ULTRAVOLT M SERIES
MINIATURE, MICRO-SIZED HIGH VOLTAGE BIASING SUPPLIES
The miniature, micro-sized M series is the ideal solution
for applications requiring biasing voltage ranging
from 0 to 3000 V and very small current—only 16.4 cc
(1.00 in3). Less than 12.7 mm (0.5") high, these modules
are ideal for low-profile applications.
PRODUCT HIGHLIGHTS
Seven models from 0 to 600, 1000, 1250, 1500, 2000, 2500, or 3000 V
Output power: 0.5, 0.8, or 1 W
Tight line/load regulation
Arc and continuous short circuit protection
Self-restoring output voltage
Low cost
Miniature and lightweight
Voltage monitoring
Low ripple (0.01% peak to peak)
Optional flying lead
UL/cUL recognized, IEC-60950-1, CE Mark (LVD and RoHS)
TYPICAL APPLICATIONS
Bias supplies
Electrostatic chucks
Hand held x-ray florescence (XRF)
Avalanche photo diodes (APD)
Photomultiplier tubes (PMT)
Silicon detector (SiD)
X-ray flat panel detector (FPD)
Ionization chamber detector
©2019 Advanced Energy Industries, Inc.
ULTRAVOLT M SERIES
ELECTRICAL SPECIFICATIONS
Parameter
Specifications
Input Voltage Vin
(Pins 1 and 2)
5 ±0.5 (2 to 3 kV ONLY)
Input Voltage
5 (2 to 3 kV ONLY)
12
V
Input Current
No load: 55, full load: 450
No load: 45, full load: 200
mA
Input Voltage
15 (600 V to 1.5 kV ONLY)
24
V
Input Current
No load: 40, full load: 190
No load: 35, full load: 160
mA
Polarity
Fixed positive or fixed negative
Output Voltage
0 to 600
Input Voltage
12
15
24
12
15
24
12
15
24
12
15
24
VDC
Output Power
0.5
0.8
1
0.5
0.8
1
0.5
0.8
1
0.5
0.8
1
W
Output Current
0.83
1.33
1.67
0.5
0.8
1
0.4
0.64
0.8
0.33
0.53
0.67
mA
Output Voltage
0 to 2000
Input Voltage
5
15
24
5
15
24
5
15
24
VDC
Output Power
0.5
0.8
1
0.5
.0.8
1
0.5
.0.8
1
W
Output Current
0.25
0.40
0.50
0.20
0.32
0.40
0.167
0.267
0.333
mA
Parameter
All Types
Units
HV Setting
10 to 100 K (potentiometer across Vref. and signal ground, wiper to adjust)
-
Load Voltage Regulation
< 0.01% of full output voltage for no load to full load
VDC
Line Voltage Regulation
< 0.01% of full output voltage over specified input voltage range
VDC
Residual Ripple
< 0.01% at full load
V pk to pk
Temperature Coefficient
100 ppm/°C for the max output voltage after starting and over temperature range 0 to 50°C
-
Output Voltage
Monitoring
600 to 1500 V: +1 V/1 kV max or -1 V/-1 kV max according to model polarity output impedance = to 200
kΩ ±1%
-
2 to 3 kV (12 to 24 V input only): 0 to +5 V±2%
-
2 to 3 kV (5 V inputs): 0 to +2.5 V±2%
-
12 to 24 V input only: 5 V ±1%, TC: 100 ppm/°C, max output current: 1 mA
-
5 V inputs: 2.5 V ±1%, TC: 100 ppm/°C, max output current: 1 mA
-
Operating Temperature
-10 to +65, full load, max Eout, case temp
°C
Storage Temperature
-40 to +70
°C
Safeguards
Arc and short-circuit protection
-
Options
Shielded flying lead for HV output (0.6 to 1.5 kV units only)
-
Reference Voltage
Units
12 ±1
15 ±1 (600 V
to 1.5 kV ONLY)
0 to 1000
24 ±2
0 to 1250
0 to 2500
VDC
0 to 1500
0 to 3000
VDC
Enhanced Interface (-EI) Enable/disable (ON/OFF): 0 to +0.5 V enable, +2.4V to Vinput disable (default = disable)
Option (2 to 3 kV Only)
Output current monitor (5 V input only): 0 to +2.5 V ±2%
Output current monitor (12 to 24 V input): 0 to +5.0 V ±2%
2 advancedenergy.com
VDC
-
ULTRAVOLT M SERIES
MECHANICAL SPECIFICATIONS
FLYING LEAD OPTION -WS
1 Pins 7 and 8 are available for 2 k to 3 kV units with enhanced interface option ONLY.
2 Drawing views: third angle projections. Measurements are in inches (millimeters).
Construction
Case
Steel, tin-plated thickness 0.5 mm (0.02")
Insulation
Silicone-based RTV (contact factory for other options)
Volume
16.4 cc (1.00 in3)
Weight
35 g (1.23 oz)
Tolerance
Overall: ±0.76 mm (0.030")
Pin to Pin: ±0.38 mm (0.015")
Pin to Tab: ±0.51 mm (0.020")
Tab to Tab: ±0.25 mm (0.010")
1 0.47 mm (0.019") round pins, length: 3 mm (0.12"), spacing: 2.54 mm (0.1")
2 PCB mounting through 4 mounting tabs, length: 5 mm (0.2"), width: 1.5 mm (0.059"), thickness: 0.5 mm (0.02")
3 Optional flying lead for HV output: coaxial cable (RG178), diameter: 2 mm (0.079"), length: 500 mm (19.685") (0.6 to 1.5 kV units only)
advancedenergy.com
3
ULTRAVOLT M SERIES
INTERFACE
Connections
Pin
Function
1
Positive Power Input
2
Power Ground
3
Signal Ground
4
Remote Adjust Input
5
Reference Voltage
6
Voltage Monitor
7
Current Monitor
8
Enable (available with -EI option only)
9
HV Output
1 Mounting tabs must be connected to ground.
4 advancedenergy.com
ULTRAVOLT M SERIES
ORDERING INFORMATION
Type
Input
Power
0 to 600 VDC Output
0.6M
0 to 1000 VDC Output
1M
0 to 1250 VDC Output
1.25M
0 to 1500 VDC Output
1.5M
0 to 2000 VDC Output
2M
0 to 2500 VDC Output
2.5M
0 to 3000 VDC Output
3M
5 VDC Nominal (2 to 3 kV only)
5
12 VDC Nominal
12
15 VDC Nominal (600 V to 1.5 kV only)
15
24 VDC Nominal
24
0.5 W Output
0.5
0.8 W Output
0.8
1 W Output
1
Case
Tin Steel Case
(Standard)
Polarity
Positive Output
-P
Negative Output
-N
Shielded Flying Lead for HV Output (600 V to 1.5 kV)
-WS
Current Monitor/Enable Pin (2 to 3 kV only)
-EI
Option
The M series is not available in all territories. Please contact Advanced Energy for details concerning sales in your area.
1.5M24-P1-WS
Voltage
Option
Model
Power
Output Polarity
Input Voltage
advancedenergy.com
5
ABOUT ADVANCED ENERGY
Since 1981, Advanced Energy (AE) — and its UltraVolt®
family of products — has perfected how power
performs for its customers. For both end users and
OEMs, AE’s comprehensive portfolio of standard and
custom high voltage components precisely match
system specifications to deliver unparalleled energy,
quality, and performance. Through close customer
collaboration, design expertise, application insight,
and world-class support, AE creates successful
partnerships and enables customers to push the
boundaries of innovation and stay ahead of evolving
market needs.
PRECISION | POWER | PERFORMANCE
Read and understand all documentation before
you install, operate, or maintain Advanced Energy
high voltage power supplies. Follow all safety
instructions and precautions to protect against
CAUTION:
High Voltage
For international contact information,
visit advancedenergy.com.
uv-ca@aei.com
+1.970.221.0108
property damage and serious or possibly fatal bodily
injury. Never defeat safety interlocks or grounds.
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2019 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, AE®, and UltraVolt® are U.S. trademarks
of Advanced Energy Industries, Inc.
ENG-HV-Mseries-235-01 8.19