AMES75-277NZ
AC-DC Converter
Click to
ORDER
AMES75-277NZ
samples
The AMES75-277NZ is an enclosed AC/DC converter that offers much greater cost
effectiveness due to material normalization and production automation also leading
to improved reliability and performance. Offering a wide input voltage range of 85305VAC and an output voltage range from 5-48V, this series will offer many benefits
to your new system design.
This series offers great operating temperatures, from -30℃ to 70℃ and also features
an isolation of 4000VAC for improved reliability and system safety. Furthermore, a
high MTBF of 300,000h, output short circuit protection (OSCP), output over-current
protection (OCP) and an output over-voltage protection (OVP) come standard with
the series.
The AMES75-277NZ is suitable for street lighting controls, grid power,
instrumentation, industrial controls, communication and civil applications.
Enclosed
Summary
Features
•
•
•
•
•
•
Universal Input: 85 - 305VAC/120 - 430VDC
Operating Temp: -30 °C to +70 °C
High isolation voltage: Up to 4000VAC
Low ripple & noise: Up to 100mV(p-p) typ.
Output short circuit, over-current, over-voltage
protection
Regulated Output
AMES75-277NZ
528
48
4000
100
125
76.8
70
305
70
70
1000
85
0
40
5
3.3
1
-30
-40
Input voltage Output voltage
(VAC)
(V)
Isolation
(VAC)
Power
(W)
-25
-30
Temp. range
(℃)
Derating
(℃)
Applications
Training
Press Release
Coming Soon!
Power Grid
Product Training Video
(click to open)
F 052e R4
Rev: 02/21/A
Industrial
Telecom
Instrumentation
Application Notes
www.Aimtec.com
1
AMES75-277NZ
AC-DC Converter
Models & Specifications
Single Output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
85-305/47-63
120-430
70
5
85-305/47-63
120-430
72
12
85-305/47-63
120-430
75
15
85-305/47-63
120-430
76.8
24
85-305/47-63
120-430
75.6
36
32.4-39.6
AMES75-5S277NZ
AMES75-12S277NZ
AMES75-15S277NZ
AMES75-24S277NZ
AMES75-36S277NZ
AMES75-48S277NZ
Output Output Voltage
Max Output
Voltage
Adjustable
Wattage (W)
(V)
Range (V)
Output
Current
max (A)
Maximum
capacitive
load (µF)
Efficiency
@230VAC
Typ. (%)
4.5-5.5
14
10000
85
10.2-13.8
6
6000
87
13.5-18
5
5000
87
21.6-28.8
3.2
1500
89
2.1
1000
89
85-305/47-63
120-430
76.8
48
43.2-52.8
1.6
680
90.5
Note: Use suffix “-P” for terminal with protective cover (ex. AMES75-5S277NZ-P is terminal with protective cover version) and suffix “-Q” for
conformal coating (ex. AMES75-5S277NZ-Q is conformal coating version).
Input Specifications
Parameters
Input current
Inrush current
Leakage current
Conditions
115VAC
230VAC
cold start, 115VAC
cold start, 230VAC
277VAC
Typical
Maximum
Units
2
1
0.75
A
A
A
A
mA
Maximum
Units
40
75
Output Specifications
Parameters
Conditions
Typical
Full load range, 5V output
±2
%
Full load range, Others
±1
%
%
Rated load
±0.5
Line regulation
0-100% load, 5V output
±1
%
Load regulation
0-100% load, Others
±0.5
%
5V output
100
mV p-p
12V,15V output
120
mV p-p
Ripple & Noise*
24V output
150
mV p-p
36V,48V output
200
mV p-p
115VAC
8
ms
Hold up time
230VAC
55
ms
* Ripple and Noise are measured at 20MHz bandwidth. Please refer to the application note for specific details. Measured with 47μF electrolytic
capacitor and 0.1μF ceramic capacitor.
Voltage accuracy
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Tested Input to GND voltage
Tested Output to GND voltage
Resistance (I/O, I/O to GND)
60 sec, leakage current < 10mA
60 sec, leakage current < 10mA
60 sec, leakage current < 10mA
500VDC
F 052e R4
Rev: 02/21/A
www.Aimtec.com
Typical
Rated
Units
4000
2000
1250
100
VAC
VAC
VAC
MΩ
2
AMES75-277NZ
AC-DC Converter
General Specifications
Parameters
Conditions
Safety class
Switching Frequency
Typical
Maximum
Units
Class I
65
KHz
230VAC, Rated load, Normal or high temperature, Auto recovery
≥ 110
200
% of Iout
Over Current protection
230VAC, Rated load, Low temperature, Auto recovery
≥ 110
% of Iout
5V output, Hiccup, Auto recovery
6.3
VDC
12V output, Hiccup, Auto recovery
16.2
VDC
15V output, Hiccup, Auto recovery
21.75
VDC
Over voltage protection
24V output, Hiccup, Auto recovery
33.6
VDC
36V output, Hiccup, Auto recovery
50
VDC
48V output, Hiccup, Auto recovery
60
VDC
Hiccup, Continuous, Auto recovery, Recovery time < 5 sec
Short circuit protection
See derating graph
-30 to +70
°C
Operating temperature
-40 to +85
°C
Storage temperature
0.5
W
Power consumption
40 °C to 70 °C, 5V output
1.3
% / °C
50 °C to 70 °C, Others output
2
% / °C
Power derating
85VAC ~ 100VAC
1.33
% / VAC
277VAC ~ 305VAC
0.71
% / VAC
0 °C to 50 °C, 230VAC
±0.03
% / °C
Temperature coefficient
Free air convection
Cooling
Operating, Non-condensing
> 20
90
% RH
Humidity
Storage, Non-condensing
95
% RH
Metal (1100 Aluminum, SGCC)
Case material
220
g
Weight
3.90 x 3.82 x 1.18inch (99.0 x 97.0 x 30.0mm)
Dimensions (L x W x H)
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)
MTBF
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity