ULTRAVOLT US SERIES
MICRO-SIZED HIGH VOLTAGE POWER SUPPLIES
Measuring only 5.75 cc (0.35 in3 ), the highly compact,
micro-sized UltraVolt® US series is specially designed
to meet the needs of design engineers working
with commercial, military, industrial, and medical
applications. These modules allow access to
voltages up to 500 V for customers with size-critical
requirements.
PRODUCT HIGHLIGHTS
Micro-sized: 5.75 cc
Programmable HV output ±0.5% F.S.
Lightweight: 13 g
Output arc and short circuit protection
PCB flat mounting: 11 mm height
5, 9 or 12 VDC Input
4 models from 0 to 200 V to 500 V
Precision 2.5 V reference
100 mW output power
TTL enable/disable/inhibit
Low ripple < 0.01% peak to peak
Output voltage monitor
Tight line/load regulation < ±0.01%
Metal case for low radiated noise
Low temperature coefficient
Optional flying lead for HV output
< ±50 ppm per °C
TYPICAL APPLICATIONS
Small, lightweight, portable devices
Ionization detectors
Fiber-optic telecom detectors
Ultrasonic transducers
Particle physics detectors
Small PZT drivers
Laser range finder detectors
ATE leakage testing
Thin-film bias
Bias supplies
Avalanche photo diodes (APD)
Silicon photomultipliers (SiPM)
Multi-pixel photon counter (MPPC)
©2020 Advanced Energy Industries, Inc.
ULTRAVOLT US SERIES
ELECTRICAL SPECIFICATIONS
Parameters
Specifications
Units
Input Voltage Vin
5 VDC ±0.5 or 12 to 15 ±0.5
VDC
Input Current
Inhibition mode: < 5 at full output voltage, full load:
< 65 (200 Vout)
mA
< 60 (300 Vout)
< 55 (400 Vout)
< 50 (500 Vout)
mA
Polarity
Fixed positive or negative
Output Voltage
0 to 200
0 to 300
0 to 400
0 to 500
VDC
-
Output Current
500
330
250
200
µA
HV Setting
Via external potentiometer, minimum resistance 10 kΩ or via external voltage source 0/2.5V ±0.5% at full
scale, and input impedance > 1 MΩ
-
Load Voltage Regulation
±0.01% of full output voltage for no load to full load
-
Line Voltage Regulation
±0.01% of full output voltage over specified input voltage range
-
Residual Ripple
< 0.01% pk to pk at full output voltage and current
-
Temperature Coefficient
< 50
PPM/°C
Output HV Monitoring
0/2.5 V signal
-
Accuracy: ±0.2% F.S.
Output impedance: 1 kΩ
Output Reference
Voltage
2.5 V ±0.5%, TC: 50 ppm/°C, max output current: 1 mA
-
HV Power ON/OFF
ON: 0 V, connected to ground
-
OFF: not connected
Open collector compatible
Operating Temperature
-10 to +65, full load, max Eout, case temp.
°C
Storage Temperature
-40 to +70
°C
Safeguards
Output current internally limited
-
Soft start feature: the start is guaranteed with no overshoot
2
advancedenergy.com
ULTRAVOLT US SERIES
MECHANICAL SPECIFICATIONS
Drawing views: third angle projections.
Dimensions
Volumes and Weights
Pin Length
> 2 mm (0.078"), spacing 2.54 mm (0.1")
Optional
Lead
Coaxial cable (RG178), diameter 2 mm (0.079"), length 500 mm (19.685")
Volume
Weight
Construction
Casing
Steel, tin-plated, thickness 0.5 mm (0.02")
Insulation
Fully potted in RTV
Pin Length
> 2 mm (0.078"), spacing 2.54 mm (0.1")
Optional
Lead
Coaxial cable (RG178), diameter 2 mm (0.079"), length 500 mm (19.685")
cc3
in3
5.750
0351 in3
g
oz
13
0.459 oz
advancedenergy.com
3
ULTRAVOLT US SERIES
INTERFACE
Connections
Pin
Function
1
Positive Power Input
2
Power Ground
3
Remote Adjust Input
4
+2.5 VDC Reference Output
5
Enable/Disable
6
Eout Monitor
7
HV Output
Mounting tabs must be connected to ground.
4
advancedenergy.com
ULTRAVOLT US SERIES
ORDERING INFORMATION
Type
Input
0 to 200 VDC Output
0.2US
0 to 300 VDC Output
0.3US
0 to 400 VDC Output
0.4US
0 to 500 VDC Output
0.5US
5 VDC Nominal
5
12 VDC Nominal
12
Power
W Output
0.1
Case
Steel, Tin-plated Case
(Standard)
Polarity
Positive Output
-P
Negative Output
-N
Output Voltage Lead Wire
-WS
Option
Popular accessories ordered with this product include the PCB-CONN-US.
The US series is not available in all territories. Please contact Advanced Energy for details concerning sales in your area.
0.5US-5-P-0.1-WS
Voltage
Option
Model
Power
Output Polarity
Input Voltage
advancedenergy.com
5
DS TITLE
ABOUT ADVANCED ENERGY
Since 1981, UltraVolt® — now part of the Advanced
Energy (AE) family — has perfected how power
performs for its customers. For both end users and
OEMs, AE’s comprehensive portfolio of standard and
custom high voltage components precisely match
system specifications to deliver unparalleled energy,
quality, and performance. Through close customer
collaboration, design expertise, application insight,
and world-class support, AE creates successful
partnerships and enables customers to push the
boundaries of innovation and stay ahead of evolving
market needs.
PRECISION | POWER | PERFORMANCE
Read and understand all documentation before
you install, operate, or maintain Advanced Energy
high voltage power supplies. Follow all safety
instructions and precautions to protect against
CAUTION:
High Voltage
For international contact information,
visit advancedenergy.com.
uv-ca@aei.com
+1.970.221.0108
property damage and serious or possibly fatal bodily
injury. Never defeat safety interlocks or grounds.
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, AE®, and UltraVolt® are U.S. trademarks
of Advanced Energy Industries, Inc.
ENG-HV-USSeries-235-01 1.20
很抱歉,暂时无法提供与“0.2US5-P0.1”相匹配的价格&库存,您可以联系我们找货