Safeguarding Applications
Light Curtains
POC, 440L-M8100 (Muting), Dual Channel
+24V DC Bulletin 100S or 700S
56
POC Receiver
1 2 7 6 5 3 4 1
POC Sender
2 7 34
No. Conn.
1
2
3
4
5
6
7
8
9 10
11
12
13
14
15
16
No. Conn.
K1
K2
Brown
Brown
Yellow
Green
Green
White
White
Black
Black
Gray
Blue
Blue
17 18 19 20
21
22
23
24
25
26
27 28
29
30
31
32
33
440L-M8100
34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62
+ - +63 64 65 66
+ A1 + A2
+ B1 + B2
L1 L2 L3 K1
H1 S1
Muting Lamp Restart Lamp
K2
Gnd PE
Four Muting Sensors PNP Output
M
Circuit Status
The light curtain is not detecting the presence of any objects. The output contactors, K1 and K2 are de-energized.
Operating Principle
With no object in the sensing field, pressing and releasing S1 will cause the outputs to energize. When an object enters the sensing field, the outputs will de-energize and the restart lamp flashes. To start muting, the protection field must be free and the outputs K1 and K2 energized. During the muting period, the mute inputs must stay activated, without interruption, when changing from A1 & A2 to B1 & B2. If an object remains in the protected sensing field after a power interruption, the object can be moved out of the protected field through the actuation of a spring return, key operated switch S2 (not shown). To prevent a steady override, an additional contact of S2 can be integrated into the control system.
Fault Detection
If either contactor K1 or K2 sticks ON, the other functioning contactor will turn the load OFF. The outputs of the 440L-M8100 are monitored PNP outputs. A short across S1 will prevent the operation of the output circuits. A fault of the muting sensor will be detected so that new muting is prevented. If the muting lamp is not connected, is defective or is shorted, muting can not be started.
18-4