AMES200-NZ
AC-DC Converter
Preliminary
Click to
ORDER
AMES200-NZ
samples
The AMES200-NZ is an AC/DC converter that offers much greater cost effectiveness
due to material normalization and production automation also leading to improved
reliability and performance. Offering a commercial input voltage range of 90-264VAC
and an output voltage range from 5-48V, this series will offer many benefits to your
new system design.
This new series offers great operating temperatures, from -30°C to 70°C and also
features an isolation of 3000VAC for improved reliability and system safety.
Furthermore, a high MTBF of 300,000h, output short circuit protection (OSCP), output
over-current protection (OCP), output over-voltage protection (OVP) and overtemperature protection (OTP) come standard with the series.
The AMES200-NZ is great for street lighting controls, grid power, instrumentation,
industrial controls, communication, and civil applications.
Enclosed
Features
•
•
•
•
•
•
•
•
•
Summary
Universal Input: 90 - 264VAC/240 - 373VDC
Operating Temp: -30 °C to +70 °C
High isolation voltage: Up to 3000VAC
Low ripple & noise, 200mV(p-p) typ.
Output short circuit, over-current, over-voltage
and over temperature protection
Regulated Output
Optional conformal coating
Surge immunity: 300VAC for 5s
AMES200-NZ
528
48
4000
250
212.4
3000
300
264
125
125
150
70
90
0
40
1000
5
3.3
1
-30
Input voltage Output voltage
(VAC)
(V)
Isolation
(VAC)
Power
(W)
-40
-30
-40
Temp. range
(℃)
Derating
(℃)
Applications
Training
Press Release
Coming Soon!
Power Grid
Product Training Video
(click to open)
F 052e R4
Rev: 12/21/A
Industrial
Telecom
Instrumentation
Application Notes
www.Aimtec.com
1
AMES200-NZ
AC-DC Converter
Preliminary
Models & Specifications
Single Output
Model
Input Voltage
(VAC/VAC/Hz)*
Input
Output Output Voltage
Max Output
Voltage
Voltage
Adjustable
Wattage (W)
(VDC)**
(V)
Range (V)
Output
Current
(A)
Maximum
capacitive
load (µF)
Efficiency
@230VAC
(%)
AMES200-5SNZ
90-132/ 180-264/ 47-63
240-373 150/200***
5
4.5 - 5.5
30
10000
87
AMES200-12SNZ
90-132/ 180-264/ 47-63
240-373
204
12
10.2 - 13.8
17
4000
87.5
AMES200-15SNZ
90-132/ 180-264/ 47-63
240-373
210
15
13.5 - 18
14
3300
88
AMES200-24SNZ
90-132/ 180-264/ 47-63
240-373
211.2
24
21.6 - 28.8
8.8
1500
88.5
AMES200-36SNZ
90-132/ 180-264/ 47-63
240-373
212.4
36
32.4 - 39.6
5.9
1500
89
AMES200-48SNZ
90-132/ 180-264 /47-63
240-373
211.2
48
43.2 - 52.8
4.4
470
89.5
* Switch the voltage level switch to 115 for 90-132VAC input voltage and 230 for 180-264VAC input voltage.
** Switch the voltage level switch to 230 for 240-373VDC input voltage.
*** AMES200-5SNZ can output 200W for 60 sec and 150W continuously.
Add suffix “-P” for optional terminal protective cover (ex. AMES200-5SNZ-P is terminal with protective cover version) or suffix “-Q” for optional
conformal coating (ex. AMES200-5SNZ-Q is conformal coating version).
Input Specifications
Parameters
Input current
Inrush current
Conditions
Typical
Maximum
Units
115VAC
230VAC
115VAC, 230VAC, Cold start
60
5
3
80
A
A
A
Conditions
Typical
Maximum
Units
Output Specifications
Parameters
Full load, 5V output
±3
%
Full load, 12V output
±1.5
%
Full load, 12V,24V,36V,48V output
±1
%
Line regulation
Full load
±0.5
%
0-100% load, 5V output
±2
%
Load regulation
0-100% load, 12V output
±1
%
0-100% load, 12V,24V,36V,48V output
±0.5
%
5V,12V,15V,24V, output
150
mV p-p
Ripple & Noise*
36V,48V output
200
mV p-p
115VAC
≥ 12
ms
Hold up time
230VAC
≥ 16
ms
* Ripple and Noise are measured at 20MHz bandwidth with a 47μF electrolytic capacitor and a 0.1μF ceramic capacitor. Please refer to the
application note for specific details.
Voltage accuracy
Isolation Specifications
Parameters
Tested I/O voltage
Tested Input to GND voltage
Tested Output to GND voltage
Resistance (I/O, I/O to GND)
F 052e R4
Rev: 12/21/A
Conditions
60 sec, leakage current < 5mA
60 sec, leakage current < 5mA
60 sec, leakage current < 5mA
500VDC
www.Aimtec.com
Typical
Rated
Units
3000
2000
500
100
VAC
VAC
VAC
MΩ
2
AMES200-NZ
AC-DC Converter
Preliminary
General Specifications
Parameters
Conditions
Safety class
Switching Frequency
Over Current protection
Typical
Maximum
Units
Class I
65
KHz
Auto recovery
≥ 110
185
% of Iout
Output voltage turn off, Manual recovery, 5V output
8
VDC
Output voltage turn off, Manual recovery, 12V output
18
VDC
Output voltage turn off, Manual recovery, 15V output
22
VDC
Over voltage protection
Output voltage turn off, Manual recovery, 24V output
33.6
VDC
Output voltage turn off, Manual recovery, 36V output
46.8
VDC
Output voltage turn off, Manual recovery, 48V output
60
VDC
Over temperature protection
Output voltage turn off, Manual recovery
Short circuit protection
Hiccup, Continuous, Auto recovery, Recover time < 5 sec
Operating temperature
See derating graph
-30 to +70
°C
Storage temperature
-40 to +85
°C
No-load power consumption
0.75
W
40 °C to 70 °C, 5V output
1.66
% / °C
50 °C to 70 °C, Others
2.5
% / °C
Power derating
90VAC ~ 100VAC, 60Hz
2
% / VAC
90VAC ~ 100VAC, 50Hz
3.5
% / VAC
Ambient temperature derating
Operating altitude > 2000m
5
°C / 1000m
Temperature coefficient
±0.03
% / °C
Cooling
Free air convection
Non-condensing, Storage
≥ 10
95
% RH
Humidity
Non-condensing, Operating
≥ 20
90
% RH
Case material
Metal (1100 Aluminum, SGCC)
Weight
520
g
Dimensions (L x W x H)
7.05 x 3.90 x 1.18inch (179.0 x 99.0 x 30.0mm)
MTBF
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity