FRS3

FRS3

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    FRS3 - Non contact Switches - Allen-Bradley

  • 数据手册
  • 价格&库存
FRS3 数据手册
Interlock Switches Non contact Switches Ferrogard 3, 4 & 5 Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems CE marked for all applicable directives and cULus Safety Auxiliary Category Approvals Reed Contacts Operating Distance – Make FRS3 12mm (0.47in) 21mm (0.83in) FRS4 12mm (0.47in) 13mm (0.51in) FRS5 12mm (0.47in) NA Description The Ferrogard range of magnetically actuated switches offers non contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is opened, the action of the magnetic actuator being removed from the switches opens the N.C. safety contacts which are intended for the isolation of control power to a machine primary control element. The FRS 3, 4 and 5 have terminal connections. The user must drill a hole in the housing at a convenient location to allow the wiring to enter the housing. The cover is secured with anti-tamper security screws. Unlike some magnetic switches the Ferrogards have protected safety contacts to help ensure that they do not fail to danger. In addition, some versions have independent auxiliary signal contacts to indicate the guard condition. All Ferrogards have internal non-resettable overload protection on the safety contact. They should be protected by an external fuse rated as shown in the specifications table. Operating Distance – Break FRS3 FRS4 23mm (0.91in) 24mm (0.94in) FRS5 23mm (0.91in) 10mm (0.39in) 12mm (0.47in) NA Closing Time Dropout Time Bounce Time Initial Contact Resistance Initial Capacitance, Terminal to Terminal Initial Insulation Resistance Terminal to Terminal Safety Contact Switching Capability Safety Contact External Fusing Auxiliary Contact Switching Capability Min Initial Breakdown Voltage Operating Temperature Enclosure Protection Case Material Mounting Electrical Life Mechanical Life Vibration Shock 3.0ms 0.5ms 2.1ms 0.3ms 0.7ms 0.7ms 15mΩ 0.65pF 0.2pF 1.x.106 Ω 250V AC 2A max ≤1.6A quick blow 300V DC, 250V AC, 0.5A including inrush. 15VA/10W suitable for AC/DC circuits 600V AC 600V AC -10°C to +65°C (14° to 149°F) IP65 (NEMA 13) Red moulded ABS Plastic Any Position M4 mounting security screws included. 1 x 106 at rated loaded 10 x 106 10 to 200Hz 50g 1x106 Ω 10mΩ Features • • • • • Non contact actuation High tolerance to misalignment High switching current (up to 2A) Various contact arrangements Terminal connections 3-46 Interlock Switches Non contact Switches Ferrogard 3, 4 & 5 Product Selection Safety Contact Switching Capability Connection Housing Material Safety Contacts Auxiliary Contacts 1 N.C. 250VAC 2A Terminals ABS Plastic 1 N.C. 1 N.O. None Note: Contacts are described with the guard door closed, that is, actuator in place. Type FRS 3 FRS 4 FRS 5 Catalogue Number 440N-G02003 440N-G02008 440N-G02009 Accessories Description Replacement Actuator Page Number — Catalogue Number 440N-A02005 Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. Switch Actuator 30 (1.18) 2 Holes 4 Through 50 (1.97) = = 6 (0.24) = 36 (1.41) 4 (0.16) = 15 (0.59) 5 (0.2) 57 (2.24) 69 (2.72) 60 (2.36) 76 (2.99) 5 (0.2) 38.5 (1.52) = 2 (0.08) 7 (0.28) 38 (1.5) 6 (0.24) 25 (0.98) = 8 (0.31) 19.5 (0.77) Typical Wiring Diagrams FRS 3 FRS 4 FRS 5 1 2 3 4 Safety N.C. Fuse Externally Aux N.C. 1 2 3 4 Safety N.C. Fuse Externally Aux N.O. = = 1 2 Safety N.C. Fuse Externally Application Details See page 3-54 for operating principles and mounting examples. 3-47

很抱歉,暂时无法提供与“FRS3”相匹配的价格&库存,您可以联系我们找货

免费人工找货