ULTRAVOLT MPM 100 TO 500 SERIES
COMPACT DC TO HIGH VOLTAGE DC CONVERTERS
=
The UltraVolt® MPM series of proportional DC-to-DC
converters provide compact, general purpose high
voltage power.
PRODUCT HIGHLIGHTS
Unregulated proportional control outputs ranging from 100 to 500 VDC maximum
AT A GLANCE
Single output: positive and negative polarity models
1.5 W maximum output power
12 or 24 VDC input
Output ripple performance < 0.5% (to < 0.05% with optional shield)
Temperature coefficient < 300 ppm/°C
Maximum Output Voltage
100, 200, 300, or 500 VDC
PCB-mount
Maximum Output Power
Reversed polarity and intermittent short-circuit protection
1.5 W
Optional 100 VDC isolation between input and high voltage output
Available shielded case to guard against external radiated emissions
CE mark (LVD and RoHS)
Type
Single Output
Ripple
TYPICAL APPLICATIONS
< 0.5%
DC to high voltage DC bias supplies for general purpose uses
Control Interface
Ink-jet printers and electrostatic separators
Rail supplies for PMT/APD detectors and Geiger-Muller tubes
Electron-beam deflectors and focusing optics
Proportional
Temperature Coefficient
< 300 ppm/°C
©2021 Advanced Energy Industries, Inc.
ULTRAVOLT MPM 100 TO 500 SERIES
ELECTRICAL SPECIFICATIONS
Model 1
100 Series
200 Series
High Voltage Output Range (Proportional, Positive or Negative)
17 to 100 VDC
34 to 200 VDC
High Voltage Outputs
Single
Input Voltage (VDC, Nominal)
12 VDC
Power Output (Watts, Nominal)
1.5 W
Single
24 VDC
12 VDC
24 VDC
1.5 W
DC Input
Vin (Input Voltage) Range
VDC (positive polarity only)
0 to 12
0 to 24
0 to 12
0 to 24
Vin (Nominal)
VDC
2 to 12
4 to 24
2 to 12
4 to 24
lin (Input Current, Nominal)
A @ 100% HVout, 100% LOAD
< 0.25
< 0.13
< 0.25
< 0.13
A @ 100% HVout, 0% LOAD
< 0.04
VDC (positive polarity models = +HVout)
+17 to +100
+17 to +100
+34 to +200
+34 to +200
VDC (negative polarity models = -HVout)
-17 to -100
-17 to -100
-34 to -200
-34 to -200
< 0.04
DC Output
HVout (Output Voltage)
Iout (Output Current)
mA (max) @ 0 to 100% HVout, Vin (nominal) 15
7.5
Pout (Output Power)
Watts (max)
1.5
1.5
Ripple 2 3
% (% with S option)
< 0.5% (< 0.25%)
< 0.5% (< 0.05%)
ppm (ppm with S option)
< 5000 (< 2500)
< 5000 (< 500)
Vpp (Vpp with S option)
< 0.5 (< 0.25)
< 1 (< 0.1)
Model 1
300 Series
500 Series
High Voltage Output Range (Proportional, Positive or Negative)
50 to 300 VDC
84 to 500 VDC
High Voltage Outputs
Single
Input Voltage (VDC, Nominal)
12 VDC
Power Output (Watts, Nominal)
1.5 W
,
Single
24 VDC
12 VDC
24 VDC
1.5 W
DC Input
Vin (Input Voltage) Range
VDC (positive polarity only)
0 to 12
0 to 24
0 to 12
0 to 24
Vin (Nominal)
VDC
2 to 12
4 to 24
2 to 12
4 to 24
lin (Input Current, Nominal)
A @ 100% HVout, 100% LOAD
< 0.25
< 0.13
< 0.25
< 0 .13
A @ 100% HVout, 0% LOAD
< 0.04
VDC (positive polarity models = +HVout)
+50 to +300
+50 to +300
+84 to +500
+84 to +500
VDC (negative polarity models = -HVout)
-50 to -300
-50 to -300
-84 to -500
-84 to -500
< 0.04
DC Output
HVout (Output Voltage)
Iout (Output Current)
mA (max) @ 0 to 100% HVout, Vin (nominal) 5
3
Pout (Output Power)
Watts (max)
1.5
1.5
Ripple 2 3
% (% with S option)
< 0.5% (< 0.05%)
< 0.5% (< 0.05%)
ppm (ppm with S option)
< 5000 (< 500)
< 5000 (< 500)
Vpp (Vpp with S option)
< 1.5 (< 0.15)
< 2.5 (< 0.25)
,
1 Standard product specifications shown unless noted. For 1000 to 3000 VDC HVout ranges, see MPM 1K to 3K series datasheet.
2 Nominal ripple measured @ 100% HVout, 100% LOAD into 300 pf bypass capacitor.
3 % = percent @ 100% HVout; ppm = parts per million @ 100% HVout; Vpp = VDC peak to peak @ 100% HVout.
2
advanced-energy.com
ULTRAVOLT MPM 100 TO 500 SERIES
ELECTRICAL SPECIFICATIONS (CONTINUED)
Stability and Regulation
Stability
0.1% (1000 ppm) @ 100% HVout (after 30 min warmup interval)
0.1% (1000 ppm) @ 100% HVout (per 8 h interval)
Line Regulation
Unregulated (proportional control)
Static Load Regulation
Typically < 10% @ 100% HVout, 0 to 100% LOAD. Max < 20%
Temperature Coefficient
300 ppm/°C (over operating temperature range)
Power-On Rise Time
< 50 msec @ 100% LOAD, < 50 msec @ 0% LOAD
Contact factory for other options.
Environmental
Operating Temperature Range
-10 to 60°C (14 to 140°F) ambient temperature
Storage
-40 to 85°C (-40 to 185°F) ambient temperature
Humidity
0 to 95% RH, non-condensing
Altitude
Sea level to 2000 m (6500 ft)
Regulatory
Certifications
CE mark (LVD and RoHS)
advanced-energy.com
3
ULTRAVOLT MPM 100 TO 500 SERIES
MECHANICAL SPECIFICATIONS
L
4
3
W
W2
W4
Standard Configuration
W1
2
1
L4
H
L3
H1
Side View
L1
Back View
L
Shield Pin
L5
2
HVout
H
4
3
1
L1
H1
Dimensions
Standard
Key
Description 1, 2, 3
mm
in
mm
in
L
Overall Length
38.1
1.50
39.4
1.55
L1
Case Exterior to Pin 1 (Pin 2)
4.1
0.16
4.8
0.19
L3
Pin 1 to Pin 3
27.9
1.10
27.9
1.10
L4
Pin 1 to Pin 4 (I Option)
10.7
0.4
10.7
0.42
L5
Case Exterior to Shield Ground (S Option)
38.9
1.53
W
Overall Width
38.1
1.50
39.4
1.55
W1
Case Exterior to Pin 1 (Pin 3)
2.5
0.10
3.0
0.12
W2
Pin 1 to Pin 2
30.5
1.20
30.5
W4
Pin 1 to Pin 4 (I Option)
W5
Pin 1 to Shield Ground (S Option)
H
H1
Shielded
Construction
Standard Case
Injection-molded plastic
(Diallyl Phthalate, DAP,
per ASTM-D-5948)
Optional Shield
Five-sided tinned metal
case with PCB (S Option)
Labels
Static-dissipative
polyester
Cooling
Natural convection
and conduction
1.20
Encapsulation
Silicone-based RTV
1.3
0.05
Pins
Gold/nickel over brass
(D = 1 mm, 0.040 in)
Shield Ground
Tinned metal
(0.7 x 0.5 mm,
0.028 x 0.02 in)
1.3
0.05
38.1
1.50
Case Height (Max)
20.1
0.79
21.6
0.85
Case Exterior to Pin 1 Tip
8.6
0.34
8.1
0.32
Volumes and Weights
Standard
cm
Volume (Module Body Only)
Weight
W
W1
HVret
(I Option)
W5
Shielded (S Option)
3
Shielded
in
3
cm3
in3
29.1
1.8
33.5
2.0
g
oz
g
oz
60
2.1
80
2.8
1 Approximate nominal dimensions and weights for configurations shown.
2 Standard case (DAP plastic) tolerances are ±1.27 mm (±0.050 in). Pin-to-pin tolerances are ±0.76 mm (±0.015 in).
3 Refer to outline drawings and 3D models for detailed information.
4
advanced-energy.com
ULTRAVOLT MPM 100 TO 500 SERIES
INTERFACE
The MPM series’ high voltage output varies proportionately with input voltage. An optional interface isolates input
from high voltage output, up to a maximum of 100 VDC. The shield — which helps protect the module from external
radiated emissions — should be connected to ground.
Shield (S Option)
Example
Interface Circuit
Pin
2
Standard Interface (Non-isolated)
All impedances ±1%
Vin
HVout
3
F
Iout
Ro
C
LOAD
Pin
Label
Type
Description
1
Gnd
Ground
DC Input Power Ground
High Voltage Return
2
Vin
Input
DC Input Power
3
HVout
Output
High Voltage Output
Ground
Shield Ground
Shield
+
1
Gnd
HVret
Shield (S Option)
Example
Interface Circuit
Pin
2
Isolated Interface (I Option, 100 VDC Max)
All impedances ±1%
Vin
HVout
3
F
Iout
C
Ro
LOAD
+
Pin
Label
Type
Description
1
Gnd
Ground
DC Input Power Ground
2
Vin
Input
DC Input Power
3
HVout
Output
High Voltage Output
4
HVret
Ground
High Voltage Return 1
Ground
Shield Ground
Shield
1 For proper operation and safety, always route HVret signal through HVret
connection.
1
Gnd
HVret
4
100 VDC Isolation
(Max)
advanced-energy.com
5
ULTRAVOLT MPM 100 TO 500 SERIES
INTERFACE CONTROL PARAMETERS
Model
100 Series
High Voltage Output Range (Proportional, Positive or Negative)
17 to 100 VDC
Input Voltage (VDC, Max)
12 VDC
Power Output (Watts, Max)
1.5 W
200 Series
34 to 200 VDC
24 VDC
12 VDC
24 VDC
1.5 W
Standard Interface (Proportional Voltage Control)
Scale Factors 1, 2, 3
Positive Polarity Models
SVp (V/V) where HVout Control = SVp x Vin
8.33
4.17
16.7
8.33
Negative Polarity Models
SVp (V/V) where HVout Control = SVp x Vin
-8.33
-4.17
-16.7
-8.33
Impedances 3
Ro (HVout impedance, ±1%)
2.2 MΩ
2.2 MΩ
Capacitance 3
C (@ 50 VDC ±10%, ⅛ W, max)
4.7 µF
4.7 µF
Model
300 Series
500 Series
High Voltage Output Range (Proportional, Positive or Negative)
50 to 300 VDC
Input Voltage (VDC, Max)
12 VDC
Power Output (Watts, Max)
1.5 W
Other Interface Values
84 to 500 VDC
24 VDC
12 VDC
24 VDC
1.5 W
Standard Interface (Proportional Voltage Control)
Scale Factors 1, 2, 3
Positive Polarity Models
SVp (V/V) where HVout Control = SVp x Vin
25
12.5
41.7
20.8
Negative Polarity Models
SVp (V/V) where HVout Control = SVp x Vin
-25
-12.5
-41.7
-20.8
Impedances 3
Ro (HVout impedance, ±1%)
2.2 MΩ
2.2 MΩ
Capacitance 3
C (@ 50 VDC = ±10%, 1/8 W, max)
4.7 µF
4.7 µF
Other Interface Values
1 For 12 VDC models, Vin (nominal) varies from 2 to 12 VDC. For 24 VDC models, Vin (nominal) varies from 4 to 24 VDC. Contact factory about operation below these levels.
2 SVp can vary by ±10% typical (±20% max) from 17 to 100% HVout @ 100% LOAD.
3 See interface schematic for definition.
STANDARD OPTIONS
The MPM series can be factory configured with several standard options that adapt its performance to specialized
application requirements.
Option
Description
S
Six-sided shielded case consisting of tin-plated metal case and mating PCB that provides additional protection from external
radiated emissions.
I
Isolation up to 100 VDC maximum between input and high voltage output. Permits use of an external resistor between HVret and
ground to sense current, or an external capacitor to reduce common mode ripple.
ORDERING INFORMATION
6
advanced-energy.com
ULTRAVOLT MPM 100 TO 500 SERIES
STANDARD CONFIGURATION
Shielded Case (6 Sides)
Module Isolation (100 VDC Max)
Pos
1.5
Included
S
I
12
Neg
1.5
Included
S
I
MPM24-100P
1
+17 to +100
24
Pos
1.5
Included
S
I
MPM24-100N
1
-17 to -100
24
Neg
1.5
Included
S
I
MPM12-200P
1
+34 to +200
12
Pos
1.5
Included
S
I
MPM12-200N
1
-34 to -200
12
Neg
1.5
Included
S
I
MPM24-200P
1
+34 to +200
24
Pos
1.5
Included
S
I
MPM24-200N
1
-34 to -200
24
Neg
1.5
Included
S
I
MPM12-300P
1
+50 to +300
12
Pos
1.5
Included
S
I
MPM12-300N
1
-50 to -300
12
Neg
1.5
Included
S
I
MPM24-300P
1
+50 to +300
24
Pos
1.5
Included
S
I
MPM24-300N
1
-50 to -300
24
Neg
1.5
Included
S
I
MPM12-500P
1
+84 to +500
12
Pos
1.5
Included
S
I
MPM12-500N
1
-84 to -500
12
Neg
1.5
Included
S
I
MPM24-500P
1
+84 to +500
24
Pos
1.5
Included
S
I
MPM24-500N
1
-84 to -500
24
Neg
1.5
Included
S
I
100 Series
200 Series
300 Series
Plastic Case (DAP)
300 ppm/°C Temperature Coefficient
High Voltage Output Power (Pout, Watts)
12
-17 to -100
Reversed Polarity Input and Intermittent
Short-circuit Protec tion
High Voltage Output Polarity
+17 to +100
1
Through-hole PCB-mount
Maximum Input Voltage (Vin, VDC)
1
MPM12-100N
Proporational Control Interface
High Voltage Output Range
(HVout VDC, Proportional to Vin)
MPM12-100P
Standard Part
500 Series
OPTIONS
Standard Features
Number of High Voltage Outputs
Electrical Performance
Options
Standard Part
MPM24-500NSI
Model
Input Voltage
Output Polarity
Output Voltage
advanced-energy.com
7
DS TITLE
ABOUT ADVANCED ENERGY
Since 1981, UltraVolt® — now part of the Advanced
Energy (AE) family — has perfected how power
performs for its customers. For both end users and
OEMs, AE’s comprehensive portfolio of standard and
custom high voltage components precisely match
system specifications to deliver unparalleled energy,
quality, and performance. Through close customer
collaboration, design expertise, application insight,
and world-class support, AE creates successful
partnerships and enables customers to push the
boundaries of innovation and stay ahead of evolving
market needs.
PRECISION | POWER | PERFORMANCE
Read and understand all documentation before
you install, operate, or maintain Advanced Energy
high voltage power supplies. Follow all safety
instructions and precautions to protect against
CAUTION:
High Voltage
For international contact information,
visit advanced-energy.com.
uv-ca@aei.com
+1.970.221.0108
property damage and serious or possibly fatal bodily
injury. Never defeat safety interlocks or grounds.
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, AE®, and UltraVolt® are U.S. trademarks
of Advanced Energy Industries, Inc.
ENG-HV-MPM-100V500V-235-01 3.21