PCN Number: SM010917
Chgnot.doc rev 13 1/14
Product/Process Change Notification (PCN)
Customer: Digi-Key
Date: 01/09/2017
Customer Part # and/or Lot# affected: A5940GLKTR-T, A5940GLNTR-T,
A5940KLKTR-T, A5941GLKTR-T, A5941GLNTR-T, A5941KLKTR-T, A5933GLKTR-T,
A5933GLNTR-T and A5933GEJTR-T
Originator: Scott Mitti
Phone: 508-854-5627
Duration of Change:
Summary description of change: Part Change:
Permanent X
Temporary (explain)
Process Change: X
Other:
The A5940GLKTR-T, A5940GLNTR-T, A5940KLKTR-T, A5941GLKTR-T, A5941GLNTR-T,
A5941KLKTR-T, A5933GLKTR-T, A5933GLNTR-T and A5933GEJTR-T devices will have an
additional final test location: Allegro MicroSystems (Thailand) Co., Ltd. (AMTC).
What is the part or process changing from (provide details)?
In addition to the current Allegro MicroSystems, LLC test facility location in Manila Philippines, a
second test facility referred to as Allegro MicroSystems (Thailand) Co., Ltd. (AMTC) located in
Saraburi, Thailand will be added as the primary test location.
What is the part or process changing to (describe the anticipated impact of this change on
form, fit and/or function)?
Allegro will be expanding its manufacturing capabilities with the addition of a new, wholly-owned
integrated circuit test facility located in Saraburi, Thailand. The same make and model test
equipment will be utilized and test site transfer buy off data will be on file for each device before
production begins.
Note: Validation of equivalence within a specific application is at the discretion of the
Customer
PCN Number: SM010917
Chgnot.doc rev 13 1/14
Is a PPAP update required?
Yes
Is reliability testing required?
(If Yes, refer to attached plan)
Yes
No
X
No (explain)
X
Expected completion date for internal qualification: Complete
Expected PPAP availability date: N/A
Target implementation date: July 2017
Estimated date of first shipment: August 2017
Expected sample availability date: Available Upon Request
Yes
Customer Approval Required:
No
Date Required:
X
Notification Only
Please note: It is our intention to inform our customer of changes as early as possible. Under
Allegro’s procedure for product/process change notification, Allegro strives, based on its
technical judgment, to provide notification of significant changes that may affect form, fit
or function. However, as Allegro cannot ensure evaluation of product/process changes
for each and every application; the customer retains responsibility to validate the impact of
a change on its application suitability. If samples are needed for validation of a change,
requests may be made via the contact information provided herein. Please contact your
Account Manager or local Sales contact for any questions. We would kindly request your
consideration so we can meet our target date for implementation. Unless both parties agree to
extend the implementation date, this change will be implemented as scheduled.
Customer comments/Conditions of Acceptance:
Approved by:
Date:
cc: Allegro Sales/Marketing/Quality
Title: