0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
442L-MDNET

442L-MDNET

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    442L-MDNET - Safety Light Curtain Interfaces - Allen-Bradley

  • 数据手册
  • 价格&库存
442L-MDNET 数据手册
Presence Sensing Safety Devices Safety Light Curtain Interfaces SafeShield DeviceNet Module Specifications Safety Category Approvals Power Supply Power Consumption Inputs Outputs Power On Delay Indication LEDs Impulse Withstand Voltage Pollution Degree Operating Temperature Nonsafety rated CE marked for all applicable directives and cULus 24V DC 1w RS 233 from SafeShield DeviceNet 1s See Indicator table 2500V 2 -5°C to +55°C (+23°F to 131°F) IP40 (NEMA 1) IP20 0.2–4mm2 (24–12 AWG) 0.4–0.5Nm (3.54–4.43lb•in) Polyamide PA 6.6 22.5mm DIN rail 320g (0.71lbs) N/A 10-55Hz, 0.35mm 10g, 16ms, 100 shocks Description The SafeShield DeviceNet interface is a nonsafety rated device that communicates diagnostic information from any SafeShield safety light curtain. In a compact 22.5m DIN rail mounted housing it allows easy wiring and configuration of DeviceNet parameters. Enclosure Protection Terminal Protection Conductor Size Torque Settings—terminal screws Case Material Mounting Weight Mechanical Life Vibration Shock Features • • • • • • Connects directly to DeviceNet networks Auto baud Change of State and strobe messaging Rotary DIP switches for MAC ID Compact 22.5mm housing Diagnostic capabilities • Weak signal • Alignment: number of beams, number of blocked beams, etc. • Output status • Setup configuration • LED diagnostics • System identification: product name, model, etc. • System status • System settings: fixed or floating blanking, auto power-up, etc. • Diagnostic: error codes, cause of lockout, troubleshooting suggestions, etc. Indicators Label Colour State OFF Green ON Steady Green Flashing Red Flashing Red ON Steady Green-Red-Green Off Flashing On Off Red Green Status Interface not powered, or waiting for Autobaud Interface active and allocated by master Interface active but not allocated by master Minor correctable fault (baud rate) Major fault (possible duplicate address Power up sequence Internal Fault Fault or Warning Require User intervention No Faults or Warnings No Safety Communication Not Safe, OSSD not active Safe, OSSD active Dnet Status Red/Green Comm Status Orange OSSD Status Red/Green 2-52 Presence Sensing Safety Devices Safety Light Curtain Interfaces SafeShield DeviceNet Module I/O Data Strobe and Change-of-State Output: Input Assembly = Status (0) Byte 1, Bit 7 6 5 4 3 Status Data Restart Beam Strength Device Warning Device Fault 0 Input Assembly = Modes (1) Byte 2, Bit 7 6 5 4 3 Floating Blanking Fixed Blanking Resolution Modes Restart Mode Range Mode Mode Mode Mode Input Assembly = Diagnostic (2) Byte 3, Bit 7 6 5 4 3 Diag. Code Diagnostic Codes Input Assembly = Beams (3) Byte 4, Bit 7 6 5 4 3 Beam Data Count of Beams 2 0 2 EDM Mode 2 1 0 1 0 1 0 OSSD 0 0 0 2 1 0 Product Selection Inputs Com. from SafeShield Safety Outputs N/A Auxiliary Outputs N/A Power Supply 24V DC Catalogue Number 442L-MDNET Approximate Dimensions—mm (inches) Approximate Dimensions are not intended to be used for installation purposes. 99 (3.89) 22.5 (0.88) 114.5 (4.5) Typical Wiring Diagram 24V DC Light curtain Out1 Out2 Reset L1 L2 L3 A1 S11 S52 S12 13 23 33 41 K1 MSR127RP K2 S21 S22 S34 A2 14 K1 0V 24 K2 34 42 M Light Curtain, Manual Reset, Monitored Output Black Blue White Red Shield DeviceNet Connection } 2-53
442L-MDNET 价格&库存

很抱歉,暂时无法提供与“442L-MDNET”相匹配的价格&库存,您可以联系我们找货

免费人工找货