AMESP75-277NZ
AC-DC Converter
Click to
ORDER
AMESP75-277NZ
samples
The AMESP75-277NZ is an AC/DC converter that offers greater cost effectiveness due
to material normalization and production automation also leading to improved
reliability and performance. Offering a commercial input voltage range of 85-305VAC
and an output voltage range from 5-48V, this series will offer many benefits to your
new system design.
This new series offers great operating temperatures, from -30℃ to 70℃ and also
features an isolation of 4000VAC for improved reliability and system safety.
Furthermore, a high MTBF of 300,000h, output short circuit protection (OSCP), output
over-current protection (OCP), output over-voltage protection (OVP) and an overtemperature protection (OTP) come standard with the series.
The AMESP75-277NZ is suitable for EV supply equipment, grid power, household
appliance, instrumentation, industrial controls and civil applications.
Enclosed
Features
•
•
•
•
•
•
Summary
Universal Input: 85 - 305VAC/120 - 430VDC
Operating Temp: -30 °C to +70 °C
High isolation voltage: Up to 4000VAC
Low ripple & noise: 200mV(p-p).
Output short circuit, over-current, over-voltage,
over-temperature protection
Regulated Output
AMESP75-277NZ
528
48
4000
150
125
305
76.8
75
85
0
70
70
40
-30
-40
-20
Temp. range
(℃)
Derating
(℃)
1000
5
3.3
1
Input voltage Output voltage
(VAC)
(V)
Isolation
(VAC)
Power
(W)
-30
Applications
Training
Press Release
Coming Soon!
Power Grid
Product Training Video
(click to open)
F 052e R4
Industrial
Telecom
Instrumentation
Application Notes
www.Aimtec.com
1
AMESP75-277NZ
AC-DC Converter
Models & Specifications
Single Output
Model
AMESP75-5S277NZ
AMESP75-12S277NZ
AMESP75-15S277NZ
AMESP75-24S277NZ
AMESP75-48S277NZ
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
120-430
120-430
120-430
120-430
Output Output Voltage
Max Output
Voltage
Adjustable
Wattage (W)
(V)
Range (V)
75
75.6
75
76.8
5
12
15
24
4.75-5.5
11.4-13.2
14.3-16.5
22.8-26.4
Output
Current
max (A)
Maximum
capacitive
load (µF)
Efficiency
@230VAC
Typ. (%)
15
6.3
5
3.2
10000
6800
5000
1500
81
84
85
86
85-305/47-63
120-430
76.8
48
45.6-52.8
1.6
680
88
Note: Use suffix “-P” for terminal with protective cover (ex. AMESP75-5S277NZ-P is terminal with protective cover version) and suffix “-Q” for
conformal coating (ex. AMESP75-5S277NZ-Q is conformal coating version).
Input Specifications
Parameters
Input current
Inrush current
Power factor
Leakage current
Conditions
115VAC
230VAC
cold start, 115VAC
cold start, 230VAC
115VAC, Full load
230VAC, Full load
277VAC/60Hz
Typical
Maximum
Units
1
0.6
A
A
A
A
2
mA
Maximum
Units
20
35
>0.98
>0.93
Output Specifications
Parameters
Conditions
Typical
%
Full load range, 5V output
±2
%
Rated load
±0.5
0-100% load, 5V output
±1
%
Load regulation
0-100% load, Others
±0.5
%
Others
120
mV p-p
Ripple & Noise*
48V output
200
mV p-p
230VAC
16
ms
Hold up time
Full load
3
S
Start up time
Power ON
≥0
0.8
VDC
Remote control
Power OFF
≥4
10
VDC
* Ripple and Noise are measured at 20MHz bandwidth. Please refer to the application note for specific details. Measured with 47μF electrolytic
capacitor and 0.1μF ceramic capacitor.
Voltage accuracy
Line regulation
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Tested Input to GND voltage
Tested Output to GND voltage
Resistance (I/O, I/O to GND)
60 sec, leakage current < 10mA
60 sec, leakage current < 10mA
60 sec, leakage current < 5mA
500VDC
F 052e R4
www.Aimtec.com
Typical
Rated
Units
4000
2000
500
100
VAC
VAC
VAC
MΩ
2
AMESP75-277NZ
AC-DC Converter
General Specifications
Parameters
Conditions
Safety class
Switching Frequency
Over Current protection
Typical
Maximum
Units
Class I
65
KHz
Auto recovery
≥ 105
% of Iout
5V output, Clamp or hiccup, Auto recovery
7
VDC
12V output, Clamp or hiccup, Auto recovery
20
VDC
15V output, Clamp or hiccup, Auto recovery
25
VDC
Over voltage protection
24V output, Clamp or hiccup, Auto recovery
32.4
VDC
48V output, Clamp or hiccup, Auto recovery
60
VDC
Activation
85
°C
Over temperature protection
Deactivation
50
°C
Hiccup, Continuous, Auto recovery, Recovery time < 3 sec after short have been released
Short circuit protection
See derating graph, for 5V model only
-30 to +60
°C
Operating temperature
See derating graph, ohters
-30 to +70
°C
-40 to +85
°C
Storage temperature
-30 °C to -20 °C, 85VAC ~ 230VAC
4
% / °C
40 °C to 60 °C, 5V output
2
% / °C
50 °C to 70 °C, Others
2
% / °C
Power derating
85VAC ~ 100VAC
1.33
% / VAC
100VAC ~ 305VAC
0
% / VAC
2000m ~ 5000m
5
% / Km
±0.03
% / °C
Temperature coefficient
Free air convection
Cooling
Non-condensing
95
% RH
Humidity
5000
m
Altitude
Metal (1100 Aluminum, SGCC)
Case material
380
g
Weight
6.26 x 3.82 x 1.18inch (159.0 x 97.0 x 30.0mm)
Dimensions (L x W x H)
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)
MTBF
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity