Guard Locking Switches
Atlas 5 Specifications
Standards EN954-1, ISO13849-1, IEC/EN602041, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems CE marked for all applicable directives, cULus and CSA
Category
Approvals Safety Contacts
Atlas 5 2 N.C. direct opening action 1 N.O. direct opening action Atlas 5 trapped key (left hand) 2 N.C. direct opening action 1 N.O. direct opening action Utilization Cat.
Description
The Atlas 5 is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and ensures that it remains isolated while the guard is open. The guard may only be opened when a signal is applied to the internal solenoid which releases the lock mechanism. A heavy-duty switch, the Atlas 5 locking mechanism withstands forces up to 5500N (1236lbs.) and the die-cast alloy housing is ideal for use in harsh environments. A unique feature of the Atlas 5 is its patented selfaligning head that tolerates actuator or guard misalignment, making it particularly useful for heavy machine guards. The Atlas 5 is designed for machines that do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard. With 2 safety (N.C.) contacts and 2 auxiliary (N.O.) contact, Atlas 5 is ideal for PLC controlled machines.
AC 15 AC (Ue) 500V 250V 100V (le) 1A 2A 5A DC 250V 0.5A, 24V 2A 500V 500VA 10A 5V. 5mA DC > 2mm contact block (Ui) 500V (Uimp) 2500V 1 N.O. 8mm (.31in.) 12N (2.7 lbs) 160mm per sec (6.3 in. per sec) 2 Cycle per sec Die cast alloy Stainless Steel IP65 3 x M20 or 3 x 1/2in NPT or quick disconnect -10°C to +60°C (14°F to +140°F) 4 x M5 1,000,000 operations 1,000,000 operations 1200g (2.65lbs) Red 5500N (1236lbs) 300mm end entry, 800mm entry front 24V AC/DC or 110V AC or 230V AC (solenoid) 13W typical 100% ED 100% duty
Maximum Switched Current/ Volt/Load Thermal Current (lth) Min Current Safety Contact Gap Rtd. Insulation Voltage Rtd. Impulse withstand Volt Auxiliary Contacts Actuator Travel for Positive Opening Break Contact Min Force Max Actuation Speed Max Actuation Frequency Case Material Actuator Material Protection Conduit Entry Operating Temperature Fixing Mechanical Life Electrical Life Weight Colour Max Holding Force Min Operating Radius Power Supply Solenoid Power Solenoid Rating
Features
• • • • Mechanical lock High locking force—5500N (1236lbs.) Heavy duty die-cast alloy housing ideal for harsh environments Patented self-aligning head tolerates actuator misalignment
3-32
Interlock Switches
Guard Locking Switches
Atlas 5 Product Selection
Contacts Type Actuator Safety Aux. Solenoid Voltage 24V AC/DC Standard Atlas 5 LH Key Lock Standard 2 N.C. 1 N.O. 110V AC/DC 230V AC/DC 24V AC/DC 110V AC/DC 230V AC/DC Catalogue Number M20 Conduit 440G-L07264 440G-L07263 440G-L07262 440G-L07255 440G-L07254 440G-L07253 1/2in NPT 440G-L07258 440G-L07257 440G-L07256 440G-L07249 440G-L07248 440G-L07247 Quick Disconnect 440G-L07298 440G-L07299 440G-L07300 440G-L07301 440G-L07302 440G-L07303
M23 mating cable 2m (6.5ft). See page 15-13 for details and additional lengths.
889M-F12AH-2
Accessories
Description For Dimensions refer to page Catalogue Number
Standard Actuator
14-3
440G-A07136
Replacement End Cap
14-3
440G-A07180
Fully Flex Actuator
14-3
440G-A07269
3-33
Interlock Switches
Guard Locking Switches
Atlas 5 Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
) (31.5 800 R Min
12 (0.47) 23 (0.91) 5 (0.2) 10 (0.39)
56 (2.2) 23 (0.91) 30 (1.18)
2 Manual Lock Release Points 17 (0.67) Lock Unlock
52 (2) Ctrs 14 (0.55)
4 X M5 5 (0.2) 163 (6.4) Ctrs 184 (7.24) 13 (0.51)
56 (2.2)
25 (0.98) 16 (0.63)
43 (1.69)
12 (0.47)
90 (3.54)
80 (3.15)
56 (2.2)
16 (0.63) LH Key Lock style Only 5 (0.2) 95 (3.74)
25 (0.98)
Front Entry Actuator Hole
Typical Wiring Diagrams
Guard Open—Solenoid De-energized Safety Safety Aux Aux AC/DC Solenoid Supply Terminal Configuration Machine in Run Condition
A1 A2 AC/DC 100% ED. 5 7 1 6 8 4
1
1 2 3
2
4 5
2
6 7
1
8 A1 A2 E
2
3
Lid Illumination Only
Connector Pinout 1 3 4 6 7 8 9 10 5 2 12
Terminal A1 A2 5 6 7 8 1 2 3 4 Ground
Contact Solenoid Power N.C. N.C. N.O. N.O.
5/6 7/8 1/2 3/4 19 13.5
Contact Action
Contact Open Contact Closed Actuator withdrawal distance from full insertion 20 12 0mm
8 7 6 5 12
9 11
1 10 2 3 4
3-34
R Min 300 (11
.8)
Interlock Switches
Guard Locking Switches
Atlas 5 Application Details
CU 2 Stop Motion Detector Unit
Used with Atlas for machines with constant or variable over run. Gives a timed delay to the lock/release signal. Fail safe and adjustable to a range of times from 0.1 seconds up to 40 minutes. For more details, see the Monitoring Safety Relay section in this catalogue.
CU 1 Timer Unit
Used with Atlas for machines with constant overruns. Gives a timed delay to the lock/release signal. Failsafe and adjustable to a range of times from 0.1 seconds up to 40 minutes. For more details, see the Safety monitoring relay section in this catalogue.
Minotaur MSR6R/T Monitoring Safety Relay Unit
Ensures a maximum level of safety by monitoring all wiring in the safety circuit including switches and contactors. Any fault and the power to the machine is switched off. Other Minotaur units are available, see the Safety monitoring relay section in this catalogue.
3-35