Series AM6T-NZ
6 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Wide 2:1 input range
Over Voltage Protection
High efficiency up to 87%
Low Ripple and Noise
• Operating temperature -40oC to + 85oC
• Input / Output isolation 1500 VDC
• Continuous short circuit protection
Models
Single output
Model
AM6T-0505S-NZ
AM6T-0512S-NZ
AM6T-0515S-NZ
AM6T-0524S-NZ
AM6T-1203S-NZ
AM6T-1205S-NZ
AM6T-1212S-NZ
AM6T-1215S-NZ
AM6T-1224S-NZ
AM6T-2403S-NZ
AM6T-2405S-NZ
AM6T-2412S-NZ
AM6T-2415S-NZ
AM6T-2424S-NZ
AM6T-4803S-NZ
AM6T-4805S-NZ
AM6T-4812S-NZ
AM6T-4815S-NZ
AM6T-4824S-NZ
Input
Voltage (V)
Output Voltage
(V)
Output Current
max(mA)
Isolation
(VDC)
Efficiency
(%)
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
1200
500
400
250
1500
1200
500
400
250
1500
1200
500
400
250
1500
1200
500
400
250
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
78
84
84
84
75
80
84
85
85
78
82
85
86
86
79
83
87
88
87
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
±5
±12
±15
±24
±5
±12
±15
±24
±5
±12
±15
±24
±5
±12
±15
±24
±600
±250
±200
±125
±600
±250
±200
±125
±600
±250
±200
±125
±600
±250
±200
±125
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
78
84
84
84
80
84
85
84
83
86
87
85
83
87
85
85
Models
Dual output
Model
AM6T-0505D-NZ
AM6T-0512D-NZ
AM6T-0515D-NZ
AM6T-0524D-NZ
AM6T-1205D-NZ
AM6T-1212D-NZ
AM6T-1215D-NZ
AM6T-1224D-NZ
AM6T-2405D-NZ
AM6T-2412D-NZ
AM6T-2415D-NZ
AM6T-2424D-NZ
AM6T-4805D-NZ
AM6T-4812D-NZ
AM6T-4815D-NZ
AM6T-4824D-NZ
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity 1000
1000
Conditions
Typical
Maximum
Units
VDC
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
5 Vin Vo1, 5% to 100% Load
5 Vin Vo2, 5% to 100% Load
Other models, 5% to 100% Load
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Cross Regulation (dual)
Temperature coefficient
Transient Recovery Time
Transient Response Deviation
Ripple& Noise
Over Voltage Protection
Over current protection
Maximum
Units
±2
±3
±3
%
±1
±1
±1
Continuous
Auto-recovery
±0.2
±0.5
Vo1, Full Load, LL-HL
Vo2, Full Load, LL-HL
5 Vin Vo1, 5% to 100% Load
5 Vin Vo2, 5% to 100% Load
Other models Vo1, 5% to 100% Load
Other models Vo1, 5% to 100% Load
Vo1 50% load, Vo2 10-100% load
±0.5
±1
±1
±1.5
±1
±1.5
±5
±0.5
±0.5
±0.03
300
±5
±3
25% load step
3.3V, 5V, ±5Vout, 25% load step
Others, 25% load step
5% to 100% Load
%
%
%
%/oC
µsec
140
500
±8
±5
100
110 to 160
190
mVp-p
%Vout
%Iout
Conditions
Typical
Maximum
Units
100% load
Derating above +71
300
%
General Specifications
Parameters
Switching frequency*
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
-40 to +85
-55 to +125
100
KHz
oC
oC
o
C
Free air convection
95
Black Anodized Aluminum
%
12
g
1.26 x 0.79 x 0.42inches (32.00 x 20.00 x 10.80mm)
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
*Bellow 50% load the switching frequency decreases with the decrease of the load.
Environment Specifications
Test
Parameters
Conditions
Vibration
Test mode
Acceleration
10-150Hz
5g, 30min, every axis tested
www.aimtec.com
F 051e R6.A
REV/12/19/A
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM6T-NZ
6 Watt | DC-DC Converter
Safety Specifications
Parameters
Designed to meet IEC/UL 60950-1
CISPR32 / EN55032, Class A (without external components)(Except 5Vin model),
Class B (with recommended EMC circuit part B)(5Vin model with recommended
circuit)
IEC61000-4-2, Contact ±4KV, Criteria B
Standards Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
IEC61000-4-3, 10V/m, Criteria A
Electrical Fast Transient/Burst Immunity IEC61000-4-4, ±2KV, Criteria B, (with recommended EMC circuit part A)
Surge Immunity
IEC61000-4-5, L-L ±2KV, Criteria B, (with recommended EMC circuit part A)
RF, Conducted Disturbance Immunity
IEC61000-4-6, 3Vrms, Criteria A
EMC - Radiated & Conducted emission
Pin Out Specifications
Dimensions
32.00
(1.26)
1500VDC
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
3
9
11
15.24
(0.60)
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
20.00
(0.79)
Dual
Bottom View
23 22
16
2.54
(0.10)
Printed Face
14
5.08
(0.20)
Built-in Stand-offs to
ease PCB cleaning
4.10
(0.16)
0.50
(0.02)
2
3
9
11
14
16
22
23
2
Single
10.30
(0.40)
Pin
0.50
(0.02)
Recommended Circuit
For Ripple & Noise reduction
Single Output
+V output
+ V input
+ V input
Cin
Dual Output
+V output
+
+
DC
DC
Cin
Cout
- V input
-V output
+
Cout
+
- V input
DC
DC
Common
+
Cout
-V output
External Capacitor Tables
Vin (VDC)
Cin (uF)
Cout (uF)
5/12/24
48
100
10 ~ 47
10
10
www.aimtec.com
F 051e R6.A
REV/12/19/A
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM6T-NZ
6 Watt | DC-DC Converter
Recommended EMC Circuit
+ Vin
+Vout
LDM
4.7µH
FUSE
C3
MOV
CY2
C1
+
Cout
C2 +
DC
DC
- Vin
Model
CY1
B
A
MOV
12 Vin
S14K20
24 Vin
S20K30
48 Vin
S14K60
Note: Fuse is user selectable
Part A for EMS, part B for EMI.
- Vout
C1
C2
C3
CY1/CY2
1µF / 50V
1µF / 50V
1µF / 100V
100µF / 35V
100µF / 50V
100µF / 100V
1000µF / 35V
1000µF / 50V
680µF / 100V
1nF/2KV
Recommended EMC Circuit for 5V input model
+ Vin
+Vout
CY2
2.2nF/2KV
FUSE
+
10µF
+
2200μF/
35V
4.7μF/
50V
- Vin
100μF/
35V
LCM
2.2mH
CY1
Or
2.2nF/2KV
AMFC22-3NZ
B
A
4.7μF/
50V
DC
DC
- Vout
Part A for EMS, part B for EMI.
Derating
Free Air Convection
Other models
100
Output Power (%)
5Vin model
80
65
60
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
71 75
80
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity
很抱歉,暂时无法提供与“AM6T-0524S-NZ”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+125.99444
- 5+125.02151
- 10+122.75529
- 20+118.62627