNS TUE VRUN0,1 = 0.0, fSYNC = 0kHz (Note 14) ±1 °C tCONVERT Update Rate MFR_ADC_CONTROL = 0x00 (Notes 9, 15) MFR_ADC_CONTROL = 0x04 or 0x0C (Notes 9, 15) 90 8 ms ms INTVCC Regulator/EXTVCC VINTVCC Internal VCC Voltage No Load 6V ≤ VIN ≤ 16V VLDO_INT INTVCC Load Regulation ICC = 0mA to 20mA, 6V ≤ VIN ≤ 16V VEXTVCC EXTVCC Switchover Voltage VIN ≥ 7V, EXTVCC Rising VLDO_HYS EXTVCC Hysteresis VLDO_EXT EXTVCC Voltage Drop ICC = 20mA, VEXTVCC = 5.5V 70 VIN_THR VIN Threshold to Enable EXTVCC Switchover VIN Rising 7 V VIN_THF VIN Threshold to Disable EXTVCC Switchover VIN Falling 6.5 V 8 5.25 4.5 5.5 5.75 V 0.5 ±2 % 4.7 V 300 mV 120 mV Rev. B For more information www.analog.com LTM4680 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the specified internal operating temperature range (Note 2). n is specified as each individual output channel (Note 4). TA = 25°C, VIN = 12V, RUNn = 3.3V, EXTVCC = 0, FREQUENCY_SWITCH = 350kHz and VOUTn commanded to 1.000V unless otherwise noted. Configured with factory-default EEPROM settings and per Test Circuit 1, unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN VVDD33 Internal VDD33 Voltage 4.5V < VINTVCC or 4.8V < VEXTVCC 3.2 ILIM VDD33 Current Limit VDD33 = GND, VIN = INTVCC = 4.5V VVDD33_OV VVDD33_UV TYP MAX 3.3 3.4 UNITS VDD33 Regulator V 100 mA VDD33 Overvoltage Threshold 3.5 V VDD33 Undervoltage Threshold 3.1 V VDD25 Regulator VVDD25 Internal VDD25 Voltage ILIM VDD25 Current Limit VDD25 = GND, VIN = INTVCC = 4.5V 2.5 V 80 mA Oscillator and Phase-Locked Loop (PLL) fRANGE PLL SYNC Range Synchronized with Falling Edge of SYNC l fOSC Oscillator Frequency Accuracy Frequency Switch = 250.0 to 1000.0 kHz (Note 15) l 300 1000 kHz ±7.5 % VTH(SYNC) SYNC Input Threshold VSYNC Falling VSYNC Rising 1 1.5 VOL(SYNC) SYNC Low Output Voltage ILOAD = 3mA 0.2 ILEAK(SYNC) SYNC Leakage Current in Slave Mode 0V ≤ VPIN ≤ 3.6V θSYNC-θ0 SYNC to Ch0 Phase Relationship Based on the Falling Edge of Sync and Rising Edge of TG0 MFR_PWM_CONFIG[2:0] = 0,2,3 MFR_PWM_CONFIG[2:0] = 5 MFR_PWM_CONFIG[2:0] = 1 MFR_PWM_CONFIG[2:0]= 4,6 0 60 90 120 Deg Deg Deg Deg θSYNC-θ1 SYNC to Ch1 Phase Relationship Based on the Falling Edge of Sync and Rising Edge of TG1 MFR_PWM_CONFIG[2:0] = 3 MFR_PWM_CONFIG[2:0] = 0 MFR_PWM_CONFIG[2:0] = 2,4,5 MFR_PWM_CONFIG[2:0] = 1 MFR_PWM_CONFIG[2:0] = 6 120 180 240 270 300 Deg Deg Deg Deg Deg V V 0.4 ±5 V µA EEPROM Characteristics Endurance (Notes 13, 16) 0°C ≤ TJ ≤ 85°C During EEPROM Write Operations l 10,000 Retention (Notes 13, 16) TJ < 125°C l Mass_Write Mass Write Operation Time STORE_USER_ALL, 0°C < TJ < 85°C During EEPROM Write Operation Cycles 10 Years 440 4100 ms Leakage Current SDA, SCL, ALERT, RUN IOL Input Leakage Current OV ≤ VPIN ≤ 5.5V l ±5 µA OV ≤ VPIN ≤ 3.6V l ±2 µA 1.35 V Leakage Current FAULTn, PGOODn, SHARE_CLK IGL Input Leakage Current Digital Inputs SCL, SDA, RUNn, FAULTn VIH Input High Threshold Voltage l VIL Input Low Threshold Voltage l VHYST Input Hysteresis CPIN Input Capacitance SCL, SDA 0.8 V 0.08 V 10 pF Digital Input WP IPUWP Input Pull-Up Current WP 10 µA Open-Drain Outputs SCL, SDA, FAULTn, ALERT, RUNn, SHARE_CLK, PGOODn VOL Output Low Voltage ISINK = 3mA 0.4 V Rev. B For more information www.analog.com 9 LTM4680 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the specified internal operating temperature range (Note 2). n is specified as each individual output channel (Note 4). TA = 25°C, VIN = 12V, RUNn = 3.3V, EXTVCC = 0, FREQUENCY_SWITCH = 350kHz and VOUTn commanded to 1.000V unless otherwise noted. Configured with factory-default EEPROM settings and per Test Circuit 1, unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN TYP MAX 1.5 1.8 UNITS Digital Inputs SHARE_CLK, WP VIH Input High Threshold Voltage l VIL Input Low Threshold Voltage l 0.6 V 1 V 3 µs 100 µs 10 µs Digital Filtering of FAULTn IFLTG Input Digital Filtering FAULTn Digital Filtering of PGOODn IFLTG Output Digital Filtering PGOODn Digital Filtering of RUNn IFLTG Input Digital Filtering RUN PMBus Interface Timing Characteristics fSCL Serial Bus Operating Frequency l 10 tBUF Bus Free Time Between Stop and Start l 1.3 µs tHD(STA) Hold Time After Repeated Start Condition After This Period, the First Clock is Generated l 0.6 µs tSU(STA) Repeated Start Condition Setup Time l 0.6 tSU(ST0) Stop Condition Setup Time l 0.6 tHD(DAT) Date Hold Time Receiving Data Transmitting Data l l 0 0.3 tSU(DAT) Data Setup Time Receiving Data tTIMEOUT_SMB Stuck PMBus Timer Non-Block Reads Measured from the Last PMBus Start Event Stuck PMBus Timer Block Reads tLOW Serial Clock Low Period l 1.3 tHIGH Serial Clock High Period l 0.6 10000 kHz µs µs 0.9 0.1 Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The LTM4680 is tested under pulsed-load conditions such that TJ ≈ TA. The LTM4680E is guaranteed to meet performance specifications over the 0°C to 125°C internal operating temperature range. Specifications over the –40°C to 125°C internal operating temperature range are assured by design, characterization and correlation with statistical process 10 400 µs µs µs 32 255 ms 10000 µs µs controls. The LTM4680I is guaranteed to meet specifications over the full –40°C to 125°C internal operating temperature range. TJ is calculated from the ambient temperature TA and the power dissipation PD according the formula: TJ = TA + (PD • θJA) Note that the maximum ambient temperature consistent with these specifications is determined by specific operating conditions in conjunction with board layout, the rated package thermal resistance and other environmental factors. Rev. B For more information www.analog.com LTM4680 ELECTRICAL CHARACTERISTICS Note 11: The absolute maximum rating for the SVIN pin is 18V. Input voltage telemetry (READ_VIN) is obtained by digitizing a voltage scaled down from the SVIN pin. Note 12: These typical parameters are based on bench measurements and are not production tested. Note 13: EEPROM endurance and retention are guaranteed by wafer-level testing for data retention. The minimum retention specification applies for devices whose EEPROM has been cycled less than the minimum endurance specification, and whose EEPROM data was written to at 0°C ≤ TJ ≤ 85°C. The RESTORE_USER_ALL or MFR_RESET is valid over the entire operating temperature range and does not influence EEPROM characteristics. Note 14: Part tested with PWM disabled. Evaluation in application demonstrates capability. TUE(%) = ADC Gain Error (%) + 100 (zero code offset + ADC Linearity Error)/Actual Value. Note 15: Tested at IC-level ATE. Note 16: The LTM4680’s EEPROM temperature range for valid write commands is 0°C to 85°C. To achieve guaranteed EEPROM data retention, execution of the “STORE_USER_ALL” command—i.e., uploading RAM contents to NVM—outside this temperature range is not recommended. However, as long as the LTM4680’s EEPROM temperature is less than 130°C, the LTM4680 will obey the STORE_USER_ALL command. Only when EEPROM temperature exceeds 130°C, the LTM4680 will not act on any STORE_USER_ALL transactions: instead, the LTM4680 NACKs the serial command and asserts its relevant CML (communications, memory, logic) fault bits. EEPROM temperature can be queried prior to commanding STORE_USER_ALL; see the Applications Information section. Note 17: The LTM4680 includes overtemperature protection that is intended to protect the device during momentary overload conditions. Junction temperature will exceed 125°C when overtemperature protection is active. Continuous operation above the specified maximum operating junction temperature may impair device reliability. 62 56 50 43 RTH(kΩ) Note 3: All currents into device pins are positive; all currents out of device pins are negative. All voltages are referenced to ground unless otherwise specified Note 4: The two power inputs—VIN0 and VIN1—and their respective power outputs—VOUT0 and VOUT1—are tested independently in production. A shorthand notation is used in this document that allows these parameters to be referred to by “VINn” and “VOUTn”, where n is permitted to take on a value of 0 or 1. This italicized, subscripted “n ” notation and convention is extended to encompass all such pin names, as well as register names with channel-specific, i.e., paged data. For example, VOUT_COMMANDn refers to the VOUT_COMMAND command code data located in Pages 0 and 1, which in turn relate to channel 0 (VOUT0) and channel 1 (VOUT1). Registers containing non-page-specific data, i.e., whose data is “global” to the module or applies to both of the module’s channels lack the italicized, subscripted “n ”, e.g., FREQUENCY_SWITCH. Note 5: VOUTn (DC) and line and load regulation tests are performed in production with digital servo disengaged (MFR_PWM_MODEn[6] = 0b) and low VOUTn range selected MFR_PWM_MODEn[1] = 1b. The digital servo control loop is exercised in production (setting MFR_PWM_ MODEn[6] = 1b), but convergence of the output voltage to its final settling value is not necessarily observed in final test—due to potentially long time constants involved—and is instead guaranteed by the output voltage readback accuracy specification. Evaluation in application demonstrates capability; see the Typical Performance Characteristics section. Note 6: See output current derating curves for different VIN, VOUT, and TA, located in the Applications Information section. Note 7: Even though VOUT0 and VOUT1 are specified for 6V absolute maximum, the maximum recommended command voltage to regulate output channels 0 and 1 is 3.6V with VOUT range-setting bit is set using the MFR_PWM_MODEn[1] = 0b. Note 8: Minimum on-time is tested at wafer sort. Note 9: The data conversion is done by default in round robin fashion. All inputs signals are continuously converted for a typical latency of 90ms. Setting MFR_ADC_CONTRL value to be 0 to 12, LTM4680 can do fast data conversion with only 8ms to 10ms. See section PMBus Command for details. Note 10: The following telemetry parameters are formatted in PMBusdefined “Linear Data Format”, in which each register contains a word comprised of 5 most significant bits—representing a signed exponent, to be raised to the power of 2—and 11 least significant bits—representing a signed mantissa: input voltage (on SVIN), accessed via the READ_VIN command code; output currents (IOUTn), accessed via the READ_IOUTn command codes; module input current (IVIN0 + IVIN1 + ISVIN), accessed via the READ_IIN command code; channel input currents (IVINn + 1/2 • ISVIN), accessed via the MFR_READ_IINn command codes;and duty cycles of channel 0 and channel 1 switching power stages, accessed via the READ_DUTY_CYCLEn command codes. This data format limits the resolution of telemetry readback data to 10 bits even though the internal ADC is 16 bits and the LTM4680’s internal calculations use 32-bit words. 37 31 25 19 12 6 0 0 5 10 15 20 CODE 25 30 35 4680 F01 Figure 1. Programmable RCOMP Rev. B For more information www.analog.com 11 LTM4680 TYPICAL PERFORMANCE CHARACTERISTICS 100 100 95 95 90 90 EFFICIENCY (%) EFFICIENCY (%) Single Channel Efficiency, 5VIN, VIN = SVIN = EXTVCC = 5V CCM Mode 85 80 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 1.8V, 500kHz 2.5V, 575kHz 3.3V, 650kHz 75 70 65 0 5 10 15 20 LOAD CURRENT (A) 25 TA = 25°C. Single Channel Efficiency, 8VIN, VIN = SVIN = 8V, EXTVCC = 5V, CCM Mode 85 80 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 1.8V, 500kHz 2.5V, 575kHz 3.3V, 650kHz 75 70 65 30 0 5 10 15 20 LOAD CURRENT (A) 25 4680 G01 4680 G02 Dual Channel Single Output Efficiency, 12VIN, VIN = SVIN = 12V, EXTVCC = 5V, VOUT0 and VOUT1 Paralleled CCM Mode 100 100 95 95 90 90 EFFICIENCY (%) EFFICIENCY (%) Single Channel Efficiency, 12VIN, VIN = SVIN = 12V, EXTVCC = 5V CCM Mode 85 80 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 1.8V, 500kHz 2.5V, 575kHz 3.3V, 650kHz 75 70 65 0 5 10 15 20 LOAD CURRENT (A) 25 85 80 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 2.5V, 575kHz 3.3V, 650kHz 75 70 30 65 0 4680 G03 12 30 10 20 30 40 LOAD CURRENT (A) 50 60 4680 G04 Rev. B For more information www.analog.com LTM4680 TYPICAL PERFORMANCE CHARACTERISTICS Single Channel Load Transient Response 50% (15A) to 100% (30A) Load Step, 15A/µs VIN = 12V, VOUT = 0.9V, fSW = 250kHz TA = 25°C, unless otherwise noted. Single Channel Load Transient Response 50% (15A) to 100% (30A) Load Step, 15A/µs VIN = 12V, VOUT = 1.2V, fSW = 350kHz Single Channel Load Transient Response 50% (15A) to 100% (30A) Load Step, 15A/µs VIN = 12V, VOUT = 1.8V, fSW = 500kHz 50mV/DIV 50mV/DIV 50mV/DIV LOAD STEP 10A/DIV LOAD STEP 10A/DIV LOAD STEP 10A/DIV 4680 G06 100µs/DIV FIGURE 46 CIRCUIT, 12V TO 1.2V, FREQ = 350kHz COUT = 470µF ×2 POSCAP, 100µF ×4 CERAMIC RCOMP = 17k, EA-GM = 3.69ms, COMPna = 3.3nF, COMPnb = 68pF ILIM LOW, VOUT RANGE LOW 4680 G05 100µs/DIV FIGURE 46 CIRCUIT, 12V TO 0.9V, FREQ = 250kHz COUT = 470µF ×3 POSCAP, 100µF ×4 CERAMIC RCOMP = 17k, EA-GM = 3.69ms, COMPna = 3.3nF, COMPnb = 68pF ILIM LOW, VOUT RANGE LOW Single Channel Load Transient Response 50% (15A) to 100% (30A) Load Step, 15A/µs VIN = 12V, VOUT = 2.5V, fSW = 575kHz Single Channel Load Transient Response 50% (15A) to 100% (30A) Load Step, 15A/µs VIN = 12V, VOUT = 3.3V, fSW = 650kHz Dual Output Concurrent Rail, Start-Up/Shut Down VOUT1, 1.8V 500mV/DIV 100mV/DIV 50mV/DIV 4680 G07 100µs/DIV FIGURE 46 CIRCUIT, 12V TO 1.8V, FREQ = 500kHz COUT = 470µF ×2 POSCAP, 100µF ×4 CERAMIC RCOMP = 17k, EA-GM = 3.69ms, COMPna = 3.3nF, COMPnb = 68pF ILIM LOW, VOUT RANGE LOW VOUT0, 1V 500mV/DIV IOUT0, 18A 5A/DIV LOAD STEP 10A/DIV LOAD STEP 10A/DIV RUN0, RUN1 4680 G08 100µs/DIV FIGURE 46 CIRCUIT, 12V TO 2.5V, FREQ = 575kHz COUT = 470µF ×2 POSCAP, 100µF ×4 CERAMIC RCOMP = 20k, EA-GM = 1.68ms, COMPna = 3.3nF, COMPnb = 68pF ILIM LOW, VOUT RANGE LOW 4680 G09 100µs/DIV FIGURE 46 CIRCUIT, 12V TO 3.3V, FREQ = 650kHz COUT = 470µF ×2 POSCAP, 100µF ×4 CERAMIC RCOMP = 20k, EA-Gm = 3.02ms, COMPna = 3.3nF, COMPnb = 68pF ILIM LOW, VOUT RANGE HIGH Dual Output Concurrent Rail, Start-Up/Shut Down, Pre-Bias Single Phase Single Output Short-Circuit Protection, No Load VOUT1, 1.8V 500mV/DIV 2V/DIV 4680 G10 2ms/DIV FIGURE 46 CIRCUIT, 12VIN, 30A LOAD ON VOUT0, NO LOAD ON VOUT1 TON_DELAY0 = 0ms TON_DELAY1 = 0ms TON_RISE0 = 3ms TON_RISE1 = 5.297ms TOFF_DELAY0 = 2.43ms TOFF_DELAY1 = 0ms TOFF_FALL0 = 3ms TOFF_FALL1 = 5.328ms ON_OFF CONFIGn = 0X1E Single Phase Single Output Short-Circuit Protection, 30A Load VOUT0 500mV/DIV VOUT0 500mV/DIV IIN 2A/DIV IIN 2A/DIV VOUT0, 1V 500mV/DIV IOUT0, 30A 10A/DIV RUN0, RUN1 2V/DIV 4680 G11 2ms/DIV FIGURE 46 CIRCUIT, 12VIN, 30A LOAD ON VOUT0, NO LOAD ON VOUT1, VOUT1 IS PRE-BIASED TO 500mV THROUGH A DIODE TON_DELAY0 = 0ms TON_DELAY1 = 0ms TON_RISE0 = 3ms TON_RISE1 = 5.297ms TOFF_DELAY0 = 2.43ms TOFF_DELAY1 = 0ms TOFF_FALL0 = 3ms TOFF_FALL1 = 5.328ms ON_OFF CONFIGn = 0X1E 4680 G12 20µs/DIV FIGURE 46 CIRCUIT, 12VIN, NO LOAD ON VOUT0 PRIOR TO APPLICATION OF SHORT-CIRCUIT USE HIGH RANGE OF I LIMIT SYSTEM SHORT-CIRCUIT USING LOW IMPEDANCE COPPER ACROSS OUTPUT (HARD SHORT) 4680 G13 20µs/DIV FIGURE 46 CIRCUIT, 12VIN, 30A LOAD ON VOUT0 PRIOR TO APPLICATION OF SHORT-CIRCUIT USE HIGH RANGE OF I LIMIT SYSTEM SHORT-CIRCUIT USING LOW IMPEDANCE COPPER ACROSS OUTPUT (HARD SHORT) Rev. B For more information www.analog.com 13 LTM4680 TYPICAL PERFORMANCE CHARACTERISTICS Supply Current vs Load Current Comparison, RSENSE = 3mΩ, 12V to 1.8VOUT, 500kHz 14 6 5 4 3 2 RSENSE READBACK 4 RSENSE READBACK 1 0 70 0 10 20 40 30 50 LOAD CURRENT (A) 60 READ_IOUT of 16 LTM4680 Channels 12VIN, 1VOUT, TJ = 25°C, IOUTn = 30A, System Having Reached Thermally Steady-State Condition, No Airflow 3 3 30.6 30.3 30.3 30.3 30.2 30.2 30.1 30.0 30.0 29.9 0 29.9 1 READ_IOUT CHANNEL READBACK (A) 4680 G17 14 60 4680 G18 70 2 1 0 30.1 2 29.8 30.4 30.4 30.5 30.6 30.7 30.7 30.8 30.8 30.9 30.9 31.0 31.0 31.2 READ_IOUT CHANNEL READBACK (A) NUMBER OF CHANNELS 3 NUMBER OF CHANNELS 4 0 20 40 30 50 LOAD CURRENT (A) READ_IOUT of 16 LTM4680 Channels 12VIN, 1VOUT, TJ = 125°C, IOUTn = 30A, System Having Reached Thermally Steady-State Condition, No Airflow 4 1 10 4680 G16 4 2 0 4680 G15 READ_IOUT of 16 LTM4680 Channels 12VIN, 1VOUT, TJ = –40°C, IOUTn = 30A, System Having Reached Thermally Steady-State Condition, No Airflow NUMBER OF CHANNELS 0 70 30.1 4680 G14 RSENSE READBACK 2 30.0 60 6 29.9 30 50 20 40 LOAD CURRENT (A) 8 29.9 10 10 29.8 0 12 29.8 1 0 16 7 29.7 2 18 8 29.6 3 9 29.4 4 20 30.3 INPUT CURRENT (A) INPUT CURRENT (A) 5 10 INPUT CURRENT (A) 6 Supply Current vs Load Current Comparison, RSENSE = 3mΩ, 12V to 3.3VOUT, 650kHz 30.2 Supply Current vs Load Current Comparison, RSENSE = 3mΩ, 12V to 1.0VOUT, 250kHz TA = 25°C, 12VIN to 1VOUT, unless otherwise noted. READ_IOUT CHANNEL READBACK (A) 4680 G19 Rev. B For more information www.analog.com LTM4680 PIN FUNCTIONS PACKAGE ROW AND COLUMN LABELING MAY VARY AMONG µModule PRODUCTS. REVIEW EACH PACKAGE LAYOUT CAREFULLY. GND (A3-A6, B1, B3-B6, C1-C6, D2-D6, E5-E6, F5-F7, G5-G8, H5-H8, J2-J6, K2-6, L1, L3-L6, M3-M6): Power Ground of the LTM4680. Power return for VOUT0 and VOUT1. Return input and output capacitors to this point . VOUT0 (K7-K11, L7-L12, M7-M10): Channel 0 Output Voltage. Place recommended output capacitors from this shape to GND. See recommended layout. VOSNS0+ (M11): Channel 0 Positive Differential Voltage Sense Input. Together, VOSNS0+ and VOSNS0– serve to kelvin-sense the VOUT0 output voltage at VOUT0’s point of load (POL) and provide the differential feedback signal directly to channel 0’s feedback loop. Command VOUT0’s target regulation voltage by serial bus. Its initial command value at SVIN power-up is dictated by NVM (non-volatile memory) contents (factory default: 1.000V)—or, optionally, may be set by configuration resistors; see VOUT0_ CFG and the Applications Information section. VOSNS0– (M12): Channel 0 Negative Differential Voltage Sense Input. See VOSNS0+. VOUT1 (A7-A10, B7-B12, C7-C9, D7): Channel 1 Output Voltage. Place recommended output capacitors from this shape to GND See recommended layout. VOSNS1+ (A11): Channel 1 Positive Differential Voltage Sense Input. Together, VOSNS1+ and VOSNS1– serve to kelvin-sense the VOUT1 output voltage at VOUT1’s point of load (POL) and provide the differential feedback signal directly to channel 1’s feedback loop. Command VOUT1’s target regulation voltage by serial bus. Its initial command value at SVIN power-up is dictated by NVM (non-volatile memory) contents (factory default: 1.000V)—or, optionally, may be set by configuration resistors; see VOUT1_ CFG and the Applications Information section. VOSNS1– (A12): Channel 1 Negative Differential Voltage Sense Input. See VOSNS1+. SGND (F9-10, G9-10): SGND is the signal ground return path of the LTM4680. SGND is not internally connected to GND. Connect SGND to GND local to the LTM4680. See recommended layout. VIN0 (G1-G4, H1-H4): Positive Power Input to Channel 0 Switching Stage. Provide sufficient decoupling capacitance in the form of multilayer ceramic capacitors (MLCCs) and low ESR electrolytic (or equivalent) to handle reflected input current ripple from the step-down switching stage. MLCCs should be placed as close to the LTM4680 as physically possible. See Layout Recommendations in the Applications Information section. VIN1 (E1-E4, F1-F4): Positive Power Input to Channel 1 Switching Stage. Provide sufficient decoupling capacitance in the form of MLCCs and low ESR electrolytic (or equivalent) to handle reflected input current ripple from the step-down switching stage. MLCCs should be placed as close to the LTM4680 as physically possible. See Layout Recommendations in the Applications Information section. SW0 (L2, M1-M2): Switching Node of Channel 0 StepDown Converter Stage. Used for test purposes or EMIsnubbing. May be routed a short distance to a local test point to monitor switching action of channel 0, if desired, but do not route near any sensitive signals; otherwise, leave electrically isolated (open). SW1 (A1-A2, B2): Switching Node of Channel 1 StepDown Converter Stage. Used for test purposes or EMIsnubbing. May be routed a short distance to a local test point to monitor switching action of channel 1, if desired, but do not route near any sensitive signals; otherwise, leave open. SVIN (D1): Input Supply for LTM4680’s Internal Control IC. In most applications, SVIN connects to VIN0 and/or VIN1. SVIN can be operated from an auxiliary supply separate from VIN0/VIN1 for powering the VIN0/VIN1 from a lower supply like 3.3V. The SVIN pin has an onboard 1Ω and 1µF decoupling capacitor. The 1Ω resistor is used to measure the actual control chip current. See MFR_READ_ICHIP Rev. B For more information www.analog.com 15 LTM4680 PIN FUNCTIONS and MFR_ADC_CONTROL COMMAND section. When operating from 4.5V to 5.75V with no auxiliary bias supply, then the main input supply should connect to SVIN and INTVCC. See Test Circuit 2 for an example. In this configuration, the ICHIP current will not be relevant since INTVCC is connected to SVIN. VDD25 (D12): Internally Generated 2.5V Power Supply Output Pin. Do not load this pin with external current; it is used strictly to bias internal logic and provides current for the internal pull-up resistors connected to the configuration-programming pins. No external decoupling is required. IIN+ (J1): Positive Current Sense Amplifier Input. If the input current sense amplifier is not used, this pin must be shorted to the IIN– and SVIN pin. See Operation section for detail about the input current sensing. ASEL (F12): Serial Bus Address Configuration Pin. On any given I2C/SMBus serial bus segment, every device must have its own unique slave address. If this pin is left open, the LTM4680 powers up to its default slave address of 0x4F (hexadecimal), i.e., 1001111b (industry-standard convention is used throughout this document: 7-bit slave addressing). The lower four bits of the LTM4680’s slave address can be altered from this default value by connecting a resistor from this pin to SGND. Minimize capacitance—especially when the pin is left open—to assure accurate detection of the pin state. See Table 4. IIN– (K1): Negative Current Sense Amplifier Input. If the input current sense amplifier is not used, this pin must be shorted to the IIN+ and SVIN pin. See Operation section for detail about the input current sensing. EXTVCC (F8): External Power Input to an Internal Switch Connected to INTVCC. This switch closes and supplies the IC power, bypassing the internal regulator whenever EXTVCC is higher than 4.7V and VIN is higher than 7V. EXTVCC also powers up VDD33 when EXTVCC is higher than 4.7V and INTVCC is lower than 3.8V. Do not exceed 6V on this pin. Decouple this pin to PGND with a minimum of 4.7µF low ESR tantalum or ceramic capacitor. If the EXTVCC pin is not used to power INTVCC, the EXTVCC pin must be tied GND. INTVCC (E7) : Internal Regulator, 5.5V Output. When operating the LTM4680 from 5.75V ≤ SVIN ≤ 16V, an LDO generates INTVCC from SVIN to bias internal control circuits and the MOSFET drivers of the LTM4680. An external 2.2µF ceramic decoupling is required. INTVCC is regulated regardless of the RUNn pin state. When operating the LTM4680 with 4.5V ≤ SVIN < 5.75V, INTVCC must be electrically shorted to SVIN. VDD33 (E8): Internally Generated 3.3V Power Supply Output Pin. This pin should only be used to provide external current for the pull-up resistors required for FAULTn, SHARE_CLK, and SYNC, and may be used to provide external current for pull-up resistors on RUNn, SDA, SCL, ALERT and PGOODn. No external decoupling is required. 16 FSWPH_CFG (E9): Switching Frequency, Channel Phase-Interleaving Angle and Phase Relationship to SYNC Configuration Pin. If this pin is left open—or, if the LTM4680 is configured to ignore pin-strap (RCONFIG) resistors, i.e., MFR_CONFIG_ALL[6] = 1b—then LTM4680’s switching frequency (FREQUENCY_SWITCH) and channel phase relationships (with respect to the SYNC clock; MFR_PWM_CONFIG[2:0]) are dictated at SVIN power-up according to the LTM4680’s NVM contents. Default factory values are: 575kHz operation; channel 0 at 0°; and channel 1 at 180°C (convention throughout this document: a phase angle of 0° means the channel’s switch node rises coincident with the falling edge of the SYNC pulse). Connecting a resistor from this pin to SGND (and using the factory-default NVM setting of MFR_CONFIG_ALL[6] = 0b) allows a convenient way to configure multiple LTM4680s with identical NVM contents for different switching frequencies of operation and phase interleaving angle settings of intra- and extra-moduleparalleled channels—all, without GUI intervention or the need to “custom pre-program” module NVM contents. (See the Operation section.) Minimize capacitance—especially when the pin is left open—to assure accurate detection of the pin state. See Table 3. Rev. B For more information www.analog.com LTM4680 PIN FUNCTIONS VOUT0_CFG (E11): Output Voltage Select Pin for VOUT0, Coarse Setting. If the VOUT0_CFG and VTRIM0_CFG pins are both left open—or, if the LTM4680 is configured to ignore pin-strap (RCONFIG) resistors, i.e., MFR_CONFIG_ ALL[6] = 1b—then the LTM4680s target VOUT0 output voltage setting (VOUT_COMMAND0) and associated power-good and OV/UV warning and fault thresholds are dictated at SVIN power-up according to the LTM4680’s NVM contents. A resistor connected from this pin to SGND—in combination with resistor pin settings on VTRIM0_CFG, and using the factory-default NVM setting of MFR_CONFIG_ALL[6] = 0b—can be used to configure the LTM4680’s channel 0 output to power-up to a VOUT_COMMAND value (and associated output voltage monitoring and protection/fault-detection thresholds) different from those of NVM contents. (See Table 1 in the Operation section.) Connecting resistor(s) from VOUT0_CFG to SGND and/or VTRIM0_CFG to SGND in this manner allows a convenient way to configure multiple LTM4680s with identical NVM contents for different output voltage settings all without GUI intervention or the need to “custom-preprogram” module NVM contents. Minimize capacitance especially when the pin is left open to assure accurate detection of the pin state. Note that use of RCONFIGs on VOUT0_CFG/VTRIM0_CFG can affect the VOUT0 range setting (MFR_PWM_MODE0[1]) and loop gain. VTRIM1_CFG (E10): Output Voltage Select Pin for VOUT1, Fine Setting. Works in combination with VOUT1_CFG to affect the VOUT_COMMAND (and associated output voltage monitoring and protection/fault-detection thresholds) of channel 1, at SVIN power-up. (See VOUT1_CFG and the Operation section.) Minimize capacitance especially when the pin is left open to assure accurate detection of the pin state. Note that use of RCONFIGs on VOUT1_CFG/ VTRIM1_CFG can affect the VOUT1 range setting (MFR_ PWM_MODE1[1]) and loop gain. VOUT1_CFG (E12): Output Voltage Select Pin for VOUT1, Coarse Setting. If the VOUT1_CFG and VTRIM1_CFG pins  are both left open or, if the LTM4680 is configured to ignore pin-strap (RCONFIG) resistors, i.e., MFR_CONFIG_ALL[6] = 1b then the LTM4680’s target VOUT1 output voltage setting (VOUT_COMMAND1) and associated OV/UV warning and fault thresholds are dictated at SVIN power-up according to the LTM4680’s NVM contents, in precisely the same fashion that the VOUT1_ CFG and VTRIM1_CFG pins affect the respective settings of VOUT1/channel 1. (See VOUT1_CFG, VTRIM1_CFG and the Operation section.) Minimize capacitance—especially when the pin is left open—to assure accurate detection of the pin state. Note that use of RCONFIGs on VOUT1_CFG/ VTRIM1_CFG can affect the VOUT1 range setting (MFR_ PWM_MODE1[1]) and loop gain. VTRIM0_CFG (C12): Output Voltage Select Pin for VOUT0, Fine Setting. Works in combination with VOUT0_CFG to affect the VOUT_COMMAND (and associated output voltage monitoring and protection/fault-detection thresholds) of channel 0, at SVIN power-up. (See VOUT0_CFG and the Operation section.) Minimize capacitance—especially when the pin is left open—to assure accurate detection of the pin state. Note that use of RCONFIGs on VOUT0_CFG/ VTRIM0_CFG can affect the VOUT0 range setting (MFR_ PWM_MODE0[1]) and loop gain. RUN0, RUN1 (G12, F11 Respectively): Enable Run Input for Channels 0 and 1, Respectively. Open-drain input and output. Logic high on these pins enables the respective outputs of the LTM4680. These open-drain output pins hold the pin low until the LTM4680 is out of reset and SVIN is detected to exceed VIN_ON. A pull-up resistor to 3.3V is required in the application. The LTM4680 pulls RUN0 and/ or RUN1 low, as appropriate, when a global fault and/or channel-specific fault occurs whose fault response is configured to latch off and cease regulation; issuing a CLEAR_FAULTS command via I2C or power-cycling SVIN is necessary to restart the module, in such cases. Do not pull RUN logic high with a low impedance source. PGOOD0/PGOOD1 (J7/D9): Power Good Indicator Outputs. Open-drain logic output that is pulled to ground when the output exceeds the UV and OV regulation window. The output is deglitch by an internal 100µs filter. A pull-up resistor to 3.3V is required in the application. Rev. B For more information www.analog.com 17 LTM4680 PIN FUNCTIONS FAULT0/FAULT1 (H12/G11): Digital Programmable Fault Inputs and Outputs. Open-drain output. A pull-up resistor to 3.3V is required in the application. COMP0b/COMP1b (H9/C10): Current Control Threshold and Error Amplifier Compensation Nodes. Each associated channel’s current comparator tripping threshold increases with its compensation voltage. Each channel has a 6.8pF to SGND. COMP0a/COMP1a (J9/D10): Loop Compensation Nodes. The internal PWM loop compensation resistors RCOMPn of the LTM4680 can be adjusted using bit[4:0] of the MFR_PWM_COMP command. The transconductance of the LTM4680 PWM error amplifier can be adjusted using bit[7:5] of the MFR_PWM_COMP command. These two loop compensation parameters can be programmed when device is in operation. Refer to the Programmable Loop Compensation subsection in the Applications Information section for further details. See Figure 1. SYNC (K12): External Clock Synchronization Input and Open-Drain Output Pin. If an external clock is present at this pin, the switching frequency will be synchronized to the external clock. If clock master mode is enabled, this pin will pull low at the switching frequency with a 500ns pulse to ground. A resistor pull-up to 3.3V is required in the application if the LTM4680 is the master. SCL (J12): Serial Bus Clock Open-Drain Input (Can Be an Input and Output, if Clock Stretching is Enabled). A pull-up resistor to 3.3V is required in the application for digital communication to the SMBus master(s) that nominally drive this clock. The LTM4680 will never encounter scenarios where it would need to engage clock stretching unless SCL communication speeds exceed 100kHz—and even then, LTM4680 will not clock stretch unless clock stretching is enabled by means of setting MFR_CONFIG_ ALL[1] = 1b. The factory-default NVM configuration setting has MFR_CONFIG_ALL[1] = 0b: clock stretching disabled. If communication on the bus at clock speeds above 100kHz is required, the user’s SMBus master(s) needs to implement clock stretching support to assure 18 solid serial bus communications, and only then should MFR_CONFIG_ALL[1] be set to 1b. When clock stretching is enabled, SCL becomes a bidirectional, open-drain output pin on LTM4680. SDA (H10): Serial Bus Data Open-Drain Input and Output. A pull-up resistor to 3.3V is required in the application. ALERT (H11): Open-Drain Digital Output. A pull-up resistor to 3.3V is required in the application only if SMBALERT interrupt detection is implemented in one’s SMBus system. SHARE_CLK (D11): Share Clock, Bidirectional Open-Drain Clock Sharing Pin. Nominally 100kHz. Used for synchronizing the time base between multiple LTM4680s (and any other Analog Devices devices with a SHARE_ CLK pin)— to realize well-defined rail sequencing and rail tracking. Tie the SHARE_CLK pins of all such devices together; all devices with a SHARE_CLK pin will synchronize to the fastest clock. A pull-up resistor to 3.3V is only required when synchronizing the time base between devices. TSNS0a, TSNS0b (J11 and J8, Respectively): Channel 0 Temperature Excitation/Measurement and Thermal Sensor Pins, Respectively. Connect TSNS0a to TSNS0b. This allows the LTM4680 to monitor the power stage temperature of channel 0. TSNS1a, TSNS1b (J10 and D8, Respectively): Channel 1 Temperature Excitation/Measurement and Thermal Sensor Pins, Respectively. In most applications, connect TSNS1a to TSNS1b. This allows the LTM4680 to monitor the power stage temperature of channel 1. See the Operation section for information on how to use TSNS1a to monitor an external temperature sensor. WP (C11): Write Protect Pin, Active High. An internal 10µA current source pulls this pin to VDD33. If WP is open circuit or logic high, only I2C writes to PAGE, OPERATION, CLEAR_FAULTS, MFR_CLEAR_PEAKS and MFR_EE_UNLOCK are supported. Additionally, Individual faults can be cleared by writing 1b’s to bits of interest in registers prefixed with “STATUS”. If WP is low, I2C writes are unrestricted. Rev. B For more information www.analog.com LTM4680 SIMPLIFIED BLOCK DIAGRAM + RSENSE CIN2 CIN1 2.2µF IN+ IN– SVIN VIN0 + – 1Ω VOUT0 ADJ TO 3.3V UP TO 30A COUT2 INTVCC EXTVCC VDD33 SW1 MT1 330nH VOUT0 GND 1µF INPUT CURRENT/ICHIP (READ_IIN, MFR_READ_IIN_PEAK TO ANALOG READBACK) MT0 COUT1 VIN1 2.2µF 2.2µF 1µF A=N SW0 1µF 330nH POWER CONTROL ANALOG SECTION 2.2µF MB0 2.2µF GND MB1 0.01µF DIE TEMP SENSE TSNS0b 0.01µF TSNS0 IOUT0 CURRENT SENSE TSNS0a TO ANALOG READBACK TO ANALOG READBACK CLOAD0 TSNS1b TSNS1a TEMP MUX VOSNS0– X1 PROG GM COMP0a CCOMPL + – 10:1 MUX EA0 6.8pF X1 ALL ANALOG READBACK SIGNALS COMP0b CCOMPH VOSNS1+ + REMOTE SENSE PROG RCOMP + EA1 – PROG GM – REMOTE SENSE VOSNS1– 6.8pF PROG RCOMP ADC PGOOD1 PGOOD0 SYNC SCL CCOMPH COMP1a SPI SLAVE 2.5V SDA CCOMPL 3.3V TOLERANT PULL-UP NOT SHOWN VDD25 2.2µF ALERT WP ROM RUN0 RAM SPI MASTER DIGITAL ENGINE RUN1 FAULT0 3.3V-TOLERANT PULL-UP NOT SHOWN LOAD1 CLOAD1 COMP1b POWER CONTROL DIGITAL SECTION 5.5V-TOLERANT PULL-UP NOT SHOWN COUT4 COUT3 SGND TSNS1 IOUT0 CURRENT SENSE VOSNS0+ LOAD0 VOUT1 ADJ TO 3.3V UP TO 30A VOUT1 SYNC DRIVER ASEL FSWPH_ CFG 32MHz OSC VTRIM0_ CFG VTRIM1_ CFG EEPROM FAULT1 VOUT0_CFG SHARE_CLK VOUT1_CFG CONFIG RESISTORS TO 2.5V SGND NOT SHOWN 4680 F02 Figure 2. Simplified LTM4680 Block Diagram DECOUPLING REQUIREMENTS TA = 25°C. Using Test Circuit 1 configuration. SYMBOL PARAMETER CONDITIONS CINH External High Frequency Input Capacitor Requirement (5.75V ≤ VIN ≤ 16V, VOUTn Commanded to 1.000V) IOUT0 = 30A IOUT1 = 30A MIN TYP 100 100 MAX UNITS µF µF COUTn External High Frequency Output Capacitor Requirement (5.75V ≤ VIN ≤ 16V, VOUTn Commanded to 1.000V) IOUT0 = 30A IOUT1 = 30A 800 800 µF µF Rev. B For more information www.analog.com 19 COUT2 COUT1 For more information www.analog.com CCOMPL 3.3V-TOLERANT PULL-UP NOT SHOWN 5.5V-TOLERANT PULL-UP NOT SHOWN CCOMPH CLOAD0 (VOUT0 TELEMETRY: READ_VOUT0, MFR_VOUT_PEAK, READ_VOUT0) LOAD0 VOUT0 ADJ TO 3.6V UP TO 30A CSNUB0 RSNUB0 OPTIONAL SNUBBER X1 TSNS0 IOUT0 SENSE MB0 PROG RCOMP PROG GM MFR_PWM_COMP CHANNEL TIMING MANAGEMENT VDD33 I2C-BASED SMBus INTERFACE WITH PMBus COMMANDS (10kHZ TO 400kHz COMPATIBLE) UVLO 2µA VBE SENSING ROM PROGRAM RAM 2.2µF INTVCC EXTVCC TEMP MUX DIE TEMP SENSE READ_TEMPERATURE0 32µA EEPROM 1µF SYNC DRIVER + EA1 – DCR SENSE Z 330nH CONFIG DETECT VDD33 X1 2.5V ASEL 2.2µF VDD25 SYNC PGOOD1 COMP1a 6.8pF COMP1b VOSNS1– VOSNS1+ TSNS1a TSNS1b SGND GND 2.2µF VOUT1 SW1 4680 F03 VOUT1_CFG VOUT0_CFG VTRIM1_ CFG VTRIM0_ CFG FSWPH_ CFG 14.3k ×6 REMOTE SENSE TSNS1 PROG RCOMP – + 0.01µF READ_TEMPERATURE1 CHANNEL 1 TEMP (IOUT1 TELEMETRY: READ_IOUT1, MFR_IOUT_PEAK) (MFR_PWM_MODE, MFR_PWM_CONFIG, FREQUENCY_SWITCH) PROG GM MFR_PWM_COMP CCM CH1 I SIGNAL 32MHz OSC SETPOINT, UV, OV, ILIM DACs SINC3 SPI MASTER SPI SLAVE ADC 10:1 MUX MB1 MT1 VIN1 IOUT1 SENSE 2.2µF VDD33 (CURRENT MODE PWM CNTL LOOPS, POWER CONTROL ANALOG SECTION LINEAR REGULATORS, DACs, ADC, UV/OV MONITORS, VCO/PLL, MOSFET DRIVERS AND POWER CNTL LOGIC) DIGITAL ENGINE, MAIN CONTROL VDD33 COMPARE + – EA0 DCR SENSE Z CCM CH0 I SIGNAL 330nH POWER MANAGEMENT DIGITAL SECTION 6.8pF REMOTE SENSE SHARE_CLK FAULT1 FAULT0 RUN1 RUN0 10µA WP ALERT SDA SCL PGOOD0 COMP0a COMP0b VOSNS0– VOSNS0+ TSNS0a 0.01µF READ_TEMPERATURE1 CHANNEL 0 TEMP 2.2µF (IOUT0 TELEMETRY: READ_IOUT0, MFR_IOUT_PEAK) MT0 1µF SVIN TELEMETRY: (MFR_READ_ICHIP, READ_VIN, READ_VIN_PEAK) INPUT CURRENT/ICHIP (READIIN, MFRREADIINPEAK TO ANALOG READBACK) (MFR_PWM_MODE, MFR_PWM_CONFIG, FREQUENCY_SWITCH) TSNS0b GND VOUT0 SW0 A=N IIN 1µF VIN0 VIN SVIN 1Ω ICHIP IN– VOUT1 IN+ 2.2µF VOUT2 CIN2 IOUT1 CIN1 IOUT2 RSENSE PWM0 + TEMP 20 – PWM1 + CCOMPH CONFIG RESISTORS TO SGND NOT SHOWN 3.3V TOLERANT PULL-UP NOT SHOWN CCOMPL CLOAD1 LOAD1 VOUT1 ADJ COUT4 TO 3.6V UP TO 30A CSNUB1 RSNUB1 (VOUT0 TELEMETRY: READ_VOUT0, MFR_VOUT_PEAK, READ_POUT1) COUT3 OPTIONAL SNUBBER LTM4680 FUNCTIONAL DIAGRAM Figure 3. Functional LTM4680 Block Diagram Rev. B LTM4680 TEST CIRCUITS Test Circuit 1. LTM4680 ATE High VIN Operating Range Configuration, 5.75V ≤ VIN ≤ 16V 150µF TSNS1b TSNS1a TSNS0b TSNS0a PGOOD1 INTVCC PGOOD0 5.75V TO 16V EXTVCC VIN VDD25 VDD33 2.2µF IN+ RSENSE VOSNS0+ IN– 22µF ×5 – VIN1 RUN1 VOSNS1+ LTM4680 RUN0 – VOSNS1 FAULT0 FAULT1 SCL SYNC SDA ALERT SHARE_CLK 2200pF COUT0* BULK LOAD1 100µF ×4 VOUT1 1V, ADJUSTABLE UP TO 3.6V AT 30A COUT1* BULK I2C/SMBus I/F WITH PMBus COMMAND SET TO/FROM IPMI OR OTHER BOARD MANAGEMENT CONTROLLER *COUT0 AND COUT1 ARE OPTIONAL FOR ATE TEST (PULL-UP RESISTORS ON DIGITAL I/O PINS NOT SHOWN) 4680 TC01 2200pF 100pF SGND ASEL FSWPH_CFG VOUT1_CFG VOUT0_CFG VTRIM0_CFG COMP0b VTRIM1_CFG GND WP COMP0a SYNCHRONIZATION TIME-BASE REGISTER WRITE PROTECTION VOUT1 COMP1b FAULT INTERRUPTS 100µF ×4 VOUT0 1V, ADJUSTABLE UP TO 3.6V AT 30A SW1 SVIN COMP1a ON/OFF CONTROL LOAD0 VOSNS0 VIN0 SVIN SW0 VOUT0 100pF Rev. B For more information www.analog.com 21 LTM4680 TEST CIRCUITS Test Circuit 2. LTM4680 ATE Low VIN Operating Range Configuration, 4.5V ≤ VIN ≤ 5.75V 1Ω SVIN TSNS1b TSNS1a TSNS0b TSNS0a PGOOD1 VOSNS0– VIN0 SW1 SVIN VOUT1 RUN1 – VOSNS1 FAULT0 FAULT1 SCL SYNC SDA ALERT SHARE_CLK 2200pF FSWPH_CFG VOUT1_CFG VOUT0_CFG VTRIM0_CFG GND WP SGND LOAD1 100µF ×4 100µF ×4 VOUT0 1V, ADJUSTABLE UP TO 3.6V AT 30A COUT0* BULK VOUT1 1V, ADJUSTABLE UP TO 3.6V AT 30A COUT1* BULK I2C/SMBus I/F WITH PMBus COMMAND SET TO/FROM IPMI OR OTHER BOARD MANAGEMENT CONTROLLER *COUT0 AND COUT1 ARE OPTIONAL FOR ATE TEST (PULL-UP RESISTORS ON DIGITAL I/O PINS NOT SHOWN) 4680 TC02 2200pF 100pF LOAD0 VOSNS1+ LTM4680 RUN0 COMP1a SYNCHRONIZATION TIME-BASE REGISTER WRITE PROTECTION VIN1 VTRIM1_CFG FAULT INTERRUPTS VOSNS0+ COMP0b ON/OFF CONTROL IN– COMP0a SVIN SW0 VOUT0 RSENSE 22µF ×5 22 EXTVCC INTVCC IN+ ASEL 150µF PGOOD0 4.5V TO 5.75V COMP1b VIN VDD25 VDD33 2.2µF 100pF Rev. B For more information www.analog.com LTM4680 OPERATION POWER MODULE INTRODUCTION Programmable Output Voltage n The LTM4680 is a highly configurable dual 30A output standalone nonisolated switching mode step-down DC/DC power supply with built-in EEPROM NVM (nonvolatile memory) with ECC and I2C-based PMBus/ SMBus 2-wire serial communication interface capable of 400kHz SCL bus speed. Two output voltages can be regulated (VOUT0, VOUT1—collectively, VOUTn) with a few external input and output capacitors and pull-up resistors. Readback telemetry data of input and output voltages and input and output currents, and module temperatures are continually digitized cyclically by an integrated 16-bit ADC (analog-to-digital converter). Many fault thresholds and responses are customizable. Data can be autonomously saved to EEPROM when a fault occurs, and the resulting fault log can be retrieved over I2C at a later time, for analysis. See Figures 2 and 3 for Block Diagrams. Programmable Input Voltage On and Off Threshold Voltage n Programmable Current Limit n Programmable Switching Frequency n Programmable OV and UV Threshold voltage n Programmable ON and Off Delay Times n Programmable Output Rise/Fall Times n Phase-Locked Loop for Synchronous PolyPhase Operation (2, 3, 4 or 6 Phases) n Nonvolatile Configuration Memory with ECC n Optional External Configuration Resistors for Key Operating Parameters n Optional Time Base Interconnect for Synchronization Between Multiple Controllers n POWER MODULE OVERVIEW, MAJOR FEATURES WP Pin to Protect Internal Configuration n Major Features Include: Stand Along Operation After User Factory Configuration n Dedicated Power Good Indicators n Direct Input and Chip Current Sensing n PMBus, Version 1.2, 400kHz Compliant Interface n Programmable Loop Compensation Parameters n TINIT Start-Up Time: 30ms n PWM Synchronization Circuit, (See Frequency and Phasing Section for Details) n MFR_ADC_CONTROL for Fast ADC Sampling of One Parameter (as Fast as 8ms) (See PMBus Command for Details) The PMBus interface provides access to important power management data during system operation including: Internal Controller Temperature n n n Fully Differential Output Sensing for Both Channels; VOUT0/VOUT1 Both Programmable Up to 3.6V n Average Output Voltage n Average Input Voltage n Average Input Current n Power-Up and Program EEPROM with EXTVCC n Input Voltage Up to 16V n n ∆VBE Temperature Sensing n SYNC Contention Circuit (Refer to Frequency and Phase Section for Details) Fault Logging n Average Chip Input Current from VIN Configurable, Latched and Unlatched Individual Fault and Warning Status n n Internal Power Channel Temperature Average Output Current Individual channels are accessed through the PMBus using the PAGE command, i.e., PAGE 0 or 1. Fault reporting and shutdown behavior are fully configurable. Two individual FAULT0, FAULT1 outputs are provided, both of which can be masked independently. Rev. B For more information www.analog.com 23 LTM4680 OPERATION Three dedicated pins for ALERT, PGOOD0/PGOOD1 functions are provided. The shutdown operation also allows all faults to be individually masked and can be operated in either unlatched (hiccup) or latched modes. Individual status commands enable fault reporting over the serial bus to identify the specific fault event. Fault or warning detection includes the following: Output Undervoltage/Overvoltage n Input Undervoltage/Overvoltage n Input and Output Overcurrent n Internal Overtemperature n Communication, Memory or Logic (CML) Fault n EEPROM WITH ECC The LTM4680 contains internal EEPROM with ECC (Error Correction Coding) to store user configuration settings and fault log information. EEPROM endurance retention and mass write operation time are specified in the Electrical Characteristics and Absolute Maximum Ratings sections. Write operations above TJ = 85°C are possible although the Electrical Characteristics are not guaranteed and the EEPROM will be degraded. Read operations performed at temperatures between –40°C and 125°C will not degrade the EEPROM. Writing to the EEPROM above 85°C will result in a degradation of retention characteristics. The fault logging function, which is useful in debugging system problems that may occur at high temperatures, only writes to fault log EEPROM locations. If occasional writes to these registers occur above 85°C, the slight degradation in the data retention characteristics of the fault log will not take away from the usefulness of the function. It is recommended that the EEPROM not be written when the die temperature is greater than 85°C. If the die temperature exceeds 130°C, the LTM4680 will disable all EEPROM write operations. All EEPROM write operations will be re-enabled when the die temperature drops below 125°C. (The controller will also disable all the switching when the die temperature exceeds the internal overtemperature fault limit 160°C with a 10°C hysteresis). 24 The degradation in EEPROM retention for temperatures >125°C can be approximated by calculating the dimensionless acceleration factor using the following equation: AF = e ⎡⎛ Ea ⎞ ⎛ ⎞⎤ 1 1 – ⎢⎜⎝ ⎟⎠ •⎜ ⎟⎠ ⎥ +273 +273 T T k ⎝ USE STRESS ⎦ ⎣ where: AF = acceleration factor Ea = activation energy = 1.4eV k = 8.617 • 10–5 eV/°K TUSE = 125°C specified junction temperature TSTRESS = actual junction temperature in °C Example: Calculate the effect on retention when operating at a junction temperature of 135°C for 10 hours. TSTRESS = 130°C TUSE = 125°C, AF = e([(1.4/8.617 • 10 –5) • (1/398 – 1/403)] ) = 16.6 The equivalent operating time at 125°C = 16.6 hours. Thus the overall retention of the EEPROM was degraded by 16.6 hours as a result of operating at a junction temperature of 130°C for 10 hours. The effect of the overstress is negligible when compared to the overall EEPROM retention rating of 87,600 hours at a maximum junction temperature of 125°C. The integrity of the entire onboard EEPROM is checked with a CRC calculation each time its data is to be read, such as after a power-on reset or execution of a RESTORE_USER_ ALL command. If a CRC error occurs, the CML bit is set in the STATUS_BYTE and STATUS_WORD commands, the EEPROM CRC Error bit in the STATUS_MFR_SPECIFIC command is set, and the ALERT and RUN pins pulled low (PWM channels off). At that point the device will only respond at special address 0x7C, which is activated only after an invalid CRC has been detected. The chip will also respond at the global addresses 0x5A and 0x5B, but use of these addresses when attempting to recover from a CRC issue is not recommended. All power supply rails associated with either PWM channel of a device reporting an invalid CRC should remain disabled until the issue is Rev. B For more information www.analog.com LTM4680 OPERATION resolved. See the Applications Information section or contact the factory for details on efficient in-system EEPROM programming, including bulk EEPROM Programming, which the LTM4680 also supports. The LTM4680 contains dual integrated constant frequency current mode control buck regulators (channel 0 and channel 1) whose built-in power MOSFETs are capable of fast switching speed. The factory NVM-default switching frequency clocks SYNC at 350kHz, to which the regulators synchronize their switching frequency. The default phase-interleaving angle between the channels is 180°. A pin-strapping resistor on FSWPH_CFG configures the frequency of the SYNC clock (switching frequency) and the channel phase relationship of the channels to each other and with respect to the falling edge of the SYNC signal. (Most possible combinations of switching frequency and phase-angle assignments are settleable by resistor pin programming; see Table 3. Configure the LTM4680’s NVM to implement settings not available by resistorpin strapping.) When a FSWPH_CFG pin-strap resistor sets the channel phase relationship of the LTM4680’s channels, the SYNC clock is not driven by the module; instead, SYNC becomes strictly a high impedance input and channel switching frequency is then synchronized to SYNC provided by an externally-generated clock or sibling LTM4680 with pull-up resistor to VDD33. Switching frequency and phase relationship can be altered via the I2C interface, but only when switching action is off, i.e., when the module is not regulating either output. See the Applications Information section for details. Programmable analog feedback loop compensation for channel 0 and channel 1 is accomplished with a capacitor connection from COMP0,1a to SGND, and a capacitor from COMP0,1b to SGND. The COMP0,1b pin is for the high frequency gain roll off and is the gm amplifier output that has a programmable range, and the COMP0,1a pin has the programmable resistor range along with a capacitor to SGND that sets the frequency compensation. See Programmable Loop Compensation section. The LTM4680 module has sufficient stability margins and good transient performance with a wide range of output capacitors—even all-ceramic MLCCs. Table 12 through Table 14 provide guidance on input and output capacitors recommended for many common operating conditions along with the programmable compensation settings. The Analog Devices LTpowerCAD tool is available for transient and stability analysis, and experienced users who prefer to adjust the module’s feedback loop compensation parameters can use this tool. POWER-UP AND INITIALIZATION The LTM4680 is designed to provide standalone supply sequencing and controlled turn-on and turn-off operation. It operates from a single input supply (4.5V to 16V) while three on-chip linear regulators generate internal 2.5V, 3.3V and 5.5V. If VIN does not exceed 6V, and the EXTVCC pin is not driven by an external supply, the INTVCC and VIN pins must be tied together. The controller configuration is initialized by an internal threshold based UVLO where VIN must be approximately 4V and the 5.5V, 3.3V and 2.5V linear regulators must be within approximately 20% of the regulated values. In addition to the power supply, a PMBus RESTORE_USER_ALL or MFR_RESET command can initialize the part too. The EXTVCC pin is driven by an external regulator to improve efficiency of the circuit and minimize power loss on the LTM4680 when VIN is high. The EXTVCC pin must exceed approximately 4.8V, and VIN must exceed 7V before the INTVCC LDO operates from the EXTVCC pin. To minimize application power, the EXTVCC pin can be supplied by a switching regulator. During initialization, the external configuration resistors are identified and/or contents of the NVM are read into the controller’s commands and the power train is held off. The RUNn and FAULTn and PGOODn are held low. The LTM4680 will use the contents of Table 1 thru Table 4 to determine the resistor defined parameters. See the Resistor Configuration section for more details. The resistor configuration pins only control some of the preset values of the controller. The remaining values are programmed in NVM either at the factory or by the user. If the configuration resistors are not inserted or if the ignore RCONFIG bit is asserted (bit 6 of the MFR_ CONFIG_ALL configuration command), the LTM4680 Rev. B For more information www.analog.com 25 LTM4680 OPERATION will use only the contents of NVM to determine the DC/ DC characteristics. The ASEL value read at power-up or reset is always respected unless the pin is open. The ASEL will set the bottom 4LSBs and the MSBs are set by NVM. See the Applications Information section for more details. After the part has initialized, an additional comparator monitors VIN. The VIN_ON threshold must be exceeded before the output power sequencing can begin. After VIN is initially applied, the part will typically require 30ms to initialize and begin the TON_DELAY timer. The readback of voltages and currents may require an additional 0ms to 90ms. SOFT-START The method of start-up sequencing described below is time-based. The part must enter the run state prior to soft-start. The run pins are released by the LTM4680 after the part is initialized and VIN is greater than the VIN_ON threshold. If multiple LTM4680s are used in an application, they all hold their respective run pins low until all devices are initialized and VIN exceeds the VIN_ON threshold for every device. The SHARE_CLK pin assures all the devices connected to the signal use the same time base. The SHARE_CLK pin is held low until the part has been initialized after VIN is applied. The LTM4680 can be set to turn-off (or remain off) if SHARE_CLK is low (set bit 2 of MFR_CHAN_CONFIG to 1). This allows the user to assure synchronization across numerous LTC® devices even if the RUN pins cannot be connected together due to board constraints. In general, if the user cares about synchronization between chips it is best not only to connect all the respective RUN pins together but also to connect all the respective SHARE_CLK pins together and pulled up to VDD33 with a 10k resistor. This assures all chips begin sequencing at the same time and use the same time base. After the RUN pins release and prior to entering a constant output voltage regulation state, the LTM4680 performs a monotonic initial ramp or “soft-start”. Soft-start is performed by actively regulating the load voltage while digitally ramping the target voltage from 0V to the commanded voltage set-point. Once the LTM4680 is commanded to turn on (after power up and initialization), the controller waits for the user specified turn-on delay 26 (TON_DELAY) prior to initiating this output voltage ramp. The rise time of the voltage ramp can be programmed using the TON_RISE command to minimize inrush currents associated with the start-up voltage ramp. The soft-start feature is disabled by setting the value of TON_ RISE to any value less than 0.25ms. The LTM4680 PWM always uses discontinuous mode during the TON_RISE operation. In discontinuous mode, the bottom MOSFET is turned off as soon as reverse current is detected in the inductor. This will allow the regulator to start up into a pre-biased load. When the TON_MAX_FAULT_LIMIT is reached, the part transitions to continuous mode, if so programmed. If TON_MAX_FAULT_LIMIT is set to zero, there is no time limit and the part transitions to the desired conduction mode after TON_RISE completes and VOUT has exceeded the VOUT_UV_FAULT_LIMIT and IOUT_OC is not present. However, setting TON_MAX_FAULT_LIMIT to a value of 0 is not recommended. TIME-BASED SEQUENCING The default mode for sequencing the outputs on and off is time-based. Each output is enabled after waiting TON_ DELAY amount of time following either a RUN pin going high, a PMBus command to turn on or the VIN rising above a preprogrammed voltage. Off sequencing is handled in a similar way. To assure proper sequencing, make sure all ICs connect the SHARE_CLK pin together and RUN pins together. If the RUN pins cannot be connected together for some reasons, set bit 2 of MFR_CHAN_ CONFIG to 1. This bit requires the SHARE_CLK pin to be clocking before the power supply output can start. When the RUN pin is pulled low, the LTM4680 will hold the pin low for the MFR_ RESTART_DELAY. The minimum MFR_RESTART_ DELAY is TOFF_DELAY + TOFF_FALL + 136ms. This delay assures proper sequencing of all rails. The LTM4680 calculates this delay internally and will not process a shorter delay. However, a longer commanded MFR_RESTART_ DELAY can be used by the part. The maximum allowed value is 65.52 seconds. VOLTAGE-BASED SEQUENCING The sequence can also be voltage-based. As shown in Figure 4, The PGOODn pin is asserted when the UV Rev. B For more information www.analog.com LTM4680 OPERATION threshold is exceeded for each output. It is possible to feed the PGOOD pin from one LTM4680 into the RUN pin of the next LTM4680 in the sequence, especially across multiple LTM4680s. The PGOODn has a 100µs filter. If the VOUT voltage bounces around the UV threshold for a long period of time it is possible for the PGOODn output to toggle more than once. To minimize this problem, set the TON_RISE time under 100ms. If a fault in the string of rails is detected, only the faulted rail and downstream rails will fault off. The rails in the string of devices in front of the faulted rail will remain on unless commanded off. START PGOOD0 RUN 0 LTM4680 RUN 1 PGOOD1 RUN 0 PGOOD0 LTM4680 RUN 1 PGOOD1 There are two ways to respond to faults; which are retry mode and latched off mode. In retry mode, the controller responds to a fault by shutting down and entering the inactive state for a programmable delay time (MFR_RETRY_DELAY). This delay minimizes the duty cycle associated with autonomous retries if the fault that causes the shutdown disappears once the output is disabled. The retry delay time is determined by the longer of the MFR_RETRY_ DELAY command or the time required for the regulated output to decay below 12.5% of the programmed value. If multiple outputs are controlled by the same FAULTn pin, the decay time of the faulted output determines the retry delay. If the natural decay time of the output is too long, it is possible to remove the voltage requirement of the MFR_RETRY_DELAY command by asserting bit 0 of MFR_CHAN_CONFIG. Alternatively, latched off mode means the controller remains latched-off following a fault and clearing requires user intervention such as toggling RUNn or commanding the part OFF then ON. 4680 F04 TO NEXT CHANNEL IN THE SEQUENCE Figure 4. Event (Voltage) Based Sequencing SHUTDOWN The LTM4680 supports two shutdown modes. The first mode is closed-loop shutdown response, with user defined turn-off delay (TOFF_DELAY) and ramp down rate (TOFF_FALL). The controller will maintain the mode of operation for TOFF_FALL. The second mode is discontinuous conduction mode, the controller will not draw current from the load and the fall time will be set by the output capacitance and load current, instead of TOFF_FALL. The shutdown occurs in response to a fault condition or loss of SHARE_CLK (if bit 2 of MFR_CHAN_ CONFIG is set to a 1) or VIN falling below the VIN_OFF threshold or FAULT pulled low externally (if the MFR_FAULT_ RESPONSE is set to inhibit). Under these conditions, the power stage is disabled in order to stop the transfer of energy to the load as quickly as possible. The shutdown state can be entered from the soft-start or active regulation states or through user intervention. LIGHT-LOAD CURRENT OPERATION The LTM4680 has two modes of operation: high efficiency discontinuous conduction mode or forced continuous conduction mode. Mode selection is done using the MFR_PWM _MODE command (discontinuous conduction is always the start-up mode, forced continuous is the default running mode). If a controller is enabled for discontinuous operation, the inductor current is not allowed to reverse. The reverse current comparator’s output turns off the bottom MOSFET just before the inductor current reaches zero, preventing it from reversing and going negative. In forced continuous operation, the inductor current is allowed to reverse at light loads or under large transient conditions. The peak inductor current is determined solely by the voltage on the COMPn pins. In this mode, the efficiency at light loads is lower than in discontinuous mode operation. However, continuous mode exhibits lower output ripple and less interference with audio circuitry, but may result in reverse inductor current, which can cause the input supply to boost. The VIN_OV_FAULT_LIMIT can detect this and turn off the offending channel. However, Rev. B For more information www.analog.com 27 LTM4680 OPERATION this fault is based on an ADC read and can take up to tCONVERT to detect. If there is a concern about the input supply boosting, keep the part in discontinuous conduction mode. PWM control pins will also apply. Both channels must be off before the FREQUENCY_SWITCH and MFR_PWM_ CONFIG commands can be written to the LTM4680. If the part is set to discontinuous mode operation, as the inductor average current increases, the controller will automatically modify the operation from discontinuous mode to continuous mode. The phase relationships and frequency options provide for numerous application options. Multiple LTM4680 modules can be synchronized to realize a PolyPhase array. In this case the phases should be separated by 360/n degrees, where n is the number of phases driving the output voltage rail. SWITCHING FREQUENCY AND PHASE The switching frequency of the PWM can be established with an internal oscillator or an external time base. The internal phase-locked loop (PLL) synchronizes the PWM control to this timing reference with proper phase relation, whether the clock is provided internally or externally. The device can also be configured to provide the master clock to other devices through PMBus command, NVM setting, or external configuration resistors as outlined in Table 3. As clock master, the LTM4680 will drive its open-drain SYNC pin at the selected rate with a pulse width of 500ns. An external pull-up resistor between SYNC and VDD33 is required in this case. Only one device connected to SYNC should be designated to drive the pin. The LTM4680 will automatically revert to an external SYNC input, disabling its own SYNC, as long as the external SYNC frequency is greater than 80% of the programmed SYNC frequency. The external SYNC input shall have a duty cycle between 20% and 80%. Whether configured to drive SYNC or not, the LTM4680 can continue PWM operation using its own internal oscillator if an external clock signal is subsequently lost. The device can also be programmed to always require an external oscillator for PWM operation by setting bit 4 of MFR_CONFIG_ALL. The status of the SYNC driver circuit is indicated by bit 10 of MFR_PADS. The MFR_PWM_CONFIG command can be used to configure the phase of each channel. Desired phase can also be set from EEPROM or external configuration resistors as outlined in Table 3. Designated phase is the relationship between the falling edge of SYNC and the internal clock edge that sets the PWM latch to turn on the top power switch. Additional small propagation delays to the 28 PWM LOOP COMPENSATION The internal PWM loop compensation resistors RCOMPna of the LTM4680 can be adjusted using bit[4:0] of the MFR_PWM_COMP command. The transconductance (gm) of the LTM4680 PWM error amplifier can be adjusted using bit[7:5] of the MFR_ PWM_COMP command. These two loop compensation parameters can be programmed when device is in operation. Refer to the Programmable Loop Compensation subsection in the Applications Information section for further details. OUTPUT VOLTAGE SENSING Both channels in LTM4680 have differential amplifiers, which allow the remote sensing of the load voltage between V+ and V– pins. The telemetry ADC is also fully differential and makes measurements between VOSNSn+ and VOSNSn-voltages for both channels at the V+ and V– pins, respectively. The maximum allowed 3.6V, but the LTM4680 design is limited to 3.3V. INTVCC/EXTVCC POWER Power for the internal top and bottom MOSFET drivers and most other internal circuitry is derived from the INTVCC pin. When the EXTVCC pin is shorted to GND or tied to a voltage less than 4.7V, an internal 5.5V linear regulator supplies INTVCC power from VIN. If EXTVCC is taken above 4.8V and VIN is higher than 7.0V, the 5.5V regulator is turned off and an internal switch is turned on, connecting EXTVCC. Using the EXTVCC allows the INTVCC power to be derived from a high efficiency external source Rev. B For more information www.analog.com LTM4680 OPERATION such as a switching regulator output. EXTVCC can provide power to the internal 3.3V linear regulator even when VIN is not present, which allows the LTM4680 to be initialized and programmed even without main power being applied. The INTVCC regulator is powered from the SVIN pin, the power through the IC is equal to SVIN • IINTVCC. The gate charge current is dependent on operating frequency. The INTVCC regulator can supply up to 100mA, and the typical INTVCC current for the LTM4680 is ~50mA. A 12V input voltage would equate to a difference of 7V drop across the internal controller, when multiplied by 50mA equals a 350mW power loss. This loss can be eliminated by providing an external 5V bias on the EXTVCC pin. Do not tie INTVCC on the LTM4680 to an external supply because INTVCC will attempt to pull the external supply high and hit current limit, significantly increasing the die temperature. For applications where VIN is 5V, tie the VIN and INTVCC pins together to the 5V input through a 1Ω or 2.2Ω resistor as shown in Test Circuit 2. OUTPUT CURRENT SENSING AND SUB MILLIOHM DCR CURRENT SENSING The LTM4680 use a unique sub-milliohm inductor current sensing technique that provides a high level signal to noise ratio while sensing very low signals in current mode operation. This enables higher conversion efficiencies with the use of the internal sub-milliohm inductors in heavy load applications. The current limit threshold can be accurately set with the MFR_PWM_MODE[7] for High and Low range (see page 90). The internal DCR sensing network, thus current limit are calculated based on the DCR of the inductor at room temperature. The DCR of the inductor has a large temperature coefficient, approximately 3800ppm/°C. The temperature coefficient of the inductor is written to the MFR_IOUT_ CAL_GAIN_TC register. The external temperature is sensed near the inductor and used to modify the internal current limit circuit to maintain an essentially constant current limit with temperature. The current sensed is then digitized by the LTM4680’s telemetry ADC with an input range of ±128mV, a noise floor of 7µVRMS, and a peak-peak noise of approximately 46.5µV. The LTM4680 computes the inductor current using the DCR value stored in the IOUT_CAL_ GAIN command and the temperature coefficient stored in command MFR_IOUT_CAL_GAIN_TC. The resulting current value is returned by the READ_IOUT command. INPUT CURRENT SENSING To sense the total input current consumed by the LTM4680’s power stages , a sense resistor is placed between the supply voltage and the drain of the top N-channel MOSFET. The IIN+ and IIN– pins are connected to the sense resistor. The filtered voltage is amplified by the internal high side current sense amplifier and digitized by the LTM4680’s telemetry ADC. The input current sense amplifier has three gain settings of 2x, 4x, and 8x set by the bits[6:5] of the MFR_PWM_CONFIG command. The maximum input sense voltage for the three gain settings is 50mV, 25mV, and 10mV respectively. The LTM4680 computes the input current using the internal RSENSE value stored in the IIN_CAL_GAIN command. The resulting measured power stage current is returned by the READ_IIN command. The LTM4680 uses a 1Ω resistor to measure the SVIN pin supply current being consumed by the LTM4680. This value is returned by the MFR_READ_ICHIP command. The chip current is calculated by using the 1Ω value stored in the MFR_ICHIP_CAL_GAIN command. Refer to the subsection titled Input Current Sense Amplifier in the Applications Information section for further details. PolyPhase LOAD SHARING Multiple LTM4680s can be arrayed in order to provide a balanced load-share solution by bussing the necessary pins. Figure 47 illustrates a 4-Phase design sharing connections required for load sharing. If an external oscillator is not provided, the SYNC pin should only be enabled on one of the LTM4680s. The other(s) should be programmed to disable SYNC using bit 4 of MFR_CONFIG_ALL. If an external oscillator is present, the chip with the SYNC pin enabled will detect the presence of the external clock and disable its output. Rev. B For more information www.analog.com 29 LTM4680 OPERATION Multiple channels need to tie all the VOSNSn+ pins together, and all the VOSNSn – pins together, COMPna and COMPnb pins together as well. Do not assert bit[4] of MFR_ CONFIG_ALL except in a PolyPhase application. The user must share the SYNC, SHARE_CLK, FAULT, and ALERT pins of these parts. Be sure to use pull-up resistors on SYNC, FAULT, SHARE_CLK and ALERT. EXTERNAL/INTERNAL TEMPERATURE SENSE Temperature is measured using the internal diodeconnected PNP transistors on either of the TSNS0b or TSNS1b pins corresponding to channel 0 or 1. TSNSnb pins should be connected to their respective TSNSna pins, and these returns are directly connected to the LTM4680 SGND pin. Two different currents are applied to the diode (nominally 2µA and 32µA) and the temperature is calculated from a ∆VBE measurement made with the internal 16-bit monitor ADC (see Figure 2 Block Diagram). The LTM4680 will only implement ∆VBE temperature sensing, therefore MFR_PWM_MODE bit[5] is reserved. CH0 and CH1 temperatures can be linked to CH0 only for adjusting the temperature compensated variables, and internal temperature monitoring. This frees up TSNS1a for an external/temperature sensing. RCONFIG (RESISTOR CONFIGURATION) PINS There are six input pins utilizing 1% resistors between these pins and SGND to select key operating parameters. The pins are ASEL, FSWPH_CFG, VOUT0_CFG, VOUT1_ CFG, VTRIM0_CFG, VTRIM1_CFG. If pins are floated, the value stored in the corresponding NVM command is used. If bit 6 of the MFR_CONFIG_ALL configuration command is asserted in NVM, the resistor input is ignored upon power-up except for ASEL which is always respected. The resistor configuration pins are only measured during a power-up reset or after a MFR_RESET or after a RESTORE_USER_ALL command is executed. The VOUTn_CFG pin settings are described in Table 1. These pins set the LTM4680 VOUT0 and VOUT1 output voltage coarse settings. If the pin is open, the VOUT_ COMMAND command is loaded from NVM to determine 30 the output voltage. The default setting is to have the switcher off unless the voltage configuration pins are installed. The VTRIMn_CFG pins in Table 2 are used to set the output voltage fine adjustment setting. Both combine to offer several distinct output voltages. The following parameters are set as a percentage of the output voltage if the RCONFIG pins are used to determine the output voltage: n n n n n n VOUT_OV_FAULT_LIMIT.....................................+10% VOUT_OV_WARN_LIMIT.....................................+7.5% VOUT_MAX..........................................................+7.5% VOUT_MARGIN_HIGH.........................................+5% VOUT_MARGIN_LOW..........................................–5% VOUT_UV_FAULT_LIMIT.....................................–7% The FSWPH_CFG pin settings are described in Table 3. This pin selects the switching frequency and phase of each channel. The phase relationships between the two channels and SYNC pin are determined in Table 3. To synchronize to an external clock, the part should be put into external clock mode (SYNC output disabled but frequency set to the nominal value). If no external clock is supplied, the part will clock at the programmed frequency. If the application is multiphase and the SYNC signal between chips is lost, the parts will not operate at the designed phase even if they are programmed and trimmed to the same frequency. This may increase the ripple voltage on the output, possibly produce undesirable operation. If the external SYNC signal is being generated internally and external SYNC is not selected, bit 10 of MFR_PADS will be asserted. If no frequency is selected and the external SYNC frequency is not present, a PLL_FAULT will occur. If the user does not wish to see the ALERT from a PLL_FAULT even if there is not a valid synchronization signal at power-up, the ALERT mask for PLL_FAULT must be written. See the description on SMBALERT_MASK for more details. If the SYNC pin is connected between multiple ICs only one of the ICs should have the SYNC pin enabled using the MFR_CONFIG_ALL[4] =1, and all other ICs should be configured to have the SYNC pin disabled with MFR_CONFIG_ALL[4] =0. The ASEL pin settings are described in Table 4. ASEL selects slave address for the LTM4680. For more detail, refer to Table 5. Rev. B For more information www.analog.com LTM4680 OPERATION NOTE: Per the PMBus specification, pin programmed parameters can be overridden by commands from the digital interface with the exception of ASEL which is always honored. Do not set any part address to 0x5A or 0x5B because these are global addresses and all parts will respond to them. Table 1. VOUTn_CFG Pin Strapping Look-Up Table for the LTM4680’s Output Voltage, Coarse Setting (Not Applicable if MFR_CONFIG_ALL[6] = 1b) Table 2. VTRIMn_CFG Pin Strapping Look-Up Table for the LTM4680’s Output Voltage, Fine Adjustment Setting (Not Applicable if MFR_CONFIG_ALL[6] = 1b) RVTRIMn_CFG* (kΩ) VTRIM (mV) FINE ADJUSTMENT TO VOUTn SETTING WHEN RESPECTIVE Open 0 32.4 99 22.6 86.625 74.25 15.4 61.875 RVOUTn_CFG* (kΩ) VOUTn (V) SETTING COARSE MFR_PWM_ MODEn[1] BIT 18.0 Open NVM NVM 12.7 49.5 32.4 NVM NVM 10.7 37.125 22.6 3.3 0 9.09 24.75 18.0 3.1 0 7.68 12.375 15.4 2.9 0 6.34 –12.375 12.7 2.7 0 5.23 –24.75 10.7 2.5 0, if VTRIMn > 0mV 1, if VTRIMn ≤ 0mV 4.22 –37.125 9.09 2.3 1 3.24 –49.5 7.68 2.1 1 2.43 –61.875 6.34 1.9 1 1.65 –74.25 5.23 1.7 1 0.787 –86.625 4.22 1.5 1 0 –99 3.24 1.3 1 2.43 1.1 1 1.65 0.9 1 0.787 0.7 1 0 0.5 1 *RVOUTn_CFG value indicated is nominal. Select RVOUTn_CFG from a resistor vendor such that its value is always within 3% of the value indicated in the table. Take into account resistor initial tolerance, T.C.R. and resistor operating temperatures, soldering heat/IR reflow, and endurance of the resistor over its lifetime. Thermal shock/cycling, moisture (humidity) and other effects (depending on one’s specific application) could also affect RVOUTn_CFG’s value over time. All such effects must be taken into account in order for resistor pin strapping to yield the expected result at every SVIN power-up and/or every execution of MFR_RESET or RESTORE_ USER_ALL, over the lifetime of one’s product. *RVTRIMn_CFG value indicated is nominal. Select RVTRIMn_CFG from a resistor vendor such that its value is always within 3% of the value indicated in the table. Take into account resistor initial tolerance, T.C.R. and resistor operating temperatures, soldering heat/IR reflow, and endurance of the resistor over its lifetime. Thermal shock/cycling, moisture (humidity) and other effects (depending on one’s specific application) could also affect RVTRIMn_CFG’s value over time. All such effects must be taken into account in order for resistor pin strapping to yield the expected result at every SVIN power-up and/or every execution of MFR_RESET, or RESTORE_USER_ALL over the lifetime of one’s product. Rev. B For more information www.analog.com 31 LTM4680 OPERATION Table 3. FSWPH_CFG Pin Strapping Look-Up Table to Set the LTM4680’s Switching Frequency and Channel Phase-Interleaving Angle (Not Applicable if MFR_CONFIG_ALL[6] = 1b) RFSWPH_CFG* (kΩ) SWITCHING FREQUENCY (kHz) θSYNC TO θ0 θSYNC TO θ1 bits [2:0] of MFR_PWM_CONFIG bit [4] of MFR_CONFIG_ALL Open NVM; LTM4680 Default = 500 NVM; LTM4680 Default = 0° NVM; LTM4680 Default = 180° NVM; LTM4680 Default = 000b NVM; LTM4680 Default = 0b 32.4 250 0° 180° 000b 0b 22.6 350 0° 180° 000b 0b 18.0 425 0° 180° 000b 0b 15.4 575 0° 180° 000b 0b 12.7 650 0° 180° 000b 0b 10.7 750 0° 180° 000b 0b 7.68 500 120° 240° 100b 0b 6.34 500 90° 270° 001b 0b 5.23 External** 0° 240° 010b 1b 4.22 External** 0° 120° 011b 1b 3.24 External** 60° 240° 101b 1b 2.43 External** 120° 300° 110b 1b 1.65 External** 90° 270° 001b 1b 0.787 External** 0° 180° 000b 1b 0 External** 120° 240° 100b 1b *RFSWPH_CFG value indicated is nominal. Select RFSWPH_CFG from a resistor vendor such that its value is always within 3% of the value indicated in the table. Take into account resistor initial tolerance, T.C.R. and resistor operating temperatures, soldering heat/IR reflow, and endurance of the resistor over its lifetime. Thermal shock/cycling, moisture (humidity) and other effects (depending on one’s specific application) could also affect RFSWPH_CFG’s value over time. All such effects must be taken into account in order for resistor pin-strapping to yield the expected result at every SVIN power-up and/or every execution of MFR_RESET or RESTORE_USER_ALL, over the lifetime of one’s product. **External setting corresponds to FREQUENCY_SWITCH (Register 0x33) value set to 0x0000; the device synchronizes its switching frequency to that of the clock provided on the SYNC pin, provided MFR_CONFIG_ALL[4] = 1b. 32 Rev. B For more information www.analog.com LTM4680 OPERATION Table 4. ASEL Pin Strapping Look-Up Table to Set the LTM4680’s Slave Address (Applicable Regardless of MFR_CONFIG_ALL[6] Setting) Table 5. LTM4680 MFR_ADDRESS Command Examples Expressed in 7- and 8-Bit Addressing HEX DEVICE ADDRESS BIT RASEL* (kΩ) SLAVE ADDRESS Open 100_1111_R/W DESCRIPTION 7-BIT 8-BIT 7 6 5 4 3 2 1 0 R/W 100_1111_R/W Rail4 0x5A 0xB4 0 1 0 1 1 0 1 0 0 22.6 100_1110_R/W Global4 0x5B 0xB6 0 1 0 1 1 0 1 1 0 18.0 100_1101_R/W Default 0x4F 0x9E 0 1 0 0 1 1 1 1 0 15.4 100_1100_R/W Example 1 0x40 0x80 0 1 0 0 0 0 0 0 0 12.7 100_1011_R/W Example 2 0x41 0x82 0 1 0 0 0 0 0 1 0 100_1010_R/W Disabled2,3 1 0 0 0 0 0 0 0 0 9.09 100_1001_R/W 7.68 100_1000_R/W Note 1: This table can be applied to the MFR_RAIL_ADDRESSn commands, but not the MFR_ADDRESS command. 6.34 100_0111_R/W 5.23 100_0110_R/W 4.22 100_0101_R/W 3.24 100_0100_R/W 2.43 100_0011_R/W 1.65 100_0010_R/W 0.787 100_0001_R/W 0 100_0000_R/W 32.4 10.7 Where: R/W = Read/Write bit in control byte All PMBus device addresses listed in the specification are 7 bits wide unless otherwise noted. Note: The LTM4680 will always respond to slave address 0x5A and 0x5B regardless of the NVM or ASEL resistor configuration values. *RCFG value indicated is nominal. Select RCFG from a resistor vendor such that its value is always within 3% of the value indicated in the table. Take into account resistor initial tolerance, T.C.R. and resistor operating temperatures, soldering heat/IR reflow, and endurance of the resistor over its lifetime. Thermal shock cycling, moisture (humidity) and other effects (depending on one’s specific application) could also affect RCFG’s value over time. All such effects must be taken into account in order for resistor pin-strapping to yield the expected result at every SVIN power-up and/or every execution of MFR_RESET or RESTORE_USER_ALL, over the lifetime of one’s product. Note 2: A disabled value in one command does not disable the device, nor does it disable the global address. Note 3: A disabled value in one command does not inhibit the device from responding to device addresses specified in other commands. Note 4: It is not recommended to write the value 0x00, 0x0C (7-bit), 0x5A (7-bit), 0x5B (7-bit) or 0x7C(7-bit) to the MFR_CHANNEL_ADDRESSn or the MFR_RAIL_ADDRESSn commands. FAULT DETECTION AND HANDLING A variety of fault and warning reporting and handling mechanisms are available. Fault and warning detection capabilities include: Input OV Fault Protection and UV Warning n Average Input OC Warning n Output OV/UV Fault and Warning Protection n Output OC Fault and Warning Protection n Internal Control Die and Internal Module Overtemperature Fault and Warning Protection n Internal Undertemperature Fault and Warning Protection n CML Fault (Communication, Memory or Logic) n External Fault Detection via the Bidirectional FAULTn Pins n In addition, the LTM4680 can map any combination of fault indicators to their respective FAULTn pin using the propagate FAULTn response commands, MFR_FAULT_ PROPAGATE. Typical usage of a FAULTn pin is as a driver for an external crowbar device, overtemperature alert, Rev. B For more information www.analog.com 33 LTM4680 OPERATION overvoltage alert or as an interrupt to cause a microcontroller to poll the fault commands. Alternatively, the FAULTn pins can be used as inputs to detect external faults downstream of the controller that require an immediate response. Any fault or warning event will always cause the ALERT pin to assert low unless the fault or warning is masked by the SMBALERT_MASK. The pin will remain asserted low until the CLEAR_FAULTS command is issued, the fault bit is written to a 1 or bias power is cycled or a MFR_RESET command is issued, or the RUN pins are toggled OFF/ ON or the part is commanded OFF/ON via PMBus or an ARA command operation is performed. The MFR_FAULT_ PROPAGATE command determines if the FAULT pins are pulled low when a fault is detected. Output and input fault event handling is controlled by the corresponding fault response byte as specified in Tables 14 thru 18. Shutdown recovery from these types of faults can either be autonomous or latched. For autonomous recovery, the faults are not latched, so if the fault conditions not present after the retry interval has elapsed, a new soft-start is attempted. If the fault persists, the controller will continue to retry. The retry interval is specified by the MFR_RETRY_DELAY command and prevents damage to the regulator components by repetitive power cycling, assuming the fault condition itself is not immediately destructive. The MFR_ RETRY_DELAY must be greater than 120ms. It can not exceed 83.88 seconds. Status Registers and ALERT Masking Figure 5 summarizes the internal LTM4680 status registers accessible by PMBus command. These contain indication of various faults, warnings and other important operating conditions. As shown, the STATUS_BYTE and STATUS_WORD commands also summarize contents of other status registers. Refer to PMBus Command Details for specific information. NONE OF THE ABOVE in the STATUS_BYTE indicates that one or more of the bits in the most-significant nibble of STATUS_WORD are also set. 34 In general, any asserted bit in a STATUS_x register also pulls the ALERT pin low. Once set, ALERT will remain low until one of the following occurs. A CLEAR_FAULTS or MFR_RESET Command Is Issued n The Related Status Bit Is Written to a One n The Faulted Channel Is Properly Commanded Off and Back On n The LTM4680 Successfully Transmits Its Address During a PMBus ARA n Bias Power Is Cycled n With some exceptions, the SMBALERT_MASK command can be used to prevent the LTM4680 from asserting ALERT for bits in these registers on a bit-by-bit basis. These mask settings are promoted to STATUS_WORD and STATUS_BYTE in the same fashion as the status bits themselves. For example, if ALERT is masked for all bits in channel 0 STATUS_VOUT, then ALERT is effectively masked for the VOUT bit in STATUS_WORD for PAGE 0. The BUSY bit in STATUS_BYTE also asserts ALERT low and cannot be masked. This bit can be set as a result of various internal interactions with PMBus communication. This fault occurs when a command is received that cannot be safely executed with one or both channels enabled. As discussed in the Application Information, BUSY faults can be avoided by polling MFR_COMMON before executing some commands. If masked faults occur immediately after power up, ALERT may still be pulled low because there has not been time to retrieve all of the programmed masking information from EEPROM. Status information contained in MFR_COMMON and MFR_PADS can be used to further debug or clarify the contents of STATUS_BYTE or STATUS_WORD as shown, but the contents of these registers do not affect the state of the ALERT pin and may not directly influence bits in STATUS_BYTE or STATUS_WORD. Rev. B For more information www.analog.com LTM4680 OPERATION STATUS_WORD STATUS_VOUT* 7 6 5 4 3 2 1 0 VOUT_OV Fault VOUT_OV Warning VOUT_UV Warning VOUT_UV Fault VOUT_MAX Warning TON_MAX Fault TOFF_MAX Warning (reads 0) 15 14 13 12 11 10 9 8 VOUT IOUT INPUT MFR_SPECIFIC POWER_GOOD# (reads 0) (reads 0) (reads 0) 7 6 5 4 3 2 1 0 BUSY OFF VOUT_OV IOUT_OC (reads 0) TEMPERATURE CML NONE OF THE ABOVE STATUS_BYTE (PAGED) STATUS_IOUT 7 6 5 4 3 2 1 0 IOUT_OC Fault (reads 0) IOUT_OC Warning (reads 0) (reads 0) (reads 0) (reads 0) (reads 0) MFR_COMMON 7 6 5 4 3 2 1 0 STATUS_TEMPERATURE OT Fault OT Warning (reads 0) UT Fault (reads 0) (reads 0) (reads 0) (reads 0) (PAGED) STATUS_CML 7 6 5 4 3 2 1 0 Chip Not Driving ALERT Low Chip Not Busy Internal Calculations Not Pending Output Not In Transition EEPROM Initialized (reads 0) SHARE_CLK_LOW WP Pin High Invalid/Unsupported Command Invalid/Unsupported Data Packet Error Check Failed Memory Fault Detected Processor Fault Detected (reads 0) Other Communication Fault Other Memory or Logic Fault Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved EEPROM ECC Status Reserved Reserved Reserved Reserved DESCRIPTION 7 6 5 4 3 2 1 0 Internal Temperature Fault Internal Temperature Warning EEPROM CRC Error Internal PLL Unlocked Fault Log Present VDD33 UV or OV Fault VOUT Short Cycled FAULT Pulled Low By External Device (PAGED) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 VDD33 OV Fault VDD33 UV Fault (reads 0) (reads 0) Invalid ADC Result(s) SYNC Clocked by External Source Channel 1 is POWER_GOOD Channel 0 is POWER_GOOD LTM4680 Forcing RUN1 Low LTM4680 Forcing RUN0 Low RUN1 Pin State RUN0 Pin State LTM4680 Forcing FAULT1 Low LTM4680 Forcing FAULT0 Low FAULT1 Pin State FAULT0 Pin State MFR_PADS MFR_INFO 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 VIN_OV Fault (reads 0) VIN_UV Warning (reads 0) Unit Off for Insuffcient VIN (reads 0) IIN_OC Warning (reads 0) STATUS_MFR_SPECIFIC (PAGED) (PAGED) 7 6 5 4 3 2 1 0 STATUS_INPUT 7 6 5 4 3 2 1 0 4680 F05 MASKABLE GENERATES ALERT BIT CLEARABLE General Fault or Warning Event General Non-Maskable Event Dynamic Status Derived from Other Bits Yes No No No Yes Yes No Not Directly Yes Yes No No Figure 5. LTM4680 Status Register Summary Rev. B For more information www.analog.com 35 LTM4680 OPERATION Mapping Faults to FAULT Pins Channel-to-channel fault (including channels from multiple LTM4680s) dependencies can be created by connecting FAULTn pins together. In the event of an internal fault, one or more of the channels is configured to pull the bussed FAULTn pins low. The other channels are then configured to shut down when the FAULTn pins are pulled low. For autonomous group retry, the faulted channel is configured to let go of the FAULTn pin(s) after a retry interval, assuming the original fault has cleared. All the channels in the group then begin a soft-start sequence. If the fault response is LATCH_OFF, the FAULTn pin remains asserted low until either the RUN pin is toggled OFF/ON or the part is commanded OFF/ON. The toggling of the RUN either by the pin or OFF/ON command will clear faults associated with the channel. If it is desired to have all faults cleared when either RUN pin is toggled or, set bit 0 of MFR_CONFIG_ALL to a 1. The status of all faults and warnings is summarized in the STATUS_WORD and STATUS_BYTE commands. Additional fault detection and handling capabilities are: Power Good Pins The PGOODn pins of the LTM4680 are connected to the open drains of internal MOSFETs. The MOSFETs turn on and pull the PGOODn pins low when the channel output voltage is not within the channel’s UV and OV voltage thresholds. During TON_DELAY and TON_RISE sequencing, the PGOODn pin is held low. The PGOODn pin is also pulled low when the respective RUNn pin is low. The PGOODn pin response is deglitched by an internal 100µs digital filter. The PGOODn pin and PGOOD status may be different at times due to communication latency of up to 10µs. CRC Protection The integrity of the NVM memory is checked after a power on reset. A CRC error will prevent the controller from leaving the inactive state. If a CRC error occurs, the CML bit is set in the STATUS_BYTE and STATUS_WORD commands, the appropriate bit is set in the STATUS_MFR_SPECIFIC command, and the ALERT pin will be pulled low. NVM 36 repair can be attempted by writing the desired configuration to the controller and executing a STORE_USER_ALL command followed by a CLEAR_FAULTS command. The LTM4680 manufacturing section of the NVM is mirrored. If both copies are corrupted, the “NVM CRC Fault” in the STATUS_MFR_SPECIFIC command is set. If this bit remains set after being cleared by issuing a CLEAR_ FAULTS or writing a 1 to this bit, an irrecoverable internal fault has occurred. The user is cautioned to disable both output power supply rails associated with this specific part. There are no provisions for field repair of NVM faults in the manufacturing section. SERIAL INTERFACE The LTM4680 serial interface is a PMBus compliant slave device and can operate at any frequency between 10kHz and 400kHz. The address is configurable using either the NVM or an external resistor. In addition the LTM4680 always responds to the global broadcast address of 0x5A (7-bit) or 0x5B (7-bit). The serial interface supports the following protocols defined in the PMBus specifications: 1) send command, 2) write byte, 3) write word, 4) group, 5) read byte, 6) read word and 7) read block. 8) write block. All read operations will return a valid PEC if the PMBus master requests it. If the PEC_REQUIRED bit is set in the MFR_CONFIG_ALL command, the PMBus write operations will not be acted upon until a valid PEC has been received by the LTM4680. Communication Protection PEC write errors (if PEC_REQUIRED is active), attempts to access unsupported commands, or writing invalid data to supported commands will result in a CML fault. The CML bit is set in the STATUS_BYTE and STATUS_WORD commands, the appropriate bit is set in the STATUS_CML command, and the ALERT pin is pulled low. DEVICE ADDRESSING The LTM4680 offers five different types of addressing over the PMBus interface, specifically: 1) global, 2) device, 3) rail addressing and 4) alert response address (ARA). Rev. B For more information www.analog.com LTM4680 OPERATION Global addressing provides a means of the PMBus master to address all LTM4680 devices on the bus. The LTM4680 global address is fixed 0x5A (7-bit) or 0xB4 (8-bit) and cannot be disabled. Commands sent to the global address act the same as if PAGE is set to a value of 0xFF. Commands sent are written to both channels simultaneously. Global command 0x5B (7-bit) or 0xB6 (8-bit) is paged and allows channel specific command of all LTM4680 devices on the bus. Other ADI device types may respond at one or both of these global addresses. Reading from global addresses is strongly discouraged. The IIN and IOUT overcurrent monitors are performed by ADC readings and calculations. Thus these values are based on average currents and can have a time latency of up to tCONVERT. The IOUT calculation accounts for the DCR and their temperature coefficient. The input current is equal to the voltage measured across the RSENSE resistor divided by the resistors value as set with the MFR_RVIN command. If this calculated input current exceeds the IN_OC_WARN_LIMIT the ALERT pin is pulled low and the IIN_OC_WARN bit is asserted in the STATUS_INPUT command. Device addressing provides the standard means of the PMBus master communicating with a single instance of an LTM4680. The value of the device address is set by a combination of the ASEL configuration pin and the MFR_ ADDRESS command. When this addressing means is used, the PAGE command determines the channel being acted upon. Device addressing can be disabled by writing a value of 0x80 to the MFR_ADDRESS. The digital processor within the LTM4680 provides the ability to ignore the fault, shut down and latch off or shut down and retry indefinitely (hiccup). The retry interval is set in MFR_RETRY_ DELAY and can be from 120ms to 83.88 seconds in 1ms increments. The shutdown for OV/UV and OC can be done immediately or after a user selectable deglitch time. Rail addressing provides a means for the bus master to simultaneously communicate with all channels connected together to produce a single output voltage (PolyPhase). While similar to global addressing, the rail address can be dynamically assigned with the paged MFR_RAIL_ ADDRESS command, allowing for any logical grouping of channels that might be required for reliable system control. Reading from rail addresses is also strongly discouraged. All four means of PMBus addressing require the user to employ disciplined planning to avoid addressing conflicts. Communication to LTM4680 devices at global and rail addresses should be limited to command write operations. RESPONSES TO VOUT AND IIN/IOUT FAULTS A programmable overvoltage comparator (OV) guards against transient overshoots as well as long-term overvoltages at the output. In such cases, the top MOSFET is turned off and the bottom MOSFET is turned on. However, the reverse output current is monitored while device is in OV fault. When it reaches the limit, both top and bottom MOSFETs are turned off. The top and bottom MOSFETs will keep their state until the overvoltage condition is cleared regardless of the PMBus VOUT_OV_ FAULT_RESPONSE command byte value. This hardware level fault response delay is typically 2µs from the overvoltage condition to BG asserted high. Using the VOUT_ OV_FAULT_RESPONSE command, the user can select any of the following behaviors: OV Pull-Down Only (OV Cannot Be Ignored) n VOUT OV and UV conditions are monitored by comparators. The OV and UV limits are set in three ways: As a Percentage of the VOUT if Using the Resistor Configuration Pins n In NVM if Either Programmed at the Factory or Through the GUI n Output Overvoltage Fault Response n Shut Down (Stop Switching) Immediately—Latch Off Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY n Either the Latch Off or Retry fault responses can be deglitched in increments of (0-7) • 10µs. See Table 15. By PMBus Command n Rev. B For more information www.analog.com 37 LTM4680 OPERATION Output Undervoltage Response Ignore FAULT_LIMIT is 10µs. If the VOUT_UV_FAULT _LIMIT is not reached within the TON_MAX_FAULT_LIMIT time, the response of this fault is determined by the value of the TON_MAX_FAULT_RESPONSE command value. This response may be one of the following: Shut Down Immediately—Latch Off n The response to an undervoltage comparator output can be the following: n Ignore n Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY. n The UV responses can be deglitched. See Table 16. Peak Output Overcurrent Fault Response Due to the current mode control algorithm, peak output current across the inductor is always limited on a cycleby-cycle basis. The value of the peak current limit is specified in Electrical Characteristics table. The current limit circuit operates by limiting the COMPn maximum voltage. Since internal DCR sensing is used, the COMPn maximum voltage has a temperature dependency directly proportional to the TC of the DCR of the inductor. The LTM4680 automatically monitors the external temperature sensors and modifies the maximum allowed COMPn to compensate for this term. The IOUT_OC_FAULT_LIMIT section provides data points for IOUT Limiting on page 90. The overcurrent fault processing circuitry can execute the following behaviors: n Shut Down (Stop Switching) Immediately—Latch Off Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY. n This fault response is not deglitched. A value of 0 in TON_MAX_FAULT_LIMIT means the fault is ignored. The TON_MAX_FAULT_LIMIT should be set longer than the TON_RISE time. It is recommended TON_MAX_FAULT_ LIMIT always be set to a non-zero value, otherwise the output may never come up and no flag will be set to the user. See Table 19. RESPONSES TO VIN OV FAULTS VIN overvoltage is measured with the ADC. The response is naturally deglitched by the 100ms typical response time of the ADC. The fault responses are: Ignore n Shut Down Immediately—Latch Off n Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY. See Table 19. n Current Limit Indefinitely n Shut Down Immediately—Latch Off n Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY. n The overcurrent responses can be deglitched in increments of (0-7) • 16ms. See Table 17. RESPONSES TO TIMING FAULTS TON_MAX_FAULT_LIMIT is the time allowed for VOUT to rise and settle at start-up. The TON_MAX_FAULT_LIMIT condition is predicated upon detection of the VOUT_UV_ FAULT_LIMIT as the output is undergoing a SOFT_START sequence. The TON_MAX_ FAULT_LIMIT time is started after TON_DELAY has been reached and a SOFT_START sequence is started. The resolution of the TON_MAX_ 38 RESPONSES TO OT/UT FAULTS Internal Overtemperature Fault Response An internal temperature sensor protects against NVM damage. Above 85°C, no writes to NVM are recommended. Above 130°C, the internal overtemperature warn threshold is exceeded and the part disables the NVM and does not re-enable until the temperature has dropped to 125°C. When the die temperature exceed 160°C the internal temperature fault response is enabled and the PWM is disabled until the die temperature drops below 150°C. Temperature is measured by the ADC. Internal temperature faults cannot be ignored. Internal temperature limits cannot be adjusted by the user. See Table 18. Rev. B For more information www.analog.com LTM4680 OPERATION External Overtemperature and Undertemperature Fault Response Two internal temperature sensors are used to sense the temperature of critical circuit elements like inductors and power MOSFETs on each channel. The OT_FAULT_ RESPONSE and UT_FAULT_ RESPONSE commands are used to determine the appropriate response to an overtemperature and under temperature condition, respectively. If no external sense elements are used (not recommended) set the UT_FAULT_ RESPONSE to ignore—and set the UT_FAULT_LIMIT to 275°C. The fault responses are: Ignore n Shut Down Immediately—Latch Off n Shut Down Immediately—Retry Indefinitely at the Time n Interval Specified in MFR_RETRY_DELAY. See Table 19. RESPONSES TO INPUT OVERCURRENT AND OUTPUT UNDERCURRENT FAULTS Input overcurrent and output undercurrent are measured with the ADC. The fault responses are: FAULT LOGGING The LTM4680 has fault logging capability. Data is logged into memory in the order shown in Table 19. The data is stored in a continuously updated buffer in RAM. When a fault event occurs, the fault log buffer is copied from the RAM buffer into NVM. Fault logging is allowed at temperatures above 85°C; however, retention of 10 years is not guaranteed. When the die temperature exceeds 130°C the fault logging is delayed until the die temperature drops below 125°C. The fault log data remains in NVM until a MFR_FAULT _LOG_CLEAR command is issued. Issuing this command re-enables the fault log feature. Before reenabling fault log, be sure no faults are present and a CLEAR_FAULTS command has been issued. When the LTM4680 powers-up or exits its reset state, it checks the NVM for a valid fault log. If a valid fault log exists in NVM, the “Valid Fault Log” bit in the STATUS_ MFR_SPECIFIC command will be set and an ALERT event will be generated. Also, fault logging will be blocked until the LTM4680 has received a MFR_FAULT_LOG_CLEAR command before fault logging will be re-enabled. Shut Down Immediately—Latch Off The information is stored in EEPROM in the event of any fault that disables the controller on either channel. A FAULTn being externally pulled low will not trigger a fault logging event. Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY. BUS TIMEOUT PROTECTION Ignore n n n RESPONSES TO EXTERNAL FAULTS When either FAULTn pin is pulled low, the OTHER bit is set in the STATUS_WORD command, the appropriate bit is set in the STATUS_MFR_SPECIFIC command, and the ALERT pin is pulled low. Responses are not deglitched. Each channel can be configured to ignore or shut down then retry in response to its FAULTn pin going low by modifying the MFR_FAULT_RESPONSE command. To avoid the ALERT pin asserting low when FAULT is pulled low, assert bit 1 of MFR_CHAN_CONFIG, or mask the ALERT using the SMBALERT_MASK command. The LTM4680 implements a timeout feature to avoid persistent faults on the serial interface. The data packet timer begins at the first START event before the device address write byte. Data packet information must be completed within 30ms or the LTM4680 will three-state the bus and ignore the given data packet. If more time is required, assert bit 3 of MFR_CONFIG_ALL to allow typical bus timeouts of 255ms. Data packet information includes the device address byte write, command byte, repeat start event (if a read operation), device address byte read (if a read operation), all data bytes and the PEC byte if applicable. The LTM4680 allows longer PMBus timeouts for block read data packets. This timeout is proportional to the length of the block read. The additional block read timeout Rev. B For more information www.analog.com 39 LTM4680 OPERATION applies primarily to the MFR_FAULT_LOG command. The timeout period defaults to 32ms. The user is encouraged to use as high a clock rate as possible to maintain efficient data packet transfer between all devices sharing the serial bus interface. The LTM4680 supports the full PMBus frequency range from 10kHz to 400kHz. SIMILARITY BETWEEN PMBus, SMBus AND I2C 2-WIRE INTERFACE The PMBus 2-wire interface is an incremental extension of the SMBus. SMBus is built upon I2C with some minor differences in timing, DC parameters and protocol. The PMBus/SMBus protocols are more robust than simple I2C byte commands because PMBus/SMBus provide timeouts to prevent persistent bus errors and optional packet error checking (PEC) to ensure data integrity. In general, a master device that can be configured for I2C communication can be used for PMBus communication with little or no change to hardware or firmware. Repeat start (restart) is not supported by all I2C controllers but is required for SMBus/PMBus reads. If a general purpose I2C controller is used, check that repeat start is supported. The LTM4680 supports the maximum SMBus clock speed of 100kHz and is compatible with the higher speed PMBus specification (between 100kHz and 400kHz) if MFR_ COMMON polling or clock stretching is enabled. For robust communication and operation refer to the Note section in the PMBus command summary. Clock stretching is enabled by asserting bit 1 of MFR_CONFIG_ALL. For a description of the minor extensions and exceptions PMBus makes to SMBus, refer to PMBus Specification Part 1 Revision 1.2: Paragraph 5: Transport. For a description of the differences between SMBus and I2C, refer to System Management Bus (SMBus) Specification Version 2.0: Appendix B—Differences Between SMBus and I2C. 40 PMBus SERIAL DIGITAL INTERFACE The LTM4680 communicates with a host (master) using the standard PMBus serial bus interface. The Timing Diagram, Figure 6, shows the timing relationship of the signals on the bus. The two-bus lines, SDA and SCL, must be high when the bus is not in use. External pull-up resistors or current sources are required on these lines. The LTM4680 is a slave device. The master can communicate with the LTM4680 using the following formats: Master Transmitter, Slave Receiver n Master Receiver, Slave Transmitter n The following PMBus protocols are supported: Write Byte, Write Word, Send Byte n Read Byte, Read Word, Block Read, Block Write n Alert Response Address n Figures 7 to 24 illustrate the aforementioned PMBus protocols. All transactions support PEC and GCP (group command protocol). The Block Read supports 255 bytes of returned data. For this reason, the PMBus timeout may be extended when reading the fault log. Figure 7 is a key to the protocol diagrams in this section. PEC is optional. A value shown below a field in the following figures is mandatory value for that field. The data formats implemented by PMBus are: Master transmitter transmits to slave receiver. The transfer direction in this case is not changed. n n n Master reads slave immediately after the first byte. At the moment of the first acknowledgment (provided by the slave receiver) the master transmitter becomes a master receiver and the slave receiver becomes a slave transmitter. Combined format. During a change of direction within a transfer, the master repeats both a start condition and the slave address but with the R/W bit reversed. In this case, the master receiver terminates the transfer by generating a NACK on the last byte of the transfer and a STOP condition. Rev. B For more information www.analog.com LTM4680 OPERATION Refer to Figure 7 for a legend. Handshaking features are included to ensure robust system communication. Please refer to the PMBus Communication and Command Processing subsection of the Applications Information section for further details. SDA tf tLOW tr tSU(DAT) tHD(SDA) tf tSP tr tBUF SCL tHD(STA) tHD(DAT) tSU(STA) tHIGH tSU(STO) 4680 F06 START CONDITION REPEATED START CONDITION STOP CONDITION START CONDITION Figure 6. PMBus Timing Diagram Table 6. Abbreviations of Supported Data Formats PMBus TERMINOLOGY SPECIFICATION ADI REFERENCE TERMINOLOGY DEFINITION EXAMPLE Floating point 16-bit data: value = Y • 2N, b[15:0] = 0x9807 = 10011_000_0000_0111 value = 7 • 2–13 = 854E-6 L11 Linear Part II ¶7.1 Linear_5s_1s L16 Linear VOUT_MODE Part II ¶8.2 Linear_16u Floating point 16-bit data: value = Y • 2–12, where Y = b[15:0], an unsigned integer b[15:0] = 0x4C00 = 0100_1100_0000_0000 value = 19456 • 2–12 = 4.75 CF DIRECT Part II ¶7.2 Varies 16-bit data with a custom format defined in the detailed PMBus command description Often an unsigned or two’s compliment integer Reg Register Bits Part II ¶10.3 Reg Per-bit meaning defined in detailed PMBus command description PMBus STATUS_BYTE command ASC Text Characters Part II ¶22.2.1 ASCII ISO/IEC 8859-1 [A05] LTC (0x4C5443) where N = b[15:11] and Y = b[10:0], both two’s compliment binary integers Rev. B For more information www.analog.com 41 LTM4680 OPERATION FIGURES 7 TO 24 PMBus PROTOCOLS S START CONDITION Sr REPEATED START CONDITION Rd READ (BIT VALUE OF 1) Wr WRITE (BIT VALUE OF 0) A ACKNOWLEDGE (THIS BIT POSITION MAY BE 0 FOR AN ACK OR 1 FOR A NACK) P STOP CONDITION PEC PACKET ERROR CODE MASTER TO SLAVE SLAVE TO MASTER ... CONTINUATION OF PROTOCOL 4680 F07 Figure 7. PMBus Packet Protocol Diagram Element Key 1 7 S 1 1 SLAVE ADDRESS Rd/Wr A 1 P 4680 F08 Figure 8. Quick Command Protocol 1 7 S 1 1 8 1 1 SLAVE ADDRESS Wr A COMMAND CODE A P 4680 F09 Figure 9. Send Byte Protocol 1 S 7 1 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A 8 1 1 PEC A P 4680 F10 Figure 10. Send Byte Protocol with PEC 1 S 7 1 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A 8 1 1 DATA BYTE A P F11 Figure 11. Write Byte Protocol 1 S 7 1 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A 8 1 8 1 DATA BYTE A PEC A 1 P 4680 F12 Figure 12. Write Byte Protocol with PEC 1 S 7 1 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A 8 1 8 1 1 DATA BYTE LOW A DATA BYTE HIGH A P 4680 F13 Figure 13. Write Word Protocol 1 S 7 1 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A 8 1 8 1 8 1 1 DATA BYTE LOW A DATA BYTE HIGH A PEC A P 4680 F14 Figure 14. Write Word Protocol with PEC 42 Rev. B For more information www.analog.com LTM4680 OPERATION 1 7 S 1 1 8 1 1 1 7 1 SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A 8 1 1 DATA BYTE A P 4680 F15 Figure 15. Read Byte Protocol 1 S 7 1 1 8 1 1 7 1 8 1 DATA BYTE A 1 SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A PEC 1 1 A P 4680 F16 Figure 16. Read Byte Protocol with PEC 1 S 7 1 1 8 1 1 SLAVE ADDRESS Wr A COMMAND CODE A 7 1 1 Sr SLAVE ADDRESS Rd A 8 1 DATA BYTE LOW A 1 1 DATA BYTE HIGH A 8 P 4680 F17 Figure 17. Read Word Protocol 1 S 7 1 1 8 1 1 7 1 1 SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A 8 1 DATA BYTE LOW A 8 1 DATA BYTE HIGH A 8 1 1 PEC A P 4680 F18 Figure 18. Read Word Protocol with PEC 1 S 7 1 1 8 1 1 7 1 1 SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A 8 1 BYTE COUNT = N A 8 1 8 1 … 8 1 DATA BYTE 1 A DATA BYTE 2 A … DATA BYTE N A … 1 P 4680 F19 Figure 19. Block Read Protocol 1 S 7 1 1 8 1 1 7 1 1 SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A 8 1 BYTE COUNT = N A 8 1 8 1 … 8 1 8 1 1 DATA BYTE 1 A DATA BYTE 2 A … DATA BYTE N A PEC A P … 4680 F20 Figure 20. Block Read Protocol with PEC Rev. B For more information www.analog.com 43 LTM4680 OPERATION 1 S 7 1 1 8 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A BYTE COUNT = M A 8 1 DATA BYTE 2 1 7 1 8 A … 1 Sr SLAVE ADDRESS Rd A 8 1 DATA BYTE 1 A … 1 A … DATA BYTE M 8 1 BYTE COUNT = N A 8 1 1 DATA BYTE 1 A … 8 1 … 8 1 1 DATA BYTE 2 A … DATA BYTE N A P 4680 F21 Figure 21. Block Write – Block Read Process Call 1 S 7 1 1 8 1 8 1 SLAVE ADDRESS Wr A COMMAND CODE A BYTE COUNT = M A 8 1 DATA BYTE 2 1 7 1 8 A … 1 Sr SLAVE ADDRESS Rd A 8 1 DATA BYTE 1 A … 1 DATA BYTE M 8 A … 1 BYTE COUNT = N A 8 1 1 DATA BYTE 1 A … 8 1 … 8 1 8 1 1 DATA BYTE 2 A … DATA BYTE N A PEC A P 4680 F22 Figure 22. Block Write – Block Read Process Call with PEC 1 7 1 1 8 1 1 S ALERT RESPONSE Rd A DEVICE ADDRESS A ADDRESS P 4680 F23 Figure 23. Alert Response Address Protocol 1 7 1 1 8 1 S ALERT RESPONSE Rd A DEVICE ADDRESS A ADDRESS 8 1 1 PEC A P 4680 F24 Figure 24. Alert Response Address Protocol with PEC 44 Rev. B For more information www.analog.com LTM4680 PMBus COMMAND SUMMARY PMBus COMMANDS Table 7 lists supported PMBus commands and manufacturer specific commands. A complete description of these commands can be found in the “PMBus Power System Mgt Protocol Specification – Part II – Revision 1.2”. Users are encouraged to reference this specification. Exceptions or manufacturer specific implementations are listed in Table 7. Floating point values listed in the “DEFAULT VALUE” column are either Linear 16-bit Signed (PMBus Section 8.3.1) or Linear_5s_11s (PMBus Section 7.1) format, whichever is appropriate for the command. All commands from 0xD0 through 0xFF not listed in Table 7 are implicitly reserved by the manufacturer. Users should avoid blind writes within this range of commands to avoid undesired operation of the part. All commands from 0x00 through 0xCF not listed in Table 7 are implicitly not supported by the manufacturer. Attempting to access non-supported or reserved commands may result in a CML command fault event. All output voltage settings and measurements are based on the VOUT_MODE setting of 0x14. This translates to an exponent of 2–12. If PMBus commands are received faster than they are being processed, the part may become too busy to handle new commands. In these circumstances the part follows the protocols defined in the PMBus Specification v1.2, Part II, Section 10.8.7, to communicate that it is busy. The part includes handshaking features to eliminate busy errors and simplify error handling software while ensuring robust communication and system behavior. Please refer to the subsection titled PMBus Communication and Command Processing in the Applications Information section for further details. Table 7. PMBus Commands Summary (Note: The Data Format Abbreviations Are Detailed in Table 8) COMMAND NAME CMD CODE DESCRIPTION PAGE 0x00 Provides integration with multi-page PMBus devices. R/W Byte N Reg OPERATION 0x01 Operating mode control. On/off, margin high and margin low. R/W Byte Y Reg ON_OFF_CONFIG 0x02 RUN pin and PMBus bus on/off command configuration. R/W Byte Y Reg CLEAR_FAULTS 0x03 Clear any fault bits that have been set. Send Byte N PAGE_PLUS_WRITE 0x05 Write a command directly to a specified page. W Block N 77 PAGE_PLUS_READ 0x06 Read a command directly from a specified page. Block R/W N 77 WRITE_PROTECT 0x10 Level of protection provided by the device against accidental changes. R/W Byte N STORE_USER_ALL 0x15 Store user operating memory to EEPROM. Send Byte RESTORE_USER_ALL 0x16 Restore user operating memory from EEPROM. Send Byte CAPABILITY 0x19 Summary of PMBus optional communication protocols supported by this device. R Byte N Reg SMBALERT_MASK 0x1B Mask ALERT activity Block R/W Y Reg VOUT_MODE 0x20 Output voltage format and exponent (2–12). VOUT_COMMAND 0x21 VOUT_MAX 0x24 TYPE DATA PAGED FORMAT UNITS NVM Reg DEFAULT VALUE PAGE 0x00 77 Y 0x80 81 Y 0x1E 81 NA 106 Y 0x00 78 N NA 117 N NA 117 0xB0 105 See CMD 106 2–12 87 Y R Byte Y Reg Nominal output voltage set point. R/W Word Y L16 V Y 1.0 0x1000 88 Upper limit on the commanded output voltage including VOUT_MARGIN_HI. R/W Word Y L16 V Y 3.6 0x399A 87 0x14 Rev. B For more information www.analog.com 45 LTM4680 PMBus COMMAND SUMMARY COMMAND NAME CMD CODE DESCRIPTION VOUT_MARGIN_HIGH 0x25 Margin high output voltage set point. Must be greater than VOUT_COMMAND. R/W Word Y L16 V Y 1.05 0x10CD 88 VOUT_MARGIN_LOW 0x26 Margin low output voltage set point. Must be less than VOUT_COMMAND. R/W Word Y L16 V Y 0.95 0x0F33 88 VOUT_TRANSITION_ RATE 0X27 Rate the output changes when VOUT commanded to a new value. R/W Word Y L11 V/ms Y 0.001 0x8042 94 FREQUENCY_SWITCH 0x33 Switching frequency of the controller. R/W Word N L11 kHz Y 350kHz 0xFABC 85 VIN_ON 0x35 Input voltage at which the unit should start R/W Word power conversion. N L11 V Y 4.75 0xD130 86 VIN_OFF 0x36 Input voltage at which the unit should stop power conversion. R/W Word N L11 V Y 4.5 0xD120 86 VOUT_OV_FAULT_LIMIT 0x40 Output overvoltage fault limit. R/W Word Y L16 V Y 1.1 0x119A 87 VOUT_OV_FAULT_ RESPONSE 0x41 Action to be taken by the device when an output overvoltage fault is detected. R/W Byte Y Reg Y 0xB8 96 VOUT_OV_WARN_LIMIT 0x42 Output overvoltage warning limit. R/W Word Y L16 V Y 1.075 0x1133 87 VOUT_UV_WARN_LIMIT 0x43 Output undervoltage warning limit. R/W Word Y L16 V Y 0.925 0x0ECD 88 VOUT_UV_FAULT_LIMIT 0x44 Output undervoltage fault limit. R/W Word Y L16 V Y 0.9 0x0E66 88 VOUT_UV_FAULT_ RESPONSE 0x45 Action to be taken by the device when an output undervoltage fault is detected. R/W Byte Y Reg Y 0xB8 97 IOUT_OC_FAULT_LIMIT 0x46 Output overcurrent fault limit. R/W Word Y L11 Y 40.00 0xE280 90 IOUT_OC_FAULT_ RESPONSE 0x47 Action to be taken by the device when an output overcurrent fault is detected. R/W Byte Y Reg Y 0x00 99 IOUT_OC_WARN_LIMIT 0x4A Output overcurrent warning limit. R/W Word Y L11 A Y 35.0 0xE230 91 OT_FAULT_LIMIT 0x4F External overtemperature fault limit. R/W Word Y L11 C Y 128.0 0xF200 92 OT_FAULT_RESPONSE 0x50 Action to be taken by the device when an external overtemperature fault is detected, R/W Byte Y Reg Y 0xB8 101 OT_WARN_LIMIT 0x51 External overtemperature warning limit. R/W Word Y L11 C Y 125.0 0xEBE8 92 UT_FAULT_LIMIT 0x53 External undertemperature fault limit. R/W Word Y L11 C Y –45.0 0xE530 93 UT_FAULT_RESPONSE 0x54 Action to be taken by the device when an external undertemperature fault is detected. R/W Byte Y Reg Y 0xB8 101 VIN_OV_FAULT_LIMIT 0x55 Input supply overvoltage fault limit. R/W Word N L11 Y 15.5 0xD3E0 85 VIN_OV_FAULT_ RESPONSE 0x56 Action to be taken by the device when an input overvoltage fault is detected. R/W Byte Y Reg Y 0x80 96 VIN_UV_WARN_LIMIT 0x58 Input supply undervoltage warning limit. R/W Word N L11 V Y 4.65 0xD12A 86 IIN_OC_WARN_LIMIT 0x5D Input supply overcurrent warning limit. R/W Word N L11 A Y 20.0 0xDA80 91 46 TYPE DATA PAGED FORMAT UNITS NVM A V DEFAULT VALUE PAGE Rev. B For more information www.analog.com LTM4680 PMBus COMMAND SUMMARY COMMAND NAME CMD CODE DESCRIPTION TON_DELAY 0x60 Time from RUN and/or Operation on to output rail turn-on. R/W Word Y L11 ms Y 0.0 0x8000 93 TON_RISE 0x61 Time from when the output starts to rise until the output voltage reaches the VOUT commanded value. R/W Word Y L11 ms Y 3.0 0xC300 93 TON_MAX_FAULT_LIMIT 0x62 Maximum time from the start of TON_RISE for VOUT to cross the VOUT_UV_FAULT_LIMIT. R/W Word Y L11 ms Y 5.0 0xCA80 94 TON_MAX_FAULT_ RESPONSE 0x63 Action to be taken by the device when a TON_ MAX_FAULT event is detected. R/W Byte Y Reg Y 0xB8 99 TOFF_DELAY 0x64 Time from RUN and/or Operation off to the R/W Word start of TOFF_FALL ramp. Y L11 ms Y 0.0 0x8000 94 TOFF_FALL 0x65 Time from when the output starts to fall until the output reaches zero volts. R/W Word Y L11 ms Y 3.0 0xC300 94 TOFF_MAX_WARN_ LIMIT 0x66 Maximum allowed time, after TOFF_FALL completed, for the unit to decay below 12.5%. R/W Word Y L11 ms Y 0 0x8000 95 STATUS_BYTE 0x78 One byte summary of the unit’s fault condition. R/W Byte Y Reg NA 107 STATUS_WORD 0x79 Two byte summary of the unit’s fault condition. R/W Word Y Reg NA 108 STATUS_VOUT 0x7A Output voltage fault and warning status. R/W Byte Y Reg NA 109 STATUS_IOUT 0x7B Output current fault and warning status. R/W Byte Y Reg NA 110 STATUS_INPUT 0x7C Input supply fault and warning status. R/W Byte N Reg NA 110 STATUS_TEMPERATURE 0x7D External temperature fault and warning status for READ_TEMERATURE_1. R/W Byte Y Reg NA 110 STATUS_CML 0x7E Communication and memory fault and warning status. R/W Byte N Reg NA 111 STATUS_MFR_SPECIFIC 0x80 Manufacturer specific fault and state information. R/W Byte Y Reg NA 111 READ_VIN 0x88 Measured input supply voltage. R Word N L11 V NA 113 READ_IIN 0x89 Measured input supply current. R Word N L11 A NA 114 READ_VOUT 0x8B Measured output voltage. R Word Y L16 V NA 113 READ_IOUT 0x8C Measured output current. R Word Y L11 A NA 114 READ_TEMPERATURE_1 0x8D External temperature sensor temperature. This is the value used for all temperature related processing, including IOUT_CAL_GAIN. R Word Y L11 C NA 114 READ_TEMPERATURE_2 0x8E Internal die junction temperature. Does not affect any other commands. R Word N L11 C NA 114 READ_FREQUENCY 0x95 Measured PWM switching frequency. R Word Y L11 Hz NA 114 READ_POUT 0x96 Measured output power R Word Y L11 W N/A 114 READ_PIN 0x97 Calculated input power R Word Y L11 W N/A 114 PMBus_REVISION 0x98 PMBus revision supported by this device. Current revision is 1.2. R Byte N Reg 0x22 105 MFR_ID 0x99 The manufacturer ID of the LTM4680 in ASCII. R String N ASC ADI 105 MFR_MODEL 0x9A Manufacturer part number in ASCII. R String N ASC LTM4680 105 TYPE DATA PAGED FORMAT UNITS NVM DEFAULT VALUE PAGE Rev. B For more information www.analog.com 47 LTM4680 PMBus COMMAND SUMMARY COMMAND NAME CMD CODE DESCRIPTION MFR_VOUT_MAX 0xA5 Maximum allowed output voltage including VOUT_OV_FAULT_LIMIT. R Word Y L16 MFR_PIN_ACCURACY 0xAC Returns the accuracy of the READ_PIN command R Byte N % USER_DATA_00 0xB0 OEM RESERVED. Typically used for part serialization. R/W Word N Reg USER_DATA_01 0xB1 Manufacturer reserved for LTpowerPlay. R/W Word Y USER_DATA_02 0xB2 OEM RESERVED. Typically used for part serialization R/W Word USER_DATA_03 0xB3 An NVM word available for the user. USER_DATA_04 0xB4 An NVM word available for the user. MFR_EE_UNLOCK 0xBD Contact factory. 122 MFR_EE_ERASE 0xBE Contact factory. 122 MFR_EE_DATA 0xBF Contact factory. 122 MFR_CHAN_CONFIG 0xD0 Configuration bits that are channel specific. MFR_CONFIG_ALL 0xD1 MFR_FAULT_ PROPAGATE 0xD2 MFR_PWM_COMP MFR_PWM_MODE TYPE DATA PAGED FORMAT UNITS NVM V DEFAULT VALUE PAGE 3.6 0x399A 89 5.0% 115 Y NA 105 Reg Y NA 105 N Reg Y NA 105 R/W Word Y Reg Y 0x0000 105 R/W Word N Reg Y 0x0000 105 R/W Byte Y Reg Y General configuration bits. R/W Byte N Reg Y 0x21 80 Configuration that determines which faults are propagated to the FAULT pin. R/W Word Y Reg Y 0x6993 102 0xD3 PWM loop compensation configuration R/W Byte Y Reg Y 0x28 83 0xD4 Configuration for the PWM engine. R/W Byte Y Reg Y 0x47 82 MFR_FAULT_RESPONSE 0xD5 Action to be taken by the device when the FAULT pin is externally asserted low. R/W Byte Y Reg Y 0xC0 104 MFR_OT_FAULT_ RESPONSE 0xD6 Action to be taken by the device when an internal overtemperature fault is detected. R Byte N Reg 0xC0 100 MFR_IOUT_PEAK 0xD7 Report the maximum measured value of READ_ IOUT since last MFR_CLEAR_PEAKS. R Word Y L11 NA 115 MFR_ADC_CONTROL 0xD8 ADC telemetry parameter selected for repeated fast ADC read back R/W Byte N Reg 0x00 116 MFR_RETRY_DELAY 0xDB Retry interval during FAULT retry mode. R/W Word Y L11 ms Y 250.0 0xF3E8 95 MFR_RESTART_DELAY 0xDC Minimum time the RUN pin is held low by the LTM4680. R/W Word Y L11 ms Y 150.0 0xF258 95 MFR_VOUT_PEAK 0xDD Maximum measured value of READ_VOUT since last MFR_CLEAR_PEAKS. R Word Y L16 V NA 115 MFR_VIN_PEAK 0xDE Maximum measured value of READ_VIN since last MFR_CLEAR_PEAKS. R Word N L11 V NA 115 MFR_TEMPERATURE_1_ PEAK 0xDF Maximum measured value of external Temperature (READ_TEMPERATURE_1) since last MFR_CLEAR_PEAKS. R Word Y L11 C NA 115 MFR_READ_IIN_PEAK 0xE1 Maximum measured value of READ_IIN command since last MFR_CLEAR_PEAKS R Word N L11 A NA 115 MFR_CLEAR_PEAKS 0xE3 Clears all peak values. Send Byte N NA 107 MFR_READ_ICHIP 0xE4 Measured supply current of the SVIN pin R Word N L11 NA 115 MFR_PADS 0xE5 Digital status of the I/O pads. R Word N Reg NA 112 48 A A 0x1D 79 Rev. B For more information www.analog.com LTM4680 PMBus COMMAND SUMMARY COMMAND NAME CMD CODE DESCRIPTION TYPE MFR_ADDRESS 0xE6 Sets the 7-bit I2C address byte. MFR_SPECIAL_ID 0xE7 Manufacturer code representing the LTM4680 and revision MFR_IIN_CAL_GAIN 0xE8 MFR_FAULT_LOG_ STORE 0xEA MFR_INFO 0x DATA PAGED FORMAT UNITS NVM R/W Byte N Reg R Word N Reg The resistance value of the input current sense element in mΩ. R/W Word N L11 Command a transfer of the fault log from RAM to EEPROM. Send Byte N R Word Y Send Byte N Y mΩ Y DEFAULT VALUE PAGE 0x4F 79 0x414X 105 1.0 0xBA00 91 NA 118 Contact factory. 122 MFR_IOUT_CAL_GAIN 0xDA SET AT FACTORY L11 MFR_FAULT_LOG_ CLEAR 0xEC Initialize the EEPROM block reserved for fault logging. MFR_FAULT_LOG 0xEE Fault log data bytes. R Block N Reg MFR_COMMON 0xEF Manufacturer status bits that are common across multiple ADI chips. R Byte N Reg MFR_COMPARE_USER_ ALL 0xF0 Compares current command contents with NVM. Send Byte N MFR_TEMPERATURE_2_ PEAK 0xF4 Peak internal die temperature since last MFR_ CLEAR_PEAKS. R Word N L11 MFR_PWM_CONFIG 0xF5 Set numerous parameters for the DC/DC controller including phasing. R/W Byte N Reg MFR_IOUT_CAL_GAIN_ TC 0xF6 Temperature coefficient of the current sensing element. R/W Word Y CF MFR_ICHIP_CAL_GAIN 0xF7 The resistance value of the VIN pin filter element in mΩ. R/W Word N L11 MFR_TEMP_1_GAIN 0xF8 Sets the slope of the external temperature sensor. R/W Word Y CF MFR_TEMP_1_OFFSET 0xF9 Sets the offset of the external temperature sensor with respect to –273.1°C R/W Word Y L11 MFR_RAIL_ADDRESS 0xFA Common address for PolyPhase outputs to adjust common parameters. R/W Byte Y Reg MFR_REAL_TIME 0xFB 48-bit share-clock counter value. R Block N CF MFR_RESET 0xFD Commanded reset without requiring a power down. Send Byte N mΩ 89 NA 122 NA 118 NA 112 NA 117 NA 116 Y 0x10 84 ppm/ ˚C Y 3800 0x0ED8 89 mΩ Y 1000 0x03E8 86 Y 0.995 0x3FAE 92 Y 0.0 0x8000 92 Y 0x80 79 NA 66 NA 81 Y C C Note 1: Commands indicated with Y in the NVM column indicate that these commands are stored and restored using the STORE_USER_ALL and RESTORE_USER_ALL commands, respectively. Note 2: Commands with a default value of NA indicate “not applicable”. Commands with a default value of FS indicate “factory set on a per part basis”. Note 3: The LTM4680 contains additional commands not listed in Table 7. Reading these commands is harmless to the operation of the IC; however, the contents and meaning of these commands can change without notice. Note 4: Some of the unpublished commands are read-only and will generate a CML bit 6 fault if written. Note 5: Writing to commands not published in Table 7 is not permitted. Note 6: The user should not assume compatibility of commands between different parts based upon command names. Always refer to the manufacturer’s data sheet for each part for a complete definition of a command’s function. ADI strives to keep command functionality compatible between all ADI devices. Differences may occur to address specific product requirements. Rev. B For more information www.analog.com 49 LTM4680 PMBus COMMAND SUMMARY Table 8. Data Format Abbreviations L11 Linear_5s_11s PMBus data field b[15:0] Value = Y • 2N where N = b[15:11] is a 5-bit two’s complement integer and Y = b[10:0] is an 11-bit two’s complement integer Example: For b[15:0] = 0x9807 = ‘b10011_000_0000_0111 Value = 7 • 2–13 = 854 • 10–6 From “PMBus Spec Part II: Paragraph 7.1” L16 Linear_16u PMBus data field b[15:0] Value = Y • 2N where Y = b[15:0] is an unsigned integer and N = VOUT_MODE_PARAMETER is a 5-bit two’s complement exponent that is hardwired to –12 decimal Example: For b[15:0] = 0x9800 = ‘b1001_1000_0000_0000 Value = 19456 • 2–12 = 4.75 From “PMBus Spec Part II: Paragraph 8.2” Reg Register PMBus data field b[15:0] or b[7:0]. Bit field meaning is defined in detailed PMBus Command Description. L16 Integer Word PMBus data field b[15:0] Value = Y where Y = b[15:0] is a 16-bit unsigned integer Example: For b[15:0] = 0x9807 = ‘b1001_1000_0000_0111 Value = 38919 (decimal) CF Custom Format Value is defined in detailed PMBus Command Description. This is often an unsigned or two’s complement integer scaled by an MFR specific constant. ASC ASCII Format A variable length string of text characters conforming to ISO/IEC 8859-1 standard. 50 Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION VIN TO VOUT STEP-DOWN RATIOS OUTPUT CAPACITORS There are restrictions in the maximum VIN and VOUT stepdown ratio that can be achieved for a given input voltage. Each output of the LTM4680 is capable of 95% duty cycle at 500kHz, but the VIN to VOUT minimum dropout is still a function of its load current and will limit output current capability related to high duty cycle on the topside switch. The LTM4680 is designed for low output voltage ripple noise and good transient response. The bulk output capacitors defined as COUT are chosen with low enough effective series resistance (ESR) to meet the output voltage ripple and transient requirements. COUT can be a low ESR tantalum capacitor, a low ESR polymer capacitor or ceramic capacitor. The typical output capacitance range for each output is from 400µF to 1000µF. Additional output filtering may be required by the system designer, if further reduction of output ripple or dynamic transient spikes is required. Table 13 shows a matrix of different output voltages and output capacitors to minimize the voltage droop and overshoot during a 15A to 30A step, 15A/µs transient each channel. Table 13 optimizes total equivalent ESR and total bulk capacitance to optimize the transient performance. Stability criteria are considered in the Table 13 matrix, and the LTPowerCAD Design Tool will be provided for stability analysis. Multiphase operation reduces effective output ripple as a function of the number of phases. Application Note 77 discusses this noise reduction versus output ripple current cancellation, but the output capacitance should be considered carefully as a function of stability and transient response. The LTPowerCAD Design Tool can calculate the output ripple reduction as the number of implemented phases increases by N times. A small value 10Ω resistor can be placed in series from VOUTn to the VOSNS0+ pin to allow for a bode plot analyzer to inject a signal into the control loop and validate the regulator stability. The LTM4680’s stability compensation can be adjusted using two external capacitors, and the MFR_PWM_COMP commands. Minimum on-time tON(MIN) is another consideration in operating at a specified duty cycle while operating at a certain frequency due to the fact that tON(MIN) < D/fSW, where D is duty cycle and fSW is the switching frequency. tON(MIN) is specified in the electrical parameters as 60ns. See Note 6 in the Electrical Characteristics section for output current guideline. INPUT CAPACITORS The LTM4680 module should be connected to a low AC impedance DC source. For the regulator input, four 22µF input ceramic capacitors are used to handle the RMS ripple current. A 47µF to 150µF surface mount aluminum electrolytic bulk capacitor can be used for more input bulk capacitance. This bulk input capacitor is only needed if the input source impedance is compromised by long inductive leads, traces or not enough source capacitance. If low impedance power planes are used, then this bulk capacitor is not needed. For a buck converter, the switching duty-cycle can be estimated as: Dn = VOUTn VINn Without considering the inductor current ripple, for each output, the RMS current of the input capacitor can be estimated as: ICINn (RMS) = IOUTn (MAX) η% • Dn • (1− Dn ) In the above equation, η% is the estimated efficiency of the power module. The bulk capacitor can be a switcher-rated electrolytic aluminum capacitor, or a polymer capacitor. LIGHT LOAD CURRENT OPERATION The LTM4680 has two modes of operation including high efficiency, discontinuous conduction mode or forced continuous conduction mode. The mode of operation is configured by bit 0 of the MFR_PWM_MODEn command (discontinuous conduction is always the start-up mode, forced continuous is the default running mode). If a channel is enabled for discontinuous mode operation, the inductor current is not allowed to reverse. The Rev. B For more information www.analog.com 51 LTM4680 APPLICATIONS INFORMATION reverse current comparator, IREV, turns off the bottom MOSFET (MBn) just before the inductor current reaches zero, preventing it from reversing and going negative. Thus, the controller can operate in discontinuous (pulseskipping) operation. In forced continuous operation, the inductor current is allowed to reverse at light loads or under large transient conditions. The peak inductor current is determined solely by the voltage on the COMPna pin. In this mode, the efficiency at light loads is lower than in discontinuous mode operation. However, continuous mode exhibits lower output ripple and less interference with audio circuitry. Forced continuous conduction mode may result in reverse inductor current, which can cause the input supply to boost. The VIN_OV_FAULT_LIMIT can detect this (if SVIN is connected to VIN0 and/or VIN1) and turn off the offending channel. However, this fault is based on an ADC read and can nominally take up to 100ms to detect. If there is a concern about the input supply boosting, keep the part in discontinuous conduction operation. SWITCHING FREQUENCY AND PHASE The switching frequency of the LTM4680’s channels is established by its analog phase-locked-loop (PLL) locking on to the clock present at the module’s SYNC pin. The clock waveform on the SYNC pin can be generated by the LTM4680’s internal circuitry when an external pull-up resistor to 3.3V (e.g., VDD33) is provided, in combination with the LTM4680 control IC’s FREQUENCY_SWITCH command being set to one of the following supported values: 250kHz, 350kHz, 425kHz, 500kHz, 575kHz, 650kHz, 750kHz, 1000kHz. In this configuration, the module is called a “sync master”: (using the factory-default setting of MFR_ CONFIG_ALL[4] = 0b), SYNC becomes a bidirectional open-drain pin, and the LTM4680 pulls SYNC logic low for nominally 500ns at a time, at the prescribed clock rate. The SYNC signal can be bused to other LTM4680 modules (configured as “sync slaves”), for purposes of synchronizing switching frequencies of multiple modules within a system—but only one LTM4680 should be configured as a “sync master”; the other LTM4680(s) should be configured as “sync slaves”. The most straightforward way is to set its FREQUENCY_ SWITCH command to 0x0000 and MFR_CONFIG_ 52 ALL[4] = 1b. This can be easily implemented with resistor pin-strap settings on the FSWPH_CFG pin (see Table 3). Using MFR_CONFIG_ALL[4] = 1b, the LTM4680s SYNC pin becomes a high impedance input, only—i.e., it does not drive SYNC low. The module synchronizes its frequency to that of the clock applied to its SYNC pin. The only shortcoming of this approach is: in the absence of an externally applied clock, the switching frequency of the module will default to the low end of its frequencysynchronization capture range (~225kHz). If fault-tolerance to the loss of an externally applied SYNC clock is desired, the FREQUENCY_SWITCH command of a “sync slave” can be left at the nominal target switching frequency of the application, and not 0x0000 However, it is then still necessary to configure MFR_CONFIG_ ALL[4] = 1b. With this combination of configurations, the LTM4680’s SYNC pin becomes a high impedance input and the module synchronizes its frequency to that of the externally applied clock, provided that the frequency of the externally applied clock exceeds ~½. of the target frequency (FREQUENCY_SWITCH). If the SYNC clock is absent, the module responds by operating at its target frequency, indefinitely. If and when the SYNC clock is restored, the module automatically phase-locks to the SYNC clock as normal. The only shortcoming of this approach is: the EEPROM must be configured per above guidance; resistor pin-strapping options on the FSWPH_CFG pin alone cannot provide fault-tolerance to the absence of the SYNC clock. The FREQUENCY_SWITCH register can be altered via I2C commands, but only when switching action is disengaged, i.e., the module’s outputs are turned off. The FREQUENCY_ SWITCH command takes on the value stored in NVM at SVIN power-up, but is overridden according to a resistor pin-strap applied between the FSWPH_CFG pin and SGND only if the module is configured to respect resistor pin-strap settings (MFR_CONFIG_ALL[6] = 0b). Table 3 highlights available resistor pin-strap and corresponding FREQUENCY_SWITCH settings. The relative phasing of all active channels in a PolyPhase rail should be optimally phased. The relative phasing of each rail is 360°/n, where n is the number of phases in the rail. MFR_PWM_CONFIG[2:0] configures channel relative Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION phasing with respect to the SYNC pin. Phase relationship values are indicated with 0° corresponding to the falling edge of SYNC being coincident with the turn-on of the top MOSFETs. The MFR_PWM_CONFIG command can be altered via I2C commands, but only when switching action is disengaged, i.e., the module’s outputs are turned off. The MFR_PWM_CONFIG command takes on the value stored in NVM at SVIN power-up, but is overridden according to a resistor pin-strap applied between the FSWPH_CFG pin and SGND only if the module is configured to respect resistor pin-strap settings (MFR_CONFIG_ALL[6] = 0b). Table 3 highlights available resistor pin-strap and corresponding MFR_PWM_CONFIG[2:0] settings. Some combinations of FREQUENCY_SWITCH and MFR_PWM_CONFIG[2:0] are not available by resistor pin-strapping the FSWPH_CFG pin. All combinations of supported values for FREQUENCY_SWITCH and MFR_ PWM_CONFIG[2:0] can be configured by NVM programming—or, I2C transactions, provided switching action is disengaged, i.e., the module’s outputs are turned off. Care must be taken to minimize capacitance on SYNC to assure that the pull-up resistor versus the capacitor load has a low enough time constant for the application to form a “clean” clock. (See “Open-Drain Pins”, later in this section.) When an LTM4680 is configured as a sync slave, it is permissible for external circuitry to drive the SYNC pin from a current-limited source (less than 10mA), rather than using a pull-up resistor. Any external circuitry must not drive high with arbitrarily low impedance at SVIN powerup, because the SYNC output can be low impedance until NVM contents have been downloaded to RAM. Recommended LTM4680 switching frequencies of operation for many common VIN-to-VOUT applications are indicated below. When the two channels of an LTM4680 are stepping input voltage(s) down to output voltages whose recommended switching frequencies below are significantly different, operation at the higher of the two recommended switching frequencies is preferable, but minimum on-time must be considered. (See Minimum On-Time Considerations section.) Table 9. Recommended Switching Frequency for Various VINto-VOUT Step-Down Scenarios 5VIN 0.9VOUT 1.0VOUT 1.2VOUT 1.5VOUT 1.8VOUT 8VIN 12VIN 250kHz to 350kHz 350kHz to 500kHz 500kHz to 575kHz 2.5VOUT 575kHz to 750kHz 3.3VOUT 650kHz to 1000kHz OUTPUT CURRENT LIMIT PROGRAMMING The cycle-by-cycle current limit (= VISENSE/DCR) is proportional to COMPn, which can be programmed from 1.45V to 2.2V using the PMBus command IOUT_OC_FAULT_ LIMIT. The LTM4680 uses only the sub-milliohm sensing to detect current levels. See page 90. The LTM4680 has two ranges of current limit programming. The value of MFR_PWM_MODE[2] is reserved and the MFR_PWM_ MODE[7], and IOUT_OC_FAULT_LIMIT are used to set the current limit level, see the section of the PMBus commands, the device can regulate output voltage with the peak current under the value of IOUT_OC_FAULT_LIMIT in normal operation. In case of output current exceeding that current limit, a OC fault will be issued. Each of the IOUT_OC_FAULT_LIMIT ranges will affect the loop gain, and subsequently affect the loop stability, so setting the range of current limiting is a part of loop design. The LTPowerCAD Design Tool can be used to look at the loop stability changes if current limit is adjusted. The LTM4680 will automatically update the current limit as the inductor temperature changes. Keep in mind this operation is on a cycle-by-cycle basis and is only a function of the peak inductor current. The average inductor current is monitored by the ADC converter and can provide a warning if too much average output current is detected. The overcurrent fault is detected when the COMPn voltage hits the maximum value. The digital processor within the LTM4680 provides the ability to either ignore the fault, shut down and latch off or shut down and retry indefinitely (hiccup). Refer to the overcurrent portion of the Operation section for more detail. The Read_POUT can be used to readback calculated output power. Rev. B For more information www.analog.com 53 LTM4680 APPLICATIONS INFORMATION MINIMUM ON-TIME CONSIDERATIONS Minimum on-time, tON(MIN), is the smallest time duration that the LTM4680 is capable of turning on the top MOSFET. It is determined by internal timing delays and the gate charge required to turn on the top MOSFET. Low duty cycle applications may approach this minimum on-time limit and care should be taken to ensure that: tON(MIN) < VOUTn VINn • fOSC If the duty cycle falls below what can be accommodated by the minimum on-time, the controller will begin to skip cycles. The output voltage will continue to be regulated, but the ripple voltage and current will increase. The minimum on-time for the LTM4680 is 60ns. VARIABLE DELAY TIME, SOFT-START AND OUTPUT VOLTAGE RAMPING The LTM4680 must enter its run state prior to soft-start. The RUNn pins are released after the part initializes and SVIN is greater than the VIN_ON threshold. If multiple LTM4680s are used in an application, they should be configured to share the same RUNn pins. They all hold their respective RUNn pins low until all devices initialize and SVIN exceeds the VIN_ON threshold for all devices. The SHARE_CLK pin assures all the devices connected to the signal use the same time base. After the RUNn pin releases, the controller waits for the user-specified turn-on delay (TON_DELAYn) prior to initiating an output voltage ramp. Multiple LTM4680s and other ADI parts can be configured to start with variable delay times. To work correctly, all devices use the same timing clock (SHARE_CLK) and all devices must share the RUNn pin. This allows the relative delay of all parts to be synchronized. The actual variation in the delay will be dependent on the highest clock rate of the devices connected to the SHARE_CLK pin (all Analog Devices ICs are configured to allow the fastest SHARE_CLK signal to control the timing of all devices). The SHARE_CLK signal can be ±10% 54 in frequency, thus the actual time delays will have some variance. Soft-start is performed by actively regulating the load voltage while digitally ramping the target voltage from 0V to the commanded voltage set point. The rise time of the voltage ramp can be programmed using the TON_RISEn command to minimize inrush currents associated with the start-up voltage ramp. The soft-start feature is disabled by setting TON_RISEn to any value less than 0.250ms. The LTM4680 performs the necessary math internally to assure the voltage ramp is controlled to the desired slope. However, the voltage slope can not be any faster than the VOUTn fundamental limits of the power stage. The number of tON(MIN) steps in the ramp is equal to TON_RISE/0.1ms. Therefore, the shorter the TON_RISEn time setting, the more discrete steps in the soft-start ramp appear. The LTM4680 PWM always operates in discontinuous mode during the TON_RISEn operation. In discontinuous mode, the bottom MOSFET (MBn) is turned off as soon as reverse current is detected in the inductor. This allows the regulator to start up into a pre-biased load. There is no analog tracking feature in the LTM4680; however, two outputs can be given the same TON_RISEn and TON_DELAYn times to achieve ratiometric rail tracking. Because the RUNn pins are released at the same time and both units use the same time base (SHARE_CLK), the outputs track very closely. If the circuit is in a PolyPhase configuration, all timing parameters must be the same. DIGITAL SERVO MODE For maximum accuracy in the regulated output voltage, enable the digital servo loop by asserting bit 6 of the MFR_PWM_MODE command. In digital servo mode, the LTM4680 will adjust the regulated output voltage based on the ADC voltage reading. Every 90ms the digital servo loop will step the LSB of the DAC (nominally 1.375mV or 0.6875mV depending on the voltage range bit) until the output is at the correct ADC reading. At power-up this mode engages after TON_MAX_FAULT_LIMIT unless the limit is set to 0 (infinite). If the TON_MAX_FAULT_LIMIT is set to 0 (infinite), the servo begins after TON_RISE is complete and VOUT has exceeded the VOUT_UV_FAULT_LIMIT. Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION This same point in time is when the output changes from discontinuous to the programmed mode as indicated in MFR_PWM_MODE bit 0. Refer to Figure 25 for details on the VOUT waveform under time-based sequencing. If the TON_MAX_FAULT_LIMIT is set to a value greater than 0 and the TON_MAX_FAULT_RESPONSE is set to ignore 0x00, the servo begins: 1. After the TON_RISE sequence is complete 2. After the TON_MAX_FAULT_LIMIT time is reached; and 3. After the VOUT_UV_FAULT_LIMIT has been exceed or the IOUT_OC_FAULT_LIMIT is no longer active. If the TON_MAX_FAULT_LIMIT is set to a value greater than 0 and the TON_MAX_FAULT_RESPONSE is not set to ignore 0x00, the servo begins: 1. After the TON_RISE sequence is complete 2. After the TON_MAX_FAULT_LIMIT time has expired and both VOUT_UV_FAULT and IOUT_OC_FAULT are not present. The maximum rise time is limited to 1.3 seconds. In a PolyPhase configuration it is recommended only one of the control loops have the digital servo mode enabled. This will assure the various loops do not work against each other due to slight differences in the reference circuits. SOFT OFF (SEQUENCED OFF) In addition to a controlled start-up, the LTM4680 also supports controlled turn-off. The TOFF_DELAY and TOFF_ FALL functions are shown in Figure 26. TOFF_FALL is processed when the RUN pin goes low or if the part is commanded off. If the part faults off or FAULTn is pulled low externally and the part is programmed to respond to this, the output will three-state rather than exhibiting a controlled ramp. The output will decay as a function of the load. The output voltage will operate as shown in Figure  26 as long as the part is in forced continuous mode and the TOFF_FALL time is sufficiently slow that the power stage can achieve the desired slope. The TOFF_FALL time can only be met if the power stage and controller can sink sufficient current to assure the output is at zero volts by the end of the fall time interval. If the TOFF_FALL time is set shorter than the time required to discharge the load capacitance, the output will not reach the desired zero volt state. At the end of TOFF_FALL, the controller will cease to sink current and VOUT will decay at the natural rate determined by the load impedance. If the controller is in discontinuous mode, the controller will not pull negative current and the output will be pulled low by the load, not the power stage. The maximum fall time is limited to 1.3 seconds. The shorter TOFF_FALL time is set, the larger the discrete steps in the TOFF_FALL ramp will appear. The number of steps in the ramp is equal to TOFF_FALL/0.1ms. DIGITAL SERVO MODE ENABLED FINAL OUTPUT VOLTAGE REACHED TON_MAX_FAULT_LIMIT DAC VOLTAGE ERROR (NOT TO SCALE) VOUT TON_DELAY TON_RISE TIME DELAY OF 200-400ms VOUT TOFF_DELAY TIME TOFF_FALL TIME 4680 F26 4680 F25 Figure 25. Timing Controlled VOUT Rise Figure 26. TOFF_DELAY and TOFF_FALL Rev. B For more information www.analog.com 55 LTM4680 APPLICATIONS INFORMATION UNDERVOLTAGE LOCKOUT The LTM4680 is initialized by an internal threshold-based UVLO where VIN must be approximately 4V and INTVCC, VDD33, and VDD25 must be within approximately 20% of their regulated values. In addition, VDD33 must be within approximately 7% of the targeted value before the RUN pin is released. After the part has initialized, an additional comparator monitors VIN. The VIN_ON threshold must be exceeded before the power sequencing can begin. When VIN drops below the VIN_OFF threshold, the SHARE_CLK pin will be pulled low and VIN must increase above the VIN_ON threshold before the controller will restart. The normal start-up sequence will be allowed after the VIN_ ON threshold is crossed. If FAULTn is held low when VIN is applied, ALERT will be asserted low even if the part is programmed to not assert ALERT when FAULTn is held low. If I2C communication occurs before the LTM4680 is out of reset and only a portion of the command is seen by the part, this can be interpreted as a CML fault. If a CML fault is detected, ALERT is asserted low. It is possible to program the contents of the NVM in the application if the VDD33 supply is externally driven directly to VDD33 or through EXTVCC. This will activate the digital portion of the LTM4680 without engaging the high voltage sections. PMBus communications are valid in this supply configuration. If VIN has not been applied to the LTM4680, bit 3 (NVM Not Initialized) in MFR_COMMON will be asserted low. If this condition is detected, the part will only respond to addresses 0x5A and 0x5B. To initialize the part issue the following set of commands: global address 0x5B command 0xBD data 0x2B followed by global address 0x5B command 0xBD and data 0xC4. The part will now respond to the correct address. Configure the part as desired then issue a STORE_USER_ALL. When VIN is applied a MFR_RESET command must be issued to allow the PWM to be enabled and valid ADC conversions to be read. can be pulled low by external sources indicating a fault in some other portion of the system. The fault response is configurable and allows the following options: Ignore n Shut Down Immediately—Latch Off n Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY n Refer to the PMBus section of the data sheet and the PMBus specification for more details. The OV response is automatic. If an OV condition is detected, TGn goes low and BGn is asserted. Fault logging is available on the LTM4680. The fault logging is configurable to automatically store data when a fault occurs that causes the unit to fault off. The header portion of the fault logging table contains peak values. It is possible to read these values at any time. This data will be useful while troubleshooting the fault. If the LTM4680 internal temperature is in excess of 85°C, writes into the NVM (other than fault logging) are not recommended. The data will still be held in RAM, unless the 3.3V supply UVLO threshold is reached. If the die temperature exceeds 130°C all NVM communication is disabled until the die temperature drops below 120°C. OPEN-DRAIN PINS The LTM4680 has the following open-drain pins: 3.3V Pins 1. FAULTn 2. SYNC 3. SHARE_CLK 4. PGOODn 5V Pins (5V pins operate correctly when pulled to 3.3V.) FAULT DETECTION AND HANDLING 1. RUNn The LTM4680 FAULT pins are configurable to indicate a variety of faults including OV, UV, OC, OT, timing faults, and peak over current faults. In addition, the FAULT pins 3. SCL 56 2. ALERT 4. SDA Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION All the above pins have on-chip pull-down transistors that can sink 3mA at 0.4V. The low threshold on the pins is 0.8V; thus, there is plenty of margin on the digital signals with 3mA of current. For 3.3V pins, 3mA of current is a 1.1k resistor. Unless there are transient speed issues associated with the RC time constant of the resistor pullup and parasitic capacitance to ground, a 10k resistor or larger is generally recommended. For high speed signals such as the SDA, SCL and SYNC, a lower value resistor may be required. The RC time constant should be set to 1/3 to 1/5 the required rise time to avoid timing issues. For a 100pF load and a 400kHz PMBus communication rate, the rise time must be less than 300ns. The resistor pull-up on the SDA and SCL pins with the time constant set to 1/3 the rise time is: RPULLUP = tRISE = 1k 3 •100pF The closest 1% resistor value is 1k. Be careful to minimize parasitic capacitance on the SDA and SCL pins to avoid communication problems. To estimate the loading capacitance, monitor the signal in question and measure how long it takes for the desired signal to reach approximately 63% of the output value. This is a one time constant. The SYNC pin has an on-chip pull-down transistor with the output held low for nominally 500ns. If the internal oscillator is set for 500kHz and the load is 100pF and a 3x time constant is required, the resistor calculation is as follows: RPULLUP = 2µs – 500ns = 5k 3 •100pF The closest 1% resistor is 4.99k. If timing errors are occurring or if the SYNC frequency is not as fast as desired, monitor the waveform and determine if the RC time constant is too long for the application. If possible reduce the parasitic capacitance. If not, reduce the pull-up resistor sufficiently to assure proper timing. The SHARE_CLK pull-up resistor has a similar equation with a period of 10µs and a pull-down time of 1µs. The RC time constant should be approximately 3µs or faster. PHASE-LOCKED LOOP AND FREQUENCY SYNCHRONIZATION The LTM4680 has a phase-locked loop (PLL) comprised of an internal voltage-controlled oscillator (VCO) and a phase detector. The PLL is locked to the falling edge of the SYNC pin. The phase relationship between the PWM controller and the falling edge of SYNC is controlled by the lower 3 bits of the MFR_PWM_ CONFIG command. For PolyPhase applications, it is recommended that all the phases be spaced evenly. Thus for a 2-phase system the signals should be 180° out of phase and a 4-phase system should be spaced 90°. The phase detector is an edge-sensitive digital type that provides a known phase shift between the external and internal oscillators. This type of phase detector does not exhibit false lock to harmonics of the external clock. The output of the phase detector is a pair of complementary current sources that charge or discharge the internal filter network. The PLL lock range is guaranteed between 200kHz and 1MHz. Nominal parts will have a range beyond this; however, operation to a wider frequency range is not guaranteed. The PLL has a lock detection circuit. If the PLL should lose lock during operation, bit 4 of the STATUS_MFR_ SPECIFIC command is asserted and the ALERT pin is pulled low. The fault can be cleared by writing a 1 to the bit. If the user does not wish to see the ALERT pin assert if a PLL_FAULT occurs, the SMBALERT_MASK command can be used to prevent the alert. If the SYNC signal is not clocking in the application, the nominal programmed frequency will control the PWM circuitry. However, if multiple parts share the SYNC pins and the signal is not clocking, the parts will not be synchronized and excess voltage ripple on the output may be present. Bit 10 of MFR_PADS will be asserted low if this condition exists. If the PWM signal appears to be running at too high a frequency, monitor the SYNC pin. Extra transitions on the falling edge will result in the PLL trying to lock on to noise versus the intended signal. Review routing of digital control signals and minimize crosstalk to the SYNC signal Rev. B For more information www.analog.com 57 LTM4680 APPLICATIONS INFORMATION to avoid this problem. Multiple LTM4680s are required to share one SYNC pin in PolyPhase configurations. For other configurations, connecting the SYNC pins to form a single SYNC signal is optional. If the SYNC pin is shared between LTM4680s, only one LTM4680 can be programmed with a frequency output. All the other LTM4680s should be programmed to disable the SYNC output. However their frequency should be programmed to the nominal desired value. INPUT CURRENT SENSE AMPLIFIER The LTM4680 input current sense amplifier can sense the supply current into the VIN0 and VIN1 power stages pins using an external sense resistor as shown in the Figure 2 Block Diagram. The RSENSE value can be programmed using the MFR_IIN_CAL_GAIN command. Kelvin sensing is recommended across the RSENSE resistor to eliminate errors. The MFR_PWM_CONFIG [6:5] sets the input current sense amplifier gain. See the MFR_PWM_CONFIG section. The IIN_OC_WARN_LIMIT command sets the value of the input current measured by the ADC, in amperes, that causes a warning indicating the input current is high. The READ_IIN value will be used to determine if this limit has been exceeded. The READ_IIN command returns the input current, in Amperes, as measured across the input current sense resistor. There is an IR voltage drop from the supply to the SVIN pin due to the current flowing into the SVIN pin. To compensate for this voltage drop, the MFR_RVIN will be automatically set to the 1Ω internal sense resistor in the Figure 2 Block Diagram. The LTM4680 will multiply the MFR_READ_ICHIP measurement value by this 1Ω resistor and add this voltage to the measured voltage at the SVIN pin. Therefore, READ_VIN = VSVIN_PIN + (MFR_ READ_ICHIP • 1Ω) The MFR_READ_ICHIP command is used to measure the internal controller current. Using the READ_PIN command allows for reading calculated input power. change. The error amplifier gain gm varies from 1.0mmho to 5.73mmho, and the compensation resistor RCOMPn varies from 0kΩ to 62kΩ inside the controller. Two compensation capacitors, COMPna and COMPnb, are required in the design and the typical ratio between COMPna and COMPnb is 10. Also see Figure  2 Block Diagram and Figure 27. By adjusting the gm and RCOMPn only, the LTM4680 can provide a flexible Type II compensation network to optimize the loop over a wide range of output capacitors. Adjusting the gm will change the gain of the compensation over the whole frequency range without moving the pole and zero location, as shown in Figure 28. Adjusting the RCOMP will change the pole and zero location, as shown in Figure 29. It is recommended that the user determines the appropriate value for the gm and RCOMPn using the LTPowerCAD tool. gm RCOMPn COMPna COMPnb CCOMPL CCOMPH + VREF – FB 4680 F27 Figure 27. Programmable Loop Compensation TYPE II COMPENSATION GAIN INCREASE gm PROGRAMMABLE LOOP COMPENSATION FREQUENCY The LTM4680 offers programmable loop compensation to optimize the transient response without any hardware 58 4680 F28 Figure 28. Error Amp gm Adjust Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION TYPE II COMPENSATION GAIN INCREASE RCOMPn FREQUENCY 4680 F29 Figure 29. RCOMP Adjust CHECKING TRANSIENT RESPONSE The regulator loop response can be checked by looking at the load current transient response. Switching regulators take several cycles to respond to a step in DC (resistive) load current. When a load step occurs, VOUT shifts by an amount equal to ∆ILOAD(ESR), where ESR is the effective series resistance of COUT. ∆ILOAD also begins to charge or discharge COUT generating the feedback error signal that forces the regulator to adapt to the current change and return VOUT to its steady-state value. During this recovery time VOUT can be monitored for excessive overshoot or ringing, which would indicate a stability problem. The availability of the COMP pin not only allows optimization of control loop behavior but also provides a DC-coupled and AC-filtered closed-loop response test point. The DC step, rise time and settling at this test point truly reflects the closed-loop response. Assuming a predominantly second order system, phase margin and/or damping factor can be estimated using the percentage of overshoot seen at this pin. The bandwidth can also be estimated by examining the rise time at the pin. The COMPna external capacitor shown in the Typical Application circuit will provide an adequate starting point for most applications. The programmable parameters that affect loop gain are the voltage range, bit[1] of the MFR_PWM_MODE command, the current range bit[7] of the MFR_PWM_MODE command, the gm of the PWM channel amplifier bits [7:5] of MFR_PWM_COMP, and the internal RCOMP compensation resistor, bits[4:0] of MFR_PWM_COMP. Be sure to establish these settings prior to compensation calculation. The COMPna series internal RCOMPn and external CCOMPna filter sets the dominant pole-zero loop compensation. The internal RCOMPn value can be modified (from 0Ω to 62kΩ) using bits[4:0] of the MFR_PWM_ COMP command. Adjust the value of RCOMPn to optimize transient response once the final PCB layout is done and the particular CCOMPnb filter capacitor and output capacitor type and value have been determined. The output capacitors need to be selected because the various types and values determine the loop gain and phase. An output current pulse of 20% to 80% of full-load current having a rise time of 1µs to 10µs will produce output voltage and COMP pin waveforms that will give a sense of the overall loop stability without breaking the feedback loop. Placing a power MOSFET with a resistor to ground directly across the output capacitor and driving the gate with an appropriate signal generator is a practical way to produce to a load step. The MOSFET + RSERIES will produce output currents approximately equal to VOUT/RSERIES. RSERIES values from 0.1Ω to 2Ω are valid depending on the current limit settings and the programmed output voltage. The initial output voltage step resulting from the step change in output current may not be within the bandwidth of the feedback loop, so this signal cannot be used to determine phase margin. This is why it is better to look at the COMP pin signal which is in the feedback loop and is the filtered and compensated control loop response. The gain of the loop will be increased by increasing RCOMP. If RCOMP is increased by the same factor that CCOMPL is decreased, the zero frequency will be kept the same, thereby keeping the phase shift the same in the most critical frequency range of the feedback loop. The gain of the loop will be proportional to the transconductance of the error amplifier which is set using bits[7:5] of the MFR_PWM_COMP command. The output voltage settling behavior is related to the stability of the closed-loop system and will demonstrate the actual overall supply performance. A second, more severe transient is caused by switching in loads with large (>1µF) supply bypass capacitors. The discharged bypass capacitors are effectively put in parallel with COUT, causing a rapid drop in VOUT. No regulator can alter its delivery of current quickly enough to prevent this sudden step change in output voltage if the load switch resistance is low and it is driven quickly. If the ratio of CLOAD to Rev. B For more information www.analog.com 59 LTM4680 APPLICATIONS INFORMATION COUT is greater than 1:50, the switch rise time should be controlled so that the load rise time is limited to approximately 25 • CLOAD. Thus a 10µF capacitor would require a 250µs rise time, limiting the charging current to about 200mA. PolyPhase Configuration When configuring a PolyPhase rail with multiple LTM4680s, the user must share the SYNC, COMP, SHARE_ CLK, FAULT, and ALERT pins of these parts. Be sure to use pull-up resistors on FAULT, SHARE_CLK and ALERT. One of the part’s SYNC pins must be set to the desired switching frequency, and all other FREQUENCY_SWITCH commands must be set to External Clock. If an external oscillator is provided, set the FREQUENCY_SWITCH command to External Clock for all parts. The relative phasing of all the channels should be spaced equally. The MFR_ RAIL_ ADDRESS of all the devices should be set to the same value. Multiple channels need to tie all the VOSNSn+ pins together, and all the VOSNSn– pins together, COMPna and COMPnb pins together as well. Do not assert bit[4] of MFR_CONFIG_ALL except in a PolyPhase application. See application example Figure 47. CONNECTING THE USB TO I2C/SMBUS/PMBUS CONTROLLER TO THE LTM4680 IN SYSTEM The ADI USB-to-I2C/SMBus/PMBus adapter (DC1613A or equivalent) can be interfaced to the LTM4680 on the user’s board for programming, telemetry and system debug. The adapter, when used in conjunction with LTpowerPlay, provides a powerful way to debug an entire power system. Faults are quickly diagnosed using telemetry, fault status commands and the fault log. The final configuration can be quickly developed and stored to the LTM4680 EEPROM. Figure 30 illustrates the application schematic for powering, programming and communication with one or more LTM4680s via the ADI I2C/SMBus/PMBus adapter regardless of whether or not system power is present. If system power is not present, the dongle will power the LTM4680 through the VDD33 supply pin. To initialize the part when VIN is not applied and the VDD33 pin is powered, use global address 0x5B command 0xBD data 0x2B followed by address 0x5B command 0xBD data 0xC4. The LTM4680 can now communicate with the internal EEPROM and read the project file. To write the updated project file to the NVM issue a STORE_USER _ALL command. When VIN is applied, a MFR_RESET must be issued to allow the PWM POWER to be enabled and valid ADCs to be read. VIN LTC CONTROLLER HEADER ISOLATED 3.3V SDA 100k 100k VIN VDD33 TP0101K SCL 1µF 10k VDD25 1µF LTM4680 SDA 10k SCL WP PGND/SGND TO LTC DC1613 USB TO I2C/SMBus/PMBus CONTROLLER VIN TP0101K VDD33 1µF VDD25 1µF LTM4680 SDA VGS MAX ON THE TP0101K IS 8V IF VIN > 16V CHANGE THE RESISTOR DIVIDER ON THE PFET GATE SCL WP PGND/SGND 4680 F30 Figure 30. Controller Connection 60 Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION Because of the adapter’s limited current sourcing capability, only the LTM4680s, their associated pull-up resistors and the I2C pull-up resistors should be powered from the VDD33 3.3V supply. In addition any device sharing the I2C bus connections with the LTM4680 should not have body diodes between the SDA/SCL pins and their respective VDD node because this will interfere with bus communication in the absence of system power. If VIN is applied, the DC1613A will not supply the power to the LTM4680s on the board. It is recommended the RUNn pins be held low or no voltage configuration resistors inserted to avoid providing power to the load until the part is fully configured. The LTM4680 is fully isolated from the host PC’s ground by the DC1613A.The 3.3V from the adapter and the LTM4680 VDD33 pin must be driven to each LTM4680 with a separate PFET. If both VIN and EXTVCC are not applied, the VDD33 pins can be in parallel because the on-chip LDO is off. The controller 3.3V current limit is 100mA but typical VDD33 currents are under 15mA. The VDD33 does back drive the INTVCC/EXTVCC pin. Normally this is not an issue if VIN is open. LTpowerPlay: AN INTERACTIVE GUI FOR DIGITAL POWER LTpowerPlay (Figure 31) is a powerful Windows-based development environment that supports Analog Devices digital power system management ICs including the LTM4680. The software supports a variety of different tasks. LTpowerPlay can be used to evaluate Analog Devices ICs by connecting to a demo board or the user application. LTpowerPlay can also be used in an offline mode (with no hardware present) in order to build multiple IC configuration files that can be saved and reloaded at a later time. LTpowerPlay provides unprecedented diagnostic and debug features. It becomes a valuable diagnostic tool during board bring-up to program or tweak the power system or to diagnose power issues when bring up rails. LTpowerPlay utilizes Analog Devices’s USB-to-I2C/ SMBus/PMBus adapter to communication with one of the many potential targets including the DC2844A demo board, the DC2298A socketed programming board, or a customer target system. The software also provides an automatic update feature to keep the revisions current with the latest set of device drivers and documentation. A great deal of context sensitive help is available with LTpowerPlay along with several tutorial demos. Complete information is available at LTpowerPlay. PMBus COMMUNICATION AND COMMAND PROCESSING The LTM4680 has a one deep buffer to hold the last data written for each supported command prior to processing as shown in Figure 32, Write Command Data Processing. When the part receives a new command from the bus, it copies the data into the Write Command Data Buffer, indicates to the internal processor that this command data needs to be fetched, and converts the command to its internal format so that it can be executed. Two distinct parallel blocks manage command buffering and command processing (fetch, convert, and execute) to ensure the last data written to any command is never lost. Command data buffering handles incoming PMBus writes by storing the command data to the Write Command Data Buffer and marking these commands for future processing. The internal processor runs in parallel and handles the sometimes slower task of fetching, converting and executing commands marked for processing. Some computationally intensive commands (e.g., timing parameters, temperatures, voltages and currents) have internal processor execution times that may be long relative to PMBus timing. If the part is busy processing a command, and new command(s) arrive, execution may be delayed or processed in a different order than received. The part indicates when internal calculations are in process via bit 5 of MFR_COMMON (“calculations not pending”). When the part is busy calculating, bit 5 is cleared. When this bit is set, the part is ready for another command. An example polling loop is provided in Figure 33 which ensures that commands are processed in order while simplifying error handling routines. When the part receives a new command while it is busy, it will communicate this condition using standard PMBus protocol. Depending on part configuration it may either NACK the command or return all ones (0xFF) for reads. It may also generate a BUSY fault and ALERT notification, Rev. B For more information www.analog.com 61 LTM4680 APPLICATIONS INFORMATION Figure 31. LTpowerPlay Screen Shot CMD PMBus WRITE WRITE COMMAND DATA BUFFER DECODER CMDS DATA MUX CALCULATIONS PENDING S R PAGE • • • VOUT_COMMAND 0x00 0x21 • • • MFR_RESET INTERNAL PROCESSOR FETCH, CONVERT DATA AND EXECUTE 0xFD x1 4680 F32 Figure 32. Write Command Data Processing 62 Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION or stretch the SCL clock low. For more information refer to PMBus Specification v1.1, Part II, Section 10.8.7 and SMBus v2.0 section 4.3.3. Clock stretching can be enabled by asserting bit 1 of MFR_CONFIG_ ALL. Clock stretching will only occur if enabled and the bus communication speed exceeds 100kHz. is to create a SAFE_WRITE_BYTE() and SAFE_WRITE_ WORD() subroutine. The above polling mechanism allows your software to remain clean and simple while robustly communicating with the part. For a detailed discussion of these topics and other special cases please refer to Analog Devices application notes. // wait until chip is not busy do { mfrCommonValue = PMBUS_READ_BYTE(0xEF); partReady = (mfrCommonValue & 0x68) == 0x68; }while(!partReady) When communicating using bus speeds at or below 100kHz, the polling mechanism shown here provides a simple solution that ensures robust communication without clock stretching. At bus speeds in excess of 100kHz, it is strongly recommended that the part be configured to enable clock stretching. This requires a PMBus master that supports clock stretching. System software that detects and properly recovers from the standard PMBus NACK/ BUSY faults as described in the PMBus Specification v1.1, Par II, Section 10.8.7 is required to communicate The LTM4680 is not recommended in applications with bus speeds in excess of 400kHz. // now the part is ready to receive the next command PMBUS_WRITE_WORD(0x21, 0x2000); //write VOUT_ COMMAND to 2V Figure 33. Example of a Command Write of VOUT_COMMAND PMBus busy protocols are well accepted standards, but can make writing system level software somewhat complex. The part provides three ‘hand shaking’ status bits which reduce complexity while enabling robust system level communication. The three hand shaking status bits are in the MFR_ COMMON register. When the part is busy executing an internal operation, it will clear bit 6 of MFR_COMMON (‘chip not busy’). When the part is busy specifically because it is in a transitional VOUT state (margining hi/lo, power off/ on, moving to a new output voltage set point, etc.) it will clear bit 4 of MFR_COMMON (‘output not in transition’). When internal calculations are in process, the part will clear bit 5 of MFR_COMMON (‘calculations not pending’). These three status bits can be polled with a PMBus read byte of the MFR_COMMON register until all three bits are set. A command immediately following the status bits being set will be accepted without NACKing or generating a BUSY fault/ALERT notification. The part can NACK commands for other reasons, however, as required by the PMBus spec (for instance, an invalid command or data). An example of a robust command write algorithm for the VOUT_COMMAND register is provided in Figure 33. It is recommended that all command writes (write byte, write word, etc.) be preceded with a polling loop to avoid the extra complexity of dealing with busy behavior and unwanted ALERT notification. A simple way to achieve this THERMAL CONSIDERATIONS AND OUTPUT CURRENT DERATING The thermal resistances reported in the Pin Configuration section of this data sheet are consistent with those parameters defined by JESD51-12 and are intended for use with finite element analysis (FEA) software modeling tools that leverage the outcome of thermal modeling, simulation, and correlation to hardware evaluation performed on a µModule package mounted to a hardware test board defined by JESD51-9 (“Test Boards for Area Array Surface Mount Package Thermal Measurements”). The motivation for providing these thermal coefficients is found in JESD51-12 (“Guidelines for Reporting and Using Electronic Package Thermal Information”). Many designers may opt to use laboratory equipment and a test vehicle such as the demo board to predict the µModule regulator’s thermal performance in their application at various electrical and environmental operating conditions to compliment any FEA activities. Without FEA software, the thermal resistances reported in the Pin Configuration section are in-and-of themselves not relevant to providing guidance of thermal performance; instead, the derating curves provided later in this data sheet Rev. B For more information www.analog.com 63 LTM4680 APPLICATIONS INFORMATION can be used in a manner that yields insight and guidance pertaining to one’s application-usage, and can be adapted to correlate thermal performance to one’s own application. The Pin Configuration section gives four thermal coefficients explicitly defined in JESD51-12; these coefficients are quoted or paraphrased below: 1. θJA, the thermal resistance from junction to ambient, is the natural convection junction-to-ambient air thermal resistance measured in a one cubic foot sealed enclosure. This environment is sometimes referred to as “still air” although natural convection causes the air to move. This value is determined with the part mounted to a JESD51-9 defined test board, which does not reflect an actual application or viable operating condition. 2. θJCbottom, the thermal resistance from junction to the bottom of the product case, is determined with all of the component power dissipation flowing through the bottom of the package. In the typical µModule regulator, the bulk of the heat flows out the bottom of the package, but there is always heat flow out into the ambient environment. As a result, this thermal resistance value may be useful for comparing packages but the test conditions don’t generally match the user’s application. 3. θJCtop, the thermal resistance from junction to top of the product case, is determined with nearly all of the component power dissipation flowing through the top of the package. As the electrical connections of the typical µModule regulator are on the bottom of the package, it is rare for an application to operate such that most of the heat flows from the junction to the top of the part. As in the case of θJCbottom, this value may be useful for comparing packages but the test conditions don’t generally match the user’s application. 4 θJB, the thermal resistance from junction to the printed circuit board, is the junction-to-board thermal resistance where almost all of the heat flows through the bottom of the µModule regulator and into the board, and is really the sum of the θJCbottom and the thermal resistance of the bottom of the part through the solder joints and through a portion of the board. The board temperature is measured a specified distance from the package, using a two sided, two layer board. This board is described in JESD51-9. A graphical representation of the aforementioned thermal resistances is given in Figure 34; blue resistances are contained within the µModule regulator, whereas green resistances are external to the µModule package. As a practical matter, it should be clear to the reader that no individual or sub-group of the four thermal resistance parameters defined by JESD51-12 or provided in the Pin Configuration section replicates or conveys normal operating conditions of a µModule regulator. For example, in normal board-mounted applications, never does 100% of the device’s total power loss (heat) thermally conduct exclusively through the top or exclusively through bottom of the µModule package—as the standard defines JUNCTION-TO-AMBIENT THERMAL RESISTANCE COMPONENTS JUNCTION-TO-CASE (TOP) RESISTANCE JUNCTION CASE (TOP)-TO-AMBIENT RESISTANCE JUNCTION-TO-BOARD RESISTANCE JUNCTION-TO-CASE CASE (BOTTOM)-TO-BOARD (BOTTOM) RESISTANCE RESISTANCE AMBIENT BOARD-TO-AMBIENT RESISTANCE 4680 F33 µModule DEVICE Figure 34. Graphical Representation of JESD51-12 Thermal Coefficients 64 For more information www.analog.com Rev. B LTM4680 APPLICATIONS INFORMATION for θJCtop and θJCbottom, respectively. In practice, power loss is thermally dissipated in both directions away from the package—granted, in the absence of a heat sink and airflow, a majority of the heat flow is into the board. Within the LTM4680, be aware there are multiple power devices and components dissipating power, with a consequence that the thermal resistances relative to different junctions of components or die are not exactly linear with respect to total package power loss. To reconcile this complication without sacrificing modeling simplicity— but also, not ignoring practical realities—an approach has been taken using FEA software modeling along with laboratory testing in a controlled-environment chamber to reasonably define and correlate the thermal resistance values supplied in this data sheet: (1) Initially, FEA software is used to accurately build the mechanical geometry of the LTM4680 and the specified PCB with all of the correct material coefficients along with accurate power loss source definitions; (2) this model simulates a softwaredefined JEDEC environment consistent with JESD51-9 and JESD51-12 to predict power loss heat flow and temperature readings at different interfaces that enable the calculation of the JEDEC-defined thermal resistance values; (3) the model and FEA software is used to evaluate the LTM4680 with heat sink and airflow; (4) having solved for and analyzed these thermal resistance values and simulated various operating conditions in the software model, a thorough laboratory evaluation replicates the simulated conditions with thermocouples within a controlled environment chamber while operating the device at the same power loss as that which was simulated. The outcome of this process and due diligence yields the set of derating curves provided in later sections of this data sheet, along with well-correlated JESD51-12-defined θ values provided in the Pin Configuration section of this data sheet. The 5V, 8V and 12V power loss curves in Figure  35, Figure 36 and Figure 37 respectively can be used in coordination with the load current derating curves in Figure 38 to Figure 43 for calculating an approximate θJA thermal resistance for the LTM4680 with various heat sinking and airflow conditions. These thermal resistances represent demonstrated performance of the LTM4680 on hardware; a 6-layer FR4 PCB measuring 99mm × 130mm × 1.6mm using 2oz copper on all layers. The power loss curves are taken at room temperature, and are increased with multiplicative factors of 1.35 when the junction temperature reaches 125°C. The derating curves are plotted with the LTM4680’s paralleled outputs initially sourcing up to 60A and the ambient temperature at 25°C. The output voltages are 0.9V and 1.8V. These are chosen to include the lower and higher output voltage ranges for correlating the thermal resistance. Thermal models are derived from several temperature measurements in a controlled temperature chamber along with thermal modeling analysis. The junction temperatures are monitored while ambient temperature is increased with and without airflow. The power loss increase with ambient temperature change is factored into the derating curves. The junctions are maintained at 125°C maximum while lowering output current or power while increasing ambient temperature. The decreased output current decreases the internal module loss as ambient temperature is increased. The monitored junction temperature of 125°C minus the ambient operating temperature specifies how much module temperature rise can be allowed. As an example in Figure 40, the load current is derated to ~50A at ~75°C ambient with no air or heat sink and the room temperature (25°C) power loss for this 12VIN to 0.9VOUT at 50AOUT condition is ~5W. A 6.75W loss is calculated by multiplying the ~5W room temperature loss from the 12VIN to 0.9VOUT power loss curve at 50A (Figure 37), with the 1.35 multiplying factor. If the 75°C ambient temperature is subtracted from the 125°C junction temperature, then the difference of 50°C divided by 6.75W yields a thermal resistance, θJA, of 7.4°C/W—in good agreement with Table 10. Tables 10 and 11 provide equivalent thermal resistances for 0.9V and 1.8V outputs with and without airflow. The derived thermal resistances in Tables 10 and 11 for the various conditions can be multiplied by the calculated power loss as a function of ambient temperature to derive temperature rise above ambient, thus maximum junction temperature. Room temperature power loss can be derived from the efficiency curves in the Typical Performance Characteristics section and adjusted with the above ambient temperature multiplicative factors. Rev. B For more information www.analog.com 65 LTM4680 APPLICATIONS INFORMATION Tables 10 thru 11: Output Current Derating Table 10. 0.9V Output DERATING CURVE Figure 38 to Figure 40 Figure 38 to Figure 40 Figure 38 to Figure 40 VIN (V) 5, 8, 12 5, 8, 12 5, 8, 12 POWER LOSS CURVE Figure 35 to Figure 37 Figure 35 to Figure 37 Figure 35 to Figure 37 AIRFLOW (LFM) 0 200 400 HEAT SINK None None None θJA (°C/W) 7 6 5 VIN (V) 5, 8, 12 5, 8, 12 5, 8, 12 POWER LOSS CURVE Figure 35 to Figure 37 Figure 35 to Figure 37 Figure 35 to Figure 37 AIRFLOW (LFM) 0 200 400 HEAT SINK None None None θJA (°C/W) 7 6 5 Table 11. 1.8V Output DERATING CURVE Figure 41 to Figure 43 Figure 41 to Figure 43 Figure 41 to Figure 43 Table 12. Channel Output Voltage vs Capacitor Selection, All Ceramic Configuration, 15A to 30A Load Step with 15A/µs Slew Rate VIN (V) VOUT VOUT ILIM COUT (V) RANGE RANGE (CER CAP) COUT (BULK CAP) CCOMP B (pF) CCOMP A (nF) RCOMP (kΩ) EA-GM (mS) fSW (kHz) PK-PK RECOVERY LOAD STEP DEVIATION TIME (A) (mV) (μS) 5 0.9 Low Low *330µFX7 None 68 3.3 11 5.04 250 15 to 30 104 40 12 0.9 Low Low *330µFX7 None 68 3.3 11 5.04 250 15 to 30 104 40 15 0.9 Low Low *330µFX7 None 68 3.3 11 5.04 250 15 to 30 105 40 5 1 Low Low *330µFX7 None 68 3.3 11 5.04 250 15 to 30 104 40 12 1 Low Low *330µFX7 None 68 3.3 11 5.04 250 15 to 30 104 40 15 1 Low Low *330µFX7 None 68 3.3 11 5.04 250 15 to 30 105 40 5 0.9 Low Low *330µFX6 None 68 3.3 9 5.76 350 15 to 30 102 30 12 0.9 Low Low *330µFX6 None 68 3.3 9 5.76 350 15 to 30 99 30 15 0.9 Low Low *330µFX6 None 68 3.3 9 5.76 350 15 to 30 100 30 5 1 Low Low *330µFX6 None 68 3.3 9 5.76 350 15 to 30 102 30 12 1 Low Low *330µFX6 None 68 3.3 9 5.76 350 15 to 30 102 30 15 1 Low Low *330µFX6 None 68 3.3 9 5.76 350 15 to 30 99 30 6 1.2 Low Low *330µFX5 None 68 3.3 9 5.76 350 15 to 30 115 30 12 1.2 Low Low *330µFX5 None 68 3.3 9 5.76 350 15 to 30 112 30 15 1.2 Low Low *330µFX5 None 68 3.3 9 5.76 350 15 to 30 110 30 6 1.5 Low Low *330µFX5 None 68 3.3 9 5.76 425 15 to 30 115 30 12 1.5 Low Low *330µFX5 None 68 3.3 9 5.76 425 15 to 30 109 30 15 1.5 Low Low *330µFX5 None 68 3.3 9 5.76 425 15 to 30 110 30 6 1.8 Low Low *330µFX5 None 68 3.3 5 5.76 500 15 to 30 141 25 12 1.8 Low Low *330µFX5 None 68 3.3 5 5.76 500 15 to 30 132 25 15 1.8 Low Low *330µFX5 None 68 3.3 5 5.76 500 15 to 30 132 25 6 2.5 Low Low *330µFX5 None 68 3.3 5 5.04 575 15 to 30 176 25 12 2.5 Low Low *330µFX5 None 68 3.3 5 5.04 575 15 to 30 146 25 15 2.5 Low Low *330µFX5 None 68 3.3 5 5.04 575 15 to 30 146 25 8 3.3 High Low *330µFX5 None 68 3.3 9 5.76 650 15 to 30 191 40 12 3.3 High Low *330µFX5 None 68 3.3 9 5.76 650 15 to 30 166 40 15 3.3 High Low *330µFX5 None 68 3.3 9 5.76 650 15 to 30 166 40 * Murata GRM32ER60G337ME05L, 330μF, 4V, X5R 66 Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION Table 13. Channel Output Voltage vs Capacitor Selection, Bulk and Ceramic Cap Configuration, 15A to 30A Load Step with 15A/µs Slew Rate VIN (V) VOUT VOUT ILIM (V) RANGE RANGE COUT (CER CAP) COUT (BULK CAP) CCOMP B (pF) CCOMP A (nF) RCOMP (kΩ) EA-GM (mS) PK-PK RECOVERY fSW LOAD STEP DEVIATION TIME (kHz) (A) (mV) (μS) 5 0.9 Low Low *100µFX4 **470µFX3 68 3.3 17 3.69 250 15 to 30 99 50 12 0.9 Low Low *100µFX4 **470µFX3 68 3.3 17 3.69 250 15 to 30 97 50 15 0.9 Low Low *100µFX4 **470µFX3 68 3.3 17 3.69 250 15 to 30 99 50 5 1 Low Low *100µFX5 **470µFX2 68 3.3 17 3.69 250 15 to 30 114 50 12 1 Low Low *100µFX5 **470µFX2 68 3.3 17 3.69 250 15 to 30 115 50 15 1 Low Low *100µFX5 **470µFX2 68 3.3 17 3.69 250 15 to 30 114 50 5 0.9 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 102 50 12 0.9 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 100 50 15 0.9 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 102 50 5 1 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 105 50 12 1 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 104 50 15 1 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 104 50 5 1.2 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 107 50 12 1.2 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 102 50 15 1.2 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 350 15 to 30 104 50 5 1.5 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 425 15 to 30 105 50 12 1.5 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 425 15 to 30 97 50 15 1.5 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 425 15 to 30 97 50 6 1.8 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 500 15 to 30 100 50 12 1.8 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 500 15 to 30 94 50 15 1.8 Low Low *100µFX4 **470µFX2 68 3.3 17 3.69 500 15 to 30 95 50 6 2.5 Low Low *100µFX4 ***470µFX2 68 3.3 20 1.68 575 15 to 30 156 80 12 2.5 Low Low *100µFX4 ***470µFX2 68 3.3 20 1.68 575 15 to 30 136 80 15 2.5 Low Low *100µFX4 ***470µFX2 68 3.3 20 1.68 575 15 to 30 136 80 6 3.3 High Low *100µFX4 ***470µFX2 68 3.3 20 3.02 650 15 to 30 177 80 12 3.3 High Low *100µFX4 ***470µFX2 68 3.3 20 3.02 650 15 to 30 144 80 15 3.3 High Low *100µFX4 ***470µFX2 68 3.3 20 3.02 650 15 to 30 141 80 * Murata GRM32ER60G337ME05L, 330μF, 4V, X5R ** Panasonic EEFGX0D471R, 470µF, 2.0V, 3mΩ—Used on Up to 1.8V Output *** Panasonic 4TPF470ML, 470µF, 4V, 10mΩ—Used on 2.5V and 3.3V Output Rev. B For more information www.analog.com 67 LTM4680 APPLICATIONS INFORMATION Table 14. Dual Phase Single Output Voltage vs Capacitor Selection, Bulk and Ceramic Cap Configuration, 30A to 60A Load Step with 30A/µs Slew Rate VIN (V) VOUT VOUT ILIM (V) RANGE RANGE COUT (CER CAP) COUT (BULK CAP) CCOMP B (pF) CCOMP A (nF) RCOMP (kΩ) EA-GM (mS) PK-PK RECOVERY fSW LOAD STEP DEVIATION TIME (kHz) (A) (mV) (μS) 6 1 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 350 30 to 60 91.7 30 12 1 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 350 30 to 60 87.7 30 15 1 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 350 30 to 60 87 30 6 1.5 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 425 30 to 60 89 30 12 1.5 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 425 30 to 60 82.3 30 15 1.5 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 425 30 to 60 80.3 30 6 1.8 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 500 30 to 60 91 30 12 1.8 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 500 30 to 60 79 30 15 1.8 Low Low *100µFx8 **470µFx4 68 3.3 15 3.69 500 30 to 60 79.7 30 * Murata GRM32ER60G337ME05L, 330μF, 4V, X5R ** Panasonic EEFGX0D471R, 470µF, 2.0V, 3mΩ—Used on Up to 1.8V Output 68 Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION-DERATING CURVES DERATING CURVES 8 6 4 8 4 10 20 30 40 LOAD CURRENT (A) 50 0 60 0 10 20 30 40 LOAD CURRENT (A) 50 40 20 0LFM 200LFM 400LFM 0 25 50 75 100 125 AMBIENT TEMPERATURE (°C) 40 20 0LFM 200LFM 400LFM 0 25 50 75 100 125 AMBIENT TEMPERATURE (°C) 4680 F38 20 0 150 0 150 4680 F41 Figure 41. 5V to 1.8V Derating Curve, No Heat Sink 0 25 50 75 100 125 AMBIENT TEMPERATURE (°C) 80 60 40 20 0 150 Figure 40. 12V to 0.9V Derating Curve, No Heat Sink MAXIMUM LOAD CURRENT (A) MAXIMUM LOAD CURRENT (A) 25 50 75 100 125 AMBIENT TEMPERATURE (°C) 0LFM 200LFM 400LFM 4680 F40 80 0LFM 200LFM 400LFM 60 40 Figure 39. 8V to 0.9V Derating Curve, No Heat Sink 80 20 50 60 4680 F39 Figure 38. 5V to 0.9V Derating Curve, No Heat Sink 40 20 30 40 LOAD CURRENT (A) 80 60 0 150 60 10 Figure 37. 12VIN Power Loss Curve MAXIMUM LOAD CURRENT (A) 60 0 4680 F37 80 MAXIMUM LOAD CURRENT (A) MAXIMUM LOAD CURRENT (A) 0 60 Figure 36. 8VIN Power Loss Curve 80 MAXIMUM LOAD CURRENT (A) 4 4680 F36 Figure 35. 5VIN Power Loss Curve 0 6 2 4680 F35 0 8 2 0 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 1.8V, 500kHz 2.5V, 575kHz 3.3V, 650kHz 10 6 2 0 12 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 1.8V, 500kHz 2.5V, 575kHz 3.3V, 650kHz 10 POWER LOSS (W) 10 POWER LOSS (W) 12 0.9V, 250kHz 1.0V, 250kHz 1.2V, 350kHz 1.5V, 425kHz 1.8V, 500kHz 2.5V, 575kHz 3.3V, 650kHz POWER LOSS (W) 12 0LFM 200LFM 400LFM 0 25 50 75 100 125 AMBIENT TEMPERATURE (°C) 150 4680 F42 Figure 42. 8V to 1.8V Derating Curve, No Heat Sink 60 40 20 0 0LFM 200LFM 400LFM 0 25 50 75 100 125 AMBIENT TEMPERATURE (°C) 150 4680 F43 Figure 43. 12V to 1.8V Derating Curve, No Heat Sink Rev. B For more information www.analog.com 69 LTM4680 APPLICATIONS INFORMATION EMI PERFORMANCE SAFETY CONSIDERATIONS The SWn pin provides access to the midpoint of the power MOSFETs in LTM4680’s power stages. The LTM4680 modules do not provide galvanic isolation from VIN to VOUT. There is no internal fuse. If required, a slow blow fuse with a rating twice the maximum input current needs to be provided to protect each unit from catastrophic failure. Connecting an optional series RC network from SWn to GND can dampen high frequency (~30MHz+) switch node ringing caused by parasitic inductances and capacitances in the switched-current paths. The RC network is called a snubber circuit because it dampens (or “snubs”) the resonance of the parasitics, at the expense of higher power loss. To use a snubber, choose first how much power to allocate to the task and how much PCB real estate is available to implement the snubber. For example, if PCB space allows a low inductance 0.5W resistor to be used then the capacitor in the snubber network (CSW) is computed by: CSW = PSNUB VINn (MAX)2 • fSW where VINn(MAX) is the maximum input voltage that the input to the power stage (VINn) will see in the application, and fSW is the DC/DC converter’s switching frequency of operation. CSW should be NPO, C0G or X7R-type (or better) material. The snubber resistor (RSW) value is then given by: RSW = 5nH CSW The fuse or circuit breaker should be selected to limit the current to the regulator during overvoltage in case of an internal top MOSFET fault. If the internal top MOSFET fails, then turning it off will not resolve the overvoltage, thus the internal bottom MOSFET will turn on indefinitely trying to protect the load. Under this fault condition, the input voltage will source very large currents to ground through the failed internal top MOSFET and enabled internal bottom MOSFET. This can cause excessive heat and board damage depending on how much power the input voltage can deliver to this system. A fuse or circuit breaker can be used as a secondary fault protector in this situation. The device does support over current and overtemperature protection. LAYOUT CHECKLIST/EXAMPLE The high integration of LTM4680 makes the PCB board layout very simple and easy. However, to optimize its electrical and thermal performance, some layout considerations are still necessary. Use large PCB copper areas for high current paths, including VINn, GND and VOUTn. It helps to minimize the PCB conduction loss and thermal stress. n The snubber resistor should be low ESL and capable of withstanding the pulsed currents present in snubber circuits. A value between 0.7Ω and 4.2Ω is normal. A 2.2nF snubber capacitor is a good value to start with in series with the snubber resistor to ground. The no load input quiescent current can be monitored while selecting different RC series snubber components to get a increased power loss versus switch node ringing attenuation. n n n 70 Place high frequency ceramic input and output capacitors next to the VINn, GND and VOUTn pins to minimize high frequency noise. Place a dedicated power ground layer underneath the module. To minimize the via conduction loss and reduce module thermal stress, use multiple vias for interconnection between top layer and other power layers. Rev. B For more information www.analog.com LTM4680 APPLICATIONS INFORMATION Do not put vias directly on pads, unless they are capped or plated over. n n Use a separate SGND copper plane for components connected to signal pins. Connect SGND to GND local to the LTM4680. n n Use Kelvin sense connections across the input RSENSE resistor if input current monitoring is used. GND n For parallel modules, tie the VOUTn, ,VOSNSn+/VOSNSn– voltage-sense differential pair lines, RUNn, , COMPna, COMPnb pin together. The user must share the SYNC, SHARE_CLK, FAULT, and ALERT pins of these parts. Be sure to use pull-up resistors on FAULT, SHARE_ CLK and ALERT. Bring out test points on the signal pins for monitoring. Figure 44 gives a good example of the recommended layout. GND GND VOUT1 VOUT0 GND GND VOUT1 VOUT0 GND GND GND GND VIN OPTIONAL INPUT CURRENT SENSE VIN VSUPPLY GND GND 4680 F44a 4680 F44b (b) BOTTOM LAYER (a) TOP LAYER Figure 44. Recommended PCB Layout Package Top View Rev. B For more information www.analog.com 71 LTM4680 TYPICAL APPLICATIONS VDD33 10k 2.2µF 150µF TSNS1b TSNS1a TSNS0a PGOOD1 PGOOD0 EXTVCC INTVCC IN+ VDD25 VDD33 VIN 5.75V TO 16V TSNS0b PGOOD VDD33 SW0 VOUT0 1mΩ 100µF ×5 IN– VIN0 4.99k 10k 10k ON/OFFCONFIG FAULT INTERRUPTS LTM4680 RUN1 470µF ×2 LOAD SCL SDA ALERT GND FAULT1 FSWPH_CFG VOUT1_CFG VOUT0_CFG VTRIM1_CFG COMP0b COMP0a COMP1b SHARE_CLK VTRIM0_CFG SYNC COMP1a + VOSNS1– FAULT0 WP 100µF ×5 VOSNS1+ RUN0 470µF ×2 0.9V AT 60A VOSNS0+ VOSNS0– SW1 VOUT1 SVIN VDD33 10k VIN1 10k SGND 100pF 825Ω • SLAVE ADDRESS = 1001110_R/W (0X4E) • 350kHz SWITCHING FREQUENCY • NO GUI CONFIGURATION AND NO PART-SPECIFIC PROGRAMMING REQUIRED EXCEPT: VIN_OFF < VIN_UV_WARN_LIMIT, VIN_ON
LTM4680IY 价格&库存

很抱歉,暂时无法提供与“LTM4680IY”相匹配的价格&库存,您可以联系我们找货

免费人工找货