AMES75-NZ
AC-DC Converter
Click to
ORDER
AMES75-NZ
samples
The new AMES75-NZ is a brand-new AC/DC converter that offers much greater cost
effectiveness due to material normalization and production automation also leading
to improved reliability and performance. Offering a commercial input voltage range
of 85-264VAC and an output voltage range from 5-48V, this series will offer many
benefits to your new system design.
This new series offers great operating temperatures, from -30℃ to 70℃ also features
an isolation of 4000VAC for improved reliability and system safety. Furthermore, a
higher MTBF of 300,000h, output short circuit protection (OSCP), output over-current
protection (OCP) and an output over-voltage protection (OVP) come standard with
the series.
The AMES75-NZ is perfect for street lighting controls, grid power, LED,
instrumentation, industrial controls, communication and civil applications.
Enclosed
Summary
Features
•
•
•
•
•
•
Universal Input: 85 - 264VAC/120 - 373VDC
Operating Temp: -30 °C to +70 °C
High isolation voltage: Up to 4000VAC
Low ripple & noise, 150mV(p-p).
Output short circuit, over-current, over-voltage
protection
Regulated Output
AMES75-NZ
528
4000
48
100
76.8
3000
300
264
85
0
125
125
69.6
70
40
1000
5
3.3
1
Input voltage Output voltage
(VAC)
(V)
Isolation
(VAC)
Power
(W)
-30
-30
Temp. range
(℃)
Derating
(℃)
Applications
Training
Press Release
Coming Soon!
Power Grid
Product Training Video
(click to open)
F 052e R4
Rev: 02/21/A
Industrial
Telecom
Instrumentation
Application Notes
www.Aimtec.com
1
AMES75-NZ
AC-DC Converter
Models & Specifications
Single Output
Model
AMES75-5SNZ#
AMES75-12SNZ#
AMES75-15SNZ#
AMES75-24SNZ#
AMES75-36SNZ#
AMES75-48SNZ#
Input
Voltage
(VAC/Hz)
Input
Output
Max Output
Voltage
Voltage
Wattage (W)
(VDC)
(V)
Output Voltage
Adjustable Range
(V)
Output
Current
max (A)
Maximum
capacitive load
(µF)
Efficiency
@230VAC
Typ. (%)
85-264/47-63
120-373
70
5
4.5-5.5
14
10000
86
85-264/47-63
120-373
72
12
10.2-13.8
6
6000
88
85-264/47-63
120-373
75
15
13.5-18
5
5000
88
85-264/47-63
120-373
76.8
24
21.6-28.8
3.2
1500
90
85-264/47-63
120-373
75.6
36
32.4-39.6
2.1
1000
90
85-264/47-63 120-373
76.8
48
43.2-52.8
1.6
680
91.5
Note: Add suffix “-P” for optional terminal protective cover (ex. AMES75-5SNZ-P is terminal with protective cover version) or suffix “-Q” for
conformal coating (ex. AMES75-5SNZ-Q is conformal coating version).
Dual Output
Model
AMES75-0512DNZ#
AMES75-0524DNZ#
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
Wattage
(W)
Output
Voltage
(Vo1/Vo2)
(V)
Working Current
Range
(Io1/Io2)
(A)*
Output
Current
(Io1/Io2)
(A)
Maximum
capacitive load
(Vo1/Vo2)
(µF)
Efficiency
@230VAC
(%)
90-264/47-63
120-373
71
5/12
0.7-8/0.3-4
7/3
7000/3000
82
90-264/47-63 120-373
73
5/24
0.5-6/0.2-3
5/2
5000/2000
84
Note: Use suffix “-Q” for conformal coating (ex. AMES75-0512DNZ -Q is conformal coating version).
*Maximum duration 3sec when any of the outputs reaches its maximum working current. Total output power cannot exceed the rated power.
Tri Output
Model
AMES75-051212TNZ
AMES75-051515TNZ
AMES75-052412TNZ
Max
Output
Output
Voltage
Wattage (Vo1/Vo2/
(W)
Vo3) (V)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
90-264/47-63
120-373
69.6
90-264/47-63
120-373
72
Working Current
Range
(Io1/Io2/Io3)
(A)
Output
Current
(Io1/Io2/
Io3) (A)
Maximum
capacitive load
(Vo1/Vo2/Vo3)
(µF)
Efficiency
@230VAC
(%)
+5/+12/-12
0.6-7/0.28-3.5/0.05-1
6/2.8/0.5
6000/2800/470
82
+5/+15/-15
0.6-7/0.23-3.5/0.05-1
6/2.3/0.5
6000/2300/470
82
90-264/47-63 120-373
73
+5/+24/+12 0.5-6/0.15-2/0.1-1.5
5/1.5/1
5000/1500/1000
84
Note: Use suffix “-Q” for conformal coating (ex. AMES75-051212TNZ -Q is conformal coating version).
*Maximum duration 3sec when any of the outputs reaches its maximum working current. Total output power cannot exceed the rated power.
Parameters
Input current
Inrush current
Leakage current
F 052e R4
Rev: 02/21/A
Conditions
Single output, 115VAC
Single output, 230VAC
Others, 115VAC
Others, 230VAC
Single output, cold start, 115VAC
Single output, cold start, 230VAC
Others, 115VAC
Others, 230VAC
Single output, 240VAC
others, 240VAC
www.Aimtec.com
Typical
40
65
30
45
Maximum
Units
2
1
1.7
0.9
A
A
A
A
A
A
A
A
mA
mA
50
0.75
2.0
2
AMES75-NZ
AC-DC Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Single output, Full load, 5V output
±2
%
Single output, Full load, Others
±1
%
Dual output, Full load, Output 1
±2
%
Dual output, Full load, Output 2
±8
%
Tri output, Full load, Output 1
±2
%
Voltage accuracy
Tri output, Full load, AMES75-051515TNZ, Output 2
≥ -4
+8
%
Tri output, Full load, Others, Output 2
±6
%
Tri output, Full load, AMES75-052412TNZ, Output 3
±6
%
Tri output, Full load, Others, Output 3
±5
%
Single output, Full load
±0.5
%
Dual output, Full load, Output 1
±0.5
±1
%
Dual output, Full load, Output 2
±1.5
%
Tri output, Full load, Output 1
±1
%
Line regulation
Tri output, Full load, Output 2
±1
%
Tri output, Full load, AMES75-052412TNZ, Output 3
±2
%
Tri output, Full load, others, Output 3
±1
%
Single output, 0-100% load, 5V output
±1
%
Single output, 0-100% load, Others
±0.5
%
Dual output, 10-100% load, Output 1
±0.5
%
Dual output, 10-100% load, Output 2
±5
%
Load regulation**
Tri output, 10-100% load, Output 1
±1
%
Tri output, 10-100% load, Output 2
±5
%
Tri output, 10-100% load, AMES75-052412TNZ, Output 3
±5
%
Tri output, 10-100% load, others, Output 3
±1
%
Single output, 5V output
100
mV p-p
Single output, 12V,15V output
120
mV p-p
Single output, 24V output
150
mV p-p
Single output, 36V,48V output
200
mV p-p
Dual output, Output 1
80
mV p-p
Dual output, AMES75-0512DNZ, Output 2
120
mV p-p
Ripple & Noise*
Dual output, AMES75-0524DNZ, Output 2
150
mV p-p
Tri output, Output 1
80
mV p-p
Tri output, AMES75-051212TNZ, Output 2
120
mV p-p
Tri output, others, Output 2
150
mV p-p
Tri output, AMES75-052412TNZ, Output 3
150
mV p-p
Tri output, others, Output 3
80
mV p-p
Single output, 115VAC
8
ms
Single output, 230VAC
55
ms
Hold up time
Others, 115VAC
5
ms
Others, 230VAC
30
ms
Output 1 of dual, tri output models
4.75 – 5.5
V
Voltage adjustable range
Dual,
tri
output
3
S
Switching delay time
Dual output, 115/230VAC
30
mS
Rise time
Tri output, 115/230VAC
100
mS
* Ripple and Noise are measured at 20MHz bandwidth with a 47μF electrolytic capacitor and a 0.1μF ceramic capacitor. Please refer to the
application note for specific details.
** Balanced load for dual and tri output models.
F 052e R4
Rev: 02/21/A
www.Aimtec.com
3
AMES75-NZ
AC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Tested Input to GND voltage
Tested Output to GND voltage
Tested Vo1 to Vo2 voltage
Resistance (I/O, I/O to GND)
Conditions
Typical
60 sec, leakage current < 10mA, Single output
60 sec, leakage current < 10mA, Dual, tri output
60 sec, leakage current < 10mA, Single output
60 sec, leakage current < 10mA, Dual, tri output
60 sec, leakage current < 10mA, Single output
60 sec, leakage current < 10mA, Dual, tri output
Dual output model only
500VDC
Rated
Units
4000
3000
2000
2000
1250
500
500
100
VAC
VAC
VAC
VAC
VAC
VAC
VDC
MΩ
Maximum
Units
General Specifications
Parameters
Conditions
Typical
Safety class
Switching Frequency
Class I
Single output
65
KHz
Single output, Auto recovery
≥ 110
200
% of Iout
Over Current protection
Dual, tri output, balanced load, Auto recovery
≥ 110
% of Iout
Single output, 5V output, Manual recovery
6.3
VDC
Single output, 12V output, Voltage clamp
16.2
VDC
Single output, 15V output, Voltage clamp
21.75
VDC
Single output, 24V output, Voltage clamp
33.6
VDC
Over voltage protection
Single output, 36V output, Voltage clamp
50
VDC
Single output, 48V output, Manual recovery
60
VDC
Dual, tri output, Hiccup
5.75 ≤ Output 1 ≤ 6.75
VDC
Hiccup, Continuous, Auto recovery, Recovery time < 5 sec
Short circuit protection*
See derating graph
-30 to +70
°C
Operating temperature
-40 to +85
°C
Storage temperature
Single output
0.3
W
Power consumption
Single output, 40 °C to 70 °C, 5V output
1.3
% / °C
Single output, 50 °C to 70 °C, Others
2
% / °C
Single output, 85VAC ~ 100VAC
1.33
% / VAC
Dual output, 45 °C to 70 °C
2
% / °C
Power derating
Tri output, 40 °C to 70 °C
2
% / °C
Dual, tri output, 90VAC - 115VAC
0.8
% / VAC
Dual, tri output, 120VDC - 160VDC
0.5
% / VAC
Single output models and Output 1 of dual, tri output models
±0.03
% / °C
Temperature coefficient
Free air convection
Cooling
Non-condensing
≥ 10
95
% RH
Humidity
Non-condensing, Operating
≥ 20
90
% RH
Metal (1100 Aluminum, Hot dip galvanized steel)
Case material
Single output
220
g
Dual output
310
g
Weight
Tri output
320
g
Single output
3.90 x 3.82 x 1.18inch (99.0 x 97.0 x 30.0mm)
Dimensions (L x W x H)
Dual, tri output
5.07 x 3.82 x 1.18inch (129.0 x 97.0 x 30.0mm)
> 300 000 hrs (MIL-HDBK -217F, t=+25°C)
MTBF
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity