Series AM40U-AZ
40 Watt | DC-DC Converter
FEATURES: • • • • Wide Input 2:1 Range Full Internal SMD Technology 1600 VDC Isolation Efficiency up to 89% • • • • Adjustable Output Voltage Remote ON/OFF Function Over Load, Voltage & Short Circuit Protection Operating temperature -40oC to + 85oC
Models Single output
Model
AM40U-1203SAZ AM40U-1205SAZ AM40U-1212SAZ AM40U-1215SAZ AM40U-2403SAZ AM40U-2405SAZ AM40U-2412SAZ AM40U-2415SAZ AM40U-4803SAZ AM40U-4805SAZ AM40U-4812SAZ AM40U-4815SAZ
Input Voltage (V)
9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75
Output Voltage (V)
3.3 5 12 15 3.3 5 12 15 3.3 5 12 15
Output Current max (A)
8 8 3.3 2.6 8 8 3.3 2.6 8 8 3.3 2.6
Isolation (VDC)
1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600
Efficiency (%)
85 86 86 87 86 88 88 89 87 88 89 89
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity1000 220
Rated
1600
Units
VDC MOhm pF
Output Specifications
Parameters
Voltage accuracy Over voltage protection Over load protection Short Circuit protection Short circuit restart Thermal shutdown Line voltage regulation www.aimtec.com
F 051e R12.B
Conditions
Foldback
Typical
±2 Zener Diode Clamp 135~150 Continuous Auto-Restart 110 ±1
Maximum
Units
% %
On Case
ºC % of Vin Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Tel: +1 514 620 2722 1 of 3
Series AM40U-AZ
40 Watt | DC-DC Converter Output Specifications (continued)
Parameters
Load voltage regulation (Single) Temperature coefficient Ripple & Noise Voltage adjustment range
Conditions
Iout=10% to 100% 20MHz Bandwidth
Typical
±2 ±0.02 75 ±10
Maximum
Units
% %/oC mV p-p %
General Specifications
Parameters
Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation
Conditions
100% load With derating above 55 oC (see graph below)
Typical
300 -40 to +85 -55 to +125
Maximum
Units
KHz
o o o
C
Above 55 oC
105 2 Free Air Convection
C C %/ oC % RH g
o
95 Nickel – coated Copper 60 2.00 x 2.00 x 0.40 inches 50.81 x 50.81 10.14 mm >1 500 000 hrs ( MIL-HDBK-217 F at +25 oC) 1.5mm from case for 10 sec 260 500 25% load step ±4% of Vout
C uS
Safety Specifications
Parameters
Standards Designed to meet IEC 60950-1:2001 and EN55022:2006 + A1:2007, Class B
Pin Out Specifications
Pin
1 2 3 4 5 6 Single +V Input -V Input No Pin +V Output -V Output On/Off (option)
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722 2 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM40U-AZ
40 Watt | DC-DC Converter Dimensions
Derating
Free Air Convection
55º C 100 80 60 40 20 0 - 40 - 20 0 20 40 60 80
85
Trimming
Safe Operating Area
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity
很抱歉,暂时无法提供与“AM40U-4815SAZ”相匹配的价格&库存,您可以联系我们找货