0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AMES50-36SNZ

AMES50-36SNZ

  • 厂商:

    AIMTEC

  • 封装:

  • 描述:

    AIMTEC - AMES50-36SNZ - AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 52.2 W, 36 VDC, 1.45 A

  • 数据手册
  • 价格&库存
AMES50-36SNZ 数据手册
AMES50-NZ AC-DC Converter Click to ORDER AMES50-NZ samples The AMES50-NZ is an AC/DC converter that offers much greater cost effectiveness due to material normalization and production automation also leading to improved reliability and performance. Offering a commercial input voltage range of 85-264VAC and an output voltage range from 5-24V, this series will offer many benefits to your new system design. This series offers great operating temperatures, from -30℃ to 70℃ and also features an isolation of 4000VAC for improved reliability and system safety. Furthermore, a high MTBF of 300,000h, output short circuit protection (OSCP), output over-current protection (OCP) and an output over-voltage protection (OVP) come standard with the series. The AMES50-NZ is perfect for street lighting controls, grid power, instrumentation, industrial controls, communication, and civil applications. Enclosed Summary Features • • • • • • • Universal Input: 85 - 264VAC/120 - 373VDC Operating Temp: -30 °C to +70 °C High isolation voltage: Up to 4000VAC Low ripple & noise, 180mV(p-p) typ. Output short circuit, over-current, over-voltage protection Regulated Output Surge immunity: 300VAC for 5s AMES50-NZ 528 4000 48 3000 300 264 100 125 125 54 50 70 50 85 0 1000 5 3.3 1 Input voltage Output voltage (VAC) (V) Isolation (VAC) Power (W) -30 -30 Temp. range (℃) Derating (℃) Applications Training Press Release Coming Soon! Power Grid Product Training Video (click to open) F 052e R4 Rev: 03/21/A Industrial Telecom Instrumentation Application Notes www.Aimtec.com 1 AMES50-NZ AC-DC Converter Models & Specifications Single Output Model AMES50-5SNZ AMES50-12SNZ AMES50-15SNZ AMES50-24SNZ AMES50-36SNZ AMES50-48SNZ Input Voltage (VAC/Hz) Max Input Output Voltage Wattage (VDC) (W) Output Voltage (V) Output Voltage Adjustable Range (V) Output Current max (A) Maximum capacitive load (µF) Efficiency @230VAC Typ. (%) 85-264/47-63 120-373 50 5 4.5-5.5 10 8500 83 85-264/47-63 120-373 50.4 12 10.2-13.8 4.2 2000 86 85-264/47-63 120-373 51 15 13.5-18 3.4 1500 88 85-264/47-63 120-373 52.8 24 21.6-28.8 2.2 1000 88 85-264/47-63 120-373 52.2 36 32.4-39.6 1.45 800 89 85-264/47-63 120-373 52.8 48 43.2-52.8 1.1 680 90 Note: Add suffix “-P” for optional terminal protective cover (ex. AMES50-5SNZ-P is terminal with protective cover version) or suffix “-Q” for conformal coating (ex. AMES50-5SNZ-Q is conformal coating version). Dual Output Model AMES50-0512DNZ AMES50-0524DNZ Input Voltage (VAC/Hz) 85-264/47-63 Max Output Input Output Voltage Voltage Wattage (Vo1/Vo2) (VDC) (W) (V) 120-373 54 5/12 Working Current Range (Io1/Io2) (A)* Output Current (Io1/Io2) (A) Maximum capacitive load (Vo1/Vo2) (µF) Efficiency @230VAC (%) 0.3-6/0.2-3 6/2 6000/2000 83 85-264/47-63 120-373 53.6 5/24 0.4-6/0.14-2 4/1.4 4000/1000 84 Note: Use suffix “-Q” for conformal coating (ex. AMES50-0512DNZ -Q is conformal coating version). *Maximum duration 3sec when any of the outputs reaches its maximum working current. Total output power cannot exceed the rated power. Tri Output Model Input Voltage (VAC/Hz) Max Output Input Output Voltage Voltage Wattage (Vo1/Vo2/ (VDC) (W) Vo3) (V) AMES50-051212TNZ 85-264/47-63 120-373 AMES50-051515TNZ 85-264/47-63 120-373 AMES50-052412TNZ 85-264/47-63 120-373 Working Current Range (Io1/Io2/Io3) (A)* Output Current (Io1/Io2/ Io3) (A) Maximum capacitive load (Vo1/Vo2/Vo3) (µF) Efficiency @230VAC (%) 50 +5/+12/-12 0.4-5/0.2-2.5/0.1-1 4/2/0.5 4000/2000/470 81 50 +5/+15/-15 0.4-5/0.15-2/0.1-1 4/1.5/0.5 4000/1500/470 83 51 +5/+24/+12 0.3-5/0.1-1.5/0.1-1.5 3/1/1 3000/1000/1000 85 Note: Use suffix “-Q” for conformal coating (ex. AMES50-051212TNZ -Q is conformal coating version). *Maximum duration 3sec when any of the outputs reaches its maximum working current. Total output power cannot exceed the rated power. Input Specifications Parameters Input current Inrush current F 052e R4 Rev: 03/21/A Conditions Single output, 115VAC Single output, 230VAC Others, 115VAC Others, 230VAC Single output, cold start, 115VAC Single output, cold start, 230VAC Others, cold start, 115VAC Others, cold start, 230VAC www.Aimtec.com Typical 30 50 30 50 Maximum Units 1.2 0.8 1.3 0.8 A A A A A A A A 2 AMES50-NZ AC-DC Converter Leakage current Single output, 240VAC others, 240VAC 0.75 2.0 mA mA Maximum Units Output Specifications Parameters Conditions Typical Single output, Full load, 5V output ±2 % Single output, Full load, Others ±1 % Dual output, Full load, Output 1 ±2 % Dual output, Full load, AMES50-0512DNZ, Output 2 ±8 % Dual output, Full load, AMES50-0524DNZ, Output 2 ≥ -4 +8 % Voltage accuracy Tri output, Full load, Output 1 ±2 % Tri output, Full load, AMES50-051212TNZ, Output 2 ±6 % Tri output, Full load, Others, Output 2 ≥ -4 +8 % Tri output, Full load, AMES50-052412TNZ, Output 3 ±6 % Tri output, Full load, Others, Output 3 ±3 ±5 % Single output, Full load ±0.5 % Dual output, Full load, Output 1 ±0.5 % Dual output, Full load, Output 2 ±1.5 % Tri output, Full load, Output 1 ±0.5 % Line regulation Tri output, Full load, AMES50-052412TNZ, Output 2 ±2 % Tri output, Full load, Others, Output 2 ±1.5 % Tri output, Full load, AMES50-052412TNZ, Output 3 ±2 % Tri output, Full load, Others, Output 3 ±0.5 % Single output, 0-100% load, 5V output ±1 % Single output, 0-100% load, Others ±0.5 % Dual output, 10-100% load, Output 1 ±0.5 % Dual output, 10-100% load, Output 2 ±5 % Load regulation** Tri output, 10-100% load, Output 1 ±1 % Tri output, 10-100% load, Output 2 ±3 ±5 % Tri output, 10-100%, AMES50-052412TNZ, Output 3 ±4 % Tri output, 10-100% load, Others, Output 3 ±1 % Single output, 5V output 80 mV p-p Single output, 12V,15V output 120 mV p-p Single output, 24V output 150 mV p-p Single output, 36V,48V output 200 mV p-p Dual output, Output 1 80 mV p-p Dual output, AMES50-0512DNZ, Output 2 120 mV p-p Ripple & Noise* Dual output, AMES50-0524DNZ, Output 2 150 mV p-p Tri output, Output 1 80 mV p-p Tri output, AMES50-052412TNZ, Output 2 150 mV p-p Tri output, others, Output 2 120 mV p-p Tri output, Output 3 120 mV p-p Single output, 115VAC ≥8 ms Single output, 230VAC ≥ 30 ms Hold up time Others, 115VAC 5 ms Others, 230VAC 30 ms Output 1 of dual, tri output models 4.75 – 5.5 V Voltage adjustable range Dual, tri output 3 S Start-up delay time Dual, Tri output, 115/230VAC 30 mS Rise time * Ripple and Noise are measured at 20MHz bandwidth with a 47μF electrolytic capacitor and a 0.1μF ceramic capacitor. Please refer to the application note for specific details. ** Equal-scale load for dual and tri output models. F 052e R4 Rev: 03/21/A www.Aimtec.com 3 AMES50-NZ AC-DC Converter Isolation Specifications Parameters Tested I/O voltage Tested Input to GND voltage Tested Output to GND voltage Tested Vo1 to Vo2 voltage Resistance (I/O, I/O to GND) Conditions Typical 60 sec, leakage current < 10mA, Single output 60 sec, leakage current < 10mA, Dual, tri output 60 sec, leakage current < 10mA, Single, Dual, tri output 60 sec, leakage current < 10mA, Single output 60 sec, leakage current < 10mA, Dual, tri output Dual output models only 500VDC, Single output 500VDC, Dual, tri output Rated Units 4000 3000 2000 1250 500 500 50 100 VAC VAC VAC VAC VAC VDC MΩ MΩ Maximum Units General Specifications Parameters Conditions Typical Safety class Switching Frequency Class I Single output 65 KHz Single output, Auto recovery ≥ 110 200 % of Iout Over current protection Dual output, equal-scale load, Auto recovery ≥ 110 230 % of Iout Tri output, equal-scale load, Auto recovery ≥ 110 230 % of Iout Single output, 5V output, Voltage clamp or hiccup 6.3 VDC Single output, 12V output, Voltage clamp or hiccup 16.2 VDC Single output, 15V output, Voltage clamp or hiccup 21.75 VDC Over voltage protection Single output, 24V output, Voltage clamp or hiccup 33.6 VDC Single output, 36V output, Voltage clamp or hiccup 48.6 VDC Single output, 48V output, Voltage clamp or hiccup 60 VDC Dual, tri output, Voltage clamp 5.75 ≤ Output 1 ≤ 6.75 VDC Short circuit protection* Hiccup, Continuous, Auto recovery, Recovery time < 5 sec Operating temperature See derating graph -30 to +70 °C Storage temperature -40 to +85 °C Power consumption Single output 0.3 W Single output, -30°C to -25°C, 85VAC - 100VAC 5 % / °C Single output, 40 °C to 70 °C, 85VAC - 165VAC, 5V output 1.33 % / °C Single output, 50 °C to 70 °C, 165VAC - 264VAC, 5V output 2 % / °C Single output, 50 °C to 70 °C, 12/15/24V output 2 % / °C Power derating Single output, 85VAC - 100VAC 1.33 % / VAC Dual output, 45 °C to 70 °C 2 % / °C Tri output, 50 °C to 70 °C 2.5 % / °C Dual, tri output, 85VAC - 115VAC 0.66 % / VAC Dual, tri output, 120VDC - 160VDC 0.5 % / VDC Ambient temperature derating Operating altitude > 2000m 5 °C / 1000m Temperature coefficient ±0.03 % / °C Cooling Free air convection Non-condensing, Storage 95 % RH Humidity Non-condensing, Operating ≥ 20 90 % RH Case material Metal (1100 Aluminum, SGCC) Single output 180 g Weight Dual output 235 g Tri output 240 g Single output 3.90 x 3.23 x 1.18inch (99.0 x 82.0 x 30.0mm) Dimensions (L x W x H) Dual, tri output 3.90 x 3.82 x 1.18inch (99.0 x 97.0 x 30.0mm) MTBF > 300 000 hrs (MIL-HDBK -217F, t=+25°C) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity
AMES50-36SNZ 价格&库存

很抱歉,暂时无法提供与“AMES50-36SNZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货