0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
700S-CF530XC

700S-CF530XC

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    700S-CF530XC - Safety Control Relays - Allen-Bradley

  • 数据手册
  • 价格&库存
700S-CF530XC 数据手册
Contactors & Control Relays Safety Control Relays 700S-CF Specifications Conformity to Standards IEC 60947-5-1 IEC 60947-5-1 Annex L — Special Requirements for Mechanically Linked Contact Elements EN50011, EN50005, EN50022 UL 508 VDE 0660 Description Bulletin 700S-CF Safety Control Relays provide mechanically linked, positively guided contacts, which are required in feedback circuits for modern safety applications. The positively guided N.C. auxiliary contacts will not change state if a N.O. contact welds. Consult your local sales office or price list for pricing information. CSA 22.2 No. 14 Approvals SUVA Third-Party Certified CE Certified CSA Certified UL Listed (File No. E14840, Guide No. NKCR) C-Tick not required Features • Positively guided/mechanically linked auxiliary contacts • Front-mounted auxiliary contact: – Permanently fixed – Protective cover to prevent manual operation – Red contact housing for easy identification – Incorporates IEC 60947-5-1 “Mechanically Linked” symbol • AC and DC operating coils • SUVA third-party certification Your order must include: • Catalogue number of the relays required, complete with coil suffix. • Catalogue number of adder decks, timers and accessories required. • If required, the part number of replacement coils. 9-17 Contactors & Control Relays Safety Control Relays 700S-CF Product Selection Type CF Control Relays — 8-Pole AC Coil Voltage AC-12 AC-15 Connection Diagrams Contacts Ith [A] 40°C 60°C 24/ 48V Ie [A] 120V 240V 400V 500V 600V 690V A1 K1 A2 14 22 34 44 Main Contacts 13 21 33 43 Auxiliary Contacts 53 61 71 81 NO NC Catalogue Number ! 700S-CF440⊗C 4 54 53 62 61 72 71 82 83 4 Main Contacts 20 20 10 10 10 6 2.5 1 1 A1 K1 A2 14 22 34 44 13 21 33 43 5 54 53 62 61 72 73 84 83 3 700S-CF530⊗C Adder Deck Contacts A1 13 21 33 43 10 6 6 6 5 3 1.6 1 1 K1 A2 14 22 34 44 6 54 62 74 84 2 700S-CF620⊗C ! All Catalogue Numbers are factory-stocked. ⊗ AC Coil Voltage Code The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 700S-CF440⊗C becomes Catalogue Number 700S-CF440DC . Voltage 50 Hz 60 Hz 50/60 Hz 12 R Q – 24 K J KJ 230240 VA – – 32 V – – 36 W V – 42 X – – 48 Y X KY 100 KP – KP 100110 – KP – 380400 N – – 110 D – KD 120 P D – 400415 G – – 127 S – – 200 KG – KG 200220 L KG KL 208 – H – 208240 – L – 220230 F – KL Voltage 50 Hz 60 Hz 50/60 Hz 230 – – KF 240 T A KA 277 – T – 347 – I – 380 – E – 400 – – KN 440 B N KB 480 – B – 500 M – – 550 C – – 600 – C – 9-18 Contactors & Control Relays Safety Control Relays 700S-CF Product Selection Type CF Control Relays — 8-Pole DC Coil Voltage AC-12 AC-15 Connection Diagrams Contacts Ith [A] 40°C 60°C 24/ 48V Ie [A] 120V 240V 400V 500V 600V 690V A1 K1 A2 14 22 34 44 Main Contacts 13 21 33 43 Auxiliary Contacts 53 61 71 81 NO NC Catalogue Number ! 700S-CF440⊗C 4 54 53 62 61 72 71 82 83 4 Main Contacts 20 20 10 10 10 6 2.5 1 1 A1 K1 A2 14 22 34 44 13 21 33 43 5 54 53 62 61 72 73 84 83 3 700S-CF530⊗C Adder Deck Contacts A1 13 21 33 43 10 6 6 6 5 3 1.6 1 1 K1 A2 14 22 34 44 6 54 62 74 84 2 700S-CF620⊗C ! All Catalogue Numbers are factory-stocked. ⊗ DC Coil Voltage Code The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 24V DC: Catalogue Number 700S-CF440⊗C becomes Catalogue Number 700S-CF440ZJC . Voltage Standard With diode suppressor 9 ZR — 12 ZQ — 24 ZJ DJ 36 ZW — 48 ZY — 60 ZZ — 64 ZB — 72 ZG — 80 ZE — 110 ZD — 115 ZP — 125 ZS — 220 ZA — 230 ZF — 250 ZT — 9-19 Contactors & Control Relays Safety Control Relays 100S-C and 700S-CF General Catalogue Number 700S-CF Contact Ratings — NEMA Minimum Contact Rating 17V 24V Contact Ratings — IEC AC-15 (solenoids, contactors) at rated voltage 48V 120V 240V 400V 480V/500V 600V 690V 40ºC AC-12 (Non-inductive, or slightly inductive loads, resistance furnaces) 60º C Ith 230V 400V 690V Switching DC Loads 24V DC-12 L Mechanically Linked Contacts➋ Aux. Contact (Frontmounted) A600, Q600 Location of welded N.O. contacts Main Front aux. 6A 6A 6A 5A 3A 1.6A 1A 1A 10A Catalogue Number 700S-CF Mechanical Life Electrical Life 20A 8 kW 14 kW 24 kW 6A Weight Terminal CrossSections Terminal Type 12A 9A 3.5A 0.55A 0.2A 9A 5A 2A 0.4A 0.16A 5A 3A 1.2A 0.6A 0.15A Solid Max. Wire Size per UL/CSA Tightening Torque Tightening Torque Terminal Size per IEC 60947-1 Flex. with Wire End Ferrule 2 x A4 AC-15 (240V, 3A) AC Op. Mechanism [Mil] [Mil] [g] 15 1.5 390 Left side aux. Right side aux. Yes! State of N.C. Contacts if N.O. contact welds Main Open Open Open ! Open ! Front aux. Open Open Open Open A600, P600 10 mA 10A 10A 10A 10A 6A 2.5A 1A 1A 20A 8 kW 14 kW 24 kW ! Side-mounted auxiliary contacts provide “mirror contact” performance. ➋ Defined in IEC 60947-5-1 annex L. Positive guidance is a relationship between contacts of opposite types (i.e., N.O. and N.C.) General Aux. Contact (Frontmntd.) 15 1.5 – Ith 230V 400V 690V 12A 9A 3.5A 0.55A 0.2A 9A 5A 2A 0.4A 0.16A 5A 3A 1.2A 0.6A 0.3A 2 x A4 48V 110V 220V 440V /R < 1ms, Resistive Loads 1 Conductor 2 Conductor [mm2] [mm2] 1…4 1…4 0.5…2.5 0.75…2.5 DC-14 L 24V 48V 110V 220V 440V 24V 48V /R < 15ms, Inductive 1 Conductor 2 Conductor [mm2] [mm2] [AWG] [lb-in] [Nm] 1.5…6 1.5…6 16…10 8.9…22 1…2.5 0.5…2.5 0.75…2.5 18…14 8.9…13.3 1…1.5 Loads with economy resistor in series DC-13 Switching electromagnets 110V 220V 440V 9-20 Contactors & Control Relays Safety Control Relays 100S-C and 700S-CF General (continued) Aux.Contact (Side-mounted) Contact Ratings — IEC AC-15 (solenoids, contactors) at rated voltage IEC 60947 120V 240V 400V 500V AC-12 (Non-inductive, or 40ºC slightly inductive loads, resistance furnaces), IEC60947 60ºC DC-13 (Solenoids and contactors), IEC60947 Ith Ith 24V 48V 110V 220V 440V Max. Wire Size per UL/CSA Tightening Torque Tightening Torque [AWG] [lb-in] [Nm] 6 5 3 1.6 10A 6A 3A 1.5A 0.6A 0.3A 0.2A 18…14 8.9…13.3 1…1.5 General (continued) Catalogue Number 700S-CF Rated Insulation Voltage Ui IEC UL; CSA Rated Impulse Strength Uimp High Test Voltage 1 minute (per IEC 947-4) Rated Voltage Ue AC DC Short-Circuit Protection IEC 1581 Fuse, gG Rated Frequency Ambient Temperature Storage Operation at nominal current Conditioned 15% current reduction after AC-1 at > 60°C Corrosion Resistance Catalogue Number 700S-CF –55…+80 °C (–67…176 °F) –25…+60 °C (–13…140 °F) –25…+70 °C (–13…158 °F) humid-alternating climate, cyclic, per IEC 68-2-30 and DIN 50 016, 56 cycles 2000m above mean sea level, per IEC 60947-4 115, 230, 400, 500, 690V 24, 48, 110, 220, 440V 10A 50/60 Hz, DC 2500V 690V 600V 8 kV Control Circuit Altitude Type of Protection Operating Voltage AC 50/60 Hz Pick-up Dropout DC! Pick-up Dropout Coil Consumption AC 50/60 Hz Inrush Seal DC Operating Times AC 50/60 Hz Pick-up Time Dropout Time DC Pick-up Time Dropout Time [ms] [ms] [ms] [ms] 15…30 10…60 40…70 7…15 Inrush/Seal [VA/W] [VA/W] [W] 70/50 8/2.6 6.5 [x Us] [x Us] [x Us] [x Us] 0.85…1.1 0.3…0.6 0.8…1.1 0.1…0.6 IP 2X (IEC 529 and DIN 40050) Finger Protection in connected state safe from touch by fingers and back of hand per VDE 0106, Part 100 ! For 9V DC, code ZR, use operating voltage 0.65…1.3 x Us. For 24V DC, code ZJ or DJ, use operating voltage 0.7…1.25 x Us. 9-21 Contactors & Control Relays Safety Control Relays 100S-C and 700S-CF Auxiliary Contacts For Use With Catalogue Number Catalogue Number Description NO NC Connection Diagrams -SA10 -4 -3 -3 -4 2 0 -SA20 1 0 -SB10 34 13 23 44 2 0 -SB20 ! AC Coils: Max. 2 N.O. auxiliary contacts may be mounted on the side. DC coils: Max. 1 N.O. auxiliary contact may be mounted on the side. No additional N.C. auxiliary contacts may be added to safety contactors and control relays listed in this publication. For additional contact configurations, consult your local Rockwell Automation/AllenBradley distributor. ➋ Double Numbering — Left-side mounting only is recommended for Catalogue Number 700S-CF… due to double numbering. Marking Systems Uniform labelling materials for contactors, motor starting equipment, timing relays and circuit breakers Description Label Sheet • Sheet with 105 self-adhesive paper labels, 6 x 17 mm Marking Tag Sheet • Sheet with 160 perforated paper labels, 6 x 17 mm • To be used with a transparent cover Transparent Cover • To be used with marking tag sheets Marking Tag Adaptors • 100 each • To be used with marking tag: System V4/V5 System Bul. 1492W Package Qty. 10 Catalogue Number 100-FMS 9-22 33 14 44 43 43 Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations ! • 1- and 2-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Electronic compatible contacts down to 17V, 10mA • L = Late break/Early make 13 14 -3 -4 -3 -3 Auxiliary Contact Blocks for Side Mounting without Sequence Terminal Designations ! • 1- and 2-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Electronic-compatible contacts down to 17V, 10mA -3 1 0 -4 -4 100S-C all 700S-CF all 100-SA10 -4 100S-C AC only 700S-CF AC only 100-SA20 100S-C09…C23 700S-CF all➋ 100-SB10 24 100S-C09…C23 AC only 700S-CF AC only➋ 100-SB20 10 100-FMP 100 100 100 100-FMC 100-FMA1 100-FMA2 Contactors & Control Relays Safety Control Relays 100S-C and 700S-CF Control Modules Connection Diagrams For Use With Catalogue Number Catalogue Number Description DC Interface (electronic) • Interface between the DC control signal (PLC) and the contactor AC operating mechanism • Control voltage 18…30V DC (24V DC nominal) • For coil voltage of 110… 240V AC • Suitable for all 100S-C contactor sizes, 9…85 A • Requires no additional surge suppression for the coils • Power consumption – 0.1 W at 18V DC – 0.25 W at 24V DC – 0.5 W at 30V DC RC Module AC Operating Mechanism Varistor Module AC/DC Operating Mechanism Diode Module DC Operating Mechanism 24…48V, 50/60 Hz 110…280V, 50/60 Hz 380…480V, 50/60 Hz 12…55V AC/12…77V DC 56…136V AC /78…180V DC 137…277V AC /181…350V DC 278…575V AC 12…250V DC K1M 100S-C with AC coils 700S-CF with AC coils (K1M) 100-JE Surge Suppressors For limitation of coil switching transients. • Plug-in, coil mounted • Suitable for all 100S-C contactor sizes, 9…85 A • RC, Varistor and Diode Versions 100S-C with AC coils 700S-CF with AC coils 100-FSC48 100-FSC280 100-FSC480 100-FSV55 100-FSV136 100-FSV277 100-FSV575 100S-C all 700S-CF all 100S-C with DC coils 100-FSD250 700S-CF with DC coils 9-23 Contactors & Control Relays Safety Control Relays 100-D Auxiliary Contacts Connection Diagrams For Use with Catalogue Number 100-D Left or right outside mounting 53 63 Description NO NC Catalogue Number 1 • Side-mounted • With IEC sequence terminal designations 2 1 100-DS2-11 0 73 83 54 64 • Electronically compatible auxiliary contacts • Ideal for use when switching low-power control circuits • Contact ratings: AC-1 250V, 0.1 A AC-15, DC-13 3…125V, 1…100V, 1 1 Labeling Material • Uniform labeling materials for contactors, motor protection devices, timing relays, and circuit breakers. Marking Systems (for 100-D95...D860 contactors) Description Label Sheet • 10 sheets with 105 self-adhesive paper labels each, 6 x 17mm Marking Tag Sheet • 10 sheets with 160 perforated paper labels each, 6 x 17mm • To be used with a transparent cover Transparent Cover • 100 each • To be used with marking tag sheets Marking Tag Adaptors • 100 each • To be used with marking tag: System V4/V5 System Bul. 1492W Package Qty. 10 Catalogue Number 100-FMS 9-24 74 84 100-D Left or right outside mounting 100-DS2-20 100-D Left or right outside mounting 100-DS2-B11 10 100-FMP 100 100-FMC 100 100 100-FMA1 100-FMA2 Contactors & Control Relays Safety Control Relays 100S-C and 700S-CF Auxiliary Contacts Internal Auxiliary Contacts Catalogue Numbers 100S-C09...100S-C23 Current Switching AC-12 Ith AC-15 at Rated Operating Voltage DC-13 at Rated Operating Voltage Continuous Current Rating per UL/CSA AC DC Short-Circuit Protection gG Fuse Type 2 Coordination Rated Impulse Voltage Uimp Insulation Voltage (between control and load circuit) per DIN, VDE 0106, Part 101 (NAMUR recommendation) [A] [A] 10A, 600V (NEMA A600) 5A, 600V (NEMA P600) 10A, 600V (NEMA A600) 2.5A, 600V (NEMA Q600) at 40°C at 60°C [A] [A] [V] [A] [V] [A] 10 10 10 10 5 2 25 20 24 48 120 240 400 415 500 690 6 5 2.5 1 24 48 110 220 400 0.7 0.25 0.12 6 5 6 2 6 5 10 6 24 48 120 240 400 415 500 690 3 2.5 1.6 1 24 48 110 220 400 0.7 0.25 0.12 Side-Mounted Auxiliary Contacts Catalogue Numbers 100-SA, 100-SB, 100-MC [A] [kV] [V] 10 8 250 17V, 10mA 10 6 500 17V, 10mA 100-SA, 100-SB: Mirror output performance per IEC60947-4 Annex F 100-MC: Mutually unrestricted between all N.O. and N.C. contacts Contact reliability per DIN 19240 without contamination, normal industrial atmosphere Mechanically Linked Contacts per IEC 60947-5-1 Annex L (SUVA Third-party certified) Terminals Terminal Type Wire Size per IEC 60947-1 Flexible w/Wire-End Ferrule 1 Conductor 2 Conductor Solid/Stranded Conductor 1 Conductor 2 Conductor Recommended Tightening Torque (min...max) Wire Size per UL/CSA Recommended Tightening Torque (min...max) [mm2] [mm2] [mm ] [mm2] Nm [AWG] [lb-in] 2 Mutually unrestricted between all N.O. and N.C. contacts 2 x A4 2 x A4 1…4 1…4 1.5…6 1.5…6 1...2.5 16…10 8.9…22 0.5…2.5 0.75…2.5 0.5…2.5 0.75…2.5 1…1.5 18…14 8.9…13.3 9-25 Contactors & Control Relays Safety Control Relays 100-DS2 Auxiliary Contacts Side-Mounted Auxiliary Contacts Catalogue Numbers 100-DS2 Conventional Current Switching AC-12 Ith AC-15 at Rated Operating Voltage at 40°C at 60°C [A] [A] [V] [A] DC-13 at Rated Operating Voltage Continuous Current Rating per UL/CSA AC DC Short-Circuit Protection gG Fuse Type 2 Coordination Rated Impulse Voltage Uimp Insulation Voltage (between control and load circuit) per DIN, VDE 0106, Part 101 (NAMUR recommendation) [A] [A] 10A, 600V (NEMA A600) 2.5A, 600V (NEMA Q600) [V] [A] 16 12 230 240 400 415 500 690 5.5 5 3 2.5 1.6 1 1… 100mA at 3… 125V 0.1 at 250V Electronically Compatible 24 48 110 220 440 5 2 0.7 0.25 0.12 [A] [kV] [V] 10 8 — Contact reliability per DIN 19240 without contamination, normal industrial atmosphere Mechanically Linked Contacts per IEC 60947-5-1 Annex L (SUVA Third-party certified) Terminals Terminal Type Wire Size per IEC 60947-1 Flexible w/Wire-End Ferrule 1 Conductor 2 Conductor Solid/Stranded Conductor 1 Conductor 2 Conductor Recommended Tightening Torque (min...max) Wire Size per UL/CSA Recommended Tightening Torque (min...max) [mm2] [mm2] [mm2] [mm2] Nm [AWG] [lb-in] 17V, 5mA Mirror contact performance per IEC 60947-4 Annex F 17V, 1mA Mirror contact performance per IEC 60947-4 Annex F 2 x A4 2 x A4 1…2.5 1…2.5 1… 4 1… 4 1.4…2.3 16…12 12…20 1…2.5 1…2.5 1… 4 1… 4 1.4…2.3 16…12 12…20 9-26 Contactors & Control Relays Safety Control Relays 100S-C and 700S-CF Dimensions—mm (inches) Dimensions are not intended for manufacturing purposes. Mounting Position c2 AC Contactors and Control Relays ➊ c1 c DC Contactors and Control Relays AC Contactors and Control Relays a 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) 72 (2-53/64) b 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 122 (4-51/64) c 119.5 (4-3/4) 136.5 (5-37/64) 139.5 (5-11/16) 156 (6-11/32) c1 114.5 (4-43/64) 131.6 (5-11/32) 134.6 (5-29/64) 150.5 (6-1/8) c2 6 (1/4) 6.5 (17/64) 6.5 (17/64) 8.5 (21/64) ∅d 2 - 4.5 (2 - 3/16) 2 - 4.5 (2 - 3/16) 2 - 4.5 (2 - 3/16) 4 - 5.4 (4 - 7/32) d1 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) d2 35 (1-25/64) 35 (1-25/64) 45 (1-25/32) 55 (2-11/64) Catalogue Number 100S-C09…100S-C23, 700S-CF 100S-C30, 100S-C37 100S-C43 100S-C60…100S-C85 DC Contactors and Control Relays a 45 (1-25/32) 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) 72 (2-53/64) b 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 122 (4-51/64) c 145.5 (5-49/64) 162.5 (6-7/16) 180.5 (7-5/32) 183.5 (7-17/64) 156 (6-11/32) c1 140.5 (5-37/64) 158 (6-1/4) 175.5 (6-61/64) 179 (7-3/32) 150.5 (6-1/8) c2 6 (1/4) 6 (1/4) 6.5 (17/64) 6.5 (17/64) 8.5 (21/64) ∅d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 4 - 5.4 (4 -7/32) d1 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) d2 35 (1-25/64) 35 (1-25/64) 35 (1-25/64) 45 (1-25/32) 55 (2-11/64) Catalogue Number 100S-C09Z...100S-C16Z, 700SCF 100S-C23Z 100S-C30...100S-C37 100S-C43Z 100S-C60D...100S-C85D Accessories Contactors with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Mechanical Interlock on side of contactor Interface Module on coil terminal side Surge Suppressor on coil terminal side Labelling with label sheet marking tag sheet with clear cover marking tag adapter for System V4/V5 marking tag adapter for System Bul. 1492W mm a+9 b + 24 a+9 b+9 b+3 +0 +0 + 5.5 + 5.5 (inches) (a + 23/64) (b + 15/16) (a + 23/64) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32) (+ 7/32) 9-27 Contactors & Control Relays Safety Control Relays 100S-D Contactors and Accessories Dimensions—mm (inches) Dimensions are not intended for manufacturing purposes. Mounting Position e2 e1 øe c1 e4 d1 ød d2 a c ➊ Catalogue Number 100S-D95, 100S-D110 100S-D95-EI…100S-D180-EI, 100S-D140, 100S-D180 100S-D210-EI…100S-D420-EI 100S-D630-EI…100S-D860-EI a 120 120 155 255 b 170 170 205 310 c 156 156 180 265 e3 b c1 110.5 110.5 110.5 110.5 ød 5.2 5.2 6.5 10 d1 145 145 180 230 d2 100 100 130 225 øe M6 M8 M10 M12 e1 16 20 25 40 e2 38.5 39 48 70 e3 147 160 193 291 e4 8 10 12.5 22 Contactor with Auxiliary contact block Mechanical interlock Frame terminal block Label holder 100-DS2… 100-DM… 100-DTB110 100-DTB180 100-DTB420 [mm] a + 13.5 each a+a b + 7 each b + 7 each b + 8.5 each c…+ 5 ➊ Convention DC coil contactors will have an additional auxiliary contact block mounted which will add 13.5mm (0.53in) to the “a” dimension on the right hand side. 9-28
700S-CF530XC 价格&库存

很抱歉,暂时无法提供与“700S-CF530XC”相匹配的价格&库存,您可以联系我们找货

免费人工找货