GaAs Hall Element
HG-0113
Shipped in packet-tape reel(5,000pcs per reel)
Notice : It is requested to read and accept "IMPORTANT NOTICE"
written on the back of the front cover of this catalogue.
●Absolute Maximum Ratings
Item
Symbol
Limit
Unit
Max. Input Voltage
VC
12
V
Max.Input Power
PD
150
mW
Operating Temp. Range Topr.
−40 ∼ +125
℃
Tstg.
−40 ∼ +150
℃
Storage Temp. Range
●Dimensional Drawing(Unit : mm)
●Electrical Characteristics(Ta=25℃)
Typ.
Max.
Unit
Output Hall Voltage
VH
B=50mT, Vc=6V
Input Resistance
Rin
B=0mT,Ⅰc=0.1mA
1,000 1,250 1,500
Ω
Output Resistance Rout B=0mT,Ⅰc=0.1mA
1,800 2,500 3,000
Ω
102
78
mV
0.3
Min.
0.3
Sensor
Center
2
3
φ0.2
1.05
※
Conditions
1.6±0.1
Symbol
3
Item
+0
0.5−0.1
0.8±0.1
CL
5
N
4
1
※
αVH
B=50mT,Ⅰc=1mA
Ta=25∼125℃
※
mV
−0.06
%/℃
0.3
%/℃
2
%
※
Linearity
ΔK
B=0.1/0.5T,Ⅰc=1mA
3.
4.
0.15
Pin 5 is short to pin 3 inside the package.
Pinning
CL
Notes : 1. VH = VHM – Vos(Vu) (VHM:meter indication)
2.
Sensor
Center
0.3
B=0mT,Ⅰc=0.1mA
Temp. Coefficient of Rin αRin
Ta=25∼125℃
8
+0
0.5−0.1
Temp. Coefficient of VH
−8
1
2) – VH (T1)
X 100
VH = VH (T1) X VH (T
(T2 – T1)
1
Rin (T2) – Rin (T1)
X 100
Rin = Rin (T1) X
(T2 – T1)
1) – K (B2)
K = [K K(B(B
X
100
1) + K (B2)] / 2
Input
1(±)
3( )
Output
2(±)
4( )
±
Vos(Vu) B=0mT, Vc=6V
±
Offset Voltage
T1 = 25˚C, T2 = 125˚C
K=
VH
IC • B
●Land pattern (for reference only)(Unit : mm)
B1 = 0.5T, B2 = 0.1T
●Characteristic Curves
Allowable Package Power Dissipation
160
0.35
Max. Input Power:PD [mW]
0.70
1.05
200
120
0.30
0.55
80
40
0
0
20
40
60
80
100
Ambient Temperature(˚C):Ta [℃]
44
120
140
0.30
HG-0113
•Please be aware that our products are not intended for use in life support equipment, devices, or systems. Use of our products in such applications requires the
advance written approval of our sales staff.
Certain applications using semiconductor devices may involve potential risks of personal injury, property damage, or loss of life. In order to minimize these risks,
adequate design and operating safeguards should be provided by the customer to minimize inherent or procedural hazards. Inclusion of our products in such
applications is understood to be fully at the risk of the customer using our devices or systems.
•Handling precautions required for preventing electrostatic discharge.
•This product contains galium arsenide(GaAs).Handling and discarding precautions required.
●Characteristic Curves
Rin-T
800
Output Hall Voltage:VH [mV]
1600
Input Resistance:Rin [Ω]
b
VH-B
1800
1400
1200
1000
800
600
400
Ic const
700
Vc const
600
lc =5 [mA]
Vc = 6 [V]
Ta =25 [℃]
500
400
0
–50
0
50
100
200
0
0
150
VH-T
100
200
Magnetic Flux Density:B [mT]
300
VH-Vc,VH-Ic
120
Ic
100
80
Vc
60
Ic const
40
lc =5 [mA]
Vc = 6 [V]
B =50 [mT]
Vc const
20
Output Hall Voltage:VH[mV]
160
140
Output Hall Voltage:VH[mV]
c
300
Ambient Temperature:Ta [℃]
Ic const
140
Vc const
120
Ic
B =50 [mT]
Ta =25 [℃]
100
Vc
80
60
g
40
20
0
0
−50
0
50
100
150
0
2
8
8
10
i
10
Ic const
7
Ic const
6
Vc const
lc =5 [mA]
Vc =6 [V]
B =0 [mT]
4
6
Vos(Vu)-Vc, Vos(Vu)-Ic(For reference only)
Vos(Vu)-T(For reference only)
5
4
Input Current:Ic[mA]
Input Voltage:Vc[V]
Ambient Temperature.Ta[℃]
Offset Voltage:Vos [mV]
Vc,
100
200
3
Ic
8
Vc const
6
B = 0 [mT]
Ta =25 [℃]
4
Ic
Vc
2
1
0
-50
2
Ic
0
50
100
150
Ambient Temperature:Ta [℃]
※Magnetic Flux Density
1[mT]=10[G]
0
Vc
k
0
2
4
6
Input Current:Ic [mA]
Input Voltage:Vc [V]
8
10
In This Example : Rin=1270〔Ω〕, Vos=2.1〔mV〕, [Vc=6〔V〕]
45
IMPORTANT NOTICE
These products and their specifications are subject to change without notice.
When you consider any use or application of these products, please make
inquiries the sales office of Asahi Kasei Microdevices Corporation (AKM) or
authorized distributors as to current status of the products.
Descriptions of external circuits, application circuits, software and other related
information contained in this document are provided only to illustrate the
operation and application examples of the semiconductor products. You are
fully responsible for the incorporation of these external circuits, application
circuits, software and other related information in the design of your
equipments. AKM assumes no responsibility for any losses incurred by you or
third parties arising from the use of these information herein. AKM assumes no
liability for infringement of any patent, intellectual property, or other rights in
the application or use of such information contained herein.
Any export of these products, or devices or systems containing them, may
require an export license or other official approval under the law and
regulations of the country of export pertaining to customs and tariffs, currency
exchange, or strategic materials.
AKM products are neither intended nor authorized for use as critical
componentsNote1) in any safety, life support, or other hazard related device or
systemNote2), and AKM assumes no responsibility for such use, except for the
use approved with the express written consent by Representative Director of
AKM. As used here:
Note1) A critical component is one whose failure to function or perform
may reasonably be expected to result, whether directly or indirectly, in the
loss of the safety or effectiveness of the device or system containing it,
and which must therefore meet very high standards of performance and
reliability.
Note2) A hazard related device or system is one designed or intended for
life support or maintenance of safety or for applications in medicine,
aerospace, nuclear energy, or other fields, in which its failure to function
or perform may reasonably be expected to result in loss of life or in
significant injury or damage to person or property.
It is the responsibility of the buyer or distributor of AKM products, who
distributes, disposes of, or otherwise places the product with a third party, to
notify such third party in advance of the above content and conditions, and
the buyer or distributor agrees to assume any and all responsibility and
liability for and hold AKM harmless from any and all claims arising from the
use of said product in the absence of such notification.
June 2, 2010