1.5M12-P0.5

1.5M12-P0.5

  • 厂商:

    ADMOS

  • 封装:

    SIP-7

  • 描述:

    高电压 - 隔离模块 直流转换器 1 输出 1500V 330µA 11V - 13V 输入

  • 数据手册
  • 价格&库存
1.5M12-P0.5 数据手册
ULTRAVOLT M SERIES MINIATURE, MICRO-SIZED HIGH VOLTAGE BIASING SUPPLIES The miniature, micro-sized M series is the ideal solution for applications requiring biasing voltage ranging from 0 to 3000 V and very small current—only 16.4 cc (1.00 in3). Less than 12.7 mm (0.5") high, these modules are ideal for low-profile applications. PRODUCT HIGHLIGHTS  Seven models from 0 to 600, 1000, 1250, 1500, 2000, 2500, or 3000 V  Output power: 0.5, 0.8, or 1 W  Tight line/load regulation  Arc and continuous short circuit protection  Self-restoring output voltage  Low cost  Miniature and lightweight  Voltage monitoring  Low ripple (0.01% peak to peak)  Optional flying lead  UL/cUL recognized, IEC-60950-1, CE Mark (LVD and RoHS) TYPICAL APPLICATIONS  Bias supplies  Electrostatic chucks  Hand held x-ray florescence (XRF)  Avalanche photo diodes (APD)  Photomultiplier tubes (PMT)  Silicon detector (SiD)  X-ray flat panel detector (FPD)  Ionization chamber detector ©2019 Advanced Energy Industries, Inc. ULTRAVOLT M SERIES ELECTRICAL SPECIFICATIONS Parameter Specifications Input Voltage Vin (Pins 1 and 2) 5 ±0.5 (2 to 3 kV ONLY) Input Voltage 5 (2 to 3 kV ONLY) 12 V Input Current No load: 55, full load: 450 No load: 45, full load: 200 mA Input Voltage 15 (600 V to 1.5 kV ONLY) 24 V Input Current No load: 40, full load: 190 No load: 35, full load: 160 mA Polarity Fixed positive or fixed negative Output Voltage 0 to 600 Input Voltage 12 15 24 12 15 24 12 15 24 12 15 24 VDC Output Power 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 W Output Current 0.83 1.33 1.67 0.5 0.8 1 0.4 0.64 0.8 0.33 0.53 0.67 mA Output Voltage 0 to 2000 Input Voltage 5 15 24 5 15 24 5 15 24 VDC Output Power 0.5 0.8 1 0.5 .0.8 1 0.5 .0.8 1 W Output Current 0.25 0.40 0.50 0.20 0.32 0.40 0.167 0.267 0.333 mA Parameter All Types Units HV Setting 10 to 100 K (potentiometer across Vref. and signal ground, wiper to adjust) - Load Voltage Regulation < 0.01% of full output voltage for no load to full load VDC Line Voltage Regulation < 0.01% of full output voltage over specified input voltage range VDC Residual Ripple < 0.01% at full load V pk to pk Temperature Coefficient 100 ppm/°C for the max output voltage after starting and over temperature range 0 to 50°C - Output Voltage Monitoring 600 to 1500 V: +1 V/1 kV max or -1 V/-1 kV max according to model polarity output impedance = to 200 kΩ ±1% - 2 to 3 kV (12 to 24 V input only): 0 to +5 V±2% - 2 to 3 kV (5 V inputs): 0 to +2.5 V±2% - 12 to 24 V input only: 5 V ±1%, TC: 100 ppm/°C, max output current: 1 mA - 5 V inputs: 2.5 V ±1%, TC: 100 ppm/°C, max output current: 1 mA - Operating Temperature -10 to +65, full load, max Eout, case temp °C Storage Temperature -40 to +70 °C Safeguards Arc and short-circuit protection - Options Shielded flying lead for HV output (0.6 to 1.5 kV units only) - Reference Voltage Units 12 ±1 15 ±1 (600 V to 1.5 kV ONLY) 0 to 1000 24 ±2 0 to 1250 0 to 2500 VDC 0 to 1500 0 to 3000 VDC Enhanced Interface (-EI) Enable/disable (ON/OFF): 0 to +0.5 V enable, +2.4V to Vinput disable (default = disable) Option (2 to 3 kV Only) Output current monitor (5 V input only): 0 to +2.5 V ±2% Output current monitor (12 to 24 V input): 0 to +5.0 V ±2% 2 advancedenergy.com VDC - ULTRAVOLT M SERIES MECHANICAL SPECIFICATIONS FLYING LEAD OPTION -WS 1 Pins 7 and 8 are available for 2 k to 3 kV units with enhanced interface option ONLY. 2 Drawing views: third angle projections. Measurements are in inches (millimeters). Construction Case Steel, tin-plated thickness 0.5 mm (0.02") Insulation Silicone-based RTV (contact factory for other options) Volume 16.4 cc (1.00 in3) Weight 35 g (1.23 oz) Tolerance Overall: ±0.76 mm (0.030") Pin to Pin: ±0.38 mm (0.015") Pin to Tab: ±0.51 mm (0.020") Tab to Tab: ±0.25 mm (0.010") 1 0.47 mm (0.019") round pins, length: 3 mm (0.12"), spacing: 2.54 mm (0.1") 2 PCB mounting through 4 mounting tabs, length: 5 mm (0.2"), width: 1.5 mm (0.059"), thickness: 0.5 mm (0.02") 3 Optional flying lead for HV output: coaxial cable (RG178), diameter: 2 mm (0.079"), length: 500 mm (19.685") (0.6 to 1.5 kV units only) advancedenergy.com 3 ULTRAVOLT M SERIES INTERFACE Connections Pin Function 1 Positive Power Input 2 Power Ground 3 Signal Ground 4 Remote Adjust Input 5 Reference Voltage 6 Voltage Monitor 7 Current Monitor 8 Enable (available with -EI option only) 9 HV Output 1 Mounting tabs must be connected to ground. 4 advancedenergy.com ULTRAVOLT M SERIES ORDERING INFORMATION Type Input Power 0 to 600 VDC Output 0.6M 0 to 1000 VDC Output 1M 0 to 1250 VDC Output 1.25M 0 to 1500 VDC Output 1.5M 0 to 2000 VDC Output 2M 0 to 2500 VDC Output 2.5M 0 to 3000 VDC Output 3M 5 VDC Nominal (2 to 3 kV only) 5 12 VDC Nominal 12 15 VDC Nominal (600 V to 1.5 kV only) 15 24 VDC Nominal 24 0.5 W Output 0.5 0.8 W Output 0.8 1 W Output 1 Case Tin Steel Case (Standard) Polarity Positive Output -P Negative Output -N Shielded Flying Lead for HV Output (600 V to 1.5 kV) -WS Current Monitor/Enable Pin (2 to 3 kV only) -EI Option The M series is not available in all territories. Please contact Advanced Energy for details concerning sales in your area. 1.5M24-P1-WS Voltage Option Model Power Output Polarity Input Voltage advancedenergy.com 5 ABOUT ADVANCED ENERGY Since 1981, Advanced Energy (AE) — and its UltraVolt® family of products — has perfected how power performs for its customers. For both end users and OEMs, AE’s comprehensive portfolio of standard and custom high voltage components precisely match system specifications to deliver unparalleled energy, quality, and performance. Through close customer collaboration, design expertise, application insight, and world-class support, AE creates successful partnerships and enables customers to push the boundaries of innovation and stay ahead of evolving market needs. PRECISION | POWER | PERFORMANCE Read and understand all documentation before you install, operate, or maintain Advanced Energy high voltage power supplies. Follow all safety instructions and precautions to protect against CAUTION: High Voltage For international contact information, visit advancedenergy.com. uv-ca@aei.com +1.970.221.0108 property damage and serious or possibly fatal bodily injury. Never defeat safety interlocks or grounds. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2019 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE®, and UltraVolt® are U.S. trademarks of Advanced Energy Industries, Inc. ENG-HV-Mseries-235-01 8.19
1.5M12-P0.5 价格&库存

很抱歉,暂时无法提供与“1.5M12-P0.5”相匹配的价格&库存,您可以联系我们找货

免费人工找货