0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
700-HN116

700-HN116

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    700-HN116 - Solid-State Relays - Allen-Bradley

  • 数据手册
  • 价格&库存
700-HN116 数据手册
Bulletin 700-SF Solid-State Relays Overview/Product Selection Bulletin 700-SF • • • • • • 3 A (resistive) Max. Continuous Load (Output) Current 264V AC or 52.8V DC Max. Load Voltage Range 4…24V DC Control/Input Voltage Photocoupler or Phototriac Isolation Option Between Control and Output Voltage LED Indicator for Input/Logic ON/OFF Status Monitoring 700-HN116 Socket Compatible Table Of Contents Product Selection . . . . . . . 47 Accessories . . . . . . . . . . . . 48 Specifications . . . . . . . . . . 49 Approximate Dimensions . . . . . . . . . . . . 50 Input-to-Output Isolation Method Photocoupler Phototriac Zero Cross Function Yes No LED Indicator Rated Output (Load) Max. Current and Voltage Range Rated Input Control Voltage 5…24V DC 24V DC Cat. No. Factorystocked Item (Single Pack) ✔ ✔ 3 A at 100…240V AC 700-SFZY3Z25 700-SFTY3Z24 Photocoupler N/A Yes 3 A at 4…48V DC 4…24V DC 700-SFNY3Z25 ✔ 47 Bulletin 700-SF Solid-State Relays Accessories Description Pkg. Qty. Cat. No. Factorystocked Item Screw Terminal Socket — Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays. Order must be for 10 sockets or multiples of 10. Cat. No 700-HN116 10 700-HN116 ✔ DIN Rail Mounting Pack Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per package. Order must be for 10 rails or multiples of 10. Cat No. 199-DR1 10 199-DR1 ✔ Pre-printed identification tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N40 ✔ Blank identification tags — contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 ✔ Retainer Clip for Cat. No. 700-HN103 and -HN128 Sockets with 700-SF Relays and Cat. No. 700-HN116 Sockets Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN114B➊ ✔ Sample Retainer Clips ➊ Bulletin 700-SF must use 700-HN114 series B retainer clip. 48 Bulletin 700-SF Solid-State Relays Specifications Control/Input Ratings Cat. No. 700-SFZY3Z25 700-SFTY3Z24 700-SFNY3Z25 Rated Control Voltage 5…24V DC 24V DC 5…24V DC Operating Control Voltage Range 4…28V DC 19.2…28.8V DC 4…28V DC Control Voltage Levels Impedance 15 mA max. ➊ 2 kΩ ± 20% 1.5 kΩ + 20%/–10% ➋ Pick-up Voltage 4V DC max. 19.2V DC max. 4V DC max. Drop-out Voltage 1V DC min. 1V DC min. 1V DC min. Load/Output Ratings Applicable Load Cat. No. — 700-SFZY3Z25 700-SFTY3Z24 700-SFNY3Z25 Cat. No. Load Switching Method/Device Pick-up time Drop-out time Output ON voltage drop Output Leakage current Output VDRM VCEO (V) Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj (°C) (max.) Insulation resistance Dielectric strength Vibration resistance (max.) Shock resistance (max.) Ambient temperature Ambient humidity Standards Weight ➊ ➋ ➌ ➍ Rated Load Voltage — 100…240V AC 4…48V DC 700-SFZY3Z25 Triac Load Voltage Range — 75…264V AC 3…52.8V DC Characteristics Continuous Load Current (Resistive) Min. 0.1 A 0.1 A 0.1 A 700-SFTY32... Transistor 1 ms max. Max.➍ 3A 3A 3A Max. Inrush Current ➌ — 45 A @50/60 Hz, 1 cycle 18 A (10 ms) 700-SFNY3Z25 1/2 cycle of load power source + 1 ms max. 1.6V (RMS) max. 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 600 50 250 18 125 0.5 ms max. 2 ms max. 1.5V max. 5 mA max. (at 50V DC) 80 — — — 150 1/2 of output switching element cycle of load power source + 1 ms max. 2.5 mA max. (at 100V AC); 5 mA max. (at 200V AC) 600 50 250 18 125 100 MΩ min. (at 500V DC) 1,500V AC, 50/60 Hz for 1 min. 10…55 Hz, 1.5 mm double amplitude (10 G) 1,000 m/s2 (100 G) Operating: –30…80°C (–22…176°F) with no icing or condensation Storage: –30…100°C (–22…212°F) with no icing or condensation 45…85% (no condensation) UL508, CSA C22.2, CE Approx. 50 g With constant current input circuit system, SSR impedance varies with a change in input voltage. Input impedance reaches its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to the “Inrush Current Resistivity” graphs on page 50 for more details. Refer to "Load Current vs. Ambient Temperature Characteristics" on page 50 for additional load current details. 49 Bulletin 700-SF Solid-State Relays Specifications, Continued/Approximate Dimensions Note: These data are non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity ➊ Inrush Current Resistivity ➊ 700-SF 700-SFZ… 700-SFT… 700-SFN… Inrush current (A, Peak) Load current (A) Ambient temperature (°C) Energizing time (ms) Inrush current (A) Energizing time (ms) ➊ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. Approximate Dimensions All units are in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes. Terminal Arrangement/ Internal Connections (Bottom View) 1 28 max. 3 5 21.5 max. 36.5 max. 42.5 max. – Input voltage 7 – Load 2 4(+) 6(–) (–) Input 8 + + Load (+) Note: 1. The plus and minus symbols shown in the parentheses are for DC loads. 2. The coil has no polarity. Note: The 700-SF is compatible with the 700-HN116 socket. Basic Application Considerations of Bulletin 700-SF High Density Mounting of Multiple SSRs If multiple SSRs are mounted side by side be aware that the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Connection For DC load switching, the 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals. Protective Component To Extend SSR Life When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built-in surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device . Select a varistor that meets the conditions of the load voltage outlined in the table below. Load Voltage 100…120V AC 200…240V AC 380…480V AC Varistor Voltage 240…270 V 440…470 V 820…1000 V 1000 A min. Varistor Surge Resistance Note: For additional details applying solid-state relays, refer to pub. number 700-AT001A-EN-E, Solid-State Relay Application Guide. Document available at http://www.theautomationbookstore.com. 50
700-HN116 价格&库存

很抱歉,暂时无法提供与“700-HN116”相匹配的价格&库存,您可以联系我们找货

免费人工找货