0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
440L-M8500

440L-M8500

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    440L-M8500 - Safety Light Curtain Interfaces - Allen-Bradley

  • 数据手册
  • 价格&库存
440L-M8500 数据手册
Presence Sensing Safety Devices Safety Light Curtain Interfaces 120V AC Power Supply and Safety Relay Specifications Input Power Power Consumption Inputs Maximum Input Resistance Reset Outputs Output Rating N.O. B300, AC15, 5A/250V AC N300, DC13, 3A/24V DC Min. Switched Current/Voltage 10mA/10V 1 second 15ms K1 Green = Power Green = K1 Closed, if K1 alone is lit, check for short across reset button K2 Green = K2 Closed Operating Temperature Humidity Enclosure Protection Max. Conductor Size Weight Electrical Life 222V AC/4A/880VA 100,000 operations cos 0 = 0.35 Maximum Operating Frequency Mechanical Life Vibration Shock Recovery Time 1200 cycles/hour 2,000,000 operations 0.35mm 10-55Hz 10g, 16ms, 100 shocks 100ms -5°C to +55°C (+23° to +131°F) 90% RH NEMA 4, IP65 1 x 2.5mm2 (14AWG) stranded 1 x 4mm2 (12AWG) solid 4886/5113g (10.75/11.25lbs) 120/230V AC 2W/4W 1 N.C. or 2 N.C. or 2 PNP (light curtain) 110 ohms Automatic/Manual 3 N. O. Safety 1 N.C. Auxiliary nonsafety Description The Allen-Bradley Guardmaster 120V AC interface box consists of a NEMA 4 rated lockable metal enclosure, a DIN mount 3amp, 24V DC power supply and either a single or dual 22.5mm safety relay(s). The single safety relay module provides 3 N.O. safety and one N.C. auxiliary (nonsafety) “potential free” relay outputs. The dual safety relay configuration allows for two pairs of safety light curtains to independently control one or two machines. The safety relay(s) can be configured for manual reset or automatic reset. The resetting function can be through the key switch mounted on the front cover of the interface box. Pre punched holes located on the bottom of the enclosure allow for easy wiring of the system. Power ON Delay Response Time Relay Module Indication LEDs 2-54 Presence Sensing Safety Devices Safety Light Curtain Interfaces 120V AC Power Supply and Safety Relay Product Selection Safety Outputs 3 N.O. 6 N.O. Auxiliary Outputs 1 N.C. 2 N.C. Power Supply 24V DC Catalogue Number 440L-M8400 440L-M8500 Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. 200.0 (7.87) 161.9 (6.37) 301.6 (11.87) 3.17 (0.12) 1.77 (0.07) 63.5 (2.5) 104.7 (4.12) 22.2 (0.87) 2-55 Presence Sensing Safety Devices Safety Light Curtain Interfaces 120V AC Power Supply and Safety Relay Typical Wiring Diagram M8400 Single Relay L Fuse Fuse L1 Light Curtain Interface Box K3 K4 Fuse 123 45 6 789 10 11 12 13 14 15 16 17 18 Fuse Machine Prime Mover Elements Relay Man. Restart (Jump 15 & 16, 17 & 18) Transmitter Receiver Relay Auto Restart (Jump 16 & 17) Relay Man. Restart w/ MPCE Feedback (N.C. contacts between 15 & 16, Jumper 17 & 18) L2 K3 K4 OSSD1 OSSD2 GND GND +24V +24V PE TEST TEST PE K3 K4 Relay Auto Restart w/ MPCE Feedback (N.C. contacts between 16 & 17) Man. Restart Internal to Light Curtain (Jumper 16 & 17) To red wire of Safe/GuardShield Receiver K3 OR +24V (Jumper Req’d if mts not used) Arc Suppression Devices N K4 2-56 Presence Sensing Safety Devices Safety Light Curtain Interfaces 120V AC Power Supply and Safety Relay Typical Wiring Diagram M8500 Dual Relay L1 L LC1 K3 LC2 K5 Light Curtain Interface Box Fuse Fuse Fuse K5 123 45 6 789 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 LC1 LC2 Transmitter Transmitter Relay Man. Restart Receiver Receiver (Jump 17 & 18, 19 & 20) (Jump 18 & 19) K3 K4 (Jump 20 & 21, 22 & 23) Relay Auto Restart (Jump 21 & 22) K5 K6 OSSD1 OSSD2 GND +24V PE OSSD1 OSSD2 GND +24V PE Relay Man. Restart w/MPCE Feedback GND +24V PE TEST TEST GND +24V PE TEST TEST (N.C. contacts between (N.C. contacts between 17 & 18, Jumper 19 & 20) 20 & 21, Jumper 22 & 23) K3 K4 K5 K6 Relay Auto Restart w/MPCE Feedback (N.C. contacts between 18 & 19) (N.C. contacts between 21 & 22) Man. Restart Internal to To red wire of Light Curtain Safe/GuardShield Relay Auto Receiver (Jumper 21 & 22) OR (Jumper Req’d if mts not used) OR (Jumper Req’d if mts not used) Arc Suppression Devices 100 Ω, 2.2 µF) K3 +24V To red wire of +24V Safe/GuardShield Receiver N K4 LC1 LC2 Fuse K6 K4 K6 2-57
440L-M8500 价格&库存

很抱歉,暂时无法提供与“440L-M8500”相匹配的价格&库存,您可以联系我们找货

免费人工找货