0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LXC96-2100SW

LXC96-2100SW

  • 厂商:

    ADMOS

  • 封装:

  • 描述:

    2.1A 22 ~ 45.7V 恒定电流 LED 驱动器 AC DC 转换器 拓扑 1 输出

  • 数据手册
  • 价格&库存
LXC96-2100SW 数据手册
LED Power Supplies 96W LED Power 96W LXC96 series LED Power Supply Constant Current LED Power Supplies The LXC96 series of Class 2 constant current LED power supplies from Excelsys Technologies can deliver up to 96W of output power in an extremely compact package size. LED POWER next generation power source The LXC96 series of constant current power supplies provides up to 4000mA of output current and 274V output voltage solutions for specific LED requirements. With industry leading efficiencies, and an extensive protection feature set, the LXC96 series provides high reliability and high performance in a compact package. FEATURES • High Efficiency (up to 92%) • UL1310 Class 2 • Active PFC (Typical 0.99) • IP67 Waterproof • OVP, SCP, OTP • -35 to 70°C deg operation • Universal Input 90-305VAC • UL8750 compliant • EN61347-1, -2-13 compliant Model Number Output Voltage Output Current Input Voltage Efficiency 90-305VAC OVP Latching max 310V LXC96-0350SW 137-274V 350mA LXC96-0450SW 106-213V 450mA 90-305VAC 250V LXC96-0700SW 68-137V 92.0% 700mA 90-305VAC 170V LXC96-1050SW 91.0% 46-92V 1050mA 90-305VAC 120V 91.0% LXC96-1400SW 35-69V 1400mA 90-305VAC 100V 90.0% LXC96-1750SW(C) 27-54.8V 1750mA 90-305VAC 75V 90.0% LXC96-2100SW(C) 22-45.7V 2100mA 90-305VAC 60V 89.0% LXC96-2450SW(D) 19-39.1V 2450mA 90-305VAC 55V 89.0% LXC96-2800SW(D) 17-34.2V 2800mA 90-305VAC 50V 89.0% LXC96-3150SW(D) 15-30.4V 3150mA 90-305VAC 45V 88.0% LXC96-3500SW(D) 13-27.4V 3500mA 90-305VAC 40V 88.0% LXC96-4000SW(E) 12-24V 4000mA 90-305VAC 35V 88.0% 92.0% Input Specifications Parameter Input Voltage Range Input Frequency Range Input Current Leakage Current Inrush Current Power Factor Conditions/Description Universal Input Min 90 47 100VAC in, 96W output 277VAC in, 50Hz 230VAC in, 25°C, Cold Start 220VAC, 110VAC 0.96 Conditions/Description Min Nom Max 305 63 1.2 1.0 50 0.99 Units VAC Hz A mA A Nom Max ±1 ±3 Units % % ±5 3.0 10 1 % % pk-pk % s Output Specifications Parameter Line Regulation Load Regulation Voltage Range Output Current Accuracy Ripple and Noise Overshoot Turn-on Delay Short Circuit Protection Over Voltage Protection Over Temp Protection See table of outputs % of Iout 20MHz Bandwidth Measured at 220VAC and full load Auto Recovery Latching. See individual models OVP levels Auto Recovery. Internal component temperature 0.6 110 °C 1 General Specifications Parameter Isolation Voltage Efficiency Safety Agency Approvals No load Power Dissipation MTBF Lifetime Weight Operating Temperature Storage Temperature Relative Humidity Conditions/Description Input to Output See Note A Input to Chassis See individual models UL8750, EN61347-1, -2-13 Measured at 230 VAC MIL-HDBK-217F, 110VAC input, 80% Load, 25°C 45°C, 110VAC Input, 80% Load Min 3750 1500 Maximum Case Temperatire Tcase =89°C -35 -40 10 Non-condensing (operating) Europe/Asia Excelsys Technologies Ltd 27 Eastgate Drive Eastgate Business Park Little Island, Cork, Ireland IRELAND Nom Max 90.5 1.0 400,000 50,000 850 +70 +85 100 North America t: +353 21 4354716 Excelsys Technologies f: +353 21 4354864 519 Interstate 30, #309 e: sales@excelsys.com Rockwall, TX 75087 USA Units VAC VAC % W Hours Hours g °C °C %RH t: (972) 771 4544 f: (972) 421 1805 e: salesusa@excelsys.com LED Power Supplies 96W EMC LED Power 96W Parameter Emissions Conducted Radiated Harmonic Distortion Flicker and Fluctuation Immunity ESD Radiated RFI Fast Transients - burst Surge Immunity Conducted RFI Power Freq Magnetic Field Voltage Dips Note Note Note Note Note A. B. C. D. E. Standard Level Units EN55015 EN55015 EN61000-3-2 EN61000-3-3 Compliant Compliant Compliant Compliant EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Level 4 Level 3 Level 4 Level 4 Compliant Compliant Primary to Secondary Isolation test not to be carried on power supply. Load Voltage must be maintained above minimum voltage. See models for voltage range. Class 2 (USR) and Non Class 2( CNR) for dry and damp locations Class 2 (USR and CNR) for dry and damp locations, CSA Class 2 for wet location. Class 2 (USR and CNR) for dry and damp locations and Class 2 (USR and CNR) for wet location. INPUT / OUTPUT WIRING INPUT CABLE SJTW 18AWG 3C Black (L),White(N), Green (G)650±20mm OUTPUT CABLE SJTW 18AWG 2C Black (-V) and Red (+V) 220±20mm MECHANICAL SPECIFICATIONS 201 174 170 67.5 25±5 25±5 15 ± 2 220 ± 20 37 650 ± 20 188 184 5 50 8 34 15±2 37 4 10.5 Specifications are subject to change without notice LXC96 Datasheet Pre Release 18 March 2011 Europe/Asia Excelsys Technologies Ltd 27 Eastgate Drive Eastgate Business Park Little Island, Cork, Ireland IRELAND North America t: +353 21 4354716 Excelsys Technologies f: +353 21 4354864 519 Interstate 30, #309 e: sales@excelsys.com Rockwall, TX 75087 USA t: (972) 771 4544 f: (972) 421 1805 e: salesusa@excelsys.com
LXC96-2100SW 价格&库存

很抱歉,暂时无法提供与“LXC96-2100SW”相匹配的价格&库存,您可以联系我们找货

免费人工找货