0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MAX4917AEUK+TG128

MAX4917AEUK+TG128

  • 厂商:

    AD(亚德诺)

  • 封装:

    SC-74A

  • 描述:

    INTEGRATED CIRCUIT

  • 数据手册
  • 价格&库存
MAX4917AEUK+TG128 数据手册
MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current General Description The MAX4914B/MAX4915A/B/MAX4917A/B family of switches feature internal current limiting to prevent damage to host devices due to faulty load conditions. These analog switches have a low 0.2Ω on-resistance and operate from a 2.3V to 5.5V input voltage range. They are available with guaranteed 100mA, 200mA, and 300mA current limits, making them ideal for SDIO and other load switching applications. When the switch is on and a load is connected to the port, a guaranteed blanking time of 14ms ensures that the transient voltages settle down. If after this blanking time the load current is greater than the current limit, the MAX4914B/MAX4915B/MAX4917B latchoff versions enter a latchoff state where the switch is turned off and FLAG is issued to the microprocessor. The switch can be turned on again by cycling the power or the ON pin. Benefits and Features ●● Guaranteed Current Limit: 100mA, 200mA, 300mA ●● Thermal-Shutdown Protection ●● Reverse Current Protection ●● 0.2Ω On-Resistance ●● 14ms Guaranteed Blanking Time ●● FLAG Function ●● 80μA Supply Current ●● 8μA Latchoff Current (MAX4914B/MAX4915B/MAX4917B) ●● Autoretry (MAX4915A/MAX4917A) ●● 0.01μA Shutdown Current ●● 2.3V to 5.5V Supply Range ●● Undervoltage Lockout The MAX4915A/MAX4917A have an autoretry feature where the switch turns off after the blanking time and then continuously checks to see if the overload condition is present. The switch turns on and remains on after the overload condition disappears and FLAG deasserts. ●● Fast Current-Limit Response Time (5μs) The MAX4914B is available in the tiny 6-pin μDFN (2mm x 2mm) package, while the MAX4915A/B and MAX4917A/B are available in both 6-pin μDFN (2mm x 2mm) and space-saving 5-pin SOT23 packages. These devices operate over the -40°C to +85°C extended temperature range. Applications Typical Operating Circuit appear at end of data sheet. end of data sheet. 19-0544; Rev 3; 1/16 ●● Low (0.1μA typ) Reverse Shutdown Current ●● Tiny 6-Pin μDFN (2mm x 2mm) and 5-Pin SOT23 Packages ●● ●● ●● ●● ●● ●● ●● PDAs and Palmtop Devices Cell Phones GPS Systems Handheld Devices SDIO USB Ports Notebook Computers MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Absolute Maximum Ratings IN, ON, FLAG, OUT to GND .....................................-0.3V to +6V OUT Short Circuit to GND .................................Internally Limited Continuous Power Dissipation (TA = +70°C) 5-Pin SOT23 (derate 7.1mW/°C above +70°C)...........571mW 6-Pin μDFN (derate 4.5mW/°C above +70°C).............358mW Operating Temperature Range............................ -40°C to +85°C Junction Temperature.......................................................+150°C Storage Temperature Range............................. -65°C to +150°C Lead Temperature (soldering, 10s).................................. +300°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Electrical Characteristics (VIN = +2.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +3.3V, TA = +25°C.) (Note 1) PARAMETER Operating Voltage Quiescent Current SYMBOL CONDITIONS VIN IQ VON = VIN, IOUT = 0, switch on MAX UNITS 5.5 V 80 120 VIN = +5.0V to +5.5V ILATCH VON = VIN, after an overcurrent fault MAX4914B/MAX4915B/MAX4917B (latchoff versions) Forward Shutdown Current ISHDN Reverse Shutdown Current ISHDN Forward Current Limit IFWD IREV TYP 2.3 VIN = +2.3V to +5.0V Latchoff Current (Note 2) Reverse Current Limit MIN 160 8 17 µA VON = 0, VOUT = 0, VIN = +5.5V 0.01 1 µA VON = 0, VOUT = +5.5V, VIN = +2.3V 0.01 1 µA MAX4914B, VOUT = GND 100 150 MAX4915_, VOUT = GND 200 300 MAX4917_, VOUT = GND 300 450 MAX4914B, VOUT - VIN ≥ 0.5V 150 MAX4915_, VOUT - VIN ≥ 0.5V 300 MAX4917_, VOUT - VIN ≥ 0.5V ON Input Leakage Undervoltage Lockout VON = VIN or GND UVLO Rising edge +1 1.75 2.25 100 RON ON Input Logic-High Voltage VIH ON Input Logic-Low Voltage VIL mA mA 450 -1 Undervoltage-Lockout Hysteresis On-Resistance µA TA = +25°C, IOUT = 95mA 0.2 TA = -40°C to +85°C, IOUT = 95mA 2.0 MAX4915A/MAX4917A 1.4 V mV 0.4 0.5 MAX4914B/MAX4915B/MAX4917B µA Ω V MAX4914B/MAX4915B/MAX4917B 0.8 MAX4915A/MAX4917A 0.4 FLAG Output Logic-Low Voltage ISINK = 1mA 0.4 V FLAG Output-High Leakage Current VON = VIN = VFLAG = +5.5V 1 µA Thermal Shutdown Thermal-Shutdown Hysteresis www.maximintegrated.com V +150 °C 15 °C Maxim Integrated │  2 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Electrical Characteristics (continued) (VIN = +2.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +3.3V, TA = +25°C.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS DYNAMIC CHARACTERISTICS Turn-On Time VON from low to high; IOUT = 10mA, CL = 0.1µF (Note 3) 100 µs Turn-Off Time VON from high to low; IOUT = 10mA, CL = 0.1µF (Note 3) 40 ns Blanking Time tBLANK Overcurrent fault (Figures 2, 3) Short-Circuit Current-Limit Response Time 14 60 VON = VIN = +3.3V, short circuit applied to OUT Retry Time (Note 4) tRETRY ms 5 MAX4915A/MAX4917A (autoretry versions) (Figure 2) (Note 4) µs 210 900 ms Note 1: All parts are 100% tested at +25°C. Limits across the full temperature range are guaranteed by design and correlation. Note 2: Latchoff current does not include the current flowing into FLAG. Note 3: The on-time is defined as the time taken for the current through the switch to go from 0mA to 10mA. The off-time is defined as the time taken for the current through the switch to go from 10mA to 0mA. Note 4: Retry time is typically 15 times the blanking time. Typical Operating Characteristics (VIN = 3.3V, TA = +25°C, unless otherwise noted.) 70 60 50 40 30 20 100 VIN = 5V 80 60 VIN = 3.3V 40 20 10 0 VON = VIN 2.0 2.5 3.0 3.5 4.0 4.5 SUPPLY VOLTAGE (V) www.maximintegrated.com 5.0 5.5 0 LATCHOFF CURRENT vs. TEMPERATURE 12 MAX4914A/B toc03 80 120 LATCHOFF CURRENT (µA) QUIESCENT CURRENT (µA) 90 QUIESCENT CURRENT vs. TEMPERATURE MAX4914A/B toc02 VON = VIN QUIESCENT CURRENT (µA) 100 MAX4914A/B toc01 QUIESCENT CURRENT vs. SUPPLY VOLTAGE VON = VIN 10 8 VIN = 5V 6 4 VIN = 3.3V 2 -40 -15 10 35 TEMPERATURE (°C) 60 85 0 -40 -15 10 35 60 85 TEMPERATURE (°C) Maxim Integrated │  3 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Typical Operating Characteristics (continued) (VIN = 3.3V, TA = +25°C, unless otherwise noted.) VCC = 3.3V 1 0.1 -15 10 35 60 VIN = 3.3V 0.1 0.01 -40 85 -15 TEMPERATURE (°C) 10 35 0.8 0.6 0.4 MAX4914A/B toc06 0.001 0.0001 -40 -15 10 35 60 85 TEMPERATURE (°C) 400 350 300 250 MAX4915_ 200 150 50 -15 10 35 60 VIN - VOUT (V) SWITCH TURN-ON/OFF TIMES vs. TEMPERATURE FLAG-BLANKING TIMEOUT vs. TEMPERATURE ON 1 OFF 0.1 -15 10 35 TEMPERATURE (°C) www.maximintegrated.com 0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 TEMPERATURE (°C) ILOAD = 10mA -40 0 85 60 85 50 FLAG-BLANKING TIMEOUT (ms) -40 MAX4914A/B toc09 SWITCH TURN-ON/OFF TIMES (µs) VIN = 3.3V 0.01 100 10 0.01 0.1 450 0.2 100 1 500 OUTPUT CURRENT (mA) NORMALIZED RON 1.0 0 VIN = 5V OUTPUT CURRENT vs. OUTPUT VOLTAGE MAX4914A/B toc07 VCC = 5V 1.2 85 10 TEMPERATURE (°C) NORMALIZED ON-RESISTANCE vs. TEMPERATURE 1.4 60 100 MAX4914A/B toc08 -40 VIN = 5V LATCHOFF LEAKAGE CURRENT vs. TEMPERATURE MAX4914A/B toc10 0.01 ON = GND, VOUT = 5.5V LATCHOFF LEAKAGE CURRENT (nA) 10 MAX4914A/B toc05 VCC = 5V 100 REVERSE SHUTDOWN CURRENT vs. TEMPERATURE 1 REVERSE SHUTDOWN CURRENT (nA) FORWARD SHUTDOWN CURRENT (nA) 1000 MAX4914A/B toc04 FORWARD SHUTDOWN CURRENT vs. TEMPERATURE 45 40 35 30 25 20 -40 -15 10 35 60 85 TEMPERATURE (°C) Maxim Integrated │  4 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Typical Operating Characteristics (continued) (VIN = 3.3V, TA = +25°C, unless otherwise noted.) CURRENT-LIMIT RESPONSE (VON RISING) MAX4914A/B toc11 CIN = 0.1µF COUT = 0.1µF CURRENT-LIMIT RESPONSE (VIN AND VON RISING TOGETHER) MAX4914A/B toc12 VIN 2V/div 0V VIN = VON 1V/div VON 2V/div 0V 0V IOUT 100mA/div CIN = 0.1µF COUT = 0.1µF 0mA 20µs/div CURRENT-LIMIT RESPONSE (OUT SHORTED TO GND) 20µs/div MAX4914A/B toc14 VIN 2V/div 0V VON 1V/div VOUT 2V/div 0V 0V CIN = 0.1µF COUT = 0.1µF IOUT 5A/div 0A 40µs/div FLAG-BLANKING RESPONSE TURN-OFF RESPONSE MAX4914A/B toc15 MAX4914A/B toc16 VON 1V/div CIN = 0.1µF COUT = 0.1µF www.maximintegrated.com VIN 2V/div 0V VON 2V/div 0V 0V 200ns/div IOUT 50mA/div 0mA 20µs/div CIN = 0.1µF COUT = 0.1µF 0mA TURN-ON RESPONSE MAX4914A/B toc13 CIN = 1µF COUT = 0.1µF IOUT 100mA/div VFLAG 2V/div IOUT 10mA/div 0V 0mA IOUT 200mA/div 0mA 10ms/div Maxim Integrated │  5 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Pin Configurations TOP VIEW IN 1 GND 2 + + 5 OUT MAX4915A/B MAX4917A/B IN 2 4 FLAG ON 3 N.C. 1 SOT23 6 ON MAX4914B MAX4915A/B MAX4917A/B OUT 3 5 GND 4 FLAG µDFN (2mm x 2mm) Pin Description PIN MAX4915A/B/ MAX4917A/B (SOT23) MAX4914A/B/ MAX4915A/B/ MAX4917A/B (µDFN) 1 2 IN 2 5 GND 3 6 ON 4 4 FLAG Fault Output. This open-drain output goes low when the device stays in forward or reverse current limit for more than the blanking time period. FLAG is high impedance when a fault is not present or when ON is low. 5 3 OUT Switch Output. Bypass with a 0.1µF ceramic capacitor to ground as close to the device as possible. — 1 N.C. No Connection. Not internally connected. www.maximintegrated.com NAME FUNCTION Input. Bypass with a 0.1µF ceramic capacitor to ground as close to the device as possible. Ground Active-High, Switch-On Input. A logic-high turns the switch on. Maxim Integrated │  6 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current REVERSE CURRENT DETECTOR FLAG BLANKING TIME CIRCUITRY N IN UNDERVOLTAGE LOCKOUT ON N FORWARD CURRENT DETECTOR OUT +2.0V LOGIC AUTORETRY MAX4914B MAX4915A/B MAX4917A/B GND Figure 1. Functional Diagram Detailed Description Reverse Current Protection The MAX4914B/MAX4915A/B/MAX4917A/B are forward/ reverse current-limited switches that operate from a +2.3V to +5.5V input voltage range and guarantee a 100mA, 200mA, and 300mA minimum current-limit threshold for different options. The voltage drop across an internal sense resistor is compared to two reference voltages to indicate a forward or reverse current-limit fault. When the load current exceeds the preset current limit for greater than the faultblanking time, the switch opens and FLAG asserts. All devices limit the reverse current (VOUT to VIN) from exceeding the maximum IREV value. The switch is shut off and FLAG is asserted if the reverse current-limit condition persists for more than the blanking time. This feature prevents excessive reverse currents from flowing through the device to the source. When the device is in shutdown (VON < VIL), the current from OUT to IN does not exceed 1μA (max). The MAX4915A/MAX4917A have an autoretry function that turns on the switch again after an internal retry time expires. If the faulty load condition is still present after the blanking time, the switch turns off again and the cycle is repeated. If the faulty load condition is not present, the switch remains on. During this retry time, FLAG remains low until the fault is removed. Toggle ON high to enable the current-limited switches. The switches are continuously on only if VIN exceeds the UVLO threshold (typically 2V) and there is no fault. When a forward/reverse current fault is present or the die exceeds the thermal-shutdown temperature of +150°C, OUT is internally disconnected from IN and the supply current decreases to 8μA (latchoff). The switch is now operating in one of its off states. The switch-off state also occurs when driving ON low, thus reducing the supply current (shutdown) to 0.01μA (typ). Table 1 illustrates the ON/OFF state. The MAX4914B/MAX4915B/MAX4917B do not have the autoretry option, and the switch remains in latchoff mode until the ON pin or the input power is cycled from high to low and then high again. Switch-On/Off Control The undervoltage-lockout (UVLO) circuit prevents erroneous switch operation when the input voltage goes too low. www.maximintegrated.com Maxim Integrated │  7 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Table 1. MAX4914B/MAX4915A/B/MAX4917A/B Switch Truth Table ON FAULT SWITCH ON/OFF SUPPLY CURRENT MODE Low X OFF Shutdown High Undervoltage lockout OFF Shutdown High Thermal High OFF immediately (tBLANK period does not apply) Latchoff OFF after tBLANK period has elapsed Latchoff ON during tBLANK period, OFF during tRETRY period for the MAX4915A/MAX4917A (autoretry versions); cycle repeats until fault is removed Current limit tBLANK tRETRY tBLANK See the Autoretry (MAX4915A/MAX4917A) section tBLANK CURRENT LIMIT SHORT CONDITION REMOVED ON SWITCH STATUS OFF FLAG STATUS Figure 2. MAX4915A/MAX4917A Autoretry Fault-Blanking Diagram FLAG Indicator All devices feature a latched fault output, FLAG. Whenever a fault is activated, it latches the FLAG output low and also turns the switch off. FLAG is an open-drain output transistor and requires an external pullup resistor from FLAG to IN. During shutdown (VON < VIL), the pulldown on the FLAG output is released in order to limit power dissipation. FLAG goes low when any of the following conditions occur: ●● The die temperature exceeds the thermal-shutdown temperature limit of +150°C. ●● The device is in current limit for more than the faultblanking period. ●● VIN is below the UVLO threshold. www.maximintegrated.com For the MAX4915A/MAX4917A (autoretry versions), FLAG stays low until the overcurrent condition is removed (See Figure 2). Autoretry (MAX4915A/MAX4917A) When the forward or reverse current-limit threshold is exceeded, tBLANK timer begins counting (Figure 2). The timer resets if the overcurrent condition disappears before tBLANK has elapsed. A retry time delay, tRETRY, is started immediately after tBLANK has elapsed, and during that time, the switch is latched off. At the end of tRETRY, the switch is turned on again. If the fault still exists, the cycle is repeated. If the fault has been removed, the switch stays on. Maxim Integrated │  8 MAX4914B/MAX4915A/B/ MAX4917A/B FIGURE 3a tBLANK 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current tBLANK Reset the switch by either toggling ON (Figure 3a) or cycling the input voltage below UVLO, typically 2V (Figure 3b). Fault Blanking All devices feature 14ms (min) fault blanking. Fault blanking allows current-limit faults, including momentary shortcircuit faults that occur when hot-swapping a capacitive load, and also ensures that no fault is issued during power-up. When a load transient causes the device to enter current limit, an internal counter starts. If the loadtransient fault persists beyond the fault-blanking timeout, FLAG asserts low. Load-transient faults less than tBLANK do not cause a FLAG output assertion. Only current-limit faults are blanked. LOAD CURRENT ON SWITCH STATUS OFF ON PIN VOLTAGE FLAG PIN STATUS FIGURE 3b tBLANK tBLANK Thermal Shutdown LOAD CURRENT ON SWITCH STATUS A thermal fault and input voltage drops below the UVLO threshold cause FLAG to assert immediately and not wait for the blanking time. OFF IN PIN VOLTAGE UVLO FLAG PIN STATUS Figure 3. MAX4914B/MAX4915B/MAX4917B Latchoff Fault Blanking The autoretry feature saves system power in the case of an overcurrent or short-circuit condition. During tBLANK, when the switch is on, the supply current is at the current limit. During tRETRY, when the switch is off, the current through the switch is zero. Instead of observing the full load current, the switch sees the equivalent load current times duty cycle or ISUPPLY = ILOAD x tBLANK/(tBLANK + tRETRY). With a typical tBLANK = 37ms and typical tRETRY = 555ms, the duty cycle is 6%, which results in a 94% power savings over the switch being on the entire time. The duty cycle is consistent across the process and devices. Latchoff (MAX4914B/MAX4915B/MAX4917B) When the forward or reverse current-limit threshold is exceeded, the tBLANK timer begins counting. The timer resets if the overcurrent condition disappears before tBLANK has elapsed. The switch is shut off if the overcurrent condition continues up to the end of the blanking time. www.maximintegrated.com The devices have a thermal-shutdown feature to protect the devices from overheating. The switch turns off and FLAG goes low immediately (no fault blanking) when the junction temperature exceeds +150°C. The switch turns back on when the device temperature drops approximately by 15°C. Applications Information Input Capacitor To limit the input-voltage drop during momentary output short-circuit conditions, connect a capacitor from IN to GND. A 0.1μF ceramic capacitor is adequate for most applications; however, higher capacitor values further reduce the voltage drop at the input and are recommended for lower voltage applications. Output Capacitance Connect a 0.1μF capacitor from OUT to GND. This capacitor helps prevent inductive parasitics from pulling OUT negative during turn-off, thus preventing the devices from tripping erroneously. If the load capacitance is too large, the current may not have enough time to charge the capacitance and the device assumes that there is a faulty load condition. The maximum capacitive load value that can be driven from OUT is obtained by the following formula: C MAX < IFWD_MIN × t BLANK _MIN VIN Maxim Integrated │  9 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Layout and Thermal Dissipation total power dissipated during the short is scaled by the duty cycle: To optimize the switch response time to output shortcircuit conditions, it is very important to keep all traces VIN_MAX × I OUT_MAX × t BLANK as short as possible to reduce the effect of undesirable = PMAX = 155mW t RETRY + t BLANK parasitic inductance. Place input and output capacitors as close as possible to the device (no more than 5mm). where VIN = 5.5V, IOUT = 450mA, tBLANK = 14ms, and IN and OUT pins must be connected with short traces to tRETRY = 210ms. the power bus. Attention must be given to the MAX4914B/MAX4915B/ During normal operation, the power dissipation is small MAX4917B (latchoff versions), where the latchoff condition and the package temperature change is minimal. If the must be manually reset by toggling ON from high to low. output is continuously shorted to ground at the maximum If the latchoff time duration is not sufficiently high, it is supply voltage, the operation of the switches with the possible for the device to reach the thermalshutdown autoretry option does not cause problems because the threshold and never be able to turn the device on until it cools down. Typical Operating Circuit 2.3V TO 5.5V IN ON MAX4914B FLAG MAX4915A/B MAX4917A/B OUT µP TO SDIO PORT GND www.maximintegrated.com Maxim Integrated │  10 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Ordering Information/Selector Guide PIN-PACKAGE TOP MARK CURRENT LIMIT (mA) MAX4914BELT+T PART 6 µDFN ABF 100 RETRY/LATCHOFF Latchoff MAX4915AELT+T 6 µDFN ABL 200 Autoretry MAX4915AEUK+T 5 SOT23 AEYN 200 Autoretry MAX4915BELT+T 6 µDFN ABG 200 Latchoff MAX4915BEUK+T 5 SOT23 AEYK 200 Latchoff MAX4917AELT+T 6 µDFN ABN 300 Autoretry MAX4917AEUK+T 5 SOT23 AEYP 300 Autoretry MAX4917BELT+T 6 µDFN ABI 300 Latchoff MAX4917BEUK+T 5 SOT23 AEYM 300 Latchoff Note: All devices are specified over the -40°C to +85°C operating temperature range. +Denotes a lead-free/RoHS-compliant package. T = Tape-and-reel package. Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. 6 µDFN L622-1 21-0164 5 SOT23 U5+2 21-0057 www.maximintegrated.com Chip Information PROCESS: BiCMOS Maxim Integrated │  11 MAX4914B/MAX4915A/B/ MAX4917A/B 100mA/200mA/300mA Current-Limit Switches with Low Shutdown Reverse Current Revision History REVISION NUMBER REVISION DATE 0 5/06 Initial release — 1 12/06 Removed future product notes. Added new VIH and VIL EC table specs for the MAX4915 — 2 6/08 Changed VIH and VIL EC table specs for the MAX4917A 2 3 1/16 Updated future product designations and package code DESCRIPTION PAGES CHANGED 1, 10 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. ©  2016 Maxim Integrated Products, Inc. │  12
MAX4917AEUK+TG128 价格&库存

很抱歉,暂时无法提供与“MAX4917AEUK+TG128”相匹配的价格&库存,您可以联系我们找货

免费人工找货