Series AM6C-NZ
6 Watt | DC-DC Converter
FEATURES:
• Wide input voltage range (2:1)
• Efficiency up to 88%
• Isolation voltage of 1500VDC
• Input under voltage lockout
•
•
•
•
Operating temperature: -40 ºC to +85 ºC
No load consumption ≤ 0.12W
Continuous Short Circuit Protection
Over Current, Over Voltage Protection
Models
Single output
Model
Input Voltage
(V)
Output
Voltage
(V)
Output
Current max
(mA)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
9-18
9-18
18-36
18-36
18-36
18-36
18-36
5
12
3.3
5
12
15
24
1200
500
1500
1200
500
400
250
1500
1500
1500
1500
1500
1500
1500
1000
470
1800
1000
470
220
100
81
85
77
82
85
86
87
Input Voltage
(V)
Output
Voltage
(V)
Output
Current max
(mA)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
AM6C-1205S-NZ
AM6C-1212S-NZ
AM6C-2403S-NZ
AM6C-2405S-NZ
AM6C-2412S-NZ
AM6C-2415S-NZ
AM6C-2424S-NZ
Models
Dual output
Model
AM6C-1205D-NZ‡
9-18
±5
±600
1500
470
81
AM6C-1212D-NZ‡
9-18
±12
±250
1500
100
85
AM6C-2405D-NZ‡
18-36
±5
±600
1500
470
83
AM6C-2412D-NZ‡
18-36
±12
±250
1500
100
87
AM6C-2415D-NZ‡
18-36
±15
±200
1500
100
87
Only the model AM6C-2405S-NZ can add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail
screw terminal bottom plate and reverse voltage protection. The optional package will be EOL by 30 Dec, 2020.
*‡ - Reference the Safety table
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity1000
1000
Tel: +1 514 620 2722
1 of 5
Rated
Units
1500
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM6C-NZ
6 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Voltage accuracy
Voltage balance (Dual Output Models)
Cross Regulation (Dual Output Models)
Over voltage protection
Short Circuit protection
Over current protection
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Transient recovery time
Transient recovery deviation
Balanced Load
50% load on one output – 10% to
100% load on second load
LL-HL, full load
5% -100% load
Full load
20MHz Bandwidth
25% load step change
25% load step change
Typical
Maximum
Units
±2
±1.5
±3
%
%
±5
%
110-160
Continuous, Auto recovery
110-190
±1
±1.5
±0.03
75
500
±5
% of Vout
±8
% of Iout
% of Vin
%
%/oC
mV p-p
µs
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Conditions
Typical
100% load
With derating above 71ºC
300
Maximum
Units
105
KHz
o
C
o
C
o
C
95
% RH
-40 to +85
-55 to +125
Free convection
Aluminum alloy
Pin mountable
14
-ST option
36
g
-STD option
56
Aluminum case
1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm
Optional packages
See dimensions drawing
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC)
o
10sec, 1.5mm from case
300
C
Environmental Specifications
Parameters
Test mode
Acceleration
Vibration
10-55Hz
10G, 30min one cycle, every axis tested
Safety Specifications
Parameters
Approval
Standards
UL (models marked with ‡)
Information Technology Equipment
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Voltage dips, Short interruptions and
Voltage Variations Immunity
www.aimtec.com
F 051e R13.D
REV: 05/20/A
UL60950-1
EN55022 Class B, with the recommended circuit below, EN55024
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B, with the recommended circuit below
IEC 61000-4-5, ±2KV, Criteria B, with the recommended circuit below
IEC 61000-4-6, 3 Vrms, Criteria A
IEC61000-4-29, 0-70%, Criteria B
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM6C-NZ
6 Watt | DC-DC Converter
Dimensions
Pin Out Specifications
Bottom View
2.54
(0.10)
Top View
25.40
(1.00)
10.16 2.54
(0.40) (0.10)
10.16
(0.40)
4
20.32
(0.80)
25.40
(1.00)
3
+V
-V
Input Input
2.54
(0.10)
1
Side View
5
+V Output
-V Output
Common
10.16
(0.40)
2
Pin
1
2
3
4
5
Single
+V Input
-V Input
+V Output
No pin
-V Output
Dual
+V Input
-V Input
+V Output
Common
-V Output
5.08
(0.20)
11.70
(0.46)
Printed Face
1.00
(0.39)
4.10
(0.16)
2.54
(0.10)
Notes: All dimensions are typical in millimeters (inches).
Case Tolerance ±0.25 (±0.01)
Pin diameter tolerance ±0.1 (±0.004)
Pin height tolerance ±0.5 (±0.02)
Dimensions with -ST options
Pin Out Specifications
76.00
(2.99)
Pin
61.60
(2.43)
LED light
31.50
(1.24)
2
Top view
3
5
23.00
(0.91)
4
1
6
1
2
3
4
5
6
Single
No Connection
-V Input
+V Input
-V Output
No Connection
+V Output
Dual
No Connection
-V Input
+V Input
-V Output
Common
+V Output
Ø3.30
Ø0.13
8.80
(0.35)
21.20
(0.84)
Side view
Dimensions with -STD options
Dimensions: mm (inch)
Case Tolerance:± 0.50 (0.02)
Wire gauge: 24-12AWG
Torque Tightening: Max 0.4N*m
Pin Out Specifications
76.00
(2.99)
Pin
61.60
(2.43)
LED light
31.50
(1.24)
2
Top view
3
5
23.00
(0.91)
4
1
6
8.80
(0.35)
21.20
(0.84)
Side view
www.aimtec.com
F 051e R13.D
REV: 05/20/A
1
2
3
4
5
6
Single
No Connection
-V Input
+V Input
-V Output
No Connection
+V Output
Dual
No Connection
-V Input
+V Input
-V Output
Common
+V Output
Dimensions: mm (inch)
Case Tolerance:± 0.50 (0.02)
Wire gauge: 24-12AWG
Mounting Rail: TS35
Torque Tightening: Max 0.4N*m
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM6C-NZ
6 Watt | DC-DC Converter
Derating
Free Air Convection
71º C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
EMC recommended circuit
1nF/2KV
LDM
4.7µH
F1
+Vin
MOV
CY1
C1
+Vo
C3
C2
DC-DC Converter
-Vin
-Vo
CY2
1nF/2KV
MOV
C1
C2
C3
12V input
24V input
S14K20
S20K30
1000µF/35V
1000µF/50V
1µF/50V
10µF/50V
48V input
S14K60
330µF/100V
1µF/100V
10µF/100V