THE INDUSTRIAL NETWORK COMPANY
The N-TRON® 716FX2 Industrial Ethernet switch combines
outstanding performance and ease of use. It is ideally suited for
connecting Ethernet enabled industrial and/or security equipment
and is a fully managed switch.
PRODUCT FEATURES
• Fourteen 10/100BaseTX RJ-45 Ports
• Two 100BaseFX Fiber ports, ST or SC style
• -40oC to 70oC Operating temperature
• ESD and Surge Protection Diodes on all Ports
• Auto Sensing 10/100BaseTX, Duplex, and MDIX
• Store-and-forward Technology
• Rugged DIN-Rail Enclosure
• Redundant Power Inputs (10-30VDC)
• Configurable Alarm Contact & Bi-Color Fault Status LED
Fully Managed Features:
•
•
•
•
•
•
•
•
SNMP v1, v2, v3 and Web Browser Management
Detailed Ring Map and Fault Location Charting
N-Ring™ Technology with ~30ms Healing
N-View™ OPC Monitoring
N-Link™ Redundant N-Ring Coupling
Plug-and-play IGMP Support
802.1Q tag VLAN and Port VLAN
802.1p QoS and Port QoS
• EtherNet/IP™ CIP Messaging
• LLDP (Link Layer Discovery Protocol)
•
•
•
•
Port Trunking
Port Mirroring
802.1d, 802.1w, 802.1D RSTP
DHCP Server, Option 82 relay, Option 61
Management Features
The 716FX2 offers several management functions that can be
easily configured using a web browser.
IGMP Snooping - Internet Group Management Protocol allows the
716FX2 switch to forward and filter multicast traffic intelligently.
VLAN - Virtual Local Area Network allows you to segment the switch
in order to create two or more separate local area network domains.
QoS - Quality of Service provides prioritization of
network traffic in order to provide better network service. QoS
improves the latency of prioritized Ethernet packets required for
ring management, real-time, and other interactive applications.
Port Trunking - Trunking (link aggregation) enables multiple
physical ports to be linked together and function as one uplink to
another N-TRON trunking capable switch configured in the same
manner, thereby increasing the bandwidth between switches. This
configuration can provide increased bandwidth and redundancy
to applications requiring high levels of fault tolerant operation.
Port Mirroring - Allows the traffic on one port to be duplicated
and sent to a designated mirror port. Port mirroring is used to
monitor Ethernet traffic on the designated source port using the
assigned mirror port.
DHCP - DHCP Server / Client automates the assignment of IP
addresses. DHCP Option 82 assures that if a device on a
specific port is replaced, the replacement receives the same
IP address as the original device.
Rapid Spanning Tree Protocol
RSTP allows the switch to be configured in a ring or mesh topology,
and provides support for redundant path communications with high
speed (rapid) healing.
Remote Monitoring Options
For ease of configuration and monitoring, the 716FX2 offers web
browser management and N-View OLE for Process Control (OPC)
server software. The N-TRON N-View software can be combined with
popular HMI software packages to add network traffic monitoring,
trending, and alarming to any application using N-TRON switches.
SNMP is also available for switch link and status monitoring. The alarm
contact and status LED can be configured to respond to power failure on
power input 1 or input 2, N-Ring Broken, Partial Break High, Partial
Break Low, or if multiple Ring managers are detected.
N-Ring Technology
N-TRON's 716FX2 Ring Manager using N-TRON's N-Ring
technology offers expanded ring size capacity, detailed fault
diagnostics, and a standard healing time of ~30ms. The 716FX2 ring
manager periodically checks the health of the ring via packets. If the
ring manager stops receiving these health check packets, it converts
the ring to a linear topology within ~30ms. When all switches in
the ring are N-TRON fully managed switches, a detailed ring map
and fault location chart will also be provided on the ring manager’s
web browser and OPC server to identfy the health status of the
ring. N-Link™ allows the linking of two N-Rings. Up to 250 fully
managed N-TRON switches can participate in N-Ring topologies.
Industrial Packaging and Specifications
The 716FX2 is designed to operate in industrial environments. It
is housed in a rugged steel DIN-Rail enclosure. It has extended
industrial specifications and features to meet or exceed the
operating parameters of the connected equipment. These include
extended temperature ratings, extended shock and vibration specs,
redundant power inputs, and high MTBF (greater than 2M hours).
Ease of Use
The 10/100BaseTX ports are auto sensing and auto configuring.
Each copper port is automatically negotiated for maximum speed
and performance by default, but can also be hard coded through the
user interface. A high speed processor allows wire speed capability
on all 100BaseTX ports simultaneously.
THE INDUSTRIAL NETWORK COMPANY
716FX2 Industrial Ethernet Switch Ordering Information
716FX2-XX
716FXE2-XX-YY
700-PM
URMK
NTPS-24-1.3
Fourteen 10/100BaseTX Ports, Two Multimode 100BaseFX Fiber Optic Ports
Fourteen 10/100BaseTX Ports, Two Singlemode 100BaseFX Fiber Optic Ports
Panel Mount kit
Universal Rack Mount Kit
N-TRON Power Supply - (1.3 Amp @ 24VDC)
Where: XX = ST or SC
E = Singlemode, and Blank Otherwise
YY = 15, 40 or 80 for Singlemode, Blank for Multimode
716FX2 Specifications
Switch Properties
Number of MAC Addresses:
Aging Time:
Latency Typical:
Switching Method:
100 Mb Fiber Transceiver Characteristics
8000
Programmable
2.6 μs
Store-and-Forward
2.3"
8.3"
4,8"
3.3 lbs
35mm
Electrical
Redundant Input Voltage:
Input Current (max):
N-TRON Power Supply:
10-30 VDC (Regulated)
620mA max. @ 24VDC
NTPS-24-1.3 (1.3A@24V)
Operating Altitude:
2km*
15km**
40km**
TX Power Min
-19dBm/-14dBm
-15dBm/-7dBm
-5dBm/0dBm
80km**
-5dBm/0dBm
RX Sensitivity Max
-32dBm
-34dBm
-34dBm
-34dBm
Wavelength
1310nm
1310nm
1310nm
1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Case Dimensions
Height:
Width:
Depth:
Weight (max)
DIN-Rail Mount:
Environmental
Operating Temperature:
Storage Temperature:
Operating Humidity:
Fiber Length
(5.8 cm)
(21.0 cm)
(12.1 cm)
(1.5 kg)
Connectors
10/100BaseTX:
100BaseFX:
Fourteen (14) RJ-45 Copper Ports
Two (2) SC or ST Fiber Duplex Ports
Recommended Wiring Clearance
Front:
Side:
4"
1"
(10.16 cm)
(2.54 cm)
Regulatory Approvals
-40oC to 70oC
-40oC to 85oC
5% to 95%
(Non Condensing)
0 to 10,000 ft.
Shock and Vibration (bulkhead mounted)
Shock:
200g @ 10ms
Vibration/Seismic:
50g, 5-200Hz, Triaxial
Reliability
MTBF:
>2 Million Hours
Network Media
10BaseT:
100BaseTX:
100BaseFX Multimode:
100BaseFXE Singlemode:
>Cat3 Cable
>Cat5 Cable
50-62.5/125μm
7-10/125μm
FCC Title 47, Part 15, Subpart B - Class A; ICES-003 - Class A
UL Listed (US and Canada) 1604; ANSI/ISA-12.12.01-2007
Class I, Div 2, Groups A, B, C, D, and T4A
CE: EN61000-6-2:2001: EN61000-4-2, 3, 4, 5, 6
EN55011:1998+A1:1999+A2:2002-Class A
EN50155 for Railway applications
GOST-R Certified, RoHS Compliant
Designed to comply with:
IEEE 1613 for Electric Utility Substations
NEMA TS1/ TS2 for Traffic control
Contact Information
N-TRON Corp.
820 S. University Blvd., Suite 4E
Mobile, AL 36609 USA
TEL: (251) 342-2164
FAX: (251) 342-6353
Website: www.n-tron.com
Email: N-TRON_info@n-tron.com
N-TRON Europe GmbH
Alte Steinhauserstr 19
6330 Cham / Zg Switzerland
TEL: +41 41 7406636
FAX: +41 41 7406637
REV 090806
® 2009 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identification purposes only and
may be trademarks and/or registered trademarks of their respective company. Specifications subject to change without notice. The responsibility for the use and application
of N-TRON products rests with the end user. N-TRON makes no warranties as to the fitness or suitability of any N-TRON product for any specific application. N-TRON Corporation
shall not be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA.
THE INDUSTRIAL NETWORK COMPANY
716FX2 Drawings on N-TRON Tech Docs Page
® 2009 N-TRON Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifications subject to change without notice. Printed in USA.