Click on Series name for product info on aimtec.com
Series AM2L-NZ
Not Recommended For New Design
2 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
•
•
Low Profile SMD
1000VDC & 6000VDC Isolation
Industry Standard Pinout
Unregulated Single & Dual Outputs
MTBF>1,000,000 hours
Operating temperature: -40°C to +85°C
High Efficiency up to 85%
Models
Single output
Model
Input Voltage
(V)
AM2L-0505SH60-NZ
AM2L-1205SH60-NZ ※
AM2L-1215SH60-NZ ※
AM2L-2405SH60-NZ ※
Output
Voltage (V)
4.5-5.5
10.8-13.2
10.8-13.2
21.6-26.4
Output Current
max(mA)
5
5
15
5
400
400
133
400
Isolation
(VDC)
Efficiency
(%)
6000
6000
6000
6000
77
78
81
79
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity1000
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit Restart
Line voltage regulation
Load voltage regulation (5 Vout)
Load voltage regulation (12 Vout)
Load voltage regulation (15 Vout)
Temperature coefficient
Ripple & Noise*
Minimum Load Current**
Conditions
Typical
See Tolerance Graph
6000VDC Continuous
Maximum
Units
1
%
Sec
±5
For a 1% change of Vin
From 10% load to 100% load
At 100% load
20MHz Bandwidth
Auto-Recovery
±1.2
12.8
6.8
6.3
±0.03
150
10
%
%
%/oC
mV p-p
% of Max
*Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available on Aimtec’s website www.aimtec.com
**If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
www.aimtec.com
F 051e R12.S
REV: 05/20/A
Conditions
Typical
100% load, nominal input
100
Maximum
Units
100
KHz
oC
oC
oC
-40 to + 85
-55 to + 125
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM2L-NZ
Not Recommended For New Design
2 Watt | DC-DC Converter
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
Free Air Convection
95
% RH
Plastic(UL94-V0)
6000VDC
3.8
g
Single 6000VDC
0.94 x 0.79 x 0.32 inches 23.86 x 18.50 x 8.00mm
>1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC)
oC
1.5mm from case for 10 seconds
260
Safety Specifications
Parameters
Agency approvals
CE
EN 60601-1-1; EN 60601-1-2
Standards
Pin Out Specifications
Pin
Single
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
- V in
No Pin
No Pin
No Pin
No Pin
No Pin
NC
NC
+V out
-V out
No Pin
No Pin
No Pin
No Pin
No Pin
+V in
Typical Voltage Accuracy Characteristics
Tolerance Envelope Graph
+10%
Typical Load Line
+5%
+2.5%
Output Voltage
-2.5%
10%
-7.5%
50%
Output Current(%)
100%
NOTE: On dual output models Pin 5 and Pin 10 are connected internally together.
Either Pin 5 or Pin 10, or both can be used as the -Vout
NC: not connected
Dimensions
Side View
23.86
(0.94)
Front View
8.00 7.50
(0.32) (0.30)
A
3.04
(0.12)
13.10
(0.52)
2.54
(0.10)
2.00
(0.08)
Top View
1.00
(0.04)
16
18.50
(0.73)
A
10
9
0.50
(0.01)
18.50 13.70
(0.73) (0.54)
1
7
8
5.00º
angle
1.35 ± 0.13
(0.05 ± 0.005) MAX
15.24
(0.60)
Recommended Filter Circuit
www.aimtec.com
F 051e R12.S
REV: 05/20/A
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Not Recommended For New Design
Series AM2L-NZ
2 Watt | DC-DC Converter
L
Single Output
L
+Vout
+ Vin
+
Cin +
DC
DC
- Vin
Cout
- Vin
If it is required to decrease the input/output ripple an “LC” filter network can be installed on the input and output of the
converter (see above).
It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC
converter switching frequency to avoid mutual interference.
The capacitance of the outputfilter capacitor must not exceed the values in the Table below to avoid startup problems and
ensure safe and reliable operation.
It’s not recommended to connect any external capacitor in the application field whenoutput loading is less than 0.5
watt.
External Capacitor Tables
Input Capacitor (Cin)
Vin
(VDC)
Cin
(uF)
5
12
24
4.7
2.2
1
Output Capacitor (Cout)
Single
Vout
(VDC)
5
15
Cout
(uF)
10
1
Overload Protection
The output circuit of these products has no protection against overload. It is recommended to install external overload
protection in the form of a self-recovery fuse or a circuit breaker in series at the converter’s input.
To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the
AM2LV-NZ series as an alternative.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity
很抱歉,暂时无法提供与“AM2L-0505SH60-NZTR”相匹配的价格&库存,您可以联系我们找货
免费人工找货