0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
440G-S36005

440G-S36005

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    440G-S36005 - Guard Locking Switches - Allen-Bradley

  • 数据手册
  • 价格&库存
440G-S36005 数据手册
Interlock Switches Guard Locking Switches Spartan Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems CE marked for all applicable directives, cULus and TUV Nord 2 N.C. or 3 N.C. direct opening action AC 15 AC (Ue) 500V 250V 100V (le) 1A 2A 5A DC 250V/0.5A 24V/2A Category Approvals Safety Contact Utilization Cat. Description The Spartan is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and ensures that it remains isolated while the guard is open. It is available in two contact configurations: two safety (N.C.) contacts and one auxiliary (N.O.) contact or three safety (N.C.) contacts. The Spartan head has two entry slots and it can be rotated to provide four actuator entry points. A blanking plug is provided to seal the unused slot. The guard may only be opened when a signal is applied to the Spartan’s internal solenoid which releases the lock mechanism. Therefore the Spartan is ideal for machines which do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard. The locking mechanism withstands forces up to of 1200N (270lbs.) and an LED provides visual indication of switch status. A catch kit with actuator alignment is also supplied to relieve stress on the locking solenoid and to protect the unit from actuator damage due to poor guard alignment. Manual release points with security screws or special key allow the locked Spartan to be released in the event of total power failure on a machine. Maximum Switched Current/ 500V/500VA Volt/Load Thermal Current (lth) Min Current Safety Contact Gap Rtd. Insulation Voltage Rtd. Impulse withstand Volt Auxiliary Contacts Pollution Degree ➊ Max Actuation Speed Max Actuation Frequency Case Material Actuator Material Protection Conduit Entry Operating Temperature Fixing Mounting Mechanical Life Electrical Life Weight Colour Max Holding Force Min Operating Radius LED Indication Power Supply Solenoid Power 10A 5V 5mA DC >2mm 500V 2500V 1 N.O. 3 160mm/second (6.3 in/sec) 1 cycle/second UL Approved glass filled polyester Stainless steel IP 67 1 x M20 or quick disconnect style -20°C to 60°C (-4°F to +140°F) 2 x M5 Any position 1,000,000 operations 1,000,000 operations 260g (0.57 lb) Red 1200N (270lbs) 175mm (6.9in) Solenoid monitor LED 24V AC/DC, 110V AC, 230V AC (solenoid) Typically 7W 100% ED Features • • • • • Power to release Lid mounted status indication High locking force—1200N (270lbs.) 2 N.C. & 1 N.O. or 3 N.C. Rotatable head: 4 possible key entry slots ➊ Conductive pollution occurs, or dry, non conductive pollution occurs which becomes conductive due to condensation. Typical Applications Note: Lift-off guards require good alignment when using tongue actuated interlock switches. IMPORTANT: It must not be possible to lift the guard without actuating the interlock. An interlock on either side may be required. 3-24 Interlock Switches Guard Locking Switches Spartan Product Selection Contacts Actuator Solenoid Voltage 24 V AC/DC Safety 2 N.C. 3 N.C. 2 N.C. Standard 110 V AC/DC 3 N.C. 2 N.C. 3 N.C. Aux. 1 N.O. — 1 N.O. -1 N.O. — M20 Conduit 440G-S36001 440G-S36007 440G-S36003 440G-S36009 440G-S36005 440G-S36011 Catalogue Number M20 Conduit/ 1/2in Adaptor 440G-S36044 440G-S36047 440G-S36045 440G-S36048 440G-S36046 440G-S36049 Quick Disconnect 440G-S36058 440G-S36059 440G-S36060 440G-S36061 440G-S36062 440G-S36063 230V AC/DC Mating cable 2m (6.5ft). See page 15-13 for details and additional lengths. 889M-F12X9AE-2 Accessories Description For Dimensions refer to page Catalogue Number Replacement Actuator with Catch Retainer and Guide 14-4 440G-A36050 Emergency Override 14-4 440G-A36026 3-25 Interlock Switches Guard Locking Switches Spartan Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. 14.5 (0.57) 35 (1.38) 12 (0.47) 120 (4.72) Conduit Entry (M20) 31 (1.22) 37 (1.46) 8 (0.31) 3 N.C. Safety Circuit 3 40 (1.57) 9 (0.35) Emergency Release Points 7 (0.28) 5 (0.2) 58 (2.28) 52 (2.05) 40 (1.57) Key Ø5.5 (0.22) 8 (0.3) 34.5 (1.36) Typical Wiring Diagrams 2 N.C. + 1 N.O. Auxiliary Circuit Safety Circuit 2 Safety Circuit 1 AC/DC Solenoid Power 22 34 33 21 20.5 (0.81) 5.5 (0.22) Safety Circuit 2 Safety Circuit 1 14 (0.55) 22 32 31 21 12 A2 11 A1 AC/DC Solenoid Power 12 A2 11 A1 Solenoid AC/DC 100% ED. Solenoid AC/DC 100% ED. 2 N.C. + 1 N.O. Connector Pinout 1 3 4 6 7 8 9 10 12 Terminal A1 A2 11 12 21 22 33 34 Contact Solenoid Power N.C. N.C. N.O. Ground 2 N.C. + 1 N.O. 12 11/12 21/22 33/34 6 0mm 12 11/12 21/22 33/34 3 N.C. Terminal A1 A2 11 12 21 22 31 32 Contact Solenoid Power N.C. N.C. N.C. 8 7 6 5 12 9 11 1 10 2 3 4 Contact Action Contact Open Contact Closed Actuator withdrawal distance from full insertion 3 N.C. 6 0mm 2.5 2.5 3-26 Interlock Switches Guard Locking Switches Spartan Application Details 4 possible actuator entry positions 1 2 Locking Force = ≤1200N 3-27
440G-S36005 价格&库存

很抱歉,暂时无法提供与“440G-S36005”相匹配的价格&库存,您可以联系我们找货

免费人工找货