APTDF100H20 数据手册
APTDF100H20 Fast Diode Rectifier Bridge Power Module + AC1 AC2 VRRM = 200V IC = 100A @ Tc = 80°C Applicatio n • • • • Uninterruptible Power Supply (UPS) Induction heating Welding equipment High speed rectifiers Features • • • • • • • • Benefits AC2 - Ultra fast recovery times Soft recovery characteristics Very low stray inductance High blocking voltage High current Low leakage current Very low stray inductance - Symmetrical design - Lead frames for power connections High level of integration • • • • • • + - AC1 Outstanding performance at high frequency operation Low losses Low noise switching Solderable terminals for easy PCB mounting Direct mounting to heatsink (isolated package) Low junction to case thermal resistance Absolute maximum ratings Symbol VR VRRM IF(A V) IF(RMS) IFSM Parameter Maximum DC reverse Voltage Maximum Peak Repetitive Reverse Voltage Maximum Average Forward Duty cycle = 50% Current RMS Forward Current Duty cycle = 50% Non-Repetitive Forward Surge Current 8.3ms Max ratings 200 TC = 25°C TC = 80°C TC = 45°C TC = 45°C 145 100 145 500 Unit V A These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed. APT website – http://www.advancedpower.com 1-4 APTDF100H20 – Rev 0 May, 2005 APTDF100H20 All ratings @ Tj = 25°C unless otherwise specified Electrical Characteristics Symbol Characteristic VF IRM CT Diode Forward Voltage Maximum Reverse Leakage Current Junction Capacitance Test Conditions IF = 100A IF = 200A IF = 100A Tj = 125°C Tj = 25°C VR = 200V Tj = 125°C VR = 200V Min Typ 1.0 1.4 0.9 Max 1.1 Unit V 250 500 400 µA pF Dynamic Characteristics Symbol Characteristic trr trr Qrr IRRM trr Qrr IRRM Reverse Recovery Time Reverse Recovery Time Reverse Recovery Charge Reverse Recovery Current Reverse Recovery Time Reverse Recovery Charge Reverse Recovery Current Test Conditions IF=1A,VR=30V di/dt = 100A/µs Tj = 25°C Tj = 25°C Tj = 125°C Tj = 25°C Tj = 125°C Tj = 25°C Tj = 125°C IF = 100A VR = 133V di/dt=1000A/µs Tj = 125°C Min Typ 39 60 110 200 840 6 15 80 1.91 44 Max Unit ns ns nC A ns µC A IF = 100A VR = 133V di/dt = 200A/µs Thermal and package characteristics Symbol RthJC VISOL TJ TSTG TC Torque Wt Characteristic Junction to Case RMS Isolation Voltage, any terminal to case t =1 min, I isol
APTDF100H20 价格&库存

很抱歉,暂时无法提供与“APTDF100H20”相匹配的价格&库存,您可以联系我们找货

免费人工找货