0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
716FX2-ST

716FX2-ST

  • 厂商:

    ADVANTECH(研华)

  • 封装:

  • 描述:

    NETWORK SWITCH-MANAGED 16 PORT

  • 数据手册
  • 价格&库存
716FX2-ST 数据手册
THE INDUSTRIAL NETWORK COMPANY The N-TRON® 716FX2 Industrial Ethernet switch combines outstanding performance and ease of use. It is ideally suited for connecting Ethernet enabled industrial and/or security equipment and is a fully managed switch. PRODUCT FEATURES • Fourteen 10/100BaseTX RJ-45 Ports • Two 100BaseFX Fiber ports, ST or SC style • -40oC to 70oC Operating temperature • ESD and Surge Protection Diodes on all Ports • Auto Sensing 10/100BaseTX, Duplex, and MDIX • Store-and-forward Technology • Rugged DIN-Rail Enclosure • Redundant Power Inputs (10-30VDC) • Configurable Alarm Contact & Bi-Color Fault Status LED Fully Managed Features: • • • • • • • • SNMP v1, v2, v3 and Web Browser Management Detailed Ring Map and Fault Location Charting N-Ring™ Technology with ~30ms Healing N-View™ OPC Monitoring N-Link™ Redundant N-Ring Coupling Plug-and-play IGMP Support 802.1Q tag VLAN and Port VLAN 802.1p QoS and Port QoS • EtherNet/IP™ CIP Messaging • LLDP (Link Layer Discovery Protocol) • • • • Port Trunking Port Mirroring 802.1d, 802.1w, 802.1D RSTP DHCP Server, Option 82 relay, Option 61 Management Features The 716FX2 offers several management functions that can be easily configured using a web browser. IGMP Snooping - Internet Group Management Protocol allows the 716FX2 switch to forward and filter multicast traffic intelligently. VLAN - Virtual Local Area Network allows you to segment the switch in order to create two or more separate local area network domains. QoS - Quality of Service provides prioritization of network traffic in order to provide better network service. QoS improves the latency of prioritized Ethernet packets required for ring management, real-time, and other interactive applications. Port Trunking - Trunking (link aggregation) enables multiple physical ports to be linked together and function as one uplink to another N-TRON trunking capable switch configured in the same manner, thereby increasing the bandwidth between switches. This configuration can provide increased bandwidth and redundancy to applications requiring high levels of fault tolerant operation. Port Mirroring - Allows the traffic on one port to be duplicated and sent to a designated mirror port. Port mirroring is used to monitor Ethernet traffic on the designated source port using the assigned mirror port. DHCP - DHCP Server / Client automates the assignment of IP addresses. DHCP Option 82 assures that if a device on a specific port is replaced, the replacement receives the same IP address as the original device. Rapid Spanning Tree Protocol RSTP allows the switch to be configured in a ring or mesh topology, and provides support for redundant path communications with high speed (rapid) healing. Remote Monitoring Options For ease of configuration and monitoring, the 716FX2 offers web browser management and N-View OLE for Process Control (OPC) server software. The N-TRON N-View software can be combined with popular HMI software packages to add network traffic monitoring, trending, and alarming to any application using N-TRON switches. SNMP is also available for switch link and status monitoring. The alarm contact and status LED can be configured to respond to power failure on power input 1 or input 2, N-Ring Broken, Partial Break High, Partial Break Low, or if multiple Ring managers are detected. N-Ring Technology N-TRON's 716FX2 Ring Manager using N-TRON's N-Ring technology offers expanded ring size capacity, detailed fault diagnostics, and a standard healing time of ~30ms. The 716FX2 ring manager periodically checks the health of the ring via packets. If the ring manager stops receiving these health check packets, it converts the ring to a linear topology within ~30ms. When all switches in the ring are N-TRON fully managed switches, a detailed ring map and fault location chart will also be provided on the ring manager’s web browser and OPC server to identfy the health status of the ring. N-Link™ allows the linking of two N-Rings. Up to 250 fully managed N-TRON switches can participate in N-Ring topologies. Industrial Packaging and Specifications The 716FX2 is designed to operate in industrial environments. It is housed in a rugged steel DIN-Rail enclosure. It has extended industrial specifications and features to meet or exceed the operating parameters of the connected equipment. These include extended temperature ratings, extended shock and vibration specs, redundant power inputs, and high MTBF (greater than 2M hours). Ease of Use The 10/100BaseTX ports are auto sensing and auto configuring. Each copper port is automatically negotiated for maximum speed and performance by default, but can also be hard coded through the user interface. A high speed processor allows wire speed capability on all 100BaseTX ports simultaneously. THE INDUSTRIAL NETWORK COMPANY 716FX2 Industrial Ethernet Switch Ordering Information 716FX2-XX 716FXE2-XX-YY 700-PM URMK NTPS-24-1.3 Fourteen 10/100BaseTX Ports, Two Multimode 100BaseFX Fiber Optic Ports Fourteen 10/100BaseTX Ports, Two Singlemode 100BaseFX Fiber Optic Ports Panel Mount kit Universal Rack Mount Kit N-TRON Power Supply - (1.3 Amp @ 24VDC) Where: XX = ST or SC E = Singlemode, and Blank Otherwise YY = 15, 40 or 80 for Singlemode, Blank for Multimode 716FX2 Specifications Switch Properties Number of MAC Addresses: Aging Time: Latency Typical: Switching Method: 100 Mb Fiber Transceiver Characteristics 8000 Programmable 2.6 μs Store-and-Forward 2.3" 8.3" 4,8" 3.3 lbs 35mm Electrical Redundant Input Voltage: Input Current (max): N-TRON Power Supply: 10-30 VDC (Regulated) 620mA max. @ 24VDC NTPS-24-1.3 (1.3A@24V) Operating Altitude: 2km* 15km** 40km** TX Power Min -19dBm/-14dBm -15dBm/-7dBm -5dBm/0dBm 80km** -5dBm/0dBm RX Sensitivity Max -32dBm -34dBm -34dBm -34dBm Wavelength 1310nm 1310nm 1310nm 1550nm * Multimode Fiber Optic Cable ** Singlemode Fiber Optic Cable Case Dimensions Height: Width: Depth: Weight (max) DIN-Rail Mount: Environmental Operating Temperature: Storage Temperature: Operating Humidity: Fiber Length (5.8 cm) (21.0 cm) (12.1 cm) (1.5 kg) Connectors 10/100BaseTX: 100BaseFX: Fourteen (14) RJ-45 Copper Ports Two (2) SC or ST Fiber Duplex Ports Recommended Wiring Clearance Front: Side: 4" 1" (10.16 cm) (2.54 cm) Regulatory Approvals -40oC to 70oC -40oC to 85oC 5% to 95% (Non Condensing) 0 to 10,000 ft. Shock and Vibration (bulkhead mounted) Shock: 200g @ 10ms Vibration/Seismic: 50g, 5-200Hz, Triaxial Reliability MTBF: >2 Million Hours Network Media 10BaseT: 100BaseTX: 100BaseFX Multimode: 100BaseFXE Singlemode: >Cat3 Cable >Cat5 Cable 50-62.5/125μm 7-10/125μm FCC Title 47, Part 15, Subpart B - Class A; ICES-003 - Class A UL Listed (US and Canada) 1604; ANSI/ISA-12.12.01-2007 Class I, Div 2, Groups A, B, C, D, and T4A CE: EN61000-6-2:2001: EN61000-4-2, 3, 4, 5, 6 EN55011:1998+A1:1999+A2:2002-Class A EN50155 for Railway applications GOST-R Certified, RoHS Compliant Designed to comply with: IEEE 1613 for Electric Utility Substations NEMA TS1/ TS2 for Traffic control Contact Information N-TRON Corp. 820 S. University Blvd., Suite 4E Mobile, AL 36609 USA TEL: (251) 342-2164 FAX: (251) 342-6353 Website: www.n-tron.com Email: N-TRON_info@n-tron.com N-TRON Europe GmbH Alte Steinhauserstr 19 6330 Cham / Zg Switzerland TEL: +41 41 7406636 FAX: +41 41 7406637 REV 090806 ® 2009 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identification purposes only and may be trademarks and/or registered trademarks of their respective company. Specifications subject to change without notice. The responsibility for the use and application of N-TRON products rests with the end user. N-TRON makes no warranties as to the fitness or suitability of any N-TRON product for any specific application. N-TRON Corporation shall not be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA. THE INDUSTRIAL NETWORK COMPANY 716FX2 Drawings on N-TRON Tech Docs Page ® 2009 N-TRON Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifications subject to change without notice. Printed in USA.
716FX2-ST 价格&库存

很抱歉,暂时无法提供与“716FX2-ST”相匹配的价格&库存,您可以联系我们找货

免费人工找货