Presence Sensing Safety Devices
Safety Laser Scanner
SafeZone Specifications
Standards Safety Category Approvals Laser Protection Class Range for a Safe Detection of Objects the “Nominal Leg” Protective Field Res. Time Maximum Angle Wavelength IEC61496 Type 3 ESPE acc. to EN 61496-1 CE marked for all applicable directives, cULus, IEC 60825 Laser Class 1 (eye safe) 0 to 6m (0 to 19.6ft) (includes safety supplement) 280ms 300° 905nm 5.76KHz + 5% 8Hz + 5% 300° 70mm (2.8in) at 6m (19.6ft) 0.5° per IEC 2-6, frequency range 10-55Hz, amplitude: 0.35mm per IEC 2-29, acceleration 10g, pulse duration: 16ms 15 mrad (0.86°) 30mm (1.18in) 30mm (1.18in) 24V DC ± 25% (via a safety insulating transformer acc. to IEC 742) 2A for 100ms 24W total Aluminium IP 65 3.0kg 0°C ... 50°C (32°F to 122°F) -20°C ... 70°C (-4°F to 158°F) RS 232: 9600 baud, 8 data bits, 1 stop bit, no parity Potential-free relay outputs, max. 2A, max. 30V, purely resistive load, number of operations; 2 million
Measurement & Toler. Range 0 to 7.5m (0 to 24.6ft)
Description
The SafeZone Safety Laser Scanner is an optoelectronic device that uses the diffuse reflection of emitted infrared light to determine the intrusion of a person or object within a defined area. A rotating deflection unit periodically emits Class 1 infrared laser light pulses over a 300° angular range to create a detection zone which is two dimensional. The reflected light is processed by the SafeZone, which will send a stop signal by switching the state of its safety relay outputs, if it is determined that a person or object is within the predefined detection zone. Two zones can be created within the maximum scanning range of the SafeZone through the use of the SafeZone’s Windows based software. The “Safety Zone” is configurable for a 6m (19.7ft) radius and the “Warning Zone” up to a 7.5m (24.6ft) radius. The SafeZone can be used in stationary applications for horizontal detection in a defined protection zone, in vertical applications for whole body access detection, and on mobile safeguarding applications—AGVs (Automated Guided Vehicles). The maximum value of the machine’s stopping time plus the SafeZone’s response time must be calculated so that no person can gain access to a hazard point before the dangerous motion has ceased.
Pulse Frequency Scanning Frequency Scanning Angle Resolution Point Resolution Vibration Shock
Optics (Co-axial Transmitter and Receiver Optics) Laser Beam Divergence Focal Length Lens Diameter Power Supply Operating Voltage Switch on Current Power Consumption Material Enclosure Rating Weight Operating Temperature Storage Temperature Interfaces Data Interfaces to Computer Signal Outputs for Warning Field, OSSD 1, OSSD 2
Housing and Environmental Resistance
Features
• • • • 300° scanning angle Two programmable zones (Safety/Warning) Safety relay outputs Robust IP65 housing
2-68
Presence Sensing Safety Devices
Safety Laser Scanner
SafeZone Product Selection
1. Safety Laser Scanner
Catalogue Number 442L-SSFZN Description SafeZone Safety Laser Scanner, 24V DC
2. Cordsets
Catalogue Number Description Catalogue Number Description
442L-SCPWR
Power & Outputs 5m (16.3ft)
View of the Soldered Side of the 8-Pin Socket—Connects to SafeZone. Opposite End Individual Leads Pre-stripped
442L-SCCFG
Communication Cable for Configuration of Zones 5m (16.3ft)
View of the Soldered Side of the 14-Pin Socket Configuration Cable—Connects to SafeZone. Opposite End 9-Pin D-Sub Connector
Pin # 1 2 3 4 5 6 7 8
Signal 24V GND24 OSSD 2.1 OSSD 2.2 OSSD 1.1 OSSD 1.2 Warning field 1.1 Warning field 1.2 FE
Explanation 24V DC supply Ground Relay contact for protective field 2.1 Relay contact for protective field 2.2 Relay contact for protective field 1.1 Relay contact for protective field 1.2 Relay contact for warning field 1.1 Relay contact for warning field 1.2 Functional Ground (Shield)
Marking + S2 S2 S1 S1 A A FE
Colour Brown Blue White Grey Black Green Red Pink Thick Black
Pin # A C E G J L M
Signal GND RTS CTS TxD RxD --RES
Explanation Ground, RS 232 RS 232: Ready to send
Direction --Output
Level --24V 24V 24V 24V --24V ---
RS 232: Clear to send Input RS 232: Transmit data RS 232: Receive data No connection Reset (active LOW) No connection Output Input --Input ---
N through U
Note: The SafeZone Safety Laser Scanner is a Type 3 device with two N.O. relay outputs. In order to attain a Category 3 system, the SafeZone must be connected through a safety relay module which monitors both FSDs.
2-69
Presence Sensing Safety Devices
Safety Laser Scanner
SafeZone Product Selection (continued)
3. Safety Relays—Optional
Relay Input Dual Channel (MSR126.1T) 2 N.O. Dual Channel (MSR126.1R) None Safety Outputs Auxiliary Outputs Power Supply 24V AC/DC 115V AC 230V AC 24V AC/DC 115V AC 230V AC 24V AC/DC 1NC, 2NC, or Light Curtain or Laser Scanner MSR127TP MSR127RP MSR127TP 3 N.O. 1 N.C. 115V AC MSR127RP MSR127TP 230V AC MSR127RP Automatic/Manual Monitored Manual Automatic/Manual Monitored Manual Automatic/Manual Monitored Manual — Monitoring Manual Automatic/Manual Type Reset Catalogue Number 440R-N23114 440R-N23113 440R-N23112 440R-N23120 440R-N23119 440R-N23118 440R-N23132 440R-N23135 440R-N23131 440R-N23134 440R-N23130 440R-N23133 440R-C23139 Automatic/Manual or Monitored Manual
MSR 126
MSR 127RP
24V AC/DC 1 N.C. or 2 N.C. or Safety Mat or Light Curtain or Laser Scanner 2 N.C. 2 PNP Solid State
3 N.O.
115V AC
—
440R-C23137
230V AC
440R-C23136
MSR 131RTP
4. AccessoriesOptional
Products Power supply: Input85...265V AC Output24V DC, 3 Amps Catalogue Number
1794-PS3
5. Typical Wiring Diagrams Wiring SafeZone Outputs to a Safety Relay Module
24V DC OSSD 1.1 OSSD 2.1 Reset
SafeZone OSSDs directly to FSDs (contactors)—Category 1 System
OSSD 2.1
L1 L2 L3
Inputs
A1
SafeZone Safety Laser Scanner
MC 13 23 K1
OSSD 2.2
Safety Monitoring Relay
OSSD 1.1
K2
OSSD 1.2
* *
A2
OSSD 2.2 OSSD 1.2
Inputs
MC 14 24 K1 K2
M
* Shi ld
Suppression diode
K1
K2
Suppression diode K1 and K2 relays must have positively-driven contacts
GND lk
0V
2-70
Presence Sensing Safety Devices
Safety Laser Scanner
SafeZone Product Selection
5. Typical Wiring Diagrams (continued) SafeZone Warning Field Output
30V max L
Warning field 1
Warning field 2
0V
N
Dimensions—mm (inches)
176 (6.9) 56.5 (2.22)
178 (7.0) 137.5 (5.41) 15 (0.59) 19 (0.74)
24V DC Interface Signal 3.15 AT fuse
158 (6.22)
Name Plate Label
15.5 (0.61) 11 (0.43)
Warning Safety DIagnostics
Indication Lamps
Male Plug I4 Pin
Male Plug 8 Pin
4mm Hex Socket Chassis Ground 1mm2 to 2.5mm2
10 (0.39)
green red yellow yellow
X
Mounting Holes
Protective Cap Female Cable Connector 8 Pin ~ 60 (2.36)
115 (4.52)
Protective Cap
90 (3.54) min bend radius 120 (4.72) min bend radius
Female Cable Connector 14 Pin
Min 175 (6.88) distance
176 (6.9)
115 (4.52)
86 (3.38)
Threaded M4 x 10 4 places
Mounting Surface 144 (5.66)
2-71