0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TMP01FSZ-REEL

TMP01FSZ-REEL

  • 厂商:

    AD(亚德诺)

  • 封装:

    SOIC-8_4.9X3.9MM

  • 描述:

    IC SENSOR TEMP/CONTROLLER 8SOIC

  • 数据手册
  • 价格&库存
TMP01FSZ-REEL 数据手册
Low Power Programmable Temperature Controller TMP01 FUNCTIONAL BLOCK DIAGRAM FEATURES VREF 1 R1 2.5V TEMPERATURE SENSOR AND SENSOR VOLTAGE REFERENCE SET 2 HIGH R2 SET 3 LOW 7 OVER WINDOW COMPARATOR 6 UNDER R3 GND 4 5 VPTAT HYSTERESIS GENERATOR TMP01 APPLICATIONS 8 V+ 00333-001 −55°C to +125°C (−67°F to +257°F) operation ±1.0°C accuracy over temperature (typ) Temperature-proportional voltage output User-programmable temperature trip points User-programmable hysteresis 20 mA open-collector trip point outputs TTL/CMOS compatible Single-supply operation (4.5 V to 13.2 V) PDIP, SOIC, and TO-99 packages Figure 1. Over/under temperature sensor and alarm Board-level temperature sensing Temperature controllers Electronic thermostats Thermal protection HVAC systems Industrial process control Remote sensors GENERAL DESCRIPTION The TMP01 is a temperature sensor that generates a voltage output proportional to absolute temperature and a control signal from one of two outputs when the device is either above or below a specific temperature range. Both the high/low temperature trip points and hysteresis (overshoot) band are determined by user-selected external resistors. For high volume production, these resistors are available on board. Hysteresis is also programmed by the external resistor chain and is determined by the total current drawn out of the 2.5 V reference. This current is mirrored and used to generate a hysteresis offset voltage of the appropriate polarity after a comparator has been tripped. The comparators are connected in parallel, which guarantees that there is no hysteresis overlap and eliminates erratic transitions between adjacent trip zones. The TMP01 consists of a band gap voltage reference combined with a pair of matched comparators. The reference provides both a constant 2.5 V output and a voltage proportional to absolute temperature (VPTAT) which has a precise temperature coefficient of 5 mV/K and is 1.49 V (nominal) at 25°C. The comparators compare VPTAT with the externally set temperature trip points and generate an open-collector output signal when one of their respective thresholds has been exceeded. The TMP01 utilizes proprietary thin-film resistors in conjunction with production laser trimming to maintain a temperature accuracy of ±1°C (typical) over the rated temperature range, with excellent linearity. The open-collector outputs are capable of sinking 20 mA, enabling the TMP01 to drive control relays directly. Operating from a 5 V supply, quiescent current is only 500 μA (max). The TMP01 is available in 8-pin mini PDIP, SOIC, and TO-99 packages. Rev. E Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 ©1993–2009 Analog Devices, Inc. All rights reserved. TMP01 TABLE OF CONTENTS Features .............................................................................................. 1  Self-Heating Effects .................................................................... 10  Applications ....................................................................................... 1  Buffering the Voltage Reference ............................................... 10  Functional Block Diagram .............................................................. 1  General Description ......................................................................... 1  Preserving Accuracy Over Wide Temperature Range Operation .................................................................................... 10  Revision History ............................................................................... 2  Thermal Response Time ........................................................... 10  Specifications..................................................................................... 3  Switching Loads with the Open-Collector Outputs .............. 11  TMP01EST, TMP01FP, TMP01FS ............................................. 3  High Current Switching ............................................................ 12  TMP01FJ........................................................................................ 4  Buffering the Temperature Output Pin ................................... 13  Absolute Maximum Ratings............................................................ 5  Differential Transmitter............................................................. 13  Typical Performance Characteristics ............................................. 6  4 mA to 20 mA Current Loop .................................................. 13  Theory of Operation ........................................................................ 8  Temperature-to-Frequency Converter .................................... 14  Temperature Hysteresis ............................................................... 8  Isolation Amplifier ..................................................................... 15  Programming the TMP01 ........................................................... 8  Out-of-Range Warning.............................................................. 15  Understanding Error Sources ..................................................... 9  Translating 5 mV/K to 10 mV/°C ............................................ 16  Translating VPTAT to the Fahrenheit Scale ........................... 16  Safety Considerations in Heating and Cooling System Design ............................................................................................ 9  Outline Dimensions ....................................................................... 17  Applications Information .............................................................. 10  Ordering Guide .......................................................................... 18  REVISION HISTORY 7/09—Rev. D to Rev. E Updated Format .................................................................. Universal Updated Outline Dimensions ....................................................... 18 Changes to Ordering Guide .......................................................... 19 1/02—Rev. C: Rev. D Edits to General Descriptions Section ........................................... 1 Edits to Specifications Section ........................................................ 2 Edits to Wafer Test Limits Section.................................................. 4 Edits to Dice Characteristics Section ............................................. 4 Edits to Ordering Guide .................................................................. 5 7/93—Revision 0: Initial Version Rev. E | Page 2 of 20 TMP01 SPECIFICATIONS TMP01ES, TMP01FP, TMP01FS PDIP and SOIC packages. V+ = 5 V, GND = O V, −40°C ≤ TA ≤ +85°C, unless otherwise noted. Table 1. Parameter INPUTS SET HIGH, SET LOW Offset Voltage Offset Voltage Drift Input Bias Current, E Grade Input Bias Current, F Grade OUTPUT VPTAT Output Voltage Scale Factor 1 Temperature Accuracy, E Grade Temperature Accuracy, F Grade Temperature Accuracy, E Grade Temperature Accuracy, F Grade Temperature Accuracy, E Grade Temperature Accuracy, F Grade Temperature Accuracy, E Grade Temperature Accuracy, F Grade Repeatability Error 2 Long-Term Drift Error 3,4 Power Supply Rejection Ratio OUTPUT VREF Output Voltage, E Grade Output Voltage, F Grade Output Voltage, E Grade Output Voltage, F Grade Output Voltage, E Grade Output Voltage, F Grade Drift Line Regulation Load Regulation Output Current, Zero Hysteresis Hysteresis Current Scale Factor1 Turn-On Settling Time OPEN-COLLECTOR OUTPUTS OVER, UNDER Output Low Voltage Output Leakage Current Fall Time POWER SUPPLY Supply Range Supply Current Power Dissipation Symbol Conditions Min VOS TCVOS IB IB VPTAT TCVPTAT Typ 0.25 3 25 25 TA = 25°C, no load ΔVPTAT TA = 25°C, no load TA = 25°C, no load 10°C < TA < 40°C, no load 10°C < TA < 40°C, no load −40°C < TA < 85°C, no load −40°C < TA < 85°C, no load −55°C < TA < 125°C, no load −55°C < TA < 125°C, no load PSRR TA = 25°C, 4.5 V ≤ V+ ≤ 13.2 V VREF VREF VREF VREF VREF VREF TCVREF TA = 25°C, no load TA = 25°C, no load −40°C < TA < 85°C, no load −40°C < TA < 85°C, no load −55°C < TA < 125°C, no load −55°C < TA < 125°C, no load −1.5 −3 −3.0 −5.0 2.495 2.490 2.490 2.485 1.49 5 ±0.5 ±1.0 ±0.75 ±1.5 ±1 ±2 ±1.5 ±2.5 0.25 0.25 ±0.02 To rated accuracy 2.500 2.500 2.500 2.500 2.5 ± 0.01 2.5 ± 0.015 −10 ±0.01 ±0.1 7 5.0 25 VOL VOL IOH tHL ISINK = 1.6 mA ISINK = 20 mA V+ = 12 V See Figure 2 0.25 0.6 1 40 V+ ISY ISY PDISS Unloaded, +V = 5 V Unloaded, +V = 13.2 V +V = 5 V 4.5 V ≤ V+ ≤ 13.2 V 10 μA ≤ IVREF ≤ 500 μA IVREF SFHYS 4.5 1 K = °C + 273.15. Maximum deviation between 25°C readings after temperature cycling between −55°C and +125°C. 3 Guaranteed but not tested. 4 Observed in a group sample over an accelerated life test of 500 hours at 150°C. 2 Rev. E | Page 3 of 20 400 450 2.0 Max Unit 50 100 mV μV/°C nA nA 1.5 3 3.0 5.0 0.5 ±0.1 2.505 2.510 2.510 2.515 ±0.05 ±0.25 0.4 100 13.2 500 800 2.5 V mV/K °C °C °C °C °C °C °C °C Degree Degree %/V V V V V V V ppm/°C %/V %/mA μA μA/°C μs V V μA ns V μA μA mW TMP01 V+ 20pF 00333-002 1kΩ Figure 2. Test Load TMP01FJ TO-99 metal can package. V+ = 5 V, GND = 0 V, −40°C ≤ TA ≤ +85°C, unless otherwise noted. Table 2. Parameter INPUTS SET HIGH, SET LOW Offset Voltage Offset Voltage Drift Input Bias Current, F Grade OUTPUT VPTAT Output Voltage Scale Factor1 Temperature Accuracy, F Grade Temperature Accuracy, F Grade Temperature Accuracy, F Grade Temperature Accuracy, F Grade Repeatability Error2 Long-Term Drift Error3, 4 Power Supply Rejection Ratio OUTPUT VREF Output Voltage, F Grade Output Voltage, F Grade Output Voltage, F Grade Drift Line Regulation Load Regulation Output Current, Zero Hysteresis Hysteresis Current Scale Factor1 Turn-On Settling Time OPEN-COLLECTOR OUTPUTS OVER, UNDER Output Low Voltage Output Leakage Current Fall Time POWER SUPPLY Supply Range Supply Current Power Dissipation Symbol Conditions Min VOS TCVOS IB VPTAT TCVPTAT Typ 0.25 3 25 TA = 25°C, no load ΔVPTAT TA = 25°C, no load 10°C < TA < 40°C, no load −40°C < TA < 85°C, no load −55°C < TA < 125°C, no load PSRR TA = 25°C, 4.5 V ≤ V+ ≤ 13.2 V VREF VREF VREF TCVREF TA = 25°C, no load −40°C < TA < 85°C, no load −55°C < TA < 125°C, no load −3 −5.0 2.490 2.485 1.49 5 ±1.0 ±1.5 ±2 ±2.5 0.25 0.25 ±0.02 To rated accuracy 2.500 2.500 2.5 ± 0.015 −10 ±0.01 ±0.1 7 5.0 25 VOL VOL IOH tHL ISINK = 1.6 mA ISINK = 20 mA V+ = 12 V See Figure 2 0.25 0.6 1 40 V+ ISY ISY PDISS Unloaded, +V = 5 V Unloaded, +V = 13.2 V +V = 5 V 4.5 V ≤ V+ ≤ 13.2 V 10 μA ≤ IVREF ≤ 500 μA IVREF SFHYS 4.5 1 K = °C + 273.15. Maximum deviation between 25°C readings after temperature cycling between −55°C and +125°C. 3 Guaranteed but not tested. 4 Observed in a group sample over an accelerated life test of 500 hours at 150°C. 2 Rev. E | Page 4 of 20 400 450 2.0 Max Unit 100 mV μV/°C nA 3 5.0 0.5 ±0.1 2.510 2.515 ±0.05 ±0.25 0.4 100 13.2 500 800 2.5 V mV/K °C °C °C °C Degree Degree %/V V V V ppm/°C %/V %/mA μA μA/°C μs V V μA ns V μA μA mW TMP01 ABSOLUTE MAXIMUM RATINGS Table 3. Parameter Maximum Supply Voltage Maximum Input Voltage (SET HIGH, SET LOW) Maximum Output Current (VREF, VPTAT) Maximum Output Current (Open-Collector Outputs) Maximum Output Voltage (Open-Collector Outputs) Operating Temperature Range Die Junction Temperature Storage Temperature Range Lead Temperature (Soldering 60 sec) Rating −0.3 V to +15 V −0.3 V to V+ +0.3 V 2 mA 50 mA 15 V Digital inputs and outputs are protected; however, permanent damage may occur on unprotected units from high energy electrostatic fields. Keep units in conductive foam or packaging at all times until ready to use. Use proper antistatic handling procedures. Remove power before inserting or removing units from their sockets. Table 4. −55°C to +150°C 150°C −65°C to +150°C 300°C Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Package Type 8-Lead PDIP (N-8) 8-Lead SOIC (R-8) 8-Pin TO-99 Can (H-08) 1 2 θJA 103 1 158 2 1501 θJC 43 43 18 θJA is specified for device in socket (worst-case conditions). θJA is specified for device mounted on PCB. ESD CAUTION Rev. E | Page 5 of 20 Unit °C/W °C/W °C/W TMP01 TYPICAL PERFORMANCE CHARACTERISTICS 550 2.508 V+ = 5V 525 500 2.504 475 VREF (V) SUPPLY CURRENT (µA) 2.506 +125°C 450 +85°C 2.502 425 –55°C 2.500 400 +25°C 2.498 375 5 10 SUPPLY VOLTAGE (V) 15 20 2.496 –75 00333-003 0 –25 0 25 50 TEMPERATURE (°C) 75 100 125 Figure 6. VREF Accuracy vs. Temperature Figure 3. Supply Current vs. Supply Voltage 6 5.0 5 VC = 15V V+ = 5V TA = 25°C 4.5 VCE (V) 4 4.0 3 2 3.5 3.0 –75 –50 –25 0 25 50 TEMPERATURE (°C) 75 100 125 0 0 10 20 30 40 50 IC (mA) 00333-007 1 00333-004 MINIMUM SUPPLY VOLTAGE (V) –50 00333-006 –40°C 350 Figure 7. Open-Collector Output (OVER, UNDER) Saturation Voltage vs. Output Current Figure 4. Minimum Supply Voltage vs. Temperature 2.0 2.510 V+ = 5V 1.5 2.508 VREF (V) 0.5 0 –0.5 –1.0 2.502 2.500 X 2.498 2.496 2.494 X – 3σ 2.492 –50 –25 0 25 50 TEMPERATURE (°C) 75 100 125 2.490 Figure 5. VPTAT Accuracy vs. Temperature 0 200 400 600 800 T = HOURS OF OPERATION AT 125°C; V+ = 5V Figure 8. VREF Long Term Drift Accelerated by Burn-In Rev. E | Page 6 of 20 1000 00333-008 –1.5 –2.0 –75 X + 3σ 2.506 CURVES NOT NORMALIZED EXTRAPOLATED FROM OPERATING LIFE DATA 2.504 00333-005 VPTAT ERROR (°C) 1.0 TMP01 100 8 V+ = 5V TA = 25°C IVREF = 5µA 7 80 NUMBER OF DEVICES 6 PSRR (dB) 60 V+ = 5V IVREF = 10µA 40 20 5 4 3 2 0 1k 10k FREQUENCY (Hz) 100k 0 –0.4 00333-009 –20 100 1M –0.32 –0.24 –0.16 –0.08 OFFSET (mV) 0 0.08 00333-011 1 0.16 Figure 11. Comparator Input Offset Distribution Figure 9. VREF Power Supply Rejection vs. Frequency 10 1.0 9 V+ = 5V TA = 25°C NUMBER OF DEVICES 0.1 6 5 4 3 2 V+ = 5V IVREF = 7.5µA 1 00333-010 0.01 7 0 6.2 6.4 6.6 7 7.2 7.4 7.6 6.8 REFERENCE CURRENT (µA) 7.8 Figure 12. Zero Hysteresis Current Distribution Figure 10. Set High, Set Low Input Offset Voltage vs. Temperature Rev. E | Page 7 of 20 8 00333-012 OFFSET VOLTAGE (mV) 8 TMP01 THEORY OF OPERATION HYSTERESIS LOW HI HYSTERESIS CURRENT 8 V+ 7 OVER 6 UNDER 5 VPTAT WINDOW COMPARATOR VOLTAGE REFERENCE AND SENSOR 1kΩ TSETHIGH Figure 14. TMP01 Hysteresis Profile After a temperature setpoint is exceeded and a comparator tripped, the buffer output is enabled. The output is a current of the appropriate polarity that generates a hysteresis offset voltage across an internal 1000 Ω resistor at the comparator input. The comparator output remains on until the voltage at the comparator input, now equal to the temperature sensor voltage VPTAT summed with the hysteresis offset, returns to the programmed setpoint voltage. The comparator then returns low, deactivating the open-collector output and disabling the hysteresis current buffer output. The scale factor for the programmed hysteresis current is: Thus, since VREF = 2.5 V, with a reference load resistance of 357 kΩ or greater (output current 7 μA or less), the temperature setpoint hysteresis is zero degrees. Larger values of load resistance only decrease the output current below 7 μA and have no effect on the operation of the device. The amount of hysteresis is determined by selecting a value of load resistance for VREF. IHYS PROGRAMMING THE TMP01 HYSTERESIS VOLTAGE TEMPERATURE OUTPUT TMP01 00333-013 GND 4 TEMPERATURE TSETLOW IHYS = IVREF = 5 μA/°C + 7 μA SET 2 HIGH SET 3 LOW LO ENABLE VREF 1 CURRENT MIRROR HYSTERESIS HIGH = HYSTERESIS LOW OUTPUT VOLTAGE OVER, UNDER The temperature sensor is basically a very accurate, temperature compensated, band gap-type voltage reference with a buffered output voltage proportional to absolute temperature (VPTAT), accurately trimmed to a scale factor of 5 mV/K. The low drift 2.5 V reference output VREF is easily divided externally with fixed resistors or potentiometers to accurately establish the programmed heat/cool setpoints, independent of temperature. Alternatively, the setpoint voltages can be supplied by other ground referenced voltage sources such as userprogrammed DACs or controllers. The high and low setpoint voltages are compared to the temperature sensor voltage, thus creating a two-temperature thermostat function. In addition, the total output current of the reference (IVREF) determines the magnitude of the temperature hysteresis band. The open collector outputs of the comparators can be used to control a wide variety of devices. HYSTERESIS HIGH 00333-014 The TMP01 is a linear voltage-output temperature sensor, with a window comparator that can be programmed by the user to activate one of two open-collector outputs when a predetermined temperature setpoint voltage has been exceeded. A low drift voltage reference is available for setpoint programming. Figure 13. Detailed Block Diagram TEMPERATURE HYSTERESIS The temperature hysteresis is the number of degrees beyond the original setpoint temperature that must be sensed by the TMP01 before the setpoint comparator is reset and the output disabled. Figure 14 shows the hysteresis profile. The hysteresis is programmed by the user by setting a specific load on the reference voltage output VREF. This output current IVREF is also called the hysteresis current, which is mirrored internally and fed to a buffer with an analog switch. In the basic fixed setpoint application utilizing a simple resistor ladder voltage divider, the desired temperature setpoints are programmed in the following sequence: 1. 2. 3. 4. Rev. E | Page 8 of 20 Select the desired hysteresis temperature. Calculate the hysteresis current IVREF. Select the desired setpoint temperatures. Calculate the individual resistor divider ladder values needed to develop the desired comparator setpoint voltages at SET HIGH and SET LOW. TMP01 The hysteresis current is readily calculated. For example, for 2 degrees of hysteresis, IVREF = 17 μA. Next, the setpoint voltages, VSETHIGH and VSETLOW, are determined using the VPTAT scale factor of 5 mV/K = 5 mV/(°C + 273.15), which is 1.49 V for 25°C. Then, calculate the divider resistors, based on those setpoints. The equations used to calculate the resistors are VSETHIGH = (TSETHIGH + 273.15) (5 mV/°C) VSETLOW = (TSETLOW + 273.15) (5 mV/°C) R1 (kΩ) = (VVREF − VSETHIGH)/IVREF = (2.5 V − VSETHIGH)/IVREF R2 (kΩ) = (VSETHIGH − VSETLOW)/IVREF R3 (kΩ) = VSETLOW/IVREF 1 VVREF = 2.5V 8 V+ IVREF (VVREF – VSETHIGH)/IVREF = R1 2 VSETHIGH TMP01 VSETLOW 3 6 UNDER 4 5 VPTAT 00333-015 VSETLOW /IVREF = R3 GND Figure 15. TMP01 Setpoint Programming The total R1 + R2 + R3 is equal to the load resistance needed to draw the desired hysteresis current from the reference, or IVREF. The formulas shown above are also helpful in understanding the calculation of temperature setpoint voltages in circuits other than the standard two-temperature thermostat. If a setpoint function is not needed, the appropriate comparator should be disabled. SET HIGH can be disabled by tying it to V+, SET LOW by tying it to GND. Either output can be left unconnected. 218 248 –55 –25 –18 273 298 323 348 373 398 0 25 50 75 100 125 32 50 77 100 K °C –67 –25 0 150 200 212 The thermal mass of the TMP01 package and the degree of thermal coupling to the surrounding circuitry are the largest factors in determining the rate of thermal settling, which ultimately determines the rate at which the desired temperature measurement accuracy may be reached. Thus, allow sufficient time for the device to reach the final temperature. The typical thermal time constant for the plastic package is approximately 140 seconds in still air. Therefore, to reach the final temperature accuracy within 1%, for a temperature change of 60 degrees, a settling time of 5 time constants, or 12 minutes, is necessary. The setpoint comparator input offset voltage and zero hysteresis current affect setpoint error. While the 7 μA zero hysteresis current allows the user to program the TMP01 with moderate resistor divider values, it does vary somewhat from device to device, causing slight variations in the actual hysteresis obtained in practice. Comparator input offset directly impacts the programmed setpoint voltage and thus the resulting hysteresis band, and must be included in error calculations. 7 OVER (VSETHIGH – VSETLOW)/IVREF = R2 resistor divider ratios. The comparator input bias current (inputs SET HIGH, SET LOW) drops to less than 1 nA (typ) when the comparator is tripped. This can account for some setpoint voltage error, equal to the change in bias current times the effective setpoint divider ladder resistance to ground. 257 External error sources to consider are the accuracy of the programming resistors, grounding error voltages, and the overall problem of thermal gradients. The accuracy of the external programming resistors directly impacts the resulting setpoint accuracy. Thus, in fixed-temperature applications, the user should select resistor tolerances appropriate to the desired programming accuracy. Resistor temperature drift must be taken into account also. This effect can be minimized by selecting good quality components, and by keeping all components in close thermal proximity. Applications requiring high measurement accuracy require great attention to detail regarding thermal gradients. Careful circuit board layout, component placement, and protection from stray air currents are necessary to minimize common thermal error sources. 1.09 1.24 1.365 1.49 1.615 1.74 VPTAT 1.865 1.99 00333-016 °F Figure 16. Temperature—VPTAT Scale UNDERSTANDING ERROR SOURCES The accuracy of the VPTAT sensor output is well characterized and specified; however, preserving this accuracy in a heating or cooling control system requires some attention to minimizing the various potential error sources. The internal sources of setpoint programming error include the initial tolerances and temperature drifts of the reference voltage VREF, the setpoint comparator input offset voltage and bias current, and the hysteresis current scale factor. When evaluating setpoint programming errors, remember that any VREF error contribution at the comparator inputs is reduced by the Also, the user should take care to keep the bottom of the setpoint programming divider ladder as close to GND (Pin 4) as possible to minimize errors due to IR voltage drops and coupling of external noise sources. In any case, a 0.1 μF capacitor for power supply bypassing is always recommended at the chip. SAFETY CONSIDERATIONS IN HEATING AND COOLING SYSTEM DESIGN Designers should anticipate potential system fault conditions, which may result in significant safety hazards, which are outside the control of and cannot be corrected by the TMP01-based circuit. Observe governmental and industrial regulations regarding safety requirements and standards for such designs where applicable. Rev. E | Page 9 of 20 TMP01 APPLICATIONS INFORMATION SELF-HEATING EFFECTS In some applications, the user should consider the effects of self-heating due to the power dissipated by the open-collector outputs, which are capable of sinking 20 mA continuously. Under full load, the TMP01 open-collector output device is dissipating PDISS = 0.6 V × .020A = 12 mW which in a surface-mount SOIC package accounts for a temperature increase due to self-heating of ΔT = PDISS × θJA = .012 W × 158°C/W = 1.9°C This self-heating effect directly affects the accuracy of the TMP01 and will, for example, cause the device to activate the OVER output 2 degrees early. Bonding the package to a moderate heat sink limits the selfheating effect to approximately: ΔT = PDISS × θJC = .012 W × 43°C/W = 0.52°C which is a much more tolerable error in most systems. The VREF and VPTAT outputs are also capable of delivering sufficient current to contribute heating effects and should not be ignored. BUFFERING THE VOLTAGE REFERENCE The reference output VREF is used to generate the temperature setpoint programming voltages for the TMP01 and also to determine the hysteresis temperature band by the reference load current IVREF. The on-board output buffer amplifier is typically capable of 500 μA output drive into as much as 50 pF load (maximum). Exceeding this load affects the accuracy of the reference voltage, could cause thermal sensing errors due to dissipation, and may induce oscillations. Selection of a low drift buffer functioning as a voltage follower with high input impedance ensures optimal reference accuracy, and does not affect the programmed hysteresis current. Amplifiers which offer the low drift, low power consumption, and low cost appropriate to this application include the OP295, and members of the OP90, OP97, OP177 families, and others as shown in the following applications circuits. PRESERVING ACCURACY OVER WIDE TEMPERATURE RANGE OPERATION The TMP01 is unique in offering both a wide range temperature sensor and the associated detection circuitry needed to implement a complete thermostatic control function in one monolithic device. While the voltage reference, setpoint comparators, and output buffer amplifiers have been carefully compensated to maintain accuracy over the specified temperature range, the user has an additional task in maintaining the accuracy over wide operating temperature ranges in the application. Since the TMP01 is both sensor and control circuit, in many applications it is possible that the external components used to program and interface the device may be subjected to the same temperature extremes. Thus, it may be necessary to locate components in close thermal proximity to minimize large temperature differentials, and to account for thermal drift errors, such as resistor matching tempcos, amplifier error drift, and the like, where appropriate. Circuit design with the TMP01 requires a slightly different perspective regarding the thermal behavior of electronic components. THERMAL RESPONSE TIME The time required for a temperature sensor to settle to a specified accuracy is a function of the thermal mass of the sensor, and the thermal conductivity between the sensor and the object being sensed. Thermal mass is often considered equivalent to capacitance. Thermal conductivity is commonly specified using the symbol Q, and can be thought of as the reciprocal of thermal resistance. It is commonly specified in units of degrees per watt of power transferred across the thermal joint. Thus, the time required for the TMP01 to settle to the desired accuracy is dependent on the package selected, the thermal contact established in that particular application, and the equivalent power of the heat source. In most applications, the settling time is probably best determined empirically. With excellent drift and noise characteristics, VREF offers a good voltage reference for data acquisition and transducer excitation applications as well. Output drift is typically better than −10 ppm/°C, with 315 nV/√Hz (typ) noise spectral density at 1 kHz. Rev. E | Page 10 of 20 TMP01 SWITCHING LOADS WITH THE OPEN-COLLECTOR OUTPUTS In many temperature sensing and control applications, some type of switching is required. Whether it be to turn on a heater when the temperature goes below a minimum value or to turn off a motor that is overheating, the open-collector outputs OVER and UNDER can be used. For the majority of applications, the switches used need to handle large currents on the order of 1 A and above. Because the TMP01 is accurately measuring temperature, the open-collector outputs should handle less than 20 mA of current to minimize self-heating. Figure 19 shows a similar circuit for turning on an n-channel MOSFET, except that now the gate to source voltage is positive. For this reason, an external transistor must be used as an inverter so that the MOSFET turns on when the UNDER output pulls down. 1 R1 HEATING ELEMENT 6 4 5 00333-018 TMP01 Figure 18. Driving a P-Channel MOSFET 1 VREF R1 TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE 2 MOTOR SHUTDOWN V+ 8 4.7kΩ 4.7kΩ HEATING ELEMENT 7 NC WINDOW COMPARATOR R2 IRF130 3 2N1711 6 R3 4 2604-12-311 COTO 3 5 NC HYSTERESIS GENERATOR NC = NO CONNECT 7 WINDOW COMPARATOR R2 6 5 NC HYSTERESIS GENERATOR TMP01 00333-019 2 IN4001 OR EQUIV. IRFR9024 + OR EQUIV. NC = NO CONNECT R3 TMP01 Figure 19. Driving an N-Channel MOSFET 00333-017 HYSTERESIS GENERATOR Figure 17. Reed Relay Drive It is important to check the particular relay to ensure that the current needed to activate the coil does not exceed the TMP01’s recommended output current of 20 mA. This is easily determined by dividing the relay coil voltage by the specified coil resistance. Keep in mind that the inductance of the relay creates large voltage spikes that can damage the TMP01 output unless protected by a commutation diode across the coil, as shown. The relay shown has a contact rating of 10 W maximum. If a relay capable of handling more power is desired, the larger contacts probably require a commensurately larger coil, with lower coil resistance and thus higher trigger current. As the contact power handling capability increases, so does the current needed for the coil. In some cases, an external driving transistor should be used to remove the current load on the TMP01. Isolated gate bipolar transistors (IGBT) combine many of the benefits of power MOSFETs with bipolar transistors, and are used for a variety of high power applications. Because IGBTs have a gate similar to MOSFETs, turning on and off the devices is relatively simple as shown in Figure 20. The turn-on voltage for the IGBT shown (IRGBC40S) is between 3.0 V and 5.5 V. This part has a continuous collector current rating of 50 A and a maximum collector-to-emitter voltage of 600 V, enabling it to work in very demanding applications. 1 R1 VREF TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE 2 V+ 8 4.7kΩ 4.7kΩ 7 NC WINDOW COMPARATOR R2 MOTOR CONTROL IRGBC40S 3 6 2N1711 R3 Power FETs are popular for handling a variety of high current dc loads. Figure 18 shows the TMP01 driving a p-channel MOSFET transistor for a simple heater circuit. When the output transistor turns on, the gate of the MOSFET is pulled down to approximately 0.6 V, turning it on. For most MOSFETs, a gate-to-source voltage, or Vgs, on the order of −2 V to −5 V is sufficient to turn the device on. Rev. E | Page 11 of 20 4 5 NC HYSTERESIS GENERATOR TMP01 NC = NO CONNECT Figure 20. Driving an IGBT 00333-020 R1 8 7 NC 2.4kΩ (12V) 1.2kΩ (6V) 5% WINDOW COMPARATOR 3 12V 1 V+ 8 2 R2 4 Figure 17 through Figure 21 show a variety of circuits where the TMP01 controls a switch. The main consideration in these circuits, such as the relay in Figure 17, is the current required to activate the switch. TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE R3 The OVER and UNDER outputs should not drive the equipment directly. Instead, an external switching device is required to handle the large currents. Some examples of these are relays, power MOSFETs, thyristors, IGBTs, and Darlingtons. VREF VREF TMP01 The last class of high power devices discussed here are thyristors, which includes SCRs and Triacs. Triacs are a useful alternative to relays for switching ac line voltages. The 2N6073A shown in Figure 21 is rated to handle 4A (rms). The optoisolated MOC3011 Triac features excellent electrical isolation from the noisy ac line and complete control over the high power Triac with only a few additional components. Thus, the output taken from the collector of Q2 is identical to the output of the TMP01. By picking a transistor that can accommodate large amounts of current, many high power devices can be switched. 1 VREF R1 TEMPERATURE SENSOR AND VOLTAGE REFERENCE AC 2 3 7 NC 3 2 6 MOC9011 3 R3 4 5 4 5 HYSTERESIS GENERATOR TMP01 2N6073A 4 5 NC HYSTERESIS GENERATOR Figure 22. An External Resistor Minimizes Self-Heating 00333-021 TMP01 NC = NO CONNECT 1 Figure 21. Controlling the 2N6073A Triac VREF R1 HIGH CURRENT SWITCHING TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE 2 V+ 8 4.7kΩ 2N1711 WINDOW COMPARATOR 3 Q1 6 4 5 HYSTERESIS GENERATOR TMP01 Figure 23. Second Transistor Maintains Polarity of TMP01 Output An example of a higher power transistor is a standard Darlington configuration as shown in Figure 24. The part chosen, TIP-110, can handle 2 A continuous which is more than enough to control many high power relays. In fact, the Darlington itself can be used as the switch, similar to MOSFETs and IGBTs. RELAY MOTOR SWITCH R1 TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE 2 IC 8 V+ TIP-110 4.7kΩ 7 4.7kΩ 2N1711 WINDOW COMPARATOR R2 3 6 R3 5 HYSTERESIS GENERATOR 00333-024 4 Q2 R3 12V VREF IC 4.7kΩ 2N1711 7 R2 Internal dissipation due to large loads on the TMP01 outputs causes some temperature error due to self-heating. External transistors remove the load from the TMP01, so that virtually no power is dissipated in the internal transistors and no selfheating occurs. Figure 22 through Figure 24 show a few examples using external transistors. The simplest case, using a single transistor on the output to invert the output signal is shown in Figure 22. When the open collector of the TMP01 turns on and pulls the output down, the external transistor Q1 base is pulled low, turning off the transistor. Another transistor can be added to reinvert the signal as shown in Figure 23. Now, when the output of the TMP01 is pulled down, the first transistor, Q1, turns off and its collector goes high, which turns Q2 on, pulling its collector low. 1 Q1 6 R3 6 150Ω 1 WINDOW COMPARATOR R2 WINDOW COMPARATOR R2 LOAD 300Ω 2N1711 7 V+ = 5V 8 IC 4.7kΩ 2 VPTAT V+ 00333-023 R1 VREF 8 00333-022 1 TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE TMP01 Figure 24. Darlington Transistor Can Handle Large Currents Rev. E | Page 12 of 20 TMP01 V+ 1 The VPTAT sensor output is a low impedance dc output voltage with a 5 mV/K temperature coefficient, that is useful in multiple measurement and control applications. In many applications, this voltage needs to be transmitted to a central location for processing. The buffered VPTAT voltage output is capable of 500 μA drive into 50 pF (maximum). R1 VREF TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE 2 8 10kΩ 7 0.1µF WINDOW COMPARATOR R2 3 6 4 5 V+ 100Ω R3 Consider external amplifiers for interfacing VPTAT to external circuitry to ensure accuracy, and to minimize loading which could create dissipation-induced temperature sensing errors. An excellent general-purpose buffer circuit using the OP177 is shown in Figure 25. It is capable of driving over 10 mA, and remains stable under capacitive loads of up to 0.1 μF. Other interfacing ideas are also provided in this section. HYSTERESIS GENERATOR OP177 V– TMP01 4 mA TO 20 mA CURRENT LOOP Another common method of transmitting a signal over long distances is to use a 4 mA to 20 mA loop, as shown in Figure 27. An advantage of using a 4 mA to 20 mA loop is that the accuracy of a current loop is not compromised by voltage drops across the line. One requirement of 4 mA to 20 mA circuits is that the remote end must receive all of its power from the loop, meaning that the circuit must consume less than 4 mA. In noisy industrial environments, it is difficult to send an accurate analog signal over a significant distance. However, by sending the signal differentially on a wire pair, these errors can be significantly reduced. Because the noise is picked up equally on both wires, a receiver with high common-mode input rejection can be used to cancel out the noise very effectively at the receiving end. Figure 26 shows two amplifiers used to send the signal differentially, and an excellent differential receiver, the AMP03, which features a common-mode rejection ratio of 95 dB at dc and very low input and drift errors. Operating from 5 V, the quiescent current of the TMP01 is 500 μA maximum, and the OP90s is 20 μA maximum, totaling less than 4 mA. Although not shown, the open collector outputs and temperature setting pins can be connected to do any local control of switching. V+ 1 R1 2 8 7 WINDOW COMPARATOR R2 10kΩ 3 6 4 5 50Ω R3 10kΩ TMP01 V+ 1/2 OP297 10kΩ VOUT 50Ω AMP03 V– 1/2 OP297 Figure 26. Send the Signal Differentially for Noise Immunity Rev. E | Page 13 of 20 00333-026 HYSTERESIS GENERATOR VPTAT CL Figure 25. Buffer VPTAT to Handle Difficult Loads DIFFERENTIAL TRANSMITTER TEMPERATURE VREF SENSOR AND VPTAT VOLTAGE REFERENCE VOUT VPTAT 00333-025 BUFFERING THE TEMPERATURE OUTPUT PIN TMP01 values are shown in the circuit. The OP90 is chosen for this circuit because of its ability to operate on a single supply and its high accuracy. For initial accuracy, a 10 kΩ trim potentiometer can be included in series with R3, and the value of R3 lowered to 95 kΩ. The potentiometer should be adjusted to produce an output current of 12.3 mA at 25°C. The current is proportional to the voltage on the VPTAT output, and is calibrated to 4 mA at a temperature of −40°C, to 20 mA for +85°C. The main equation governing the operation of this circuit gives the current as a function of VPTAT 1 ⎛ VPTAT × R5 VREF × R3 ⎛ R5 ⎞ ⎞ − ⎜ ⎜1 + ⎟⎟ R6 ⎝ R2 R3 + R1 ⎝ R2 ⎠ ⎠ TEMPERATURE-TO-FREQUENCY CONVERTER The resulting temperature coefficient of the output current is 128 μA/°C. 1 V+ VREF 8 Another common method of transmitting analog information is to convert a voltage to the frequency domain. This is easily done with any of the low cost monolithic voltage-to-frequency converters (VFCs) available, which feature a robust, opencollector digital output. A digital signal is immune to noise and voltage drops because the only important information is the frequency. As long as the conversions between temperature and frequency are done accurately, the temperature data can be successfully transmitted. 5V TO 13.2V TMP01 4 GND VPTAT 5 R1 243kΩ R3 100kΩ 7 OP90 3 2N1711 6 A simple circuit to do this combines the TMP01 with an AD654 VFC, as shown in Figure 28. The AD654 outputs a square wave that is proportional to the dc input voltage according to the following equation: 4 R6 100Ω 4–20mA R5 100kΩ RL FOUT = 00333-027 2 R2 39.2kΩ VIN 10 (R1 + R2)CT By simply connecting the VPTAT output to the input of the AD654, the 5 mV/°C temperature coefficient gives a sensitivity of 25 Hz/°C, centered around 7.5 kHz at 25°C. The trimming resistor R2 is needed to calibrate the absolute accuracy of the AD654. For more information on that part, consult the AD654 data sheet. Finally, the AD650 can be used to accurately convert the frequency back to a dc voltage on the receiving end. Figure 27. 4mA to 20 mA Current Loop To determine the resistor values in this circuit, first note that VREF remains constant over temperature. Thus, the ratio of R5 over R2 must give a variation of IOUT from 4 mA to 20 mA as VPTAT varies from 1.165 V at −40°C to 1.79 V at +85°C. The absolute value of the resistors is not important, only the ratio. For convenience, 100 kΩ is chosen for R5. Once R2 is calculated, the value of R3 and R1 is determined by substituting 4 mA for IOUT and 1.165 V for VPTAT and solving. The final V+ 1 R1 TEMPERATURE VREF SENSOR AND VPTAT VOLTAGE REFERENCE 2 8 7 V+ WINDOW COMPARATOR R2 V+ 3 6 R3 8 VPTAT 4 CT 0.1µF TMP01 5kΩ 7 1 AD654 4 5 HYSTERESIS GENERATOR 6 FOUT OSC 3 R1 1.8kΩ R2 500Ω Figure 28. Temperature-to-Frequency Converter Rev. E | Page 14 of 20 5 2 00333-028 I OUT = TMP01 OP290 V+ R1 TEMPERATURE SENSOR AND VPTAT VOLTAGE REFERENCE 2 1 2 6 7 2 100kΩ WINDOW COMPARATOR OP290 3 6 6 TMP01 6 2.5V I1 4 I2 7 2 IN4148 5 HYSTERESIS GENERATOR V+ 3 680pF REF43 4 2 4 3 R3 4 V+ V+ 7 R2 IL300XC 8 1.16V TO 1.7V OP90 5 4 3 R1 470kΩ ISOLATION BARRIER 6 604kΩ 100kΩ 00333-029 1 VREF 680pF Figure 29. Isolation Amplifier ISOLATION AMPLIFIER In many industrial applications, the sensor is located in an environment that needs to be electrically isolated from the central processing area. Figure 29 shows a simple circuit that uses an 8-pin optoisolator (IL300XC) that can operate across a 5,000 V barrier. IC1 (an OP290 single-supply amplifier) is used to drive the LED connected between Pin 1 and Pin 2. The feedback actually comes from the photodiode connected from Pin 3 to Pin 4. The OP290 drives the LED such that there is enough current generated in the photodiode to exactly equal the current derived from the VPTAT voltage across the 470 kΩ resistor. On the receiving end, an OP90 converts the current from the second photodiode to a voltage through its feedback resistor R2. Note that the other amplifier in the dual OP290 is used to buffer the 2.5 V reference voltage of the TMP01 for an accurate, low drift LED bias level without affecting the programmed hysteresis current. A REF43 (a precision 2.5 V reference) provides an accurate bias level at the receiving end. To understand this circuit, it helps to examine the overall equation for the output voltage. First, the current (I1) in the photodiode is set by 2.5 V − VPTAT In order to avoid the accuracy trim, and to reduce board space, complete isolation amplifiers are available, such as the high accuracy AD202. OUT-OF-RANGE WARNING By connecting the two open-collector outputs of the TMP01 together into a wired-OR configuration, a temperature outof-range warning signal is generated. This can be useful in sensitive equipment calibrated to work over a limited temperature range. R1, R2, and R3 in Figure 30 are chosen to give a temperature range of 10°C around room temperature (25°C). Thus, if the temperature in the equipment falls below 15°C or rises above 35°C, the OVER or UNDERoutput, respectively, goes low and turns the LED on. The LED may be replaced with a simple pullup resistor to give a logic output for controlling the instrument, or any of the switching devices discussed above can be used. V+ 470 kΩ 1 Note that the IL300XC has a gain of 0.73 (typical) with a minimum and maximum of 0.693 and 0.769, respectively. Because this is less than 1.0, R2 must be larger than R1 to achieve overall unity gain. To show this, the full equation is R1 47.5kΩ TEMPERATURE VREF SENSOR AND VPTAT VOLTAGE REFERENCE 2 R2 4.99kΩ 200Ω 7 WINDOW COMPARATOR 3 VOUT = 2.5 V − I 2 R2 = LED 8 6 R3 71.5kΩ 4 ⎛ 2.5 V − VPTAT ⎞ ⎟644 kΩ = VPTAT 2.5 V − 0.7⎜ ⎟ ⎜ 470 kΩ ⎠ ⎝ 5 HYSTERESIS GENERATOR TMP01 A trim is included for R2 to correct for the initial gain accuracy of the IL300XC. To perform this trim, simply adjust for an Rev. E | Page 15 of 20 Figure 30. Out-of-Range Warning VPTAT 00333-030 I1 = output voltage equal to VPTAT at any particular temperature. For example, at room temperature, VPTAT = 1.49 V, so adjust R2 until VOUT = 1.49 V as well. Both the REF43 and the OP90 operate from a single supply, and contribute no significant error due to drift. TMP01 However, the gain from VPTAT to the output is two, so that 5 mV/K becomes 10 mV/°C. Thus, for a temperature of 80°C, the output voltage is 800 mV. Circuit errors will be due primarily to the inaccuracies of the resistor values. Using 1% resistors, the observed error was less than 10 mV, or 1°C. The 10 pF feedback capacitor helps to ensure against oscillations. For better accuracy, an adjustment potentiometer can be added in series with either 100 kΩ resistor. TRANSLATING 5 mV/K TO 10 mV/°C A useful circuit shown in Figure 31 translates the VPTAT output voltage, which is calibrated in Kelvins, into an output that can be read directly in degrees Celsius on a voltmeter display. To accomplish this, an external amplifier is configured as a differential amplifier. The resistors are scaled so the VREF voltage exactly cancels the VPTAT voltage at 0.0°C. TRANSLATING VPTAT TO THE FAHRENHEIT SCALE 10pF 105kΩ A similar circuit to the one shown in Figure 31 can be used to translate VPTAT into an output that can be read directly in degrees Fahrenheit, with a scaling of 10 mV/°F. Only unity gain or less is available from the first stage differentiating circuit, so the second amplifier provides a gain of two to complete the conversion to the Fahrenheit scale. Using the circuit in Figure 32, a temperature of 0.0°F gives an output of 0.00 V. At room temperature (70°F), the output voltage is 700 mV. A −40°C to +85°C operating range translates into −40°F to +185°F. The errors are essentially the same as for the circuit in Figure 31. 4.22kΩ +15V 1 100kΩ TMP01 OP177 5 4.12kΩ VOUT = (10mV/°C) (VOUT = 0.0V @ T = 0.0°C) 6 487Ω 4 3 –15V 100kΩ 00333-031 VPTAT 7 2 Figure 31. Translating 5 mV/K to 10 mV/°C 10pF 90.9kΩ 100kΩ 1.0kΩ 100kΩ +15V VREF 1 2 7 3 4 TMP01 VPTAT 6 100kΩ 7 6 5 6.49kΩ 121Ω 100kΩ 5 1/2 OP297 VOUT = 0.0V @ T = 0.0°F (10mV/°F) 1/2 OP297 –15V 00333-032 VREF Figure 32. Translating 5 mV/K to 10 mV/°F Rev. E | Page 16 of 20 TMP01 OUTLINE DIMENSIONS 0.400 (10.16) 0.365 (9.27) 0.355 (9.02) 8 5 1 4 0.280 (7.11) 0.250 (6.35) 0.240 (6.10) 0.100 (2.54) BSC 0.060 (1.52) MAX 0.210 (5.33) MAX 0.015 (0.38) MIN 0.150 (3.81) 0.130 (3.30) 0.115 (2.92) SEATING PLANE 0.022 (0.56) 0.018 (0.46) 0.014 (0.36) 0.325 (8.26) 0.310 (7.87) 0.300 (7.62) 0.195 (4.95) 0.130 (3.30) 0.115 (2.92) 0.015 (0.38) GAUGE PLANE 0.014 (0.36) 0.010 (0.25) 0.008 (0.20) 0.430 (10.92) MAX 0.005 (0.13) MIN 0.070 (1.78) 0.060 (1.52) 0.045 (1.14) 070606-A COMPLIANT TO JEDEC STANDARDS MS-001 CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN. CORNER LEADS MAY BE CONFIGURED AS WHOLE OR HALF LEADS. Figure 33. .8-Lead Plastic Dual In-Line Package [PDIP] Narrow Body (N-8) Dimensions shown in inches and (millimeters) 5.00 (0.1968) 4.80 (0.1890) 1 5 4 1.27 (0.0500) BSC 0.25 (0.0098) 0.10 (0.0040) COPLANARITY 0.10 SEATING PLANE 6.20 (0.2441) 5.80 (0.2284) 1.75 (0.0688) 1.35 (0.0532) 0.51 (0.0201) 0.31 (0.0122) 0.50 (0.0196) 0.25 (0.0099) 45° 8° 0° 0.25 (0.0098) 0.17 (0.0067) 1.27 (0.0500) 0.40 (0.0157) COMPLIANT TO JEDEC STANDARDS MS-012-A A CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN. Figure 34. 8-Lead Standard Small Outline package [SOIC_N] Narrow Body (R-8) Dimensions shown in millimeters and (inches) Rev. E | Page 17 of 20 012407-A 8 4.00 (0.1574) 3.80 (0.1497) TMP01 REFERENCE PLANE 0.1850 (4.70) 0.1650 (4.19) 0.5000 (12.70) MIN 0.2500 (6.35) MIN 0.0500 (1.27) MAX 0.1000 (2.54) BSC 0.1600 (4.06) 0.1400 (3.56) 0.3350 (8.51) 0.3050 (7.75) 0.3700 (9.40) 0.3350 (8.51) 5 6 4 0.2000 (5.08) BSC 3 7 2 0.0400 (1.02) MAX 0.1000 (2.54) BSC 0.0190 (0.48) 0.0160 (0.41) 0.0210 (0.53) 0.0160 (0.41) 0.0400 (1.02) 0.0100 (0.25) 8 0.0450 (1.14) 0.0270 (0.69) 1 0.0340 (0.86) 0.0280 (0.71) 45° BSC COMPLIANT TO JEDEC STANDARDS MO-002-AK CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN. 022306-A BASE & SEATING PLANE Figure 35. 8-Pin Metal Header [TO-99] (H-08) Dimensions shown in inches and (millimeters) ORDERING GUIDE Model/Grade TMP01ES TMP01ES-REEL TMP01ESZ 1 TMP01ESZ-REEL1 TMP01FP TMP01FPZ1 TMP01FS TMP01FS-REEL TMP01FS-REEL7 TMP01FSZ1 TMP01FSZ-REEL1 TMP01FSZ-REEL71 TMP01FJ Temperature Range −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C −40°C to +85°C Package Description 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead PDIP 8-Lead PDIP 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead SOIC_N 8-Lead SOIC_N 8-Pin Metal Header (TO-99) 1 Z = RoHS Compliant Part. Rev. E | Page 18 of 20 Package Option R-8 R-8 R-8 R-8 N-8 N-8 R-8 R-8 R-8 R-8 R-8 R-8 H-08 TMP01 NOTES Rev. E | Page 19 of 20 TMP01 NOTES ©1993–2009 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D00333-0-7/09(E) Rev. E | Page 20 of 20
TMP01FSZ-REEL 价格&库存

很抱歉,暂时无法提供与“TMP01FSZ-REEL”相匹配的价格&库存,您可以联系我们找货

免费人工找货