Split-core Current Transducers/Sensors
Models BB-JC10F50-V, BB-JC24S250-V, BB-JC36S500-V
www.advantech-bb.com
BB-JC10F50-V
+ All-in one structure in a small size
+ Connect directly to PLCs
+ Sense motor stalls and short circuits
+ Industrial instrumentation
+ Process control loops
+ Phased fired-controlled heaters
+ UL, CSA, CE and RoHS available
ORDERING INFORMATION
OVERVIEW
These split-core current transducers are designed for energy
management with a convenient connection to electronic submetering. They may also be applied for current measurement
in a system of distributed power line carriers (PLCs) or remote
controls such as SCADA software for automation and supervision.
Other applications include security and condition monitoring, load
monitoring, protection systems, and predictive maintenance of
conveyors, pumps, HVAC motors and more.
LOAD TREND MONITOR PER DISTRIBUTION PANEL
When a sensor outputting analog instrumentation signals in proportion
to load current, is clamped directly onto the main or branch wiring
of the distribution panel, direct input into analog port as PLC or data
logger becomes available without a converter in the middle.
CURRENT RANGE
(50/60 HZ)
OUTPUT
IMPEDANCE
BB-JC10F50-V
50 Arms
6.2K Ω
45g
BB-JC24S250-V
250 Arms
5.8K Ω
200g
BB-JC36S500-V
500 Arms
5.8K Ω
290g
MODEL NUMBER
WEIGHT
SPECIFICATIONS – All Models
TECHNOLOGY
Output Voltage
0~5V DC (average) / 0 ~ rated current, 7.5V DC limiter built-in
Maximum
Allowable Current
100% (continuous) 150% (1 min.)
Accuracy/Linearity
± 2% FS.dynamic range 1:100 (50/60 Hz sinewave)
Output Ripple
Voltage
Within 5% of output voltage
Response Time
300 ms
Insulation
Resistance
DC500V / 100M Ω or more (between core and output terminals)
Dielectric Strength
AC 2000V / 1 min. (between core and output terminals)
MECHANICAL
Sensing Aperture
10mm (clamp-on type)
Latch/Unlatch
About 150 times
Output Terminals
2 x M3-screw with terminal covers
Tightening Torque
0.3 Nm
ENVIRONMENTAL
Operating
Conditions
-20 ~ +50 °C, ≤85% RH, No condensation, In-house & any
direction installable
Storage Conditions
-30 ~ +90 °C, ≤85% RH, No condensation
All product specifications are subject to change without notice.
BB-JCxFx-V_CurrentSensors_3718ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
Split-core Current Transducers/Sensors
Models BB-JC10F50-V, BB-JC24S250-V, BB-JC36S500-V
BB-JC24S250-V
DIMENSIONS – BB-JC10F50-V
Unit = mm
0-V
4S
25
JC
2
JC10F5
0-V
OUTPUT VOLTAGE DATA
CONNECTING THE LEAD WIRE
J
-V
500
6S
C3
DIMENSIONS – BB-JC24S250-V
Unit = mm
34
22
45
24
74.5
52
DIMENSIONS – BB-JC36S500-V
Unit = mm
40.5
22
57
36
91
62
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
很抱歉,暂时无法提供与“BB-JC36S500-V”相匹配的价格&库存,您可以联系我们找货
免费人工找货