THE INDUSTRIAL NETWORK COMPANY
The N-TRON ® 702M12-W Industrial Wireless Radio offers
outstanding performance and ease of use. It is ideally suited for
connecting wireless devices to a wired network or for connecting
two wired networks in an IP67 environment, where it is not possible,
impractical, or too expensive to install cable.
Product Features
•
•
•
•
•
•
•
•
•
•
•
Full IEEE 802.11a,b,g,n Compliance
IP67 Rated, Industrial Hardened Enclosure
One 10/100BaseTX M12 Port
Three Antennas for 3x3 MIMO Operations
Four user definable LED's for display of signal quality
Radio Enable, Link/Activity, and power LEDs
802.3af PoE Powered Device
Extended Environmental Specifications
Autosensing 10/100BaseTX, Duplex, and MDIX
Redundant Power Inputs (20-49 VDC)
Web Browser Management
Wireless Compliance:
• IEEE 802.11a/b/g/n Compliant
Security:
• 802.11i with AES-CCM & TKIP Encryption
• 802.1x, 64/128 bit WEP
Data Rates:
• Legacy 802.11a/b/g (1-54Mbps),
• 802.11n (up to 300Mbps)
Range Performance:
• Indoor (Antenna Dependent) greater than 300m
• Outdoor (Antenna Dependent) greater than 60km
Applications
In industrial environments, the installation of fiber or Cat5e cable
and associated power cables is difficult or cost prohibitive. There
are also applications which require communication with mobile
devices such as laptop computers, forklifts, cockpits or control
centers on mobile equipment such as cranes, and other devices
which are impossible to connect with copper or fiber cable. The
N-TRON 702M12-W provides a wireless connection that can
be quickly and easily deployed. With it's wide operating
temperature range and 1 million hours MTBF, the 702M12-W
offers the industrial ruggedness that customers have come to
expect of N-TRON products. The IP67 sealed enclosure insures
that outdoor, wash down, and the most dusty environments will
present no problems to the 702M12-W. Three antennas enable the
use of Multiple-In, Multiple-Out (MIMO) technology for increased
throughput. Power over Ethernet (PoE) technology allows the
702M12-W to receive power through the Cat5e cable from a PoE
sourcing device, such as the N-TRON 105TX-POE Switch. This
eliminates the need for power cables or power supplies for the
702M12-W. Using wireless and PoE technology makes temporary
deployment of network nodes much easier because only one Cat5e
cable is required.
Industrial Packaging and Specifications
The 702M12-W is specifically designed to operate in industrial
environments. With it's rugged enclosure and industrial specifications
such as extended shock and vibrations specs plus redundant power
inputs, the 702M12-W easily meets and exceeds the operating
parameters of the connected equipment.
Multiple Wireless Modes
The 702M12-W provides a number of configuration options that
allow it to be customized to suit specific application requirements.
Station: In "station" configuration the 702M12-W is used to connect
a single device (MAC Address) to a wireless access point.
Station, WDS (Wireless Distribution System): In "station, WDS"
mode the 702M12-W can be connected to a remote wired switch
and will allow multiple devices (MAC Address forwarding) to be
connected to the wireless access point with WDS activated.
Access Point: The "Access Point" mode allows the 702M12-W to
serve as a wireless switch for the attached wireless stations. Wireless
access points are commonly used to create one wireless local area
network (WLAN) that spans an area around the Access Point. Each
access point typically supports up to 253 stations.
Access Point, WDS (Wireless Distribution System): The
702M12-W in "Access Point, WDS" mode allows wireless
connection of a number of access points to extend the coverage of
the wireless network. The main base Access Point in WDS mode
is extended using a series of relay Access points in WDS mode
(Extended Service Set) and can in turn form a WLAN consisting of
thousands of stations. All stations should be configured in "Station
WDS" mode. Correctly configured switches using WDS will create
a single network, providing station mobility throughout the wireless
network.
Multiple Network Modes
Bridge: In this mode the 702M12-W will operate in Layer two
without network segmentation.
Router: Router operating mode offers Layer three routing to allow
network segmentation.
THE INDUSTRIAL NETWORK COMPANY
Scenario 1 – Basic Bridge
Access Point:
The "Access Point" mode
a l l o w s t h e 702M12-W
to serve as a wireless
switch for the wireless
stations attached to it.
Station:
In "station" configuration
the 702M12-W is used to
connect a single device
(MAC Address) to a
wireless access point.
For added security, the 702M12-W supports WEP, WPA™, and WPA2™. WPA and WPA2, TKIP (Temporal Key Integrity
Protocol) and CCMP (Counter Mode with Cipher Block Chaining Message Authentication Code Protocol) are available.
Scenario 2 – Control Network
In Station WDS mode the 702M12-W can be connected to a remote wired Ethernet switch with multiple devices connected
to the switch.
THE INDUSTRIAL NETWORK COMPANY
Scenario 3 – WDS Peering
In this scenairio, each 702M12-W has been configured as a peer of selected other 702M12-W(s) by using the MAC
Addresses of the select unit(s). This allows forklifts or other mobile wireless devices to maintain communication
seamlessly as they move from the area covered by one 702M12-W into the area covered by the next 702M12-W.
Scenario 4 – Broadband Modem Wireless Router (W/ DHCP)
The N-TRON 702M12-W configured as a router can act as a DHCP server and supports the Network Address Translation
(Masquerading) feature which is widely used by Access Points. This automates the assigning of IP addresses to devices as
they connect. NAT will act as a firewall between LAN and WLAN networks. Additional firewall settings can be configured
for layer 3 packet filtering and access control in Router mode.
THE INDUSTRIAL NETWORK COMPANY
702M12-W Specifications
Case Dimensions
Height: (w/o antennas)
Width:
Depth:
Weight (max):
Radio Output Power:
6.7"
6.7"
1.8"
3.5 lbs
(17.2 cm)
(17.2 cm)
(4.6 cm)
(1.6 kg)
Environmental
Operating Temperature:
Storage Temperature:
Operating Humidity:
Operating Altitude:
N-TRON Power Supply:
-40oC to 70oC
-40oC to 85oC
5% to 100%
(Non Condensing)
0 to 10,000 ft.
NTPS-24-1.3
Electrical
Redundant Input Voltage:
Input Current (max):
702M12-W Max Power:
Input Ripple:
20-49 VDC (Regulated)
200mA max @24 VDC
4.8Watts max
Less than 100mV
Reliability
MTBF:
>1 Million Hours
Network Media
10BaseT:
100BaseTX:
802.11abgn:
>Cat3 Cable
>Cat5 Cable
Air
Connectors
10/100BaseTX:
802.11abgn
One (1) M12 Copper Port
PoE Powered device support
(3) RP-TNC connectors
Recommended Wiring Clearance (Antenna Dependent)
Front:
Side:
Top:
4" (10.16cm)
4" (10.16cm)
6" (15.24cm)
Contact Information
N-TRON Corp.
820 S. University Blvd., Suite 4E
Mobile, AL 36609 USA
TEL: (251) 342-2164
FAX: (251) 342-6353
Website: www.N-TRON.com
Email: N-TRON_info@N-TRON.com
Radio Receiver Sensitivity
Up to 250mW US
802.11a
DataRate
1-24Mbps
36Mbps
48Mbps
54Mbps
5GHz
Avg TX ±2dB
24 dBm
22 dBm
20 dBm
19 dBm
802.11a
DataRate
1-24Mbps
36Mbps
48Mbps
54Mbps
5GHz
Sens. ±3dB
-96 dBm
-95 dBm
-94 dBm
-91 dBm
802.11b/g
DataRate
1-24Mbps
36Mbps
48Mbps
54Mbps
2.4GHz
Avg TX ±2dB
24 dBm
22 dBm
20 dBm
19 dBm
802.11b/g
DataRate
1-24Mbps
36Mbps
48Mbps
54Mbps
2.4GHz
Sens. ±3dB
-97 dBm
-90 dBm
-86 dBm
-84 dBm
802.11n
DataRate
MCS0
MCS1
MCS2
MCS3
MCS4
MCS5
MCS6
MCS7
MCS8
MCS9
MCS10
MCS11
MCS12
MCS13
MCS14
MCS15
2.4GHz
5GHz
Avg TX ±2dB
24dBm
24dBm
24dBm
24dBm
24dBm
24dBm
22dBm
22dBm
22dBm
22dBm
22dBm
22dBm
18dBm
18dBm
15dBm
15dBm
24dBm
24dBm
24dBm
24dBm
22dBm
22dBm
20dBm
20dBm
20dBm
20dBm
17dBm
17dBm
17dBm
17dBm
15dBm
15dBm
802.11n
DataRate
MCS0
MCS1
MCS2
MCS3
MCS4
MCS5
MCS6
MCS7
MCS8
MCS9
MCS10
MCS11
MCS12
MCS13
MCS14
MCS15
2.4GHz 5GHz
Sens. ±3dB
-97dBm -96dBm
-96dBm -95dBm
-93dBm -92dBm
-91dBm -90dBm
-87dBm -86dBm
-84dBm -83dBm
-78dBm -77dBm
-75dBm -74dBm
-96dBm -95dBm
-94dBm -93dBm
-91dBm -90dBm
-88dBm -87dBm
-85dBm -84dBm
-80dBm -79dBm
-79dBm -78dBm
-76dBm -75dBm
Regulatory Approvals
UL /cUL Class I, Div 2, Groups A, B, C, D, and T4A
ANSI/ISA-12.12.01-2007 and UL 508 and 1604
FCC/CE (CFR 47, Part 15, Subpart B - Class A),
EN 301 489-3, IEC 6100-4-2, 6100-4-3,
R&TTE Directive 99/5/EC, ANSI C63.4, and ICES-003 Issue 3
GOST-R Certified, RoHS Compliant,
Designed to comply with:
IEEE 1613 for Electric Utility Substations
NEMA TS1/ TS2 for Traffic control
N-TRON Asia
Suite #: 2267, 22/F, One Lujiazui
68 Yin Cheng Road Center,
Pudong New Area
200120 Shanghai, P.R. China
Phone: +86 (0) 21 6194 6777
Fax: +86 (0) 21 6194 6699
N-TRON Europe GmbH
Alte Steinhauserstr 19
6330 Cham / Zg Switzerland
TEL: +41 41 7406636
FAX: +41 41 7406637
REV 100924
® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identification purposes only and
may be trademarks and/or registered trademarks of their respective company. Specifications subject to change without notice. The responsibility for the use and application
of N-TRON products rests with the end user. N-TRON makes no warranties as to the fitness or suitability of any N-TRON product for any specific application. N-TRON Corporation
shall not be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA.
THE INDUSTRIAL NETWORK COMPANY
702M12-W WIRELESS ETHERNET RADIO
Cables with M12 connectors
Ordering Information
Ordering Information
702M12-W
Industrial Wireless Radio
CAT5E-M12-M12-X
Straight M12 to Str. M12, Shielded
702M12-PK
Pole mount kit for 702M12-W
CAT5E-M12-RJ45-X
Straight M12 to RJ-45, Shielded
ANT-CAB-400-N-RPTNC-X
Low Loss Coaxial Antenna cable
1 RP-TNC and 1 N Male connector
CAT5E-M12-X
Straight M12 to bare end, Shielded
ANT-MD24-12
2.4GHz 12dBi Mini Directional Antenna
CAT5E-RM12-M12-X
90º M12 to Str. M12, Shielded
ANT-PAD24-16
2.4GHz 16dBi Directional Antenna
CAT5E-RM12-RM12-X 90º M12 to 90º M12, Shielded
ANT-PAD58-19
5.8GHz 19dBi Directional Antenna
CAT5E-RM12-RJ45-X 90º M12 to RJ-45, Shielded
ANT-PD58-32
5.8 GHz Parabolic Dish 32dBi
Directional Antenna
CAT5E-RM12-X
ANT-LA6-NFF
2-6GHz quarter wave lightning arrestor PWR-M12-A-X
(N-female to N-female, less than 0.2dB
insertion loss, IP65, -40 to 85°C)
Power Cable, M12 A-Coded Straight
Female to bare end, Shielded
ANT-CAB-400-N-X
Low loss CA-400 coaxial cable with
(2) N Female connectors for use with the
ANT-LA6-NFF lightning arrestor
PWR-RM12-A-X
Power Cable, M12 A-Coded
90º Female to bare end, Shielded
M12DRC-ISO
DIN-Rail kit, two isolated plastic clips
M12DRC-MTL
DIN-Rail kit, two metal clips
Where:X = length of cable, fill in desired amount in feet.
Example: CAT5E-RM12-10 (for a 10ft cable)
NTPS-24-1.3
DIN-Rail Power Supply 24V@1.3 Amp
90º M12 to bare end, Shielded
® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifications subject to change without notice. Printed in USA.