AMED120-JZ
AC-DC Converter
Click to
ORDER
AMED120-JZ
samples
The new AMED120-JZ is a brand-new AC/DC converter that offers much greater cost
effectiveness due to material normalization and production automation also leading
to improved reliability and performance. Offering a commercial input voltage range
of 85-264VAC and an output voltage range from 12-48V, this series will offer many
benefits to your new system design.
This new series offers great operating temperatures, from -20°C to 60°C also features
an isolation of 4000VAC for improved reliability and system safety. Furthermore, a
higher MTBF of 300,000h, output short circuit protection (OSCP), output over-current
protection (OCP), over temperature protection (OTP) and an output over-voltage
protection (OVP) come standard with the series.
The AMED120-JZ is perfect for electric distribution box, grid power, instrumentation,
industrial controls, building automation applications.
DIN Rail
Features
•
•
•
•
•
Summary
Universal Input: 90 - 264VAC/127 - 370VDC
Operating Temp: -20 °C to +60 °C
High isolation voltage: 4000VAC
Low ripple & noise, 150mV(p-p), max.
Output short circuit, over-current, over-voltage,
over-temperature protection
528
AMED120-JZ
48
120
4000
85
70
60
264
40
12
1000
90
0
3.3
1
-10
-20
-25
-40
Input voltage Output voltage
(VAC)
(V)
Isolation
(VAC)
Power
(W)
Temp. range
(°C)
Derating
(°C)
Applications
Training
Press Release
Coming Soon!
Power Grid
Product Training Video
(click to open)
F 052e R4
Industrial
Telecom
Instrumentation
Application Notes
www.Aimtec.com
1
AMED120-JZ
AC-DC Converter
Models & Specifications
Single Output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage
(W)
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
load (µF)
Efficiency
@ 230VAC
Typ. (%)
AMED120-12SJZ
AMED120-24SJZ
AMED120-48SJZ
90~264/47~63
90~264/47~63
90~264/47~63
127~370
127~370
127~370
120
120
120
12
24
48
10
5
2.5
3000
1200
800
85
88
89
Input Specifications
Parameters
Input Current
Inrush Current
Leakage Current
Conditions
Typical
115VAC
230VAC
115VAC, cold start
230VAC, cold start
240VAC
30
55
100
www.Aimtec.com
Maximum
Units
VAC
VAC
VAC
MΩ
2
AMED120-JZ
AC-DC Converter
General Specifications
Parameters
Over Current protection
Over voltage protection
Over temperature protection
Short circuit protection
Switching Frequency
Operating temperature
Storage temperature
Power derating
Temperature coefficient
Protection Class
Cooling
Storage Humidity
Operating Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
Maximum
Constant current, self- recovery, room/high temp.
105 - 150
Constant current, self- recovery, low temp.
>105
12 VDC Output, manual-recovery
≤ 16
24 VDC Output, manual-recovery
≤ 33
48 VDC Output, manual-recovery
≤ 60
Output voltage turn off, manual-recovery
Hiccup, Continuous, Self-recovery (Recovery time < 3S)
65
-20 to +60
-40 to +85
All models, 115VAC, -20 °C to -10°C
2.0
All models, 230VAC, 40 °C to 60°C
2.5
12 VDC Output, 230VAC, 45 °C to 60°C
3.33
24,48 VDC Output, 230VAC, 50 °C to 60 °C
5
90 to 115 VAC
1
± 0.03
Class I
Free air convection
Non-condensing
>10
95
Non-condensing
>20
90
Metal (AL1100, SGCC)
410
1.42 x 4.92 x 3.94 inches (36.00 x 125.00 x 100.00 mm)
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)
Units
% of Iout
% of Iout
VDC
VDC
VDC
KHz
°C
°C
% / °C
% / °C
% / °C
% / °C
% / VAC
% / °C
% RH
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity
很抱歉,暂时无法提供与“AMED120-48SJZ”相匹配的价格&库存,您可以联系我们找货