Prosafe Trapped Key Interlock Switches Stopped Motion Units Specifications Standards EN292-1&2, EN1954-1, IEC/EN60204-1, EN1088, IEC/EN60947-5-1, ISO138491, ISO12100-1&2, ISO14119, GS-ET-19, AS4024.1 Cat. 3 per EN 954-1 (ISO 13849-1) BG and CE marked for all applicable directives 0°C to +40°C (32°F to +104°F) 95% RH 100,000 15.1kN (3398lbs) 14Nm (124lb•in) 316L Stainless Steel 316L Stainless Steel ABS Plastic Stainless Steel Barrel, Plastic Face Tamper resistant screws 2.0kg (4.4lbs) 24V DC, 110V AC and 230V AC 0.1 second to 40 minutes 2x inductive sensors Category Approvals Operating Temperature Humidity Mechanical Operations Maximum Shear Force to Key Maximum Torque to Key Material Trapped Key Components Face Plate Optional Box Inductive Sensors Assembly Fixing Weight Inputs Time Range Zero Speed Sensors Description The Stopped Motion Unit (SMU) is used in applications that require the detection of stopped motion of mechanical parts of a machine. The SMU uses inductive proximity sensors to detect motion and the CU2 control unit to monitor the sensors. The CU2 requires a PNP and an NPN output type proximity sensors. When the proximity sensors stop detecting movement, the CU2 activates its output, powering an internal solenoid. With the solenoid energized, one or two trapped keys can be removed from the SMU. The removable trapped keys (one or two) can be used to continue the next sequence in allowing access to the hazardous area. See the CU2 control unit for details on setting the delay time. Additional proximity sensors can be found in the Sensors catalogue. Features • • • • • • Stopped motion detection NPN and PNP proximity sensors Timed-delay output up to 40 minutes Category 1 Stop Replaceable code barrel assembly Optional IP65 enclosure The Prosafe Advantage Stainless steel construction. 5-16 Prosafe Trapped Key Interlock Switches Stopped Motion Units Product Selection (sensors not included) Type Solenoid Voltage 24V DC Single Key Out Panel Mounted 110V AC 230V AC 24V DC Dual Key Out Panel Mounted 110V AC 230V AC Contact Set 1 3 N.O. 40A 2 N.O. 20A 3 N.O. 40A 2 N.O. 20A 3 N.O. 40A 2 N.O. 20A 3 N.O. 40A 2 N.O. 20A 3 N.O. 40A 2 N.O. 20A 3 N.O. 40A 2 N.O. 20A Contact Set 2 1 N.O. 20A 1 N.C. 20A 1 N.O. 20A 1 N.C. 20A 1 N.O. 20A 1 N.C. 20A 1 N.O. 20A 1 N.C. 20A 1 N.O. 20A 1 N.C. 20A I N.O. 20A 1 N.C. 20A Catalogue Number 440T -MSMSE10➊ 440T -MSMSE11➊ 440T -MSMSE20➊ 440T -MSMSE22➊ 440T -MSMSE30➊ 440T -MSMSE33➊ 440T -MDMSE10➊➊ 440T -MDMSE11➊➊ 440T -MDMSE20➊➊ 440T -MDMSE22➊➊ 440T -MDMSE30➊➊ 440T -MDMSE33➊➊ ➊ Substitute the desired primary code for this symbol (key not included). See page 5-6 for code selection. Accessories Description Replacement Key Replacement Code Barrel Replacement Dust Cap Replacement Fuse Optional IP65 Plastic Enclosure 12mm Inductive Proximity Sensors 18mm 30mm Size Type — — 250V 500mA — NPN PNP NPN PNP NPN PNP Page Number 5-33 NA For use with 20A units For use with 40A units Catalogue Number 440T -AKEYE10⊗ 440T -ASCBE14➊ 440T -ASFC10⊗ 440R-A31562 440T -AIPB20 440T -AIPB23 872C-D3NN12-E2 872C-D3NP12-E2 872C-D5NN18-E2 872C-D5NP18-E2 872C-D10NN30-E2 872C-D10NP30-E2 4-67 ➊ Substitute the desired primary code for this symbol (key not included). See page 5-6 for code selection. ⊗ Substitute the desired code for this symbol. See page 5-6 for code selection. Approximate Dimensions—mm (inches) 250 (9.84) 160 (6.30) 150 (5.91) 70 (2.76) 70 (2.76) 226 (8.90) 216 (8.50) 118 (4.65) Optional ABS Box (440T-AIPB20) for 20 Amp Isolator One Key for STU (key not included) Nonremovable Key Two Keys for DTU (keys not included) 98 (3.86) 300 (11.81) 8 Holes 4.6 (0.18) Dia. 95 (3.74) 110 (4.33) 90 (3.54) 230 (9.06) Optional ABS Box (440T-AIPB23) for 40 Amp Isolator 5-17
440T-MSMSE30
1. 物料型号: - 单键输出面板安装型:24V DC(型号:440T-MSMSE101、440T-MSMSE111)、110V AC(型号:440T-MSMSE201、440T-MSMSE221)、230V AC(型号:440T-MSMSE301、440T-MSMSE331)。 - 双键输出面板安装型:24V DC(型号:440TMDMSE1001、440TMDMSE1101)、110V AC(型号:440TMDMSE2001、440T-MDMSE2201)、230V AC(型号:440TMDMSE3001、440TMDMSE3301)。

2. 器件简介: - 停止运动单元(SMU)用于需要检测机器机械部件停止运动的场合。SMU使用感应式接近传感器检测运动,并使用CU2控制单元监控传感器。当接近传感器停止检测到运动时,CU2激活其输出,为内部电磁铁供电。电磁铁通电后,可以从SMU中移除一个或两个锁定钥匙。

3. 引脚分配: - 输入:24V DC、110V AC和230V AC。 - 接触集1:3常开40A。 - 接触集2:1常开20A或2常开20A和1常闭20A。

4. 参数特性: - 标准:EN292-1&2, EN1954-1, IEC/EN60204-1, EN1088, IEC/EN60947-5-1, ISO13849-1, ISO12100-1&2, ISO14119, GS-ET-19, AS4024.1。 - 类别:Cat. 3 per EN 954-1 (ISO 13849-1)。 - 认证:BG和CE标记适用于所有适用指令。 - 工作温度:0°C至+40°C(32°F至+104°F)。 - 湿度:95%RH。 - 机械操作:100,000次。 - 最大剪切力至钥匙:15.1kN(3398磅)。 - 最大扭矩至钥匙:14Nm(124磅英寸)。

5. 功能详解: - 停止运动检测、支持NPN和PNP接近传感器、定时延迟输出长达40分钟、Category 1 Stop、可替换的编码套筒组件、可选IP65外壳。

6. 应用信息: - 适用于需要检测机器机械部件停止运动的场合,通过移除一个或两个锁定钥匙来允许进入危险区域的下一个序列。

7. 封装信息: - 锁定钥匙组件:316L不锈钢面盖、316L不锈钢ABS塑料盒。 - 组装固定:防篡改螺丝。 - 重量:2.0kg(4.4磅)。 - 可选IP65塑料外壳:适用于20A单元(型号:440T-AIPB20)和40A单元(型号:440TAIPB23)。
440T-MSMSE30 价格&库存

很抱歉,暂时无法提供与“440T-MSMSE30”相匹配的价格&库存,您可以联系我们找货