GaAs 50 dB IC Voltage Variable Dual Control Attenuator DC–3 GHz
AT002N5-01, AT002N5-10 Features
I Dual Control Voltages I Low Insertion Loss I 7 Lead Hermetic Package I Capable of Meeting MIL-STD Requirements5
-01
0.220 (5.59 mm) 0.210 (5.33 mm) 0.063 (1.60 mm) TYP. 0.130 (3.30 mm) TYP. 0.130 (3.30 mm) TYP.
0.268 (6.81 mm) 0.252 (6.40 mm) 0.45 (1.14 mm) TYP. 0.160 (4.06 mm) 0.120 (3.05 mm) 0.031 (0.79 mm) MAX. 0.013 (0.33 mm) 0.007 (0.18 mm) 0.007 (0.18 mm) 0.003 (0.08 mm) 0.065 (1.65 mm) MAX.
Description
The AT002N5-01 is a GaAs IC FET absorptive attenuator. It provides up to 50 dB variable attenuation from DC–3 GHz under non-reflective conditions. This attenuator is recommended for fast response AGC circuits for commercial and high reliability applications. The AT002N5-10 is the gullwing version of this device for surface mount applications.
Electrical Specifications at 25°C
Parameter1 Insertion Loss2 Frequency4 DC–1.0 GHz DC–2.0 GHz DC–3.0 GHz DC–1.0 GHz DC–2.0 GHz DC–3.0 GHz DC–1.0 GHz DC–2.0 GHz DC–3.0 GHz 50 48 45 Min. Typ. 1.2 1.4 1.7 55 52 48 1.2:1 1.4:1 1.6:1 1.3:1 1.5:1 1.8:1 Max. 1.4 1.8 2.0 Unit dB dB dB dB dB dB
Attenuation Range
VSWR (I/O)
Operating Characteristics at 25°C
Parameter Switching Characteristics Condition Rise, Fall (10/90% or 90/10% RF) On, Off (50% CTL to 90/10% RF) Video Feedthru3 For All Attenuation Levels VLow = 0 to -0.2 V @ 20 µA Max. VHigh = -5 V @ 100 µA Max. 0.5–3 GHz 0.05 GHz Frequency Min. Typ. 10 15 20 0 -3 Max. Unit ns ns mV dBm dBm
Input Power for 1 dB Compression Control Voltages
1. All measurements made in a 50 Ω system, unless otherwise specified. 2. Insertion loss changes by 0.003 dB/°C. 3. Video feedthru measured with 1 ns risetime pulse and 500 MHz bandwidth. 4. DC = 300 kHz. 5. See Quality/Reliability section.
Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 • Email sales@alphaind.com • www.alphaind.com
Specifications subject to change without notice. 9/99A
1
GaAs 50 dB IC Voltage Variable Dual Control Attenuator DC–3 GHz
AT002N5-01, AT002N5-10
Typical Transfer Curve
F = 1 GHz, VP1 = 3.5 V 0 60 50 dB ± 4 dB -1.0 50
V1 V2 Control Voltages (V)
Attenuation (dB)
40 dB ± 2 dB 40 30 dB ± 1 dB 30 20 dB ± 0.5 dB 20 10 dB ± 0.2 dB 10 DC
-2.0 -3.0
V1 (Series)
V2 (Shunt) -4.0 -5.0 DC
10
20
30
40
50
60
1
2
3
Relative Attenuation (dB)
Frequency (GHz)
Relative Attenuation vs. Control Voltages
1. VP = FET pinchoff voltage
Attenuation (By State) vs. Frequency
PIN at 1.0 dB Compression (dBm)
F = 500 MHz 20 15 10 5 0 -5 0 5 10 15 20 25 30
Absolute Maximum Ratings
Characteristic RF Input Power (RF In) Control Voltage (VC) Operating Temperature (TOP) Storage Temperature (TST) Thermal Resistance (ΘJC) Value 10 mW > 500 MHz 0/-8 V Control 4 mW 50 MHz -8 V Control +0.2 V, -10 V -55°C to +125°C -65°C to +150°C 25°C/W
-10
0.345 (8.76 mm) ± 0.010 (0.25 mm) 0.215 (5.46 mm) 0.080 (2.03 mm) TYP. 0.045 (1.14 mm) TYP. 0.063 (1.60 mm) TYP. 0.013 (0.33 mm) 0.007 (0.18 mm) 0.007 (0.18 mm) 0.003 (0.08 mm) 0.060 (1.52 mm) TYP. 0.385 (9.78 mm) ± 0.010 (0.25 mm)
Attenuation (dB)
Attenuation vs. 1.0 dB Compression Point
Pin Out
GND
0.268 (6.81 mm) 0.252 (6.40 mm)
0.130 (3.30 mm) TYP. 0.065 (1.65 mm) MAX. 0.029 (0.74 mm) TYP.
J1
J2
0.030 (0.76 mm) 0.015 (0.038 mm)
GND
2
Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 • Email sales@alphaind.com • www.alphaind.com
Specifications subject to change without notice. 9/99A
GND
V2
V1
很抱歉,暂时无法提供与“AT002N5-01”相匹配的价格&库存,您可以联系我们找货
免费人工找货