0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ASEK764XLF-16AU-T-KIT-DK

ASEK764XLF-16AU-T-KIT-DK

  • 厂商:

    ALLEGRO(埃戈罗)

  • 封装:

  • 描述:

    ACS764 - 电流传感器 评估板 - 传感器

  • 数据手册
  • 价格&库存
ASEK764XLF-16AU-T-KIT-DK 数据手册
ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC With I2C Digital Output and Low-Resistance Current Conductor Discontinued Product This device is no longer in production. The device should not be purchased for new design applications. Samples are no longer available. Date of status change: December 5, 2016 Recommended Substitutions: no direct replacement For existing customer transition, and for new customers or new applications, contact Allegro Marketing. NOTE: For detailed information on purchasing options, contact your local Allegro field applications engineer or sales representative. Allegro MicroSystems, LLC reserves the right to make, from time to time, revisions to the anticipated product life cycle plan for a product to accommodate changes in production capabilities, alternative product availabilities, or market demand. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, LLC assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use. ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC With I2C Digital Output and Low-Resistance Current Conductor Description Features and Benefits The Allegro™ ACS764 fully integrated Hall-effect current sensor IC is designed for applications that require digital current sensing and reporting through an I2C™ bus. Allegro factory programming of the offset and gain, including the temperature coefficients, stabilizes the offset and gain over the operating temperature range. This programming greatly reduces the device total error, typically less than 2% over the operating temperature range. A fast response digital fault output is also provided. Both coarse sensitivity and fault level can be programmed via an I2C control register, and can be used for enhanced diagnostic functions. • Fully integrated current sensor IC in a compact QSOP package eliminates the need for shunt resistors • Hall effect sensing technology eliminates the error associated with shunt resistor variation due to temperature • High accuracy: typical error < 2% over operating temperature range • Fast response digital fault output with programmable level through I2C bus interface • Digital output through I2C interface with 9-bit A-to-D conversion for high resolution current measurement • User-selectable decimation averaging of current output; up to 256 samples • Freeze pin for holding current measurement value while reading many sensors serially • User-selectable (via I2C) coarse sensitivity and OC fault levels, for exceptional flexibility to meet application requirements The integrated low resistance conductor eliminates the requirement for external shunt resistors and, by employing Hall-effect sensing technology, eliminates the error associated with changing sense resistance due to temperature. The device allows 16 unique I2C bus addresses, selectable via external pins. The sensor IC gain can be selected by the user through the I2C bus. The device uses a BiCMOS process that allows a highly stable chopper-stabilized small signal amplifier design. Continued on the next page… Package: 24-pin QSOP (suffix LF) The ACS764 is provided in a compact 24-pin QSOP package (suffix LF). The leadframe is plated with 100% matte tin, which is compatible with standard lead (Pb) free printed circuit board assembly processes. Internally, the device is Pb-free, except for flip-chip high-temperature Pb-based solder balls, currently exempt from RoHS. Not to scale Typical Application Diagrams IP 1 2 3 4 5 6 +3.3 V CBYP 0.1 μF 7 8 9 10 11 12 ACS764-DS IP+ IP– IP+ IP– IP+ IP+ IP+ IP– ACS764 (I2C Slave) IP– IP– IP+ IP– IP+ IP– VCC A1 SDA A0 SCL FAULT GND FREEZE NC NC 24 23 22 21 VCC 20 VA1 19 VCC 18 17 16 15 14 13 VCC RPU VA0 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Features and Benefits (continued) • Less than 0.5 mΩ series resistance greatly reduces power dissipation and heat generation • Factory programmed temperature compensation stabilizes sensitivity and offset voltage throughout the operating temperature range • 16 programmable I2C addresses • Unidirectional DC current sensing and reporting • Immunity to stray magnetic fields simplifies PCB layout Selection Guide Part Number Packing* ACS764XLFTR-32AU-T Tape and reel, 2500 pieces/reel ACS764XLFTR-16AU-T Tape and reel, 2500 pieces/reel *Contact Allegro™ for additional packing options. Operating Ambient Temperature,TA (°C) Optimized Current Sensing Range (A) Optimized Nominal Resolution (mA/LSB) –20 to 125 –20 to 125 32 16 62.62 31.31 Absolute Maximum Ratings Characteristic Forward Supply Voltage Symbol Notes Rating Unit VCC 7 V ¯¯A¯¯U¯¯ ¯¯T ¯ Pin Voltage Forward ¯F L VFAULT 24 V DC Forward Voltage (A0, A1, FREEZE pins) VFDCx 7 V DC Reverse Voltage (VCC, A0, A1, ¯F ¯¯A¯¯U¯¯ ¯¯T ¯, FREEZE pins) L VRDCx –0.5 V –20 to 125 ºC Operating Ambient Temperature TA Maximum Junction Temperature TJ(max) 165 ºC Tstg –65 to 165 ºC Storage Temperature X temperature range Thermal Characteristics Characteristic Steady State Package Thermal Resistance Symbol RθJA Test Conditions Value Unit Tested with 30 A DC current and based on ACS764 demo board in 1 cu. ft. of still air. Please refer to product FAQs page on Allegro website for detailed information on ACS764 demo board. 27 ºC/W Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 2 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 Functional Block Diagram VCC To all subcircuits Master Current Supply POR and Reset Hall Drive Fault Logic Dynamic Offset Cancellation IP+ CBYPASS Tuned Filter Sensitivity Control IP– FAULT ADC Offset Control Data Averaging FREEZE I2C Interface SDA SCL EEPROM Digital Controller Temperature Sensor A0 A1 GND Terminal List Table Pin-out Diagram IP+ 1 24 IP– IP+ 2 23 IP– IP+ 3 22 IP– IP+ 4 21 IP– IP+ 5 20 IP– IP+ 6 19 IP– IP+ 7 18 IP– VCC 8 17 A1 SDA 9 16 A0 SCL 10 15 FAULT GND 11 NC 12 14 FREEZE 13 NC Number Name 1 to 7 IP+ Primary current path input terminals Function 8 VCC Device power supply 9 SDA I2C control: interface data signal input/output 10 SCL I2C control: clock signal input/output 11 GND Device ground 12,13 NC 14 FREEZE No internal connection; connect to GND for optimal ESD performance Digital output register freezing control input; pull-up to stop Data register updating 15 ¯F ¯¯A¯¯U¯¯L¯¯T¯ 16 A0 I2C control: address input 0 17 A1 I2C control: address input 1 18 to 24 IP– Primary current path output terminals IP fault flag output; active low Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 3 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor OPERATING CHARACTERISTICS1 Valid throughout an ambient temperature range of –20°C to 125°C, CBYPASS = 0.1 μF, VCC = 3.3 V, unless otherwise noted Characteristics Symbol Test Conditions Min. Typ. Max. Unit 3.0 – 3.6 V Electrical Characteristics Supply Voltage VCC Supply Current ICC No load on SDA and SCL – 9 14 mA Power-On Time tPO TA = 25°C; CBYPASS = open – 64 – μs Internal Bandwidth BWi Small signal –3 dB; TA = 25°C – 2 – kHz Leadframe Resistance RP IP+ to IP– through primary current path – 0.5 – mΩ [GAIN_RANGE] = 10b – 8 – A Current Sensing Range Selection Current Sensing Range2,3 Nominal Resolution3 [GAIN_RANGE] = 11b – 16 – A [GAIN_RANGE] = 00b – 32 – A [GAIN_RANGE] = 01b – 64 – A [GAIN_RANGE] = 10b – 15.66 – mA/LSB [GAIN_RANGE] = 11b – 31.31 – mA/LSB [GAIN_RANGE] = 00b – 62.62 – mA/LSB [GAIN_RANGE] = 01b – 125.24 – mA/LSB ResADC – 9 – bit tADC – 375 × N – μs 1 – 256 data point CSR RES Output Signal Characteristics A-to-D Conversion Resolution A-to-D Conversion Time Average Quantity of Data Points Included in Moving Average Calculation4 N [N7:N0]=[0000 0000] through [1111 1111] represents 1 data point through 256 data points Analog Noise INOISE(rms)(A) TA = 25°C – 15 – mA Analog Noise Density INOISE(den)(A) TA = 25°C – 0.27 – mA/Hz1/2 15 – 496 ADC Code – INOISE(rms)(A) / N1/2 – mA GAIN_RANGE set for optimized CSR, ADC code is within ADCLIN; measured at 2 A; TA = 25°C to 125°C –8 ±5 +8 LSB GAIN_RANGE set for optimized CSR; ADC code is within ADCLIN; measured at 2 A; TA = –20°C to 25°C –15 ±7 +15 LSB A-to-D Linear Range5 Digital Noise ADCLIN INOISE(rms)(D) TA = 25°C Accuracy Performance Offset Error ErrOS Continued on the next page… Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 4 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor OPERATING CHARACTERISTICS1 (continued) Valid throughout an ambient temperature range of –20°C to 125°C, CBYPASS = 0.1 μF, VCC = 3.3 V, unless otherwise noted Characteristics Symbol Test Conditions Min. Typ. Max. Unit GAIN_RANGE set for optimized CSR, ADC code is within ADCLIN ; TA = 25°C to 125°C; measured at 0.94 × CSR –2.5 ±1 +2.5 % GAIN_RANGE set for optimized CSR, ADC code is within ADCLIN ; TA = –20°C to 25°C; measured at 0.94 × CSR –3.5 ±1.5 +3.5 % GAIN_RANGE set for optimized CSR, ADC code is within ADCLIN – ±0.75 – % GAIN_RANGE set for optimized CSR; ADC code is within ADCLIN; Current = 0.94 × CSR; TA = 25°C to 125°C –2.5 ±1 +2.5 % GAIN_RANGE set for optimized CSR; ADC code is within ADCLIN; Current = 0.94 × CSR; TA = –20°C to 25°C –3.5 ±2 +3.5 % Accuracy Performance (continued) Resolution Accuracy Nonlinearity Error Total Error ResACC ErrLIN ErrTOT Lifetime Drift Characteristics Resolution Lifetime Drift ResDRIFT – ±3.0 – % Total Error Lifetime Drift ErrTOT_DRIFT – ±3 – % – A Overcurrent Fault Detection Resolution/Timing Fault Current Maximum Setpoint IFAULT(MAX) FAULT_LEVEL = 0000b – 1.46 × CSR Fault Current Minimum Setpoint IFAULT(MIN) FAULT_LEVEL = 1111b – 0.5 × CSR – A Digital Fault Level Resolution ResFAULT – 4 – bit EFAULT(MIN) GAIN_RANGE set for optimized CSR; measured at FAULT_LEVEL = 0000b –4 ±2.5 +4 % EFAULT(MAX) GAIN_RANGE set for optimized CSR; measured at FAULT_LEVEL = 1111b – ±7 – % 10 – – kΩ Fault Level Error6 ¯¯T¯ Pin Pull up Resistance at ¯F¯¯A¯¯U¯¯L ¯F ¯¯A¯¯U¯¯ ¯¯T ¯ Output Voltage L RPU VFAULT RPU = 10 kΩ, under fault condition – – 0.4 V tFAULT Delay from IP rising above IFAULT until VFAULT < 0.4 V – 100 – μs VFREEZE(IL) – – 0.2 × VCC V FREEZE Pin Input Level (High) VFREEZE(IH) 0.8 × VCC – – V FREEZE Pin Input Impedance RFREEZE(IN) – 10 – kΩ Fault Response Time FREEZE Pin Characteristics FREEZE Pin Input Level (Low) Continued on the next page… Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 5 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor OPERATING CHARACTERISTICS1 (continued) Valid throughout an ambient temperature range of –20°C to 125°C, CBYPASS = 0.1 μF, VCC = 3.3 V, unless otherwise noted Characteristics Address Pin Symbol Test Conditions Min. Typ. Max. Unit Characteristics7 Address Value 0 Voltage VADDR0 A0, A1 pins – 0 0.08 × VCC V Address Value 1 Voltage VADDR1 A0, A1 pins 0.28 × VCC 0.31 × VCC 0.34 × VCC V Address Value 2 Voltage VADDR2 A0, A1 pins 0.53 × VCC 0.56 × VCC 0.59 × VCC V Address Value 3 Voltage VADDR3 A0, A1 pins 0.8 × VCC VCC – V Input Bias Current IA0 A0 pin – 100 – nA IA1 A1 pin – 100 – nA 1All current measurement accuracy specifications listed in this datasheet apply only for the optimized current sensing range. will be most accurate in its optimized gain range. 3The GAIN_RANGE setting of 11b selects the Optimized Nominal Resolution for the 16AU variant, and the GAIN_RANGE setting of 00b selects the Optimized Nominal Resolution for the 32AU variant. 4Programmable by user through the I2C interface. 5The ADC is most linear within ADC LIN, so code readings outside ADCLIN should not be used for precise measurement. 6Percentage of CSR. See table 3 and Definitions of Accuracy Characteristics section. 7Address pin characteristics are ensured by designed but are not factory tested. 2The ACS764 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 6 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 I2C INTERFACE CHARACTERISTICS* Valid at an ambient temperature range of –20°C to 125°C and VCC = 3.3 V; unless otherwise noted Characteristics Symbol Min. Typ. Max. Unit tBUF 1.3 – – μs Hold Time Start Condition thdSTA 0.6 – – μs Setup Time for Repeated Start Condition tsuSTA 0.6 – – μs SCL Low Time tLOW 1.3 – – μs SCL High Time tHIGH 0.6 – – μs ns Bus Free Time Between Stop and Start Test Conditions Data Setup Time tsuDAT 100 – – Data Hold Time thdDAT 0 – 900 ns Setup Time for Stop Condition tsuSTO 0.6 – – μs Logic Input Low Level (SDA, SCL pins) VIL − − 0.3×VCC V Logic Input High Level (SDA, SCL pins) VIH 0.7×VCC − − V Logic Input Current IIN Output Voltage (SDA pin) VOL VIN = 0 V to VCC −1 − 1 μA RPU = 1 kΩ, CB = 100 pF − − 0.2 ×VCC V Logic Input Rise Time (SDA, SCL pins) tr − − 300 ns Logic Input Fall time (SDA, SCL pins) tf − − 300 ns SDA Output Rise Time tr RPU = 1 kΩ, CB = 100 pF − − 300 ns SDA Output Fall Time tf RPU = 1 kΩ, CB = 100 pF − − 300 ns Clock Frequency (SCL pin) fCLK − − 400 kHz SDA and SCL Bus Pull-up Resistor RPU − 1 − kΩ Total Capacitive Load for Each of SDA and SCL Buses CB − − 100 pF *I2C interface characteristics are ensured by designed but are not factory tested. I2C Interface Timing Diagram tsuSTA thdSTA tsuDAT thdDAT tsuSTO tBUF SDA tr tf SCL tLOW tHIGH tr tf Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 7 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Application Information The ACS764 is a fully integrated Hall-effect based current sensor IC with a digital current output and an overcurrent fault output for current monitoring and reporting applications. The digital output can be read from the ACS764 by a master controller through the I2C interface. The I2C interface can also be used to control some features of the ACS764. Sixteen device addresses are available through two input pins (A0, A1), allowing multiple devices to be connected to the same I2C bus in the application. The output data that can be read from the ACS764 through the I2C interface includes the following: • Current amplitude (9 bits) • Unlatched overcurrent fault flag (1 bit) • Latched overcurrent fault flag (1 bit) • Unread new current data flag (1 bit) The control data that can be written to the ACS764 through I2C interface includes the following: • Current range selection (2 bits) • Overcurrent fault level selection (4 bits) • Digital averaging filter data point selection (8 bits) • Latched overcurrent fault flag reset (1 bit) I2 C Interface I2C is a serial interface that uses two bus lines, SCL and SDA, to access the internal device registers. Data is exchanged between a master controller (for example, a microcontroller) and the ACS764 (slave). The clock input to SCL is generated by the master, while the SDA line functions as either an input or an open drain output, depending on the direction of the data transfer. The I2C input thresholds depend on the VCC voltage of the ACS764. Timing Considerations I2C communication is composed of several steps in the following sequence: 1. Start Condition. Defined by a negative edge on the SDA line, while SCL is high. 2. Address Cycle. 7 device (slave) address bits, plus 1 bit to indicate write (0) or read (1), followed by an acknowledge bit. 3. Data Cycles. Reading or writing 8 data bits, followed by an acknowledge bit. This cycle can be repeated for multiple bytes of data transfer. If there are multiple registers in a device (for example, EEPROM), the first data byte could be the register address. See the following sections for further information. 4. Stop Condition. Defined by a positive edge on the SDA line, while SCL is high. Except to indicate a Start or Stop condition, SDA must be stable while the clock is high. SDA can only be changed while SCL is low. It is possible for the Start or Stop condition to occur at any time during a data transfer. The ACS764 always responds by resetting the data transfer sequence. The state of the Read/Write bit is set low to indicate a write cycle and set high to indicate a read cycle. The master monitors for an acknowledge pulse to determine if the slave device is responding to the address byte sent to the ACS764. When the ACS764 decodes the 7-bit address field as a valid address, it responds by pulling SDA low during the ninth clock cycle. During a data write from the master, the ACS764 pulls SDA low during the clock cycle that follows the data byte, in order to indicate that the data has been successfully received. After sending either an address byte or a data byte, the master device must release the SDA line before the ninth clock cycle, in order to allow the handshaking to occur. Writing to ACS764 Registers Through the I2C Interface Bus The master controls the ACS764 by programming it as a slave. To do so, the master transmits data bits to the SDA input of the ACS764 in synchronization with the clocking signal it transmits simultaneously on the SCL input. A complete transmission begins with the master pulling SDA low (Start bit), and completes with the master releasing the SDA line (Stop bit). Between these points, the master transmits a pattern of slave device (ACS764) address bits with a write command (D0 = 0), and then the target register address (within that device), Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 8 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 a low to the master on the SDA line. After writing data to a register the master must provide a Stop bit if writing is completed. If the stop bit is not set, then the next three bytes will be written to the current register address + 1. Writing will continue in this fashion until the Stop bit is received. If the total data byte count (that is, not including the Register Address byte) is not modulo three, then the write operation that would contain less than three bytes is not done. and finally the data for the register. Each register in the ACS764 device is three bytes, or 24 bits, long. The address consists of two bytes, comprising: the ACS764 (device) address (7 bits) and the read/write bit, followed by the address byte of the individual register. The data stream of writing data to an individual register is shown in figure 1. After each byte, the slave ACS764 acknowledges by transmitting ACS764 (Slave) Acknowledge Operation Bit (Write) ACS764 Bus Address Master Start ACS764 (Slave) Acknowledge Register Address SDA A6 A5 A4 A3 A2 A1 A0 RW AK R7 R6 R5 R4 R3 R2 R1 R0 AK SCL 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 ACS764 (Slave) Acknowledge 7 8 ACS764 (Slave) Acknowledge Data Byte 2 ... ... SDA SCL 9 ... ... ACS764 (Slave) Acknowledge Data Byte 1 Master Stop Data Byte 0 D23 D22 D21 D20 D19 D18 D17 D16 AK D15 D14 D13 D12 D11 D10 D9 D8 AK D7 D6 D5 D4 D3 D2 D1 D0 AK 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 MSB Byte 8 9 1 2 3 4 5 6 7 8 9 LSB Byte Figure 1. I2C interface typical data write to an individual register in the ACS764 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 9 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 data from an individual register is shown in figure 2. Reading from ACS764 Registers Through the I2C Interface Bus After each byte of data received, the master acknowledges by transmitting a low to the slave on the SDA line. After receiving three bytes of data from a register, the master must provide a Stop bit if reading is completed. If the Stop bit is not set, then the next three bytes will be read from the initial register address + 1. Reading will continue in this fashion until the Stop bit is received. Please note that the acknowledge bit immediately before the Stop bit should be a non-acknowledge (AK = 1). When the master controller performs a data read from an ACS764 internal register, a so-called combined data transmission format is used. The I2C master provides the Start bit, the ACS764 device (slave) address, the read/write bit set to write (0), and then the initial source register address. The master then issues another Start bit (referred to as restart) followed by the same slave address and the read/write bit set to read (1). The ACS764 then provides three bytes of read data, one byte at a time. The data stream of reading Master Restart ACS764 (Slave) Acknowledge ACS764 (Slave) Acknowledge Operation Bit (Write) ACS764 Bus Address Master Start ACS764 (Slave) Acknowledge Operation Bit (Read) ACS764 Bus Address Register Address SDA A6 A5 A4 A3 A2 A1 A0 RW AK R7 R6 R5 R4 R3 R2 R1 R0 AK A6 A5 A4 A3 A2 A1 A0 RW AK SCL 1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 Master Acknowledge SDA SCL 2 3 4 5 Master Acknowledge Data Byte 2 ... ... 9 6 7 8 9 ... ... Master Non-Acknowledge Data Byte 1 Master Stop Data Byte 0 D23 D22 D21 D20 D19 D18 D17 D16 AK D15 D14 D13 D12 D11 D10 D9 D8 AK D7 D6 D5 D4 D3 D2 D1 D0 NAK 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 MSB Byte 8 9 1 2 3 4 5 6 7 8 9 LSB Byte Figure 2. I2C interface typical data read from an individual register in the ACS764 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 10 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 I2C Device (Slave) Address Coding The four LSBs of the device (slave) address (A3, A2, A1, and A0) can be set by applying different voltages to pins A0 and A1 as show in figure 3 and defined in table 1. Note: Different values for the three MSBs of the address (A6, A5, and A4) are available for factory programming if a conflict with other units occurs in the application design. ACS764 Bus Address Byte Definitions Address Bit A6 A5 1 1 A4 A3 A2 A1 A0 0/1 0/1 Binary Device Address Value 0 0/1 0/1 Table 1. I2C Device Address Coding (Refer to figure 3) Device Address # Voltage on A1 Pin, VA1 Voltage on A0 Pin, VA0 Decimal Binary (A3, A2, A1,A0) 0V 0V 0 0000 0V 0.31 × VCC 1 0001 0V 0.56 × VCC 2 0010 0V VCC 3 0011 0.31 × VCC 0V 4 0100 0.31 × VCC 0.31 × VCC 5 0101 0.31 × VCC 0.56 × VCC 6 0110 0.31 × VCC VCC 7 0111 0.56 × VCC 0V 8 1000 0.56 × VCC 0.31 × VCC 9 1001 0.56 × VCC 0.56 × VCC 10 1010 0.56 × VCC VCC 11 1011 VCC 0V 12 1100 VCC 0.31 × VCC 13 1101 VCC 0.56 × VCC 14 1110 VCC VCC 15 1111 VCC VCC VA0, VA1 ACS764 A0, A1 43 kΩ Figure 3. External equivalent circuit for I2C device address selection 0.56 × VCC 24 kΩ I2C Interface 0.31 × VCC 30 kΩ 0V Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 11 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Table 2. User-Accessible Volatile Memory Registers Data Register I2C Register Address Bits Parameter Name 0x00 23:12 Reserved 0x00 11 NON-LATCHED_FAULT_STATUS 0x00 10 LATCHED_FAULT_STATUS 0x00 9 SYNC 0x00 8:0 CURRENT Description Read as all 0s Non-Latched Fault bit (Read only) Latched Fault bit; resets with 1 written to this bit (Read/Write) Sync (new data) bit; resets when this register is read (Read only) Current Sensor output value (digital filter output) (Read only) Control Registers I2C Register Address Bits Parameter Name 0x02 7:0 AVG_POINTS Number of averaging points (Read/Write) 0x04 1:0 GAIN_RANGE Current sensing range selection (Read/Write) 0x06 3:0 FAULT_LEVEL Fault threshold selection (Read/Write) Description Default 0 0 (32AU version) 3 (16AU version) 0 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 12 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 User-Accessible Register Bit Descriptions Volatile Register Bits (Address: 0x00) X X X X X X X X X X X X 0/1 0/1 0/1 D8 D7 D6 D5 D4 D3 D2 D1 D0 Reserved CURRENT NON-LATCHED_FAULT_STATUS LATCHED_FAULT_STATUS SYNC Volatile Register Bits (Address: 0x02) X X X X X X X X X X X X X X X X N7 N6 N5 N4 N3 N2 N1 N0 Reserved AVG_POINTS Volatile Register Bits (Address: 0x04) X X X X X X X X X X X X X X X X X X X X X X G1 G0 Reserved GAIN_RANGE Volatile Register Bits (Address: 0x06) X X X X X X X X X X X X X X X X X X X X F3 F2 F1 F0 Reserved FAULT_LEVEL Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 13 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Working with Internal Device Registers Through I2C Control Registers On power-up the control registers will be loaded to their default values from the EEPROM. The settings can be changed after powering on the device by overwriting the control registers through the I2C interface. However, the control registers will revert to their previous levels if the sensor IC is power cycled. Contact your local sales representative if you need the default control register values to be factory-programmed differently. Data Registers The volatile register at 0x00 holds all the output data of the device. It includes nine bits of current measurement data and three flag bits: one bit for current output update (SYNC), one bit for latched overcurrent fault (LATCHED_FAULT_STATUS), and one bit for non-latched overcurrent fault (NON-LATCHED_ FAULT_STATUS), in that order. After the current measurement data has been updated, SYNC is set. It will be reset when the data is read by a master controller through the I2C interface. When an overcurrent fault condition is detected, both the LATCHED_FAULT_STATUS and the NON-LATCHED_ FAULT_STATUS bits will be set. The NON-LATCHED_ FAULT_STATUS bit will be reset after the overcurrent condition is removed. However, the LATCHED_FAULT_STATUS bit will remain set until a 24-bit word in the format: XXXX XXXX XXXX X1XX XXXX XXXX is written to the register. Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 14 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Setting the Overcurrent Fault Threshold The Overcurrent Fault threshold, IFAULT , is determined by setting the four FAULT_LEVEL bits. The combined settings determine the threshold as a percentage of current sensing range, CSR. The ¯F¯A ¯¯U¯¯L¯¯T¯ pin will be pulled low when the current is above the ¯ pin will be released programmed I_FAULT level. The ¯F¯A¯¯U¯¯L¯¯T when the current drops below the programmed I_FAULT level. The digital NON-LATCHED FAULT STATUS bit will be 1 when the current is above I_FAULT and 0 when the current is below I_FAULT. The LATCHED FAULT STATUS bit will be 1 when the current is above I_FAULT and will only return to being 0 when the current is below I_FAULT and the bit is reset by writing a 1 to it. Table 3. I2C Control: Settings for Overcurrrent Fault Threshold FAULT_LEVEL Bits IFAULT F3 F2 F1 F0 Level Setting ( %CSR ) 0 0 0 0 0 50 0 0 0 1 1 56 0 0 1 0 2 63 0 0 1 1 3 69 0 1 0 0 4 76 0 1 0 1 5 82 0 1 1 0 6 88 0 1 1 1 7 95 1 0 0 0 8 101 1 0 0 1 9 108 1 0 1 0 10 114 1 0 1 1 11 120 1 1 0 0 12 127 1 1 0 1 13 133 1 1 1 0 14 140 1 1 1 1 15 146 Example: If the required overcurrent fault threshold is 88% of the CSR , then the required FAULT_LEVEL values are: 0110 (Level 6). Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 15 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 Characteristic Performance Data Data taken using the ACS764-32AU Accuracy Data Offset Error versus Ambient Temperature Resolution versus Ambient Temperature 20.00 15.00 Sens (mV/A) ErrOS (LSB) 10.00 5.00 0 -5.00 -10.00 -15.00 -20.00 -40 -20 0 20 40 60 80 100 120 65.50 65.00 64.50 64.00 63.50 63.00 62.50 62.00 61.50 61.00 60.50 60.00 140 -40 -20 0 20 40 TA (°C) 100 120 140 Fault Minimum Error versus Ambient Temperature 4.00 5.00 3.00 4.00 3.00 EFAULT(MIN) (%) 2.00 ErrTOT (%) 80 TA (°C) Total Error versus Ambient Temperature 1.00 0 -1.00 -2.00 2.00 1.00 0 -1.00 -2.00 -3.00 -3.00 -4.00 -4.00 -40 -20 0 20 40 60 80 100 120 -5.00 -40 140 -20 0 20 40 Fault Maximum Error versus Ambient Temperature 8.00 80 100 120 140 Total Error versus Current TA = 25°C 8.00 6.00 6.00 4.00 ErrTOT (%) 2.00 0 -2.00 -4.00 -6.00 4.00 2.00 0 -2.00 -8.00 -4.00 -10.00 -12.00 -40 60 TA (°C) TA (°C) EFAULT(MAX) (%) 60 -6.00 -20 0 20 40 60 80 100 120 140 0 2 4 6 8 10 TA (°C) 12 14 16 18 20 22 24 26 28 30 32 Current (A) +3 sigma Maximum Limit Mean -3 sigma Minimum Limit Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 16 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 Characteristic Performance Data Data taken using the ACS764-16AU Accuracy Data Offset Error versus Ambient Temperature Resolution versus Ambient Temperature 20.00 33.00 15.00 32.50 Sens (mV/A) ErrOS (LSB) 10.00 5.00 0 -5.00 32.00 31.50 31.00 -10.00 30.50 -15.00 -20.00 -40 30.00 -20 0 20 40 60 80 100 120 140 -20 0 20 40 80 100 120 140 Total Error versus Ambient Temperature Fault Minimum Error versus Ambient Temperature 4.00 5.00 3.00 4.00 3.00 EFAULT(MIN) (%) 1.00 0 -1.00 -2.00 2.00 1.00 0 -1.00 -2.00 -3.00 -3.00 -4.00 -4.00 -40 -20 0 20 40 60 80 100 120 -5.00 -40 140 -20 0 20 40 TA (°C) 6.00 8.00 5.00 6.00 4.00 4.00 3.00 ErrTOT (%) 10.00 2.00 0 -2.00 80 100 120 140 14 16 Total Error versus Current TA = 25°C 2.00 1.00 0 -4.00 -1.00 -6.00 -2.00 -8.00 -3.00 -10.00 -40 60 TA (°C) Fault Maximum Error versus Ambient Temperature EFAULT(MAX) (%) 60 TA (°C) 2.00 ErrTOT (%) -40 TA (°C) -4.00 -20 0 20 40 60 80 100 120 0 140 2 4 TA (°C) 6 8 10 12 Current (A) +3 sigma Maximum Limit Mean -3 sigma Minimum Limit Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 17 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 Definitions of Accuracy Characteristics A-to-D Linear Range (ADCLIN) The range of the ADC over which the ADC code is proportional to the current being sensed. One should consider the ADC saturated outside this range. See figure 4. Offset Error (ErrOS) The offset of the ADC code versus the measured current from the ideal of zero. See figure 4. This parameter is measured at 2 A, as the ADC is below ADCLIN at zero current. The offset error is calculated as: 1 ErrOS = ADCCODE at 2 A – 2000 (mA) × RES Resolution Accuracy (ResACC) The resolution of the sensor is given in mA/LSB, which is the inverse of the slope of the ADC code versus the measured current (see figure 4). Multiplying the ADC code by the resolution yields the measured current. The Resolution Accuracy (ResACC) is how 511 Ignore (consider saturated) ADC Code (LSB) ADCLIN(max) { Ideal ADC Behavior Offset Error 0 Nonlinearity Error (ErrLIN) The Nonlinearity Error is a measure of how linear the ADC code versus measured current curve is. The nonlinearity is calculated as: 0.5 ADCCODE (0.94 × CSR) – ErrOS ErrLIN = 1– × 100 (%) 0.94 ADCCODE (0.5 × CSR) – ErrOS Total Error (ErrTOT) The percentage difference between the current measurement from the sensor IC and the actual current being measured (IP), relative to the actual current. This is equivalent to the percentage difference between the ideal ADC code and the actual ADC code, relative to the ideal ADC code: ADCIDEAL(IP) – ADC(IP) × 100 (%) ADCIDEAL(IP) 2 CSR Measured Current (IP) (A) Fault Level Error (EFAULT(MIN), EFAULT(MAX)) The Fault Level Error is a measure of the accuracy of the overcurrent fault function. EFAULT(MIN) is EFAULT measured at FAULT_LEVEL = 0000b, and EFAULT(MAX) is EFAULT measured at FAULT_LEVEL = 1111b. The Fault Level Error is calculated as: EFAULT(FAULT_LEVEL) = Ignore (consider saturated) Figure 4. A-to-D Linear Range Measured Resolution – RES × 100 (%) RES The Total Error incorporates all sources of error and is a function of the measured current ( IP ). At relatively high currents, ErrTOT will be mostly due to the Resolution Accuracy, and at relatively low currents, ErrTOT will be mostly due to the Offset Error. Actual ADC Behavior { ResACC = ErrTOT(IP) = 1/Resolu on ADCLIN(min) close the actual resolution is to the Nominal Resolution (RES). The Resolution Accuracy is calculated as: Fault Trip Current – IFAULT_Percent CSR × 100 (%) where IFAULT_Percent is the ideal percentage of CSR at which the overcurrent fault should trip, based on the FAULT_LEVEL settings as given in table 3. For example, if FAULT_LEVEL is set to 0000b, the ideal trip point is at 50% of CSR. An EFAULT(MIN) specification of ±4% means the actual trip point ia between 46% and 54% of CSR. Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 18 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Dynamic Response Characteristics Power-On Time (tPO): When the supply is ramped to its operating voltage, the device requires a finite time to power its internal components before responding to a magnetic field due to current flow through the sensor. Power-On Time, tPO , is defined as the time it takes from when the supply voltage (VCC) reaches its minimum specified voltage to when the value from the ADC is valid, as well as the fault bits and fault output. Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 19 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 Chopper Stabilization Technique When using Hall-effect technology, a limiting factor for switchpoint accuracy is the small signal voltage developed across the Hall element. This voltage is disproportionally small relative to the offset that can be produced at the output of the Hall sensor IC. This makes it difficult to process the signal while maintaining an accurate, reliable output over the specified operating temperature and voltage ranges. Chopper stabilization is a unique approach used to minimize Hall offset on the chip. Allegro employs a patented technique to remove key sources of the output drift induced by thermal and mechanical stresses. This offset reduction technique is based on a signal modulation-demodulation process. The undesired offset signal is separated from the magnetic field-induced signal in the frequency domain, through modulation. The subsequent demodulation acts as a modulation process for the offset, causing the magnetic field-induced signal to recover its original spectrum at baseband, while the DC offset becomes a high-frequency signal. The magnetic-sourced signal then can pass through a low-pass filter, while the modulated DC offset is suppressed. In addition to the removal of the thermal and stress related offset, this novel technique also reduces the amount of thermal noise in the Hall sensor IC while completely removing the modulated residue resulting from the chopper operation. The chopper stabilization technique uses a high-frequency sampling clock. For demodulation process, a sample-and-hold technique is used. This high-frequency operation allows a greater sampling rate, which results in higher accuracy and faster signal-processing capability. This approach desensitizes the chip to the effects of thermal and mechanical stresses, and produces devices that have extremely stable quiescent Hall output voltages and precise recoverability after temperature cycling. This technique is made possible through the use of a BiCMOS process, which allows the use of low-offset, low-noise amplifiers in combination with high-density logic integration and sample-and-hold circuits. Regulator Clock/Logic Hall Element Amp Anti-Aliasing LP Filter Tuned Filter Concept of Chopper Stabilization Technique Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 20 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor ACS764 Package LF, 24-Pin QSOP 8º 0º 8.66 ±0.10 24 0.25 0.15 3.91 ±0.10 2.30 5.00 5.99 ±0.20 A 1.27 0.41 1 1.04 REF 2 0.25 BSC Branded Face 24X 1.75 MAX 0.20 C 0.30 0.20 0.635 BSC SEATING PLANE C 0.40 0.635 B SEATING PLANE GAUGE PLANE 0.25 MAX PCB Layout Reference View NNNNNNNNNNNNN TLF-AAA For Reference Only, not for tooling use (reference JEDEC MO-137 AE) Dimensions in millimeters Dimensions exclusive of mold flash, gate burrs, and dambar protrusions Exact case and lead configuration at supplier discretion within limits shown LLLLLLLLLLL A Terminal #1 mark area B Reference pad layout (reference IPC7351 SOP63P600X175-24M) All pads a minimum of 0.20 mm from all adjacent pads; adjust as necessary to meet application process requirements and PCB layout tolerances C Branding scale and appearance at supplier discretion C Standard Branding Reference View N = Device part number T = Temperature code LF = (Literal) Package type A = Amperage Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 21 ACS764 Fully Integrated, Hall-Effect Based Current Sensor IC with I2C Digital Output and Low-Resistance Current Conductor Copyright ©2010-2013, Allegro MicroSystems, LLC I2C™ is a trademark of Philips Semiconductors. Allegro MicroSystems, LLC reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the performance, reliability, or manufacturability of its products. Before placing an order, the user is cautioned to verify that the information being relied upon is current. Allegro’s products are not to be used in any devices or systems, including but not limited to life support devices or systems, in which a failure of Allegro’s product can reasonably be expected to cause bodily harm. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, LLC assumes no responsibility for its use; nor for any infringement of patents or other rights of third parties which may result from its use. For the latest version of this document, visit our website: www.allegromicro.com Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com 22
ASEK764XLF-16AU-T-KIT-DK 价格&库存

很抱歉,暂时无法提供与“ASEK764XLF-16AU-T-KIT-DK”相匹配的价格&库存,您可以联系我们找货

免费人工找货