1000V 2x60A APT60D100LCT APT60D100LCTG*
*G Denotes RoHS Compliant, Pb Free Terminal Finish.
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
PRODUCT APPLICATIONS
• Anti-Parallel Diode -Switchmode Power Supply -Inverters • Free Wheeling Diode -Motor Controllers -Converters -Inverters • Snubber Diode • PFC
PRODUCT FEATURES
• Ultrafast Recovery Times • Soft Recovery Characteristics • Popular TO-264 Package • Low Forward Voltage • Low Leakage Current
PRODUCT BENEFITS
• Low Losses • Low Noise Switching • Cooler Operation • Higher Reliability Systems • Increased System Power Density
1
TO -26 4
2
3
1 2
3
1 - Anode 1 2 - Common Cathode Back of Case - Cathode 3 - Anode 2
MAXIMUM RATINGS
Symbol VR VRRM VRWM IF(AV) IF(AV) IFSM TJ,TSTG TL Characteristic / Test Conditions Maximum D.C. Reverse Voltage Maximum Peak Repetitive Reverse Voltage Maximum Working Peak Reverse Voltage
All Ratings Per Leg: TC = 25°C unless otherwise specified.
APT60D100LCT(G) UNIT
1000
Volts
Maximum Average Forward Current (TC = 142°C, Duty Cycle = 0.5) RMS Forward Current (Square wave, 50% duty) Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms) Operating and StorageTemperature Range Lead Temperature for 10 Sec.
60 152 540 -55 to 175 300
°C Amps
STATIC ELECTRICAL CHARACTERISTICS
Symbol Characteristic / Test Conditions IF = 60A VF Forward Voltage IF = 120A IF = 60A, TJ = 125°C IRM CT Maximum Reverse Leakage Current Junction Capacitance, VR = 200V
APT Website - http://www.advancedpower.com
MIN
TYP
MAX
UNIT
1.9 2.2 1.7
2.5
Volts
VR = VR Rated, TJ = 125°C
500 65
053-0015 Rev B
pF
4-2005
VR = VR Rated
250
µA
DYNAMIC CHARACTERISTICS
Symbol trr trr Qrr IRRM trr Qrr IRRM trr Qrr IRRM Characteristic Reverse Recovery Time Reverse Recovery Time Reverse Recovery Charge Maximum Reverse Recovery Current Reverse Recovery Time Reverse Recovery Charge Maximum Reverse Recovery Current Reverse Recovery Time Reverse Recovery Charge Maximum Reverse Recovery Current IF = XA, diF/dt = -X000A/µs VR = X00V, TC = 125°C IF = XA, diF/dt = -200A/µs VR = X00V, TC = 125°C IF = XA, diF/dt = -200A/µs VR = X00V, TC = 25°C Test Conditions IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C MIN -
APT60D100LCT(G)
TYP MAX UNIT ns nC
34 280 760 6 350 3600 16 170 5650 50 -
-
Amps ns nC Amps ns nC Amps
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol RθJC RθJA WT Characteristic / Test Conditions Junction-to-Case Thermal Resistance Junction-to-Ambient Thermal Resistance Package Weight MIN TYP MAX UNIT °C/W oz g
.21 40 0.22 5.9 10 1.1
lb•in N•m
Torque
Maximum Mounting Torque
APT Reserves the right to change, without notice, the specifications and information contained herein. 0.25 Z JC, THERMAL IMPEDANCE (°C/W) θ
0.20
0.9 0.7 0.5 0.3
Note:
0.15
PDM
0.10
t1 t2
0.05 0.1 0.05 10
-5
SINGLE PULSE 10
-4
Duty Factor D = 1/t2 Peak TJ = PDM x ZθJC + TC
t
0
10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (seconds) FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
RC MODEL Junction temp (°C) 0.0152 °C/W 0.00643 J/°C
4-2005
Power (watts)
0.0833 °C/W
0.0170 J/°C
053-0015 Rev B
0.112 °C/W Case temperature (°C)
0.173 J/°C
FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL
TYPICAL PERFORMANCE CURVES
200 180 IF, FORWARD CURRENT (A) 160 140 120 100 80 60 40 20 0 0 TJ = 150°C trr, REVERSE RECOVERY TIME (ns)
500 120A 400 60A
APT60D100LCT(G)
T = 125°C J V = 667V
R
300
30A 200
TJ = 125°C
TJ = 25°C TJ = -55°C
100
0.5 1 1.5 2 2.5 3 VF, ANODE-TO-CATHODE VOLTAGE (V) Figure 2. Forward Current vs. Forward Voltage 8000 Qrr, REVERSE RECOVERY CHARGE (nC) 7000 6000 5000 4000 3000 2000 1000 0 30A 60A
T = 125°C J V = 667V
R
0 200 400 600 800 1000 1200 -diF /dt, CURRENT RATE OF CHANGE(A/µs) Figure 3. Reverse Recovery Time vs. Current Rate of Change IRRM, REVERSE RECOVERY CURRENT (A) 60 50 40 30 20
T = 125°C J V = 667V
R
0
120A
120A
60A
30A
10 0
0 200 400 600 800 1000 1200 -diF /dt, CURRENT RATE OF CHANGE (A/µs) Figure 4. Reverse Recovery Charge vs. Current Rate of Change 1.4 Kf, DYNAMIC PARAMETERS (Normalized to 1000A/µs) 1.2 1.0 0.8 0.6 t rr 0.4 0.2
0 200 400 600 800 1000 1200 -diF /dt, CURRENT RATE OF CHANGE (A/µs) Figure 5. Reverse Recovery Current vs. Current Rate of Change 180
Duty cycle = 0.5 T = 175°C
J
trr Qrr
IF(AV) (A)
160 140 120 100 80 60 40 20
IRRM
Qrr
25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) Figure 6. Dynamic Parameters vs. Junction Temperature
600 CJ, JUNCTION CAPACITANCE (pF) 500 400 300 200 100 0
0.0
0
75 100 125 150 175 Case Temperature (°C) Figure 7. Maximum Average Forward Current vs. CaseTemperature
0
25
50
10 100 200 VR, REVERSE VOLTAGE (V) Figure 8. Junction Capacitance vs. Reverse Voltage
1
053-0015 Rev B
4-2005
Vr +18V 0V D.U.T. 30µH diF /dt Adjust
APT10035LLL
APT60D100LCT(G)
trr/Qrr Waveform
PEARSON 2878 CURRENT TRANSFORMER
Figure 9. Diode Test Circuit
1 2 3 4
IF - Forward Conduction Current diF /dt - Rate of Diode Current Change Through Zero Crossing. IRRM - Maximum Reverse Recovery Current. Zero
1
4
5 3 2
trr - Reverse Recovery Time, measured from zero crossing where diode current goes from positive to negative, to the point at which the straight line through IRRM and 0.25 IRRM passes through zero. Qrr - Area Under the Curve Defined by IRRM and trr.
0.25 IRRM
5
Figure 10, Diode Reverse Recovery Waveform and Definitions
TO-264 (LCT) Package Outline
e1 SAC: Tin, Silver, Copper
4.60 (.181) 5.21 (.205) 1.80 (.071) 2.01 (.079)
19.51 (.768) 20.50 (.807) 3.10 (.122) 3.48 (.137) 5.79 (.228) 6.20 (.244)
Common Cathode
25.48 (1.003) 26.49 (1.043)
2.29 (.090) 2.69 (.106) 19.81 (.780) 21.39 (.842)
2.29 (.090) 2.69 (.106)
4-2005
Anode 1 Common Cathode Anode 2
053-0015 Rev B
0.48 (.019) 0.84 (.033) 2.59 (.102) 3.00 (.118)
0.76 (.030) 1.30 (.051) 2.79 (.110) 3.18 (.125) 5.45 (.215) BSC 2-Plcs.
Dimensions in Millimeters and (Inches)
APT’s products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved.