AMES35-NZ
AC-DC Converter
Click to
ORDER
AMES35-NZ
samples
The AMES35-NZ is an AC/DC converter that offers much greater cost effectiveness due
to material normalization and production automation also leading to improved
reliability and performance. Offering a commercial input voltage range of 85-264VAC
and an output voltage range from 5-24V, this series will offer many benefits to your
new system design.
This new series offers great operating temperatures, from -30°C to 70°C and also
features an isolation of 4000VAC for improved reliability and system safety.
Furthermore, a high MTBF of 300,000h, output short circuit protection (OSCP), output
over-current protection (OCP) and an output over-voltage protection (OVP) come
standard with the series.
The AMES35-NZ is perfect for street lighting controls, grid power, instrumentation,
industrial controls, communication, and civil applications.
Enclosed
Summary
Features
•
•
•
•
•
•
•
Universal Input: 85 - 264VAC/120 - 373VDC
Operating Temp: -30 °C to +70 °C
High isolation voltage: Up to 4000VAC
Low ripple & noise, 180mV(p-p) typ.
Output short circuit, over-current, over-voltage
protection
Regulated Output
Surge immunity: 300VAC for 5s
AMES35-NZ
528
264
4000
48
100
24
70
36.5
85
0
1000
5
3.3
125
125
3000
300
50
32
1
Input voltage Output voltage
(VAC)
(V)
Isolation
(VAC)
Power
(W)
-30
-30
Temp. range
(℃)
Derating
(℃)
Applications
Training
Press Release
Coming Soon!
Power Grid
Product Training Video
(click to open)
F 052e R4
REV: 02/21/A
Industrial
Telecom
Instrumentation
Application Notes
www.Aimtec.com
1
AMES35-NZ
AC-DC Converter
Models & Specifications
Single Output
Model
AMES35-5SNZ#
AMES35-12SNZ#
AMES35-15SNZ#
AMES35-24SNZ#
Input
Voltage
(VAC/Hz)
Max
Input
Output
Voltage
Wattage
(VDC)
(W)
Output
Voltage
(V)
Output Voltage
Adjustable Range (V)
Output
Current
max (A)
Maximum
capacitive load
(µF)
Efficiency
@230VAC
Typ. (%)
7
8000
83
85-264/47-63
120-373
35
5
4.5-5.5
85-264/47-63
120-373
36
12
10.2-13.8
3
1500
87
85-264/47-63
120-373
36
15
13.5-18
2.4
1000
89
85-264/47-63 120-373
36
24
21.6-28.8
1.5
750
88
Note: Add suffix “-P” for optional terminal protective cover (ex. AMES35-5SNZ-P is terminal with protective cover version) or suffix “-Q” for
conformal coating (ex. AMES35-5SNZ-Q is conformal coating version).
Dual Output
Model
Input
Voltage
(VAC/Hz)
Max
Output
Input
Output
Voltage
Voltage
Wattage (Vo1/Vo2)
(VDC)
(W)
(V)
AMES35-0512DNZ# 85-264/47-63 120-373
AMES35-0524DNZ# 85-264/47-63 120-373
32
5/12
Working Current
Range
(Io1/Io2)
(A)*
Output
Current
(Io1/Io2)
(A)
Maximum
capacitive load
(Vo1/Vo2)
(µF)
Efficiency
@230VAC
(%)
0.4-5/0.1-1.5
4/1
4000/1000
81
35
5/24
0.22-4/0.1-1.3
2.2/1
2200/1000
83
Note: Use suffix “-Q” for conformal coating (ex. AMES35-0512DNZ -Q is conformal coating version).
*Maximum duration 3sec when any of the outputs reaches its maximum working current. Total output power cannot exceed the rated power.
Tri Output
Model
Input
Voltage
(VAC/Hz)
Max
Output
Input
Output
Voltage
Voltage
Wattage (Vo1/Vo2/
(VDC)
(W)
Vo3) (V)
AMES35-051212TNZ 85-264/47-63 120-373
AMES35-051515TNZ 85-264/47-63 120-373
AMES35-052412TNZ 85-264/47-63 120-373
Working Current
Range
(Io1/Io2/Io3)
(A)
33
+5/+12/-12
35
+5/+15/-15 0.25-3.5/0.1-1.5/0.05-0.5
0.3-4/0.1-1.5/0.05-0.5
Output
Current
(Io1/Io2/
Io3) (A)
Maximum
capacitive load
(Vo1/Vo2/Vo3)
(µF)
Efficiency
@230VAC
(%)
3/1/0.5
3000/1000/470
81
2.5/1/0.5
2500/1000/470
81
36.5
+5/+24/+12 0.25-3.5/0.05-1/0.1-1
2.5/0.5/1
2500/470/1000
81
Note: Use suffix “-Q” for conformal coating (ex. AMES35-051212TNZ -Q is conformal coating version).
*Maximum duration 3sec when any of the outputs reaches its maximum working current. Total output power cannot exceed the rated power.
Parameters
Input current
Inrush current
Leakage current
F 052e R4
REV: 02/21/A
Conditions
Single output, 115VAC
Single output, 230VAC
Others, 115VAC
Others, 230VAC
Single output, cold start, 115VAC
Single output, cold start, 230VAC
Others, 115VAC
Others, 230VAC
Single output, 240VAC
others, 240VAC
www.Aimtec.com
Typical
Maximum
Units
0.8
0.6
0.75
0.5
A
A
A
A
A
A
A
A
mA
mA
30
50
30
50
0.75
2.0
2
AMES35-NZ
AC-DC Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Single output, Full load, 5V output
±2
%
Single output, Full load, Others
±1
%
Dual output, Full load, Output 1
±2
%
Dual output, Full load, AMES35-0512DNZ, Output 2
±8
%
Dual output, Full load, AMES35-0524DNZ, Output 2
≥ -4
+8
%
Voltage accuracy
Tri output, Full load, Output 1
±2
%
Tri output, Full load, AMES35-051212TNZ, Output 2
±6
%
Tri output, Full load, Others, Output 2
±8
%
Tri output, Full load, AMES35-051212TNZ, Output 3
±6
%
Tri output, Full load, Others, Output 3
±8
%
Single output, Full load
±0.5
%
Dual output, Full load, Output 1
±0.5
%
Dual output, Full load, Output 2
±1.5
%
Line regulation
Tri output, Full load, Output 1
±0.5
%
Tri output, Full load, Output 2
±1
%
Tri output, Full load, Output 3
±1
%
Single output, 0-100% load, 5V output
±1
%
Single output, 0-100% load, Others
±0.5
%
Dual output, 10-100% load, Output 1
±0.5
%
Dual output, 10-100% load, Output 2
±5
%
Load regulation**
Tri output, 10-100% load, Output 1
±1.5
%
Tri output, 10-100% load, Output 2
±3
%
Tri output, 10-100% load, Output 3
±3
%
Single output, 5V output
80
mV p-p
Single output, 12V,15V output
120
mV p-p
Single output, 24V output
150
mV p-p
Dual output, Output 1
80
mV p-p
Dual output, Output 2
150
mV p-p
Ripple & Noise*
Tri output, Output 1
80
mV p-p
Tri output, AMES35-051212TNZ, Output 2
120
mV p-p
Tri output, others, Output 2
150
mV p-p
Tri output, AMES35-051515TNZ, Output 3
150
mV p-p
Tri output, others, Output 3
120
mV p-p
Single output, 115VAC
≥8
ms
Single output, 230VAC
≥ 30
ms
Hold up time
Others, 115VAC
5
ms
Others, 230VAC
30
ms
Output 1 of dual, tri output models
4.75 – 5.5
V
Voltage adjustable range
Dual, tri output
2
S
Start-up delay time
Dual, Tri output, 10-90%, 115VAC/60Hz, 230VAC/50Hz
30
mS
Rise time
* Ripple and Noise are measured at 20MHz bandwidth with a 47μF electrolytic capacitor and a 0.1μF ceramic capacitor. Please refer to the
application note for specific details.
** Equal-scale load for dual and tri output models.
F 052e R4
REV: 02/21/A
www.Aimtec.com
3
AMES35-NZ
AC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Tested Input to GND voltage
Tested Output to GND voltage
Tested Vo1 to Vo2 voltage
Resistance (I/O, I/O to GND)
Conditions
Typical
60 sec, leakage current < 10mA, Single output
60 sec, leakage current < 10mA, Dual, tri output
60 sec, leakage current < 10mA, Single, Dual, tri output
60 sec, leakage current < 10mA, Single output
60 sec, leakage current < 10mA, Dual, tri output
Dual output model only
500VDC, Single output
500VDC, Dual, tri output
Rated
Units
4000
3000
2000
1250
500
500
50
100
VAC
VAC
VAC
VAC
VAC
VDC
MΩ
MΩ
Maximum
Units
General Specifications
Parameters
Conditions
Typical
Safety class
Switching Frequency
Class I
Single output
65
KHz
Single output, Auto recovery
≥ 110
200
% of Iout
Dual output, equal-scale load, Auto recovery
≥ 110
220
% of Iout
Over Current protection
Tri output, equal-scale load, Auto recovery
≥ 110
180
% of Iout
Single output, 5V output, Voltage clamp
6.3
VDC
Single output, 12V output, Voltage clamp
16.2
VDC
Single output, 15V output, Voltage clamp
21.75
VDC
Over voltage protection
Single output, 24V output, Voltage clamp
33.6
VDC
Dual, tri output, Voltage clamp
5.75 ≤ Output 1 ≤ 6.75
VDC
Hiccup, Continuous, Auto recovery, Recovery time < 5 sec
Short circuit protection
See derating graph
-30 to +70
°C
Operating temperature
-40 to +85
°C
Storage temperature
Single output
0.3
W
Power consumption
Single output, -30°C to -25°C, 85VAC - 100VAC
5
% / °C
Single output, 50 °C to 70 °C
2
% / °C
Single output, 85VAC - 100VAC
1.33
% / VAC
Power derating
Dual, tri output, 50 °C to 70 °C
2.5
% / °C
Dual, tri output, 85VAC - 115VAC
0.667
% / VAC
Dual, tri output, 120VDC - 160VDC
0.5
% / VDC
Ambient temperature derating
Operating altitude > 2000m
5
°C / 1000m
±0.03
% / °C
Temperature coefficient
Free air convection
Cooling
Non-condensing
≥ 10
95
% RH
Humidity
Metal (1100 Aluminum, SGCC)
Case material
Single output
170
g
Weight
Dual, tri output
210
g
Single output
3.90 x 3.23 x 1.18inch (99.0 x 82.0 x 30.0mm)
Dimensions (L x W x H)
Dual, tri output
3.90 x 3.82 x 1.18inch (99.0 x 97.0 x 30.0mm)
> 300 000 hrs (MIL-HDBK -217F, t=+25°C)
MTBF
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity