0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AMEOF225-12SHAMJZ

AMEOF225-12SHAMJZ

  • 厂商:

    AIMTEC

  • 封装:

  • 描述:

    3W DC/DC Converter

  • 数据手册
  • 价格&库存
AMEOF225-12SHAMJZ 数据手册
AMEOF225-HAMJZ AC-DC Converter Click to ORDER AMEOF225-HAMJZ Open Frame/ Enclosed samples The AMEOF225-HAMJZ series is one of Aimtec’s compact (2”x4”x1”) 225W AC/DC converter with active PFC and is suitable for medical equipment. It features a universal AC input, which also accepts a DC input voltage, is costeffective, has a high efficiency and high reliability and comes with double or reinforced isolation. These converters offer excellent EMC and safety performance, which with UL62368-1, ES60601-1 approvals and meets IEC/EN62368-1, GB4943, EN60335-1, IEC/EN61558-1, IEC/EN60601-1 standards and can be widely used in industrial, LED, street light control, security, telecommunications, smart home and medical applications. Features • • • • • • • • Summary Universal Input: 85 - 264VAC/120 - 370VDC Active power factor correction Low leakage current: 0.1mA max. High isolation voltage: 4000VAC Output short circuit, over-current, over-voltage, over temperature protection Low no-load power consumption of 0.3W Suitable for Type BF application Approvals UL62368-1, ES60601-1; Designed to meet IEC/EN62368-1, EN60335-1, IEC/EN615581 IEC/EN60601-1 With PFC AMEOF225-HAMJZ 528 4000 225 125 48 125 140 264 70 45 12 1000 85 1 3.3 -30 Input voltage Output voltage (VAC) (V) Isolation (VAC) Power (W) -40 -40 Temp. range (°C) Derating (°C) Applications Training Press Release Coming Soon! Power Grid Product Training Video (click to open) F 052e R4 Rev: 08/21/B Industrial Telecom Medical Application Notes www.Aimtec.com 1 AMEOF225-HAMJZ AC-DC Converter Models & Specifications Single Output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Cooling method Max Output wattage Output Voltage (V) Output Voltage Adjustable Range (V) (W) Free air 140 85-264/ AMEOF225-12SHAMJZ 120-370 12 11.8-12.6 47-63 13CFM 225 Free air 140 85-264/ AMEOF225-15SHAMJZ 120-370 15 14.7-15.8 47-63 13CFM 225 Free air 140 85-264/ AMEOF225-24SHAMJZ 120-370 24 23.5-25.2 47-63 13CFM 225 Free air 130 85-264/ AMEOF225-27SHAMJZ 120-370 27 26.5-28.4 47-63 13CFM 225 Free air 140 85-264/ AMEOF225-36SHAMJZ 120-370 36 35.28-37.8 47-63 13CFM 225 Free air 140 85-264/ AMEOF225-48SHAMJZ 120-370 48 47.1-50.4 47-63 13CFM 225 Free air 140 85-264/ AMEOF225-54SHAMJZ #∅ 120-370 54 52.5-55.5 47-63 13CFM 225 Add suffix -F for enclosed package. (ex. AMEOF225-12SHAMJZ-F is enclosed package version) Max Output Current (A) Maximum capacitive load (µF) Efficiency @230VAC Typ. (%) 6000 93 5000 93 3200 94 2400 94 2000 94 1600 94 1000 94 11.67 18.75 9.33 15 5.83 9.4 4.81 8.35 3.88 6.25 2.91 4.7 2.59 4.17 Input Specifications Parameters Input current Inrush current Leakage Power factor Conditions Typical 115VAC 230VAC 115VAC, cold start 230VAC, cold start 240VAC, normal condition 240VAC, single fault condition 115VAC, 100% load 230VAC, 100% load ≥0.99 ≥0.95 Conditions Typical Maximum Units 3 2 0.1 0.5 A A A A mA mA Maximum Units 40 75 Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise* Hold up time F 052e R4 Rev: 08/21/B Full load 0-100% load 12V, 15-100% load 15, 24, 27, 36, 48V, 15-100% load 54V, 15-100% load 12V, 0-15% load 15, 24, 27, 36, 48V, 0-15% load 54V, 0-15% load 230VAC, Free air convection 230VAC, 13CFM www.Aimtec.com ±1 ±0.5 ±0.5 60 100 200 120 200 400 ≥16 ≥12 % % % mV p-p mV p-p mV p-p mV p-p mV p-p mV p-p ms ms 2 AMEOF225-HAMJZ AC-DC Converter * Ripple and Noise are measured at 20MHz bandwidth. Open frame models are measured with a 10μF electrolytic capacitor and a 0.1μF ceramic capacitor. Enclosed models are measured with a 47μF electrolytic capacitor and a 0.1μF ceramic capacitor. Please refer to the application note for specific details. Isolation Specification Parameters Conditions Tested I/O voltage 60 sec, leakage ≤ 10mA Tested I, O/PE voltage 60 sec, leakage ≤ 10mA Resistance I/O* 500VDC Resistance I, O/PE* 500VDC MOP I/O MOP I, O/PE * Tested under 25±5°C ambient temperature with relative humidity 50 >50 Units VAC VAC MΩ MΩ 2xMOPP 1xMOPP General Specifications Parameters Conditions Typical Maximum Units Protection class Over current protection Class II without protective earth connection, Class I with protective earth connection Auto recovery, hiccup ≥ 110 % of Iout 12Vout, shut down, manual recovery 16 VDC 15Vout, shut down, manual recovery 20 VDC 24Vout, shut down, manual recovery 32 VDC Over voltage protection 27Vout, shut down, manual recovery 35 VDC 36Vout, shut down, manual recovery 50 VDC 48, 54Vout, shut down, manual recovery 60 VDC Short circuit protection Hiccup, Continuous, Auto recovery time < 3S Over temperature protection Shut down, manual recovery after the temperature drops below the threshold 15V 24V/0.25A, Voltage accuracy ±15% Fan power 12, 24, 27, 36, 48, 54V 12V/0.5A, Voltage accuracy ±15% No-load power consumption 0.5 W Operating temperature See derating graph -40 to +70 °C Storage temperature -40 to +85 °C -40 °C to -30 °C, forced air convection 13CFM 2.0 %/°C +50 °C to +70 °C, forced air convection 13CFM 2.5 %/°C Power Derating +45 °C to +70 °C, free air convection, open frame 2.0 %/°C +40 °C to +70 °C, free air convection, enclosed 2.0 %/°C 85VAC to 115VAC 1.0 %/VAC Temperature coefficient ±0.03 %/°C Cooling Free air convection, forced air convection 13CFM Non-condensing, storage >10 95 % RH Humidity Non-condensing, operating >20 90 % RH Case material Enclosed package Metal (1100 Aluminum, SUS304) Open frame 175 g Weight Enclosed 260 g Open frame 4.00 x 2.00 x 1.00 inches (101.6 x 50.8 x 25.4 mm) Dimensions (L x W x H) Enclosed 4.07 x 2.44 x 1.46 inches (103.4 x 62.0 x 37.0 mm) MTBF > 300 000 hrs (MIL-HDBK -217F, t=+25°C) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity
AMEOF225-12SHAMJZ 价格&库存

很抱歉,暂时无法提供与“AMEOF225-12SHAMJZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货