0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1397-U7FN-HA2-DS050-PE

1397-U7FN-HA2-DS050-PE

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    1397-U7FN-HA2-DS050-PE - Digital DC Drive - Allen-Bradley

  • 数据手册
  • 价格&库存
1397-U7FN-HA2-DS050-PE 数据手册
1397 Digital DC Drive Available in either regenerative or non-regenerative configurations, the 1397 family of digital DC drives employs advanced microprocessor technology to help deliver performance, flexibility and communications options in a complete, economical drive package. To help achieve accurate setup, precise control and flexible operation, all 1397 DC drives are digitally programmable. Each drive may be programmed locally from a front mounted control panel, or from an external Allen-Bradley PLC® or SLC®. Contents Description 1397 Product Selection Factory Installed Options User Installed Options Page(s) 2 4 5 Conformity to Standards The 1397 conforms to the following: Conforms to: UL Listed CSA Certified (C-UL) CE Approved Standard Product ✔ ✔ ✔ Allen-Bradley 1 1397 Digital DC Drive 1397 Product Selection The 1397 product program includes standard 1397 DC drives rated from (1.1-448 kW) 1.5-600Hp, offered in both regenerative and nonregenerative configurations. All drives are supplied chassis mounted – IP 00 (open) – for user installation. There is a limited offering of factory mounted options along with a larger offering of option kits for user installation. All standard products in this program are predefined and not generally subject to modification. For special requirements consult Allen-Bradley. 230V AC Input Product Selection 1397 Bulletin Number - A001N ➊ - HA2 ➋ Rating Type (must be specified) Control Interface (must be specified) DS050 AC Line Disconnect (optional) - PE Pulse Encoder Interface (optional) Nominal Drive Rating 230V AC Drives — IP 00 (Open) — No Enclosure kW (Hp) ➌ 1.2 (1.5) 1.5 (2) 2.2 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) 37 (50) 45 (60) 56 (75) 75 (100) 93 (125) 112 (150) Code A001__➊ A002__➊ A003__➊ A005__➊ A007__➊ A010__➊ A015__➊ A020__➊ A025__➊ A030__➊ A040__➊ A050__➊ A060__➊ A075__➊ A100__ ➊ A125__➊ A150__ ➊ 230V AC Rated➍ 240VDC Rated➍ Line Amps Armature Amps 10 11 13 19 26 33 48 63 80 94 125 154 186 226 307 370 443 7 9 12 20 29 38 55 73 93 110 146 180 218 265 360 434 521 150VDC Rated➎ Field Amps 10 10 10 10 10 10 10 15 15 15 15 15 15 15 15 15 15 ➊ Either an “N” (non-regenerative) or an “R” (regenerative) drive must be specified. ➋ At least one of either a Human Interface Module (HIM) or Option 1203-GD2 using DriveTools32™ will be required to program the drive. Chosen option(s) may be ordered factory installed (if available) or as user installed kits. ➌ kW ratings are based on rated input voltage. ➍ Consult factory for alternate voltages. ➎ For special field voltage requirements refer to the Enhanced Field Supply Option. 2 Allen-Bradley 1397 Digital DC Drive 380/415V AC Product Selection 1397 Bulletin Number - U55FN ➊ - HA2 ➋ Rating Type (must be specified) Control Interface (must be specified) DS050 AC Line Disconnect (optional) - PE Pulse Encoder Interface (optional) 380/415V AC Drives — IP 00 (Open) — No Enclosure 380V AC Input 415V AC Input kW (Hp) 1.8 (2.4) 9 (12) 17.9 (24) 35.8 (48) 89.5 (120) kW (Hp) 2.1(2.8) 10.3(13.8) 20.8(27.6) 41.2(55.2) 102.9(138) Code U7F__➊ U29F__➊ U55F__➊ U110F__➊ U265F__➊ 380/415V AC 400/460V DC Rated 250/270V DC Rated Rated Line Amps Armature Amps Field Amps 10 26 48 94 226 7 29 55 110 265 10 10 10 15 20 460V AC Product Selection 1397 Bulletin Number - B003N ➊ - HA2 ➋ Rating Type (must be specified) Control Interface (must be specified) DS050 AC Line Disconnect (optional) - PE Pulse Encoder Interface (optional) Nominal Drive Rating 460V AC Drives — IP 00 (Open) — No Enclosure kW (Hp) ➌ 2.2 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) 37 (50) 45 (60) 56 (75) 75 (100) 93 (125) 112 (150) 149 (200) 187 (250) 224 (300) 298 (400) 373 (500) 448 (600) Code B003__➊ B005__➊ B007__➊ B010__➊ B015__➊ B020__➊ B025__➊ B030__➊ B040__➊ B050__➊ B060__➊ B075__➊ B100__➊ B125__➊ B150__➊ B200__➊ B250__➊ B300__➊ B400__➊➏ B500__➊➏ B600__➊➏ 460V AC Rated ➍ 500VDC Rated ➍ Line Amps Armature Amps 10 12 15 18 24 31 39 45 63 74 86 110 143 177 213 281 351 421 567 680 816 6 10 14 19 27 35 45 52 73 86 100 129 167 207 250 330 412 495 667 800 960 300VDC Rated ➎ Field Amps 10 10 10 10 10 10 10 10 15 15 15 15 15 15 15 15 15 15 15 15 15 ➊ Either an “N” (non-regenerative) or an “R” (regenerative) drive must be specified. ➋ At least one of either a Human Interface Module (HIM) or Option 1203-GD2 using DriveTools32™ will be required to program the drive. Chosen option(s) may be ordered factory installed (if available) or as user installed kits. ➌ kW ratings are based on rated input voltage. ➍ Consult factory for alternate voltages. ➎ For special field voltage requirements refer to the Enhanced Field Supply Option. ➏ Inverting fault protection must be separately supplied external to drive on 400-600 Hp negative. See user installed option 1397-IFB600. Allen-Bradley 3 1397 Digital DC Drive Factory Installed Options Control Options ➊ Description 460V Rating ➋ kW (Hp) (3-50) 2.3-37 (60) 45 (75-125) 56-93 (150) 112 (200) 149 (250-300) 187-224 (400-500) 298-373 (600) 448 Blower Motor Starter - Current Rated Blower Motor Amp Current Rating 0.4-0.63 0.63-1.0 1.0-1.4 1.4-1.8 1.7-2.4 2.2-3.1 2.8-4.0 3.5-5.0 4.5-6.5 6.0-8.5 7.5-11.0 Pulse Encoder Interface AC Tachometer Interface Fixed Field Supply Enhanced Field Supply - Current Rated - Provides field preweakening for gear-in. - Provides 2 240V DC field on 230V AC rated drives for textile and MG set replacement applications. - Provides a means to match many different field voltages without requiring a transformer DC Amp Current Rating 10 20 AC Line Disconnect 230V Rating ➋ kW (Hp) (1.5-25) 1.2-18.5 (30) 22 (40-60) 30-45 (75) 56 (100) 75 (125-150) 92-112 Used With . . . All Drives Option Code -DS050 -DS060 -DS125 -DS150 -DS200 -DS300 -DS500 -DS600 All Drives -MB006 -MB010 -MB014 -MB018 -MB024 -MB031 -MB040 -MB050 -MB065 -MB085 -MB110 All Drives -PE All Non-Regen Drives -AC All Drives ➌➍ All Drives ➌ All Drives Regulated Field Supply - Current Rated Provides field weakening and field current regulation DC Amp Current Rating 4 10 15 I/O Expansions Card All Drives Provides additional I/O structure (5) Digital Outputs (2) Digital Outputs (2) Analog Inputs (2) Analog Outputs (1) Frequency Input Frequency Output -FS3010 -FS3020 ➌ -FS2004 -FS2010 -FS2015 -L11 ➊ All options are chassis mounted unless noted. For a more functionally complete description of each option, refer to publication 1397-BR001. ➋ kW ratings are based on rated input voltage. ➌ Fixed Field Supply is provided with: 230V AC drives rated 56 kW (75 Hp) and below 380V AC drives rated 35.8 kW (48 Hp) and below 415V AC drives rated 41.2 kW (55.2 Hp) and below 460V AC drives rated 112 kW (150 Hp) and below. Regulated Field Supply is provided with: 230V AC drives rated 75 kW (100 Hp) and above 380V AC drives rated 89.5 kW (120 Hp) 415V AC drives rated 102.9 kW (138 Hp) 460V AC drives rated 149 kW (200 Hp) and above. ➍ Fixed Field Supply does not have field economy. Check motor requirements for applicability. 4 Allen-Bradley 1397 Digital DC Drive HIM Options Description IP 20 (NEMA/UL Type 1) HIM Blank - No Functionality Programmer Only Programmer/Controller w/Analog Pot Programmer/Controller w/Digital Pot Used With . . Option Code -HAB -HAP -HA1 -HA2 All Drives User Installed Options Inverting Fault Breaker Kit Description Used With. . . Catalog Number 1397-IFB600 Provides inverting fault protection for 400-600 Hp regen- 400-600 Hp erative drives. Trip setting adjustable for 400, 500, or 600 regenerative drives. Hp Drives. Mounts separately from the Drive Chassis. 240V DC Dynamic Brakes, IP00 (No Enclosure) ➊ Drive Output kW (Hp) ➋ 1.2 (1.5) 1.5 2) 2.2 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) 37-45 (50-60) 56 (75) 75 (100) 93 (125) 112 (150) Used With. . . All 230VAC Input Drives Catalog Number 1397-DB-A001L 1397-DB-A002L 1397-DB-A003L 1397-DB-A005L 1397-DB-A007L 1397-DB-A010L 1397-DB-A015L 1397-DB-A020L 1397-DB-A025L 1397-DB-A030L 1397-DB-A040L 1397-DB-A060L 1397-DB-A075L 1397-DB-A100L 1397-DB-A125L 1397-DB-A150L 500V DC Dynamic Brakes, IP00 (No Enclosure) ➊ Drive Output kW (Hp) ➋ 2.2 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15-18.5 (20-25) 22 (30) 30 (40) 37-45 (50-60) 56 (75) 75-93 (100-125) 112 (150) 149 (200) 187 (250) 224 (300) 298 (400) 373 (500) 448 (600) Used With. . . All 460V AC Input Drives Catalog Number 1397-DB-B003L 1397-DB-B005L 1397-DB-B007L 1397-DB-B010L 1397-DB-B015L 1397-DB-B025L 1397-DB-B030L 1397-DB-B040L 1397-DB-B060L 1397-DB-B075L 1397-DB-B125L 1397-DB-B150L 1397-DB-B200L 1397-DB-B250L 1397-DB-B300L 1397-DB-B400L 1397-DB-B500L 1397-DB-B600L ➊ Dynamic brake hardware (DC loop contactor, control transformer & grids) mounts separately from the drive chassis. For a more functionally complete description of each option refer to publication 1397-BR001. Dynamic Brake Kits 1397-DB-B400L, -B500L, and -B600L use the Drive contactor. ➋ kW ratings are based on rated input voltage. Allen-Bradley 5 1397 Digital DC Drive Line Reactors, IP00 (Open Style) – 230V, 60Hz Drive Catalog Number A001 A002 A003 A005 A007 A010 A015 A020 A025 A030 A040 A050 A060 A075 A100 A125 A150 Input or Output Line Reactor Drive Output kW 1.2 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 56 75 93 112 Hp 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 3% Impedance Catalog Number 1321-3R8-A 1321-3R8-A 1321-3R12-A 1321-3R18-A 1321-3R25-A 1321-3R35-A 1321-3R45-A 1321-3R55-A 1321-3R80-A 1321-3R100-A 1321-3R130-A 1321-3R160-A 1321-3R160-A 1321-3R200-A 1321-3RB250-A 1321-3RB320-A 1321-3RB400-A 5% Impedance Catalog Number 1321-3R8-B 1321-3R8-B 1321-3R12-B 1321-3R18-B 1321-3R25-B 1321-3R35-B 1321-3R45-B 1321-3R55-B 1321-3R80-B 1321-3R100-B 1321-3R130-B 1321-3R160-B 1321-3R160-B 1321-3R200-B 1321-3RB250-B 1321-3RB320-B 1321-3RB400-B Line Reactors, IP00 (Open Style) – 460V, 60Hz Drive Catalog Number B003 B005 B007 B010 B015 B020 B025 B030 B040 B050 B060 B070 B100 B125 B150 B200 B250 B300 B400 B500 B600 Input or Output Line Reactor Drive Output kW 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 56 75 93 112 149 187 224 298 373 448 Hp 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 500 600 3% Impedance Catalog Number 1321-3R8-C 1321-3R8-B 1321-3R12-B 1321-3R18-B 1321-3R25-B 1321-3R35-B 1321-3R35-B 1321-3R45-B 1321-3R55-B 1321-3R80-B 1321-3R80-B 1321-3R100-B 1321-3R130-B 1321-3R160-B 1321-3R200-B 1321-3RB250-B 1321-3RB320-B 1321-3RB400-B 1321-3R500-B 1321-3R600-B 1321-3R750-B 5% Impedance Catalog Number 1321-3R8-D 1321-3R8-C 1321-3R12-C 1321-3R18-C 1321-3R25-C 1321-3R35-C 1321-3R45-C 1321-3R55-C 1321-3R80-C 1321-3R80-C 1321-3R100-C 1321-3R130-C 1321-3R160-C 1321-3R160-C 1321-3R200-C 1321-3RB250-C 1321-3RB320-C 1321-3RB400-C 1321-3R500-C 1321-3R600-C 1321-3R750-C 6 Allen-Bradley 1397 Digital DC Drive Line Reactors, IP00 (Open Style) – 380V, 50Hz Drive Catalog Number U7F U29F U55F U110F U265F Input or Output Line Reactor Drive Output kW 1.8 9 17.9 35.8 89.5 Hp 2.4 12 24 48 120 3% Impedance Catalog Number 1321-3R8-C 1321-3R25-B 1321-3R45-B 1321-3R80-A 1321-3R200-B 5% Impedance Catalog Number 1321-3R8-D 1321-3R25-C 1321-3R45-C 1321-3R80-B 1321-3R200-C Line Reactors, IP00 (Open Style) – 415V, 50Hz Drive Catalog Number U7F U29F U55F U110F U265F Input or Output Line Reactor Drive Output kW 2.1 10.3 20.8 41.2 102.9 Hp 2.8 13.8 27.6 55.2 138 3% Impedance Catalog Number 1321-3R8-C 1321-3R25-B 1321-3R45-B 1321-3R80-A 1321-3R200-B 5% Impedance Catalog Number 1321-3R8-D 1321-3R25-C 1321-3R45-C 1321-3R80-B 1321-3R200-C Allen-Bradley 7 1397 Digital DC Drive Isolation Transformers, Three-Phase – IP32, NEMA/UL Type 3R 1397 Drive Output ➋ kW (Hp) Transformer Output Rating Primary Voltage Secondary Voltage kVA Volts 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230 460 230V AC Catalog Number 1321-3TW005-AA 1321-3TW005-BA 1321-3TW007-AA 1321-3TW007-BA 1321-3TW011-AA 1321-3TW011-BA 1321-3TW014-AA 1321-3TW014-BA 1321-3TW020-AA 1321-3TW020-BA 1321-3TW027-AA 1321-3TW027-BA 1321-3TW034-AA 1321-3TW034-BA 1321-3TW040-AA 1321-3TW040-BA 1321-3TW051-AA 1321-3TW051-BA 1321-3TH063-AA 1321-3TH063-BA 1321-3TH075-AA 1321-3TH075-AB 1321-3TH093-AA 1321-3TH093-BA 1321-3TH118-AA 1321-3TH118-BA 1321-3TH145-AA 1321-3TH145-BA 1321-3TH175-AA 1321-3TH175-BA 1321-3TH220-AA 1321-3TH220-BA 1321-3TH275-AA 1321-3TH275-BA 1321-3TH330-AA 1321-3TH330-BA — — — — — — 460V AC Catalog Number — — 1321-3TW007-AB 1321-3TW007-BB 1321-3TW011-AB 1321-3TW011-BB 1321-3TW014-AB 1321-3TW014-BB 1321-3TW020-AB 1321-3TW020-BB 1321-3TW027-AB 1321-3TW027-BB 1321-3TW034-AB 1321-3TW034-BB 1321-3TW040-AB 1321-3TW040-BB 1321-3TW051-AB 1321-3TW051-BB 1321-3TH063-AB 1321-3TH063-BB 1321-3TH075-AB 1321-3TH075-BB 1321-3TH093-AB 1321-3TH093-BB 1321-3TH118-AB 1321-3TH118-BB 1321-3TH145-AB 1321-3TH145-BB 1321-3TH175-AB 1321-3TH175-BB 1321-3TH220-AB 1321-3TH220-BB 1321-3TH275-AB 1321-3TH275-BB 1321-3TH330-AB 1321-3TH330-BB 1321-3TH440-AB 1321-3TH440-BB 1321-3TH550-AB 1321-3TH550-BB 1321-3TH660-AB 1321-3TH660-BB 1.2-2.2 (1.5-3) 5 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) 37 (50) 45 (60) 56 (75) 75 (100) 93 (125) 112 (150) 149 (200) 187 (250) 224 (300) 298 (400) 373 (500) 448 (600) 7.5 11 14 20 27 34 40 51 63 75 93 118 145 175 220 275 330 440 550 660 ➊ Note the discount schedule difference between Bulletin 1321 and 1397 products. ➋ kW ratings are based on rated input voltage. 8 Allen-Bradley 1397 Digital DC Drive Communication Option Kits ➍ Option Cable 1202-C03/C10/C30/C90 Description to PLC Used with . . . All Drive Ratings Catalog Number (Loose Kit) to Drive RIO Comm Status Remote Mounted (DIN Rail) – 115V AC Requires 115V AC power supply Single Point Remote I/O RS232/422/485, DF1 and DH485 Protocol Remote Mounted (DIN Rail) – 24V DC Requires 24V DC power supply Single Point Remote I/O RS232/422/485, DF1 and DH485 Protocol DeviceNet™ Enhanced DeviceNet™ ControlNet™ to SCANport Adapter ➊➋ Remote Mounted (DIN Rail) Requires 24VDC power supply 1203-GD1 ➊ 1203-GD2 ➊ All Drive Ratings 1203-GK1 ➊ 1203-GK2 ➊ 1203-GK5 ➊ 1203-GU6 ➊➋ All Drive Ratings 1203-CN1 ➊➋ Input Voltage DIN Rail 120/240V AC Input Communication Module GD1/GD2 – Typical Configuration SLC EtherNet/IP to SCANport Adapter ➊➋ Remote Mounted (DIN Rail), 24V DC Requires 24VDC power supply AC to DC Power Receptacle ESC SEL All Drive Ratings 1203-EN1 ➊➋ 20-XCOMM-AC-PS1 All Drive Ratings 1203-SFC JOG Serial Flash Cable Connects CN1, GU6 and SSS to a computer RS-232 port for adapter programming and for DriveTools32 & DriveExplorer™ serial interface. SLC™ Communication Module (SLC 500 to SCANport Module) Provides a connection for up to 3 drive products. Smart Self-powered Serial Converter Includes 1203-SFC and 1202-C10 Cables Serial Null Modem Adapter All Drive Ratings 1203-SM1 ➊ SM1 – Typical Configuration All Drive Ratings 1203-SSS 1203-SNM 1203-USB ESC SEL ESC SEL JOG JOG All Drives Universal Serial Bus™ (USB) Converter Includes 2m USB, 20-HIM-H10 & 22-HIM-H10 Cables Communication Option Cable Kit 0.33 Meters (1.1 Feet) 1 Meter (3.3 Feet) 3 Meter (9.8 Feet) 9 Meter (29.5 Feet) All Communication Options Listed 1202-C03 1202-C10 1202-C30 1202-C90 1203-SG2 1203-SG4 1203-S03 CN1 – Typical Configuration SCANport Expander Module One to Two One to Four One to Two Port Splitter Cable All Drive Ratings ➊ Requires a Communication Option Cable (1202-C03/C10/C30/C90) to be functional. These units are not acceptable for NEMA/UL Type 4 door mounting or UL Type 4X outdoor duty. ➋ Adapter is programmed/configured via RS-232 using the 1203-SFC cable, (purchased separately) and using a compatible network specific software tool. ➌ Discount Schedule C2. ➍ Options mount separately from the drive chassis. For a more functionally complete description of each option, refer to publication 1397-BR001. Allen-Bradley 9 1397 Digital DC Drive Human Interface Module (HIM) Options Description HIM Used With. . . All Drives Catalog Number HIM Cradle Option Cable 1202-H03/H10/H30/H90 Communication Port HIM Option Cable 1202-C03/C10/C30/C90 Human Interface Modules IP 20 (NEMA/UL Type 1) Blank — No Functionality Programmer Only Programmer/Controller w/Analog Pot Programmer/Controller w/Digital Pot Human Interface Modules IP 66 (NEMA/UL Type 12/UL Type 4X Indoor) Programmer Only Programmer/Controller w/ Digital Pot Option Cable Kit - Connect to HIM Cradle Port 0.33 Meters (1.1 Feet) 1 Meter (3.3 Feet) 3 Meter (9.8 Feet) 9 Meter (29.5 Feet) Option Cable Kit - Connect to Comm Port 0.33 Meters (1.1 Feet) 1 Meter (3.3 Feet) 3 Meter (9.8 Feet) 9 Meter (29.5 Feet) IP 20 (NEMA/UL Type 1) Door Mounted Bezel Kit 1201-HAB ➊ 1201-HAP ➊ 1201-HA1 ➊ 1201-HA2 ➊ IP 66 (NEMA/UL Type 12/UL Type 4X Indoor) Enclosures 1201-HJP ➊ 1201-HJ2 ➊ HIMs not mounted in the HIM cradle but connected to the HIM Cradle Port 1202-H03 1202-H10 1202-H30 1202-H90 HIMs not mounted in the HIM cradle but connected to the 1202-C03 HIM Comm Port 1202-C10 1202-C30 1202-C90 User Supplied IP 20 (NEMA/ 1201-DMA UL Type 1) Enclosures and HIM ➊ If this option is mounted separately or used as a hand-held device, an Option Cable Kit is required. 10 Allen-Bradley 1397 Digital DC Drive Accessories & Spare Parts Description Blower Motor/Starter, 0.4-0.63A Blower Motor/Starter, 0.63-1.0A Blower Motor/Starter, 1.0-1.4A Blower Motor/Starter, 1.4-1.8A Blower Motor/Starter, 1.7-2.4A Blower Motor/Starter, 2.2-3.1A Blower Motor/Starter, 2.8-4.0A Blower Motor/Starter, 3.5-5.0A Blower Motor/Starter, 4.5-6.5A Blower Motor/Starter, 6.0-8.5A Blower Motor/Starter, 7.5-11.0A Pulse Encoder Interface AC Tach Interface Module Enhanced Field Supply for 230/460V & 10A Enhanced Field Supply for 230/460V & 20A Regulated Field Supply, 4A Regulated Field Supply, 10A Regulated Field Supply, 15A Control Interface, 115V AC I/O Expansion Card 1397-FC0300V Fuse Conv., 3-60 Hp @ 460V to 1.5-30 Hp @ 230V 460V TO 230V Fuse Conv.,75-150 Hp @ 460 to 40-75 Hp @ 230 Line Disconnect, 1.5-25 Hp @ 230V, 3-50 Hp @ 460V Line Disconnect, 30 Hp @ 230V, 60 Hp @ 460V Line Disconnect, 30-60 Hp @ 230V,75-125 Hp @ 460V Line Disconnect, 75 Hp @ 230V, 150 Hp @ 460 Disconnect Switch, 200 Hp, 460V AC Disconnect Switch, 250-300 Hp,460V AC Disconnect Switch, 500 Hp @ 460V AC Disconnect Switch, 600 HP @ 460V AC Catalog Number 1397-MB006 1397-MB010 1397-MB014 1397-MB018 1397-MB024 1397-MB031 1397-MB040 1397-MB050 1397-MB065 1397-MB085 1397-MB110 1397-PE 1397-AC 1397-FS3010 1397-FS3020 1397-FS2004 1397-FS2010 1397-FS2015 1397-L10 1397-L11 1397-FC030 1397-FC075 1397-DS050 1397-DS060 1397-DS125 1397-DS150 1397-DS200 1397-DS300 1397-DS500 1397-DS600 Allen-Bradley 11
1397-U7FN-HA2-DS050-PE 价格&库存

很抱歉,暂时无法提供与“1397-U7FN-HA2-DS050-PE”相匹配的价格&库存,您可以联系我们找货

免费人工找货