AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Revision History
AS4C2M32D1A - 144 ball FBGA PACKAGE
Revision
Rev 1.0
Details
Preliminary datasheet
Date
Dec 2015
Alliance Memory Inc. 511 Taylor Way, San Carlos, CA 94070 TEL: (650) 610-6800 FAX: (650) 620-9211
Alliance Memory Inc. reserves the right to change products or specification without notice
Confidential
1 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Overview
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Fast clock rate: 200 MHz
Differential Clock CK & CK
Bi-directional DQS
DLL enable/disable by EMRS
Fully synchronous operation
Internal pipeline architecture
Four internal banks, 512K x 32-bit for each bank
Programmable Mode and Extended Mode registers
- CAS Latency: 2, 2.5, 3
- Burst length: 2, 4, 8
- Burst Type: Sequential & Interleaved
Individual byte write mask control
DM Write Latency = 0
Auto Refresh and Self Refresh
4096 refresh cycles / 64ms
Precharge & active power down
Operating Temperature:
- Commercial (0 ~ 70 °C)
- Industrial (-40 ~ 85 °C)
• Power supplies: VDD & VDDQ = 2.5V ± 0.2V
• Interface: SSTL_2 I/O Interface
• 144-ball 12 x 12 x 1.4mm FBGA package
- Pb and Halogen Free
The 64Mb DDR SDRAM is a high-speed CMOS
double data rate synchronous DRAM containing 64 Mbits.
It is internally configured as a quad 512K x 32 DRAM
with a synchronous interface (all signals are registered
on the positive edge of the clock signal, CK).
Data outputs occur at both rising edges of CK and CK .
Read and write accesses to the SDRAM are burst
oriented; accesses start at a selected location and
continue for a programmed number of locations in a
programmed sequence. Accesses begin with the
registration of a BankActivate command which is then
followed by a Read or Write command. The device
provides programmable Read or Write burst lengths of 2,
4, or 8. An auto precharge function may be enabled to
provide a self-timed row precharge that is initiated at the
end of the burst sequence. The refresh functions, either
Auto or Self Refresh are easy to use. In addition, 64Mb
DDR features programmable DLL option. By having a
programmable mode register and extended mode register,
the system can choose the most suitable modes to
maximize its performance. These devices are well suited
for applications requiring high memory bandwidth; result in
a device particularly well suited to high performance main
memory and graphics applications.
Table 1. Ordering Information
Org
AS4C2M32D1A-5BCN
2Mx 32
Commercial 0°C to 70°C
200
144-ball FBGA
AS4C2M32D1A-5BIN
2Mx 32
Industrial -40°C to 85°C
200
144-ball FBGA
Confidential
Temperature
Max Clock (MHz)
Product part No
2 of 63
Package
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 1. Ball Assignment (Top View)
1
2
3
4
5
6
7
8
9
10
11
12
A
DQS0
DM0
VSSQ
DQ3
DQ2
DQ0
DQ31
DQ29
DQ28
VSSQ
DM3
DQS3
B
DQ4
VDDQ
NC
VDDQ
DQ1
VDDQ
VDDQ
DQ30
VDDQ
NC
VDDQ
DQ27
C
DQ6
DQ5
VSSQ
VSSQ
VSSQ
VDD
VDD
VSSQ
VSSQ
VSSQ
DQ26
DQ25
D
DQ7
VDDQ
VDD
VSS
VSSQ
VSS
VSS
VSSQ
VSS
VDD
VDDQ
DQ24
E
DQ17
DQ16
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ15
DQ14
F
DQ19
DQ18
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ13
DQ12
G
DQS2
DM2
NC
VSSQ
VSS
VSS
VSS
VSS
VSSQ
NC
DM1
DQS1
H
DQ21
DQ20
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ11
DQ10
J
DQ22
DQ23
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ9
DQ8
K
CAS
WE
VDD
VSS
A10
VDD
VDD
NC
VSS
VDD
NC
NC
L
RAS
NC
NC
BA1
A2
NC
A9
A5
NC
CK
CK
NC
M
CS
NC
BA0
A0
A1
A3
A4
A6
A7
A8
CKE
VREF
Table 2. Ball Assignment by Name (FBGA 144Ball)
Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location
A0
M4
DQ6
C1
DQ24
D12
CK
L10
VDDQ
B6
VSS
E5
VSS
J7
VSSQ
G4
A1
M5
DQ7
D1
DQ25
C12
CK
L11
VDDQ
B7
VSS
E6
VSS
J8
VSSQ
G9
A2
L5
DQ8
J12
DQ26
C11
CKE
M11
VDDQ
B9
VSS
E7
VSS
K4
VSSQ
H4
A3
M6
DQ9
J11
DQ27
B12
M1
VDDQ
B11
VSS
E8
VSS
K9
VSSQ
H9
A4
M7
DQ10
H12
DQ28
A9
L1
VDDQ
D2
VSS
F5
VSSQ
A3
VSSQ
J4
A5
L8
DQ11
H11
DQ29
A8
CS
RAS
CAS
K1
VDDQ
D11
VSS
F6
VSSQ
A10
VSSQ
J9
A6
M8
DQ12
F12
DQ30
B8
WE
K2
VDDQ
E3
VSS
F7
VSSQ
C3
NC
B3
A7
A8/AP
A9
A10
NC
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
M9
M10
L7
K5
L6
A6
B5
A5
A4
B1
C2
DQ13
DQ14
DQ15
DQ16
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
F11
E12
E11
E2
E1
F2
F1
H2
H1
J1
J2
DQ31
DQS0
DQS1
DQS2
DQS3
DM0
DM1
DM2
DM3
BA0
BA1
A7
A1
G12
G1
A12
A2
G11
G2
A11
M3
L4
VREF
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDDQ
VDDQ
M12
C6
C7
D3
D10
K3
K6
K7
K10
B2
B4
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VSS
VSS
VSS
VSS
E10
F3
F10
H3
H10
J3
J10
D4
D6
D7
D9
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
F8
G5
G6
G7
G8
H5
H6
H7
H8
J5
J6
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
C4
C5
C8
C9
C10
D5
D8
E4
E9
F4
F9
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
B10
G3
G10
K8
K11
K12
L2
L3
L9
L12
M2
Confidential
3 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 2. Block Diagram
CK
CK
DLL
CLOCK
BUFFER
Row
Decoder
CKE
COMMAND
DECODER
COLUMN
COUNTER
A10/AP
MODE
REGISTER
Column Decoder
2048 x 256 x 32
CELL ARRAY
(BANK #1)
Column Decoder
ADDRESS
BUFFER
~
A0
Row
Decoder
A9
BA0
BA1
REFRESH
COUNTER
DQS0
DATA
STROBE
BUFFER
~
DQS3
CONTROL
SIGNAL
GENERATOR
Row
Decoder
CS
RAS
CAS
WE
2048 x 256 x 32
CELL ARRAY
(BANK #0)
DQ0
2048 x 256 x 32
CELL ARRAY
(BANK #2)
Column Decoder
DQ
Buffer
~
DM0
Row
Decoder
~
DQ31
2048 x 256 x 32
CELL ARRAY
(BANK #3)
Column Decoder
DM3
Confidential
4 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Ball Descriptions
Table 3. Ball Details
Symbol
Type
Description
CK, CK
Input
Differential Clock: CK and CK are differential clock inputs. All address and control input
signals are sampled on the crossing of the positive edge of CK and negative edge of CK .
Input and output data is referenced to the crossing of CK and CK (both directions of the
crossing)
CKE
Input
Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CK signal. If CKE goes
low synchronously with clock, the internal clock is suspended from the next clock cycle and
the state of output and burst address is frozen as long as the CKE remains low. When all
banks are in the idle state, deactivating the clock controls the entry to the Power Down and
Self Refresh modes.
BA0, BA1
Input
Bank Activate: BA0 and BA1 define to which bank the BankActivate, Read, Write, or
BankPrecharge command is being applied.
A0-A10
Input
Address Inputs: A0-A10 are sampled during the Bank Activate command (row address
A0-A10) and Read/Write command (column address A0-A7 with A10 defining Auto
Precharge) to select one location out of the 512K available in the respective bank. During a
Precharge command, A10 is sampled to determine if all banks are to be precharged (A10 =
HIGH). The address inputs also provide the op-code during a Mode Register Set or
Extended Mode Register Set command.
CS
Input
Chip Select: CS enables (sampled LOW) and disables (sampled HIGH) the command
decoder. All commands are masked when CS is sampled HIGH. CS provides for external
bank selection on systems with multiple banks. It is considered part of the command code.
RAS
Input
Row Address Strobe: The RAS signal defines the operation commands in conjunction
with the CAS and WE signals and is latched at the positive edges of CK. When RAS and
CS are asserted "LOW" and CAS is asserted "HIGH" either the BankActivate command or
the Precharge command is selected by the WE signal. When the WE is asserted "HIGH"
the BankActivate command is selected and the bank designated by BA is turned on to the
active state. When the WE is asserted "LOW" the Precharge command is selected and the
bank designated by BA is switched to the idle state after the precharge operation.
CAS
Input
Column Address Strobe: The CAS signal defines the operation commands in conjunction
with the RAS and WE signals and is latched at the positive edges of CK. When RAS is
held "HIGH" and CS is asserted "LOW" the column access is started by asserting CAS
"LOW". Then, the Read or Write command is selected by asserting WE "HIGH" or "LOW".
WE
Input
Write Enable: The WE signal defines the operation commands in conjunction with the
RAS and CAS signals and is latched at the positive edges of CK. The WE input is used
to select the BankActivate or Precharge command and Read or Write command.
DQS0-DQS3
Input /
Bidirectional Data Strobe: The DQSx signals are mapped to the following data bytes:
DQS0 to DQ0-DQ7, DQS1 to DQ8-DQ15, DQS2 to DQ16-DQ23, DQS3 to DQ24-DQ31.
Output
DM0 - DM3
Input
Data Input Mask: DM0-DM3 are byte specific. Input data is masked when DM is sampled
HIGH during a write cycle. DM3 masks DQ31-DQ24, DM2 masks DQ23-DQ16, DM1 masks
DQ15-DQ8, and DM0 masks DQ7-DQ0.
DQ0 - DQ31
Input /
Output
Data I/O: The DQ0-DQ31 input and output data are synchronized with positive and
negative edges of DQS0~DQS3. The I/Os are byte-maskable during Writes.
VDD
Supply
Power Supply: 2.5V ± 0.2V.
VSS
Supply
Ground
VDDQ
Supply
DQ Power: 2.5V ± 0.2V . Provide isolated power to DQs for improved noise immunity.
Confidential
5 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
VSSQ
Supply
DQ Ground: Provide isolated ground to DQs for improved noise immunity.
VREF
Supply
Reference Voltage for Inputs: +0.5*VDDQ
NC
-
Confidential
No Connect: These pins should be left unconnected.
6 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Operation Mode
Fully synchronous operations are performed to latch the commands at the positive edges of CK. Table 3 shows the
truth table for the operation commands.
Table 4. Truth Table (Note (1), (2))
Command
State
BankActivate
BankPrecharge
PrechargeAll
Write
Write and AutoPrecharge
Read
Read and Autoprecharge
Mode Register Set
Extended Mode Register Set
No-Operation
Device Deselect
Burst Stop
AutoRefresh
SelfRefresh Entry
Idle(3)
SelfRefresh Exit
Power Down Mode Entry
Any
Any
Active(3)
Active(3)
Active(3)
Active(3)
Idle
Idle
Any
Any
Active(4)
Idle
Idle
Idle
(Self Refresh)
Idle/Active(5)
CKEn-1 CKEn
DM BA1 BA0 A10
A9-0
H
H
H
H
H
H
H
H
H
H
H
H
H
H
X
X
X
X
X
X
X
X
X
X
X
X
H
L
X
X
X
V
V
X
X
X
X
X
X
X
X
X
V
V
X
V
V
V
V
L
L
X
X
X
X
X
V
V
X
V
V
V
V
L
H
X
X
X
X
X
Row Address
L
X
H
X
L
Column
H
Address
L
A0~A7
H
X
X
X
X
X
X
X
X
X
X
L
H
X
X
X
X
X
H
L
X
X
X
X
X
OP code
Any
L
H
X
X X
X
X
(Power Down)
Data Mask Enable
Active
H
X
H
X X
X
X
Data Mask Disable
Active
H
X
L
X X
X
X
Note: 1. V=Valid data, X=Don't Care, L=Low level, H=High level
2. CKEn signal is input level when commands are provided.
CKEn-1 signal is input level one clock cycle before the commands are provided.
3. These are states of bank designated by BA signal.
4. Device state is 2, 4, and 8 burst operation.
5. Power Down Mode can not enter in the burst operation.
Power Down Mode Exit
Confidential
7 of 63
CS
RAS
CAS
L
L
L
L
L
L
L
L
L
L
H
L
L
L
H
L
H
L
H
L
X
X
L
L
L
H
H
H
H
L
L
H
X
H
L
L
X
H
X
H
X
H
X
X
H
H
H
L
L
L
L
L
L
H
X
H
L
L
X
H
X
H
X
H
X
X
Rev.1.0 Dec 2015
WE
H
L
L
L
L
H
H
L
L
H
X
L
H
H
X
H
X
H
X
H
X
X
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Mode Register Set (MRS)
The Mode Register stores the data for controlling various operating modes of a DDR SDRAM. It programs CAS
Latency, Burst Type, and Burst Length to make the DDR SDRAM useful for a variety of applications. The default
value of the Mode Register is not defined; therefore the Mode Register must be written by the user. Values stored in
the register will be retained until the register is reprogrammed. The Mode Register is written by asserting Low on CS ,
RAS , CAS , WE , BA1 and BA0 (the device should have all banks idle with no bursts in progress prior to writing into
the mode register, and CKE should be High). The state of address pins A0~A10 and BA0, BA1 in the same cycle in
which CS , RAS , CAS and WE are asserted Low is written into the Mode Register. A minimum of two clock cycles,
tMRD, are required to complete the write operation in the Mode Register. The Mode Register is divided into various
fields depending on functionality. The Burst Length uses A0~A2, Burst Type uses A3, and CAS Latency (read latency
from column address) uses A4~A6. A logic 0 should be programmed to all the undefined addresses to ensure future
compatibility. Reserved states should not be used to avoid unknown device operation or incompatibility with future
versions. Refer to the table for specific codes for various burst lengths, burst types and CAS latencies.
Table 5. Mode Register Bitmap
BA1
BA0
0
0
A8
0
1
X
A10
A9
A8
RFU*
T.M.
A7
A6
A5
A4
CAS Latency
A7 Test Mode
0 Normal mode
0
DLL Reset
1
Test mode
A3
BT
A6 A5 A4 CAS Latency A3 Burst Type A2
Reserved
0 0 0
0 Sequential
0
Reserved
0 0 1
1 Interleave
0
2
0 1 0
0
0 1 1
3
0
BA0 Mode
1 0 0
Reserved
1
0
MRS
1 0 1
Reserved
1
1 EMRS
1 1 0
2.5
1
1 1 1
Reserved
1
* Note: RFU (Reserved for future use) must be set to “0” during MRS cycle.
A2
A1
A0
Burst Length
A1
0
0
1
1
0
0
1
1
Address Field
Mode Register
A0 Burst Length
0
Reserved
1
2
0
4
1
8
0
Reserved
1
Reserved
0
Reserved
1
Reserved
• Burst Length Field (A2~A0)
This field specifies the data length of column access using the A2~A0 pins and selects the Burst Length to be 2, 4, 8.
Table 6. Burst Length
A2
A1
A0
Burst Length
0
0
0
Reserved
0
0
1
2
0
1
0
4
0
1
1
8
1
0
0
Reserved
1
0
1
Reserved
1
1
0
Reserved
1
1
1
Reserved
Confidential
8 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
• Addressing Mode Select Field (A3)
The Addressing Mode can be one of two modes, either Interleave Mode or Sequential Mode. Both Sequential
Mode and Interleave Mode support burst length of 2, 4 and 8.
Table 7. Addressing Mode
A3
Addressing Mode
0
Sequential
1
Interleave
• Burst Definition, Addressing Sequence of Sequential and Interleave Mode
Table 8. Burst Address ordering
Burst Length
2
4
8
A2
X
X
X
X
X
X
0
0
0
0
1
1
1
1
Start Address
A1
X
X
0
0
1
1
0
0
1
1
0
0
1
1
A0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Sequential
Interleave
0, 1
1, 0
0, 1, 2, 3
1, 2, 3, 0
2, 3, 0, 1
3, 0, 1, 2
0, 1, 2, 3, 4, 5, 6, 7
1, 2, 3, 4, 5, 6, 7, 0
2, 3, 4, 5, 6, 7, 0, 1
3, 4, 5, 6, 7, 0, 1, 2
4, 5, 6, 7, 0, 1, 2, 3
5, 6, 7, 0, 1, 2, 3, 4
6, 7, 0, 1, 2, 3, 4, 5
7, 0, 1, 2, 3, 4, 5, 6
0, 1
1, 0
0, 1, 2, 3
1, 0, 3, 2
2, 3, 0, 1
3, 2, 1, 0
0, 1, 2, 3, 4, 5, 6, 7
1, 0, 3, 2, 5, 4, 7, 6
2, 3, 0, 1, 6, 7, 4, 5
3, 2, 1, 0, 7, 6, 5, 4
4, 5, 6, 7, 0, 1, 2, 3
5, 4, 7, 6, 1, 0, 3, 2
6, 7, 4, 5, 2, 3, 0, 1
7, 6, 5, 4, 3, 2, 1, 0
• CAS Latency Field (A6~A4)
This field specifies the number of clock cycles from the assertion of the Read command to the first read data. The
minimum whole value of CAS Latency depends on the frequency of CK. The minimum whole value satisfying the
following formula must be programmed into this field. tCAC(min) ≤ CAS Latency X tCK
Table 9. CAS Latency
A6
A5
A4
CAS Latency
0
0
0
Reserved
0
0
1
Reserved
0
1
0
2 clocks
0
1
1
3 clocks
1
0
0
Reserved
1
0
1
Reserved
1
1
0
2.5 clocks
1
1
1
Reserved
• Test Mode field (A8~A7)
These two bits are used to enter the test mode and must be programmed to "00" in normal operation.
Table 10. Test Mode
A8
A7
Test Mode
0
0
Normal mode
1
0
DLL Reset
• ( BA0, BA1)
Confidential
9 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Table 11. MRS/EMRS
BA1
BA0
A10 ~ A0
0
0
MRS Cycle
0
1
Extended Functions (EMRS)
Extended Mode Register Set (EMRS)
The Extended Mode Register Set stores the data for enabling or disabling DLL and selecting output driver
strength. The default value of the extended mode register is not defined, therefore must be written after power up for
proper operation. The Extended Mode Register is written by asserting Low on CS , RAS , CAS , WE , BA1 and BA0
(the device should have all banks idle with no bursts in progress prior to writing into the mode register, and CKE
should be High). The state of A0 ~ A10 and BA1 are written in the mode register in the same cycle as CS ,
RAS , CAS , and WE going low. The DDR SDRAM should be in all bank precharge with CKE already high prior to
writing into the extended mode register. A1 is used for setting driver strength. Two clock cycles are required to
complete the write operation in the extended mode register. The mode register contents can be changed using the
same command and clock cycle requirements during operation as long as all banks are in the idle state. A0 is used
for DLL enable or disable. "High" on BA0 is used for EMRS. Refer to the table for specific codes.
Table 12. Extended Mode Register Bitmap
BA1
BA0
0
1
A10
A9
A8
A7
A6
A5
A4
A3
A2
RFU must be set to “0”
A1
A0
DS
DLL Extended Mode Register
BA0
0
Mode
MRS
A1
0
Drive Strength
Full
A0
0
Enable
1
EMRS
1
RFU
1
Disable
Confidential
10 of 63
Address Field
DLL
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Table 13. Absolute Maximum Rating
Symbol
VI/O
Item
Voltage on I/O Pins Relative to Vss
Values
Unit
- 0.5 ~ VDDQ + 0.5
V
Voltage on VDD, VDDQ Supply Relative to Vss
- 1 ~ 3.6
V
VIN
Voltage on Inputs Relative to Vss
- 1 ~ 3.6
V
TA
Ambient Temperature
Commercial
0 ~ 70
°C
Industrial
- 40 ~ 85
°C
TSTG
Storage Temperature
- 55 ~ 150
°C
W
VDD, VDDQ
PD
Power Dissipation
1
Short
Circuit
Output
Current
IOS
50
mA
Note: Absolute maximum DC requirements contain stress ratings only. Functional operation at the absolute
maximum limits is not implied or guaranteed. Extended exposure to maximum ratings may affect device
reliability.
Table 14. Recommended D.C. Operating Conditions (VDD = 2.5V ± 0.2V, TA = -40~85 °C)
Symbol
Parameter
Min.
Max.
Unit
VDD
Power Supply Voltage
2.3
2.7
V
VDDQ
Power Supply Voltage (for I/O Buffer)
2.3
2.7
V
VREF
Input Reference Voltage
0.49*VDDQ
0.51* VDDQ
V
VIH (DC)
Input High Voltage (DC)
VREF + 0.15
VDDQ + 0.3
V
VIL (DC)
Input Low Voltage (DC)
-0.3
VREF – 0.15
V
VREF - 0.04
VREF + 0.04
V
VTT
Termination Voltage
VIN (DC)
Input Voltage Level, CK and CK inputs
-0.3
VDDQ + 0.3
V
VID (DC)
Input Different Voltage, CK and CK inputs
0.36
VDDQ + 0.6
V
Input leakage current
-2
2
µA
IOZ
Output leakage current
-5
5
µA
IOH
Output High Current (VOH = 1.95V)
-16.2
-
mA
16.2
-
mA
II
IOL
Output Low Current (VOL = 0.35V)
Note: All voltages are referenced to VSS.
Table 15. Capacitance (VDD = 2.5V, f = 1MHz, TA = 25 °C)
Symbol
Parameter
Min.
Max.
Delta
Unit
CIN1
Input Capacitance (CK, CK )
1.5
2.5
0.25
pF
CIN2
Input Capacitance (All other input-only pins)
1.5
2.5
0.5
pF
CI/O
DQ, DQS, DM Input/Output Capacitance
3.5
4.5
0.5
Note: These parameters are guaranteed by design, periodically sampled and are not 100% tested
Confidential
11 of 63
Rev.1.0 Dec 2015
pF
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Table 16. D.C. Characteristics (VDD = 2.5V ± 0.2V, TA = -40~85 °C)
Parameter & Test Condition
OPERATING CURRENT: One bank; Active-Precharge;
tRC=tRC(min); tCK=tCK(min); DQ,DM and DQS inputs
changing once per clock cycle; Address and control inputs
changing once every two clock cycles.
OPERATING CURRENT : One bank; Active-ReadPrecharge; BL=4; tRC=tRC(min); tCK=tCK(min); lout=0mA;
Address and control inputs changing once per clock cycle
PRECHARGE POWER-DOWN STANDBY CURRENT: All
banks idle; power-down mode; tCK=tCK(min); CKE=LOW
IDLE STANDBY CURRENT : CKE = HIGH;
CS =HIGH(DESELECT); All banks idle; tCK=tCK(min);
Address and control inputs changing once per clock cycle;
VIN=VREF for DQ, DQS and DM
ACTIVE POWER-DOWN STANDBY CURRENT : one bank
active; power-down mode; CKE=LOW; tCK=tCK(min)
ACTIVE STANDBY CURRENT : CS =HIGH;CKE=HIGH; one
bank active ; tRC=tRC(max);tCK=tCK(min);Address and control
inputs changing once per clock cycle; DQ,DQS,and DM
inputs changing twice per clock cycle
OPERATING CURRENT BURST READ : BL=2; READS;
Continuous burst; one bank active; Address and control
inputs changing once per clock cycle; tCK=tCK(min);
lout=0mA;50% of data changing on every transfer
OPERATING CURRENT BURST Write : BL=2; WRITES;
Continuous Burst ;one bank active; address and control
inputs changing once per clock cycle; tCK=tCK(min);
DQ,DQS,and DM changing twice per clock cycle; 50% of data
changing on every transfer
AUTO REFRESH CURRENT : tRC=tRFC(min); tCK=tCK(min)
SELF REFRESH CURRENT: Self Refresh Mode ; CKE≦
0.2V; tCK=tCK(min)
BURST OPERATING CURRENT 4 bank operation:
Four bank interleaving READs; BL=4;with Auto Precharge;
tRC=tRC(min); tCK=tCK(min); Address and control inputs
change only during Active, READ , or WRITE command
Confidential
12 of 63
Symbol
-5
Max.
Unit Note
IDD0
120
mA
IDD1
140
mA
IDD2P
15
mA
IDD2N
40
mA
IDD3P
40
mA
IDD3N
50
mA
IDD4R
150
mA
IDD4W
150
mA
IDD5
150
mA
IDD6
3
mA
IDD7
240
mA
Rev.1.0 Dec 2015
1
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Table 17. Electrical Characteristics and Recommended A.C.Operating Condition
(VDD = 2.5V ± 0.2V, TA = -40~85 °C)
Symbol
-5
Parameter
CL = 2
CL = 2.5
CL = 3
Min.
7.5
6
5
0.45
0.45
tCLMIN or tCHMIN
Max.
12
12
7.5
0.55
0.55
-
Unit Note
ns
ns
ns
tCK
tCK
ns
2
tCK
Clock cycle time
tCH
tCL
tHP
Clock high level width
Clock low level width
Clock half period
tHZ
Data-out-high impedance time from CK, CK
-
0.7
ns
3
tLZ
Data-out-low impedance time from CK, CK
-0.7
0.7
ns
3
tDQSCK
DQS-out access time from CK, CK
-0.6
0.6
ns
tAC
Output access time from CK, CK
-0.7
0.7
ns
0.9
0.4
0.72
0
0.25
0.4
0.35
0.35
0.7
0.7
0.4
0.4
tHP - tQHS
55
70
40
15
15
10
15
10
10
200
75
tWR+tRP
1.75
2.2
0.2
0.2
0.4
1.1
0.6
1.25
0.6
70K
15.6
0.5
-
ns
tCK
tCK
tCK
ns
tCK
tCK
tCK
tCK
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
tCK
ns
ns
ns
ns
ns
tDQSQ
DQS-DQ Skew
tRPRE
Read preamble
tRPST
Read postamble
tDQSS
CK to valid DQS-in
tWPRES DQS-in setup time
tWPRE
DQS Write preamble
tWPST
DQS write postamble
tDQSH
DQS in high level pulse width
tDQSL
DQS in low level pulse width
tIS
Address and Control input setup time
tIH
Address and Control input hold time
tDS
DQ & DM setup time to DQS
tDH
DQ & DM hold time to DQS
tQH
DQ/DQS output hold time from DQS
tRC
Row cycle time
tRFC
Refresh row cycle time
tRAS
Row active time
tRCD
Active to Read or Write delay
tRP
Row precharge time
tRRD
Row active to Row active delay
tWR
Write recovery time
tWTR
Internal Write to Read Command Delay
tMRD
Mode register set cycle time
tREFI
Average Periodic Refresh interval
tXSRD
Self refresh exit to read command delay
tXSNR
Self refresh exit to non-read command delay
tDAL
Auto Precharge write recovery + precharge time
tDIPW
DQ and DM input puls width
tIPW
Control and Address input pulse width
tQHS
Data Hold Skew Factor
tDSS
DQS falling edge to CK setup time
tDSH
DQS falling edge hold time from CK
Confidential
13 of 63
Rev.1.0 Dec 2015
4
5
6
6
7
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Table 18. Recommended A.C. Operating Conditions (VDD = 2.5V ± 0.2V, TA = -40~85 °C)
Symbol
Parameter
Min.
Max.
Unit
VIH (AC) Input High Voltage (AC)
VREF + 0.31
-
V
VIL (AC) Input Low Voltage (AC)
-
VREF – 0.31
V
0.7
VDDQ + 0.6
V
0.5*VDDQ-0.2
0.5*VDDQ+0.2
V
VID (AC) Input Different Voltage, CK and CK inputs
VIX (AC) Input Crossing Point Voltage, CK and CK inputs
Note:
1) Enables on-chip refresh and address counters.
2) Min(tCL, tCH) refers to the smaller of the actual clock low time and actual clock high time as provided to the device.
3) tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not
referenced to a specific voltage level, but specify when the device output is no longer driving (HZ), or begins
driving (LZ).
4) The specific requirement is that DQS be valid (High, Low, or at some point on a valid transition) on or before this
CLK edge. A valid transition is defined as monotonic, and meeting the input slew rate specifications of the device.
When no writes were previously in progress on the bus, DQS will be transitioning from High-Z to logic LOW. If a
previous write was in progress, DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time,
depending on tDQSS.
5) The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this
parameter, but system performance (bus turnaround) will degrade accordingly.
6) For command/address and CK & CK slew rate ≧ 1.0V/ns.
7) A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device.
8) Power-up sequence is described in Note 11
9) A.C. Test Conditions
Table 19. SSTL _2 Interface
Reference Level of Output Signals (VREF)
0.5 * VDDQ
Output Load
Reference to the Test Load
Input Signal Levels
VREF+0.31 V / VREF-0.31 V
Input Signals Slew Rate
1 V/ns
Reference Level of Input Signals
0.5 * VDDQ
Confidential
14 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
10) Figure 2 represents the timing reference load used in defining the relevant timing parameters of the part. It is not
intended to be either a precise representation of the typical system environment nor a depiction of the actual load
presented by a production tester. System designers use IBIS or other simulation tools to correlate the timing
reference load to a system environment is suggested.
Figure 3. SSTL_2 A.C. Test Load
0.5 * VDDQ
50Ω
DQ, DQS
Z0=50Ω
30pF
11) Power up Sequence
Power up must be performed in the following sequence.
1) Apply power to VDD before or at the same time as VDDQ, VTT and VREF when all input signals are held
"NOP" state and maintain CKE “LOW”.
2) Start clock and maintain stable condition for minimum 200µs.
3) Issue a “NOP” command and keep CKE “HIGH”
4) Issue a “Precharge All” command.
5) Issue EMRS – enable DLL.
6) Issue MRS – reset DLL. (An additional 200 clock cycles are required to lock the DLL).
7) Precharge all banks of the device.
8) Issue two or more Auto Refresh commands.
9) Issue MRS – with A8 to low to initialize the mode register.
Confidential
15 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Timing Waveforms
Figure 4. Activating a Specific Row in a Specific Bank
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
Address
RA
BA0,1
BA
RA=Row Address
BA=Bank Address
Don’t Care
Confidential
16 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 5. tRCD and tRRD Definition
CK
CK
COMMAND
ACT
Address
Row
Row
Col
BA0,BA1
Bank
A
Bank
B
Bank
B
NOP
NOP
ACT
tRRD
NOP
NOP
RD/WR
NOP
tRCD
Don’t Care
Figure 6. READ Command
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
A0 ~ A7
CA
EN AP
A10
DIS AP
BA0,1
BA
CA=Column Address
BA=Bank Address
EN AP=Enable Autoprecharge
DIS AP=Disable Autoprecharge
Don’t Care
Confidential
17 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 7. Read Burst Required CAS Latencies (CL=2)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
NOP
NOP
NOP
NOP
CL=2
DQS
DO
n
DQ
DO n=Data Out from column n
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order
following DO n
Don’t Care
Read Burst Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
NOP
NOP
NOP
NOP
CL=2.5
DQS
DO
n
DQ
DO n=Data Out from column n
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order following DO n
Don’t Care
Confidential
18 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Read Burst Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
NOP
NOP
NOP
NOP
CL=3
DQS
DO
n
DQ
DO n=Data Out from column n
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order
following DO n
Don’t Care
Confidential
19 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 8. Consecutive Read Bursts Required CAS Latencies (CL=2)
CK
CK
READ
COMMAND
NOP
NOP
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
READ
CL=2
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first)
3 subsequent elements of Data Out appear in the programmed order following DO n
3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o
Read commands shown must be to the same device
Don’t Care
Confidential
20 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Consecutive Read Bursts Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
READ
NOP
NOP
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
READ
CL=2.5
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first)
3 subsequent elements of Data Out appear in the programmed order following DO n
3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o
Read commands shown must be to the same device
Don’t Care
Confidential
21 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Consecutive Read Bursts Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
NOP
Bank,
Col n
ADDRESS
READ
NOP
NOP
NOP
Bank,
Col o
CL=3
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first)
3 subsequent elements of Data Out appear in the programmed order following DO n
3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o
Read commands shown must be to the same device
Don’t Care
Confidential
22 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 9. Non-Consecutive Read Bursts Required CAS Latencies (CL=2)
CK
CK
COMMAND
ADDRESS
READ
NOP
NOP
READ
NOP
NOP
Bank,
Col o
Bank,
Col n
CL=2
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order following DO n
(and following DO o)
Don’t Care
Non-Consecutive Read Bursts Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
READ
NOP
NOP
NOP
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
READ
CL=2.5
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order following DO n
(and following DO o)
Don’t Care
Confidential
23 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Non-Consecutive Read Bursts Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
NOP
NOP
NOP
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
READ
CL=3
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order following DO n
(and following DO o)
Don’t Care
Confidential
24 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 10. Random Read Accesses Required CAS Latencies (CL=2)
CK
CK
COMMAND
ADDRESS
READ
READ
READ
READ
Bank,
Col n
Bank,
Col o
Bank,
Col p
Bank,
Col q
NOP
NOP
CL=2
DQS
DO
n'
DO
n
DQ
DO
o'
DO
o
DO
p
DO
p'
DO
q
DO n, etc. =Data Out from column n, etc.
n', etc. =the next Data Out following DO n, etc. according to the programmed burst order
Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted
Reads are to active rows in any banks
Don’t Care
Random Read Accesses Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
ADDRESS
READ
READ
READ
READ
Bank,
Col n
Bank,
Col o
Bank,
Col p
Bank,
Col q
NOP
NOP
CL=2.5
DQS
DO
n
DQ
DO
n'
DO
o
DO
o'
DO
p
DO
p'
DO n, etc. =Data Out from column n, etc.
n', etc. =the next Data Out following DO n, etc. according to the programmed burst order
Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted
Reads are to active rows in any banks
Don’t Care
Confidential
25 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Random Read Accesses Required CAS Latencies (CL=3)
CK
CK
COMMAND
ADDRESS
READ
READ
READ
READ
Bank,
Col n
Bank,
Col o
Bank,
Col p
Bank,
Col q
NOP
NOP
CL=3
DQS
DO
n
DQ
DO
n'
DO
o
DO
o'
DO
p
DO n, etc. =Data Out from column n, etc.
n', etc. =the next Data Out following DO n, etc. according to the programmed burst order
Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted
Reads are to active rows in any banks
Don’t Care
Confidential
26 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 11. Terminating a Read Burst Required CAS Latencies (CL=2)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
BST
NOP
NOP
NOP
CL=2
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are bursts of 8 terminated after 4 data elements
3 subsequent elements of Data Out appear in the programmed order following DO n
Don’t Care
Terminating a Read Burst Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
BST
NOP
NOP
NOP
CL=2.5
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are bursts of 8 terminated after 4 data elements
3 subsequent elements of Data Out appear in the programmed order following DO n
Don’t Care
Confidential
27 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Terminating a Read Burst Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
BST
NOP
NOP
NOP
CL=3
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are bursts of 8 terminated after 4 data elements
3 subsequent elements of Data Out appear in the programmed order following DO n
Don’t Care
Confidential
28 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 12. Read to Write Required CAS Latencies (CL=2)
CK
CK
COMMAND
READ
BST
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
NOP
WRITE
tDQSS
min
CL=2
DQS
DO
n
DQ
DI
o
DM
DO n (or o)= Data Out from column n (or column o)
Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST
command shown can be NOP)
1 subsequent element of Data Out appears in the programmed order following DO n
Data in elements are applied following DI o in the programmed order
Don’t Care
Confidential
29 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Read to Write Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
READ
BST
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
NOP
WRITE
CL=2.5
tDQSS
min
DQS
DO
n
DQ
DI
o
DM
DO n (or o)= Data Out from column n (or column o)
Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST
command shown can be NOP)
1 subsequent element of Data Out appears in the programmed order following DO n
Data in elements are applied following DI o in the programmed order
Don’t Care
Confidential
30 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Read to Write Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
BST
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
NOP
WRITE
tDQSS
min
CL=3
DQS
DO
n
DQ
DI
o
DM
DO n (or o)= Data Out from column n (or column o)
Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST
command shown can be NOP)
1 subsequent element of Data Out appears in the programmed order following DO n
Data in elements are applied following DI o in the programmed order
Don’t Care
Confidential
31 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 13. Read to Precharge Required CAS Latencies (CL=2)
CK
CK
COMMAND
READ
NOP
PRE
NOP
NOP
ACT
tRP
Bank A,
Col n
ADDRESS
Bank
(a or all)
Bank A,
Row
CL=2
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8
3 subsequent elements of Data Out appear in the programmed order
following DO n
Precharge may be applied at (BL/2) tCK after the READ command
Note that Precharge may not be issued before tRAS ns after the ACTIVE
command for applicable banks
The Active command may be applied if tRC has been met
Don’t Care
Confidential
32 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Read to Precharge Required CAS Latencies (CL=2.5)
CK
CK
COMMAND
READ
NOP
PRE
NOP
NOP
ACT
tRP
Bank A,
Col n
ADDRESS
Bank
(a or all)
Bank A,
Row
CL=2.5
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8
3 subsequent elements of Data Out appear in the programmed order
following DO n
Precharge may be applied at (BL/2) tCK after the READ command
Note that Precharge may not be issued before tRAS ns after the ACTIVE
command for applicable banks
The Active command may be applied if tRC has been met
Don’t Care
Confidential
33 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Read to Precharge Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
NOP
PRE
NOP
NOP
ACT
tRP
Bank A,
Col n
ADDRESS
Bank
(a or all)
Bank A,
Row
CL=3
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8
3 subsequent elements of Data Out appear in the programmed order
following DO n
Precharge may be applied at (BL/2) tCK after the READ command
Note that Precharge may not be issued before tRAS ns after the ACTIVE
command for applicable banks
The Active command may be applied if tRC has been met
Confidential
34 of 63
Don’t Care
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 14. Write Command
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
A0 ~ A7
CA
EN AP
A10
DIS AP
BA0,1
BA
CA=Column Address
BA=Bank Address
EN AP=Enable Autoprecharge
DIS AP=Disable Autoprecharge
Don’t Care
Confidential
35 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 15. Write Max DQSS
T0
CK
T1
T2
T3
T4
T5
T6
T7
CK
COMMAND
WRITE
ADDRESS
Bank A,
Col n
NOP
NOP
NOP
tDQSS
max
DQS
DI
n
DQ
DM
DI n = Data In for column n
3 subsequent elements of Data In are applied in the programmed
order following DI n
A non-interrupted burst of 4 is shown
A10 is LOW with the WRITE command (AUTO PRECHARGE
disabled)
Don’t Care
Confidential
36 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 16. Write Min DQSS
T0
CK
T1
T2
T3
T4
T5
T6
CK
COMMAND
NOP
WRITE
NOP
NOP
Bank A,
Col n
tDQSS
min
ADDRESS
DQS
DI
n
DQ
DM
DI n = Data In for column n
3 subsequent elements of Data In are applied in the programmed
order following DI n
A non-interrupted burst of 4 is shown
A10 is LOW with the WRITE command (AUTO PRECHARGE
disabled)
Don’t Care
Confidential
37 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 17. Write Burst Nom, Min, and Max tDQSS
T0
CK
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
COMMAND
NOP
WRITE
NOP
NOP
NOP
NOP
Bank ,
Col n
ADDRESS
tDQSS (nom)
DQS
DI
n
DQ
DM
tDQSS (min)
DQS
DI
n
DQ
DM
tDQSS (max)
DQS
DI
n
DQ
DM
DI n = Data In for column n
3 subsequent elements of Data are applied in the programmed order following DI n
A non-interrupted burst of 4 is shown
A10 is LOW with the WRITE command (AUTO PRECHARGE disabled)
DM=DM0 ~ DM3
Don’t Care
Confidential
38 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 18. Write to Write Max tDQSS
T0
CK
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
COMMAND
WRITE
NOP
NOP
NOP
NOP
Bank ,
Col o
Bank ,
Col n
ADDRESS
WRITE
tDQSS (max)
DQS
DI
n
DQ
DI
o
DM
DI n , etc. = Data In for column n,etc.
3 subsequent elements of Data In are applied in the programmed order following DI n
3 subsequent elements of Data In are applied in the programmed order following DI o
Non-interrupted bursts of 4 are shown
DM= DM0 ~ DM3
Don’t Care
Confidential
39 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 19. Write to Write Max tDQSS, Non Consecutive
T0
CK
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
COMMAND
WRITE
NOP
NOP
Bank
Col n
ADDRESS
WRITE
NOP
NOP
Bank
Col o
tDQSS (max)
DQS
DI
n
DQ
DI
o
DM
DI n, etc. = Data In for column n, etc.
3 subsequent elements of Data In are applied in the programmed order following DI n
3 subsequent elements of Data In are applied in the programmed order following DI o
Non-interrupted bursts of 4 are shown
DM= DM0 ~ DM3
Don’t Care
Confidential
40 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 20. Random Write Cycles Max tDQSS
T0
CK
T1
T2
T4
T3
T5
T6
T8
T7
T9
CK
COMMAND
ADDRESS
WRITE
WRITE
WRITE
WRITE
WRITE
Bank
Col n
Bank
Col o
Bank
Col p
Bank
Col q
Bank
Col r
tDQSS (max)
DQS
DI
n
DQ
DI
n'
DI
o
DI
o'
DI
p
DI
p'
DI
q
DI
q'
DM
DI n, etc. = Data In for column n, etc.
n', etc. = the next Data In following DI n, etc. according to the programmed burst order
Programmed Burst Length 2, 4, or 8 in cases shown
If burst of 4 or 8, the burst would be truncated
Each WRITE command may be to any bank and may be to the same or different devices
DM= DM0 ~ DM3
Don’t Care
Confidential
41 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 21. Write to Read Max tDQSS Non Interrupting
T0
CK
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
CK
COMMAND
WRITE
NOP
NOP
NOP
READ
NOP
NOP
tWTR
Bank
Col o
Bank
Col n
ADDRESS
CL=3
tDQSS (max)
DQS
DI
n
DQ
DM
DI n, etc. = Data In for column n, etc.
1 subsequent elements of Data In are applied in the programmed order following DI n
A non-interrupted burst of 2 is shown
tWTR is referenced from the first positive CK edge after the last Data In Pair
A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
The READ and WRITE commands are to the same devices but not necessarily to the same bank
DM= DM0 ~ DM3
Confidential
Don’t Care
42 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 22. Write to Read Max tDQSS Interrupting
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
READ
NOP
tWTR
Bank
Col o
Bank
Col n
ADDRESS
CL=3
tDQSS (max)
DQS
DI
n
DQ
DM
DI n, etc. = Data In for column n, etc.
1 subsequent elements of Data In are applied in the programmed order following DI n
An interrupted burst of 8 is shown, 2 data elements are written
tWTR is referenced from the first positive CK edge after the last Data In Pair
A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
The READ and WRITE commands are to the same devices but not necessarily to the same bank
DM= DM0 ~ DM3
Don’t Care
Confidential
43 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 23. Write to Read Max tDQSS, ODD Number of Data, Interrupting
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
READ
NOP
tWTR
Bank
Col o
Bank
Col n
ADDRESS
CL=3
tDQSS (max)
DQS
DI
n
DQ
DM
DI n = Data In for column n
An interrupted burst of 8 is shown, 1 data elements are written
tWTR is referenced from the first positive CK edge after the last Data In Pair (not the last desired
Data In element)
A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
The READ and WRITE commands are to the same devices but not necessarily to the same bank
DM= DM0 ~ DM3
Don’t Care
Confidential
44 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 24. Write to Precharge Max tDQSS, NON- Interrupting
T0
CK
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
COMMAND
WRITE
ADDRESS
Bank a,
Col n
NOP
NOP
NOP
NOP
PRE
tWR
Bank
(a or al)
tRP
tDQSS (max)
DQS
DI
n
DQ
DM
DI n = Data In for column n
1 subsequent elements of Data In are applied in the programmed order following DI n
A non-interrupted burst of 2 is shown
tWR is referenced from the first positive CK edge after the last Data In Pair
A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
DM= DM0 ~ DM3
Don’t Care
Confidential
45 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 25. Write to Precharge Max tDQSS, Interrupting
T0
CK
T1
T2
T3
T4
T5
T6
T8
T7
T9
T10
T11
CK
COMMAND
WRITE
NOP
NOP
NOP
PRE
NOP
tWR
Bank a,
Col n
ADDRESS
Bank
(a or all)
tDQSS (max)
tRP
*2
DQS
DI
n
DQ
DM
*1
*1
*1
*1
DI n = Data In for column n
An interrupted burst of 4 or 8 is shown, 2 data elements are written
tWR is referenced from the first positive CK edge after the last Data In Pair
A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
*1 = can be don't care for programmed burst length of 4
*2 = for programmed burst length of 4, DQS becomes don't care at this point
DM= DM0 ~ DM3
Don’t Care
Confidential
46 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 26. Write to Precharge Max tDQSS ODD Number of Data Interrupting
T0
CK
T1
T2
T3
T4
T5
T6
T8
T7
T9
T10
T11
CK
COMMAND
WRITE
NOP
NOP
NOP
NOP
PRE
tWR
Bank a,
Col n
ADDRESS
Bank
(a or all)
tDQSS (max)
tRP
*2
DQS
DI
n
DQ
DM
*1
*1
*1
*1
DI n = Data In for column n
An interrupted burst of 4 or 8 is shown, 1 data element is written
tWR is referenced from the first positive CK edge after the last Data In Pair
A10 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
*1 = can be don't care for programmed burst length of 4
*2 = for programmed burst length of 4, DQS becomes don't care at this point
DM= DM0 ~ DM3
Don’t Care
Confidential
47 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 27. Precharge Command
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
A0-A9
ALL BANKS
A10
ONE BANK
BA
BA0,1
BA= Bank Address (if A10 is
LOW, otherwise don't care)
Don’t Care
Confidential
48 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 28. Power-Down
T0
T1
T2
T4
T3
Tn
Tn+3 Tn+4 Tn+5 Tn+6
Tn+1 Tn+2
CK
CK
tIS
tIS
CKE
COMMAND
NOP
NOP
VALID
Exit power-down
mode
Enter power-down
mode
No column access
in progress
VALID
Don’t Care
Figure 29. Clock Frequency Change in Precharge
T0
T1
T2
T4
Tx
Tx+1
Ty
Ty+1
Ty+2
Ty+3
Ty+4
Tz
CK
CK
CMD
CKE
NOP
NOP
NOP
Frequency Change
Occurs here
DLL
RESET
NOP
NOP
tIS
tRP
Minmum 2 clocks
Required before
Changing frequency
Confidential
Stable new clock
Before power down exit
49 of 63
200 Clocks
Rev.1.0 Dec 2015
Valid
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 30. Data input (Write) Timing
tDQSH
tDQSL
DQS
tDS
DQ
tDH
tDS
DI
n
DM
tDH
DI n = Data In for column n
Burst Length = 4 in the case shown
3 subsequent elements of Data In are applied in the programmed order
following DI n
Don’t Care
Figure 31. Data Output (Read) Timing
tCH
tCL
CK
CK
DQS
DQ
tDQSQ
max
tDQSQ
tQH
max
tQH
Burst Length = 4 in the case shown
Confidential
50 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 32. Initialize and Mode Register Sets
VDD
VDDQ
tVDT>=0
VTT
(system*)
tCK
tCH tCL
VREF
CK
CK
tIS tIH
CKE
LVCMOS LOW LEVEL
tIS tIH
NOP
COMMAND
PRE
MRS
EMRS
PRE
AR
AR
MRS
ACT
CODE
RA
CODE
RA
BA0=L
BA1=L
BA
DM
tIS tIH
CODE
A0-A9
ALL BANKS
A10
tIS tIH
CODE
tIS tIH
ALL BANKS
CODE
CODE
tIS tIH
tIS tIH
BA0=H
BA1=L
BA0,BA1
BA0=L
BA1=L
High-Z
DQS
High-Z
DQ
T=200µs
**tMRD
**tMRD
Extended mode
Register set
Power-up:
VDD and
CLK stable
tRFC
tRP
tRFC
**tMRD
200 cycles of CK**
Load Mode
Register,
Reset DLL (with A8=H)
Load Mode
Register,
(with A8=L)
*=VTT is not applied directly to the device, however tVTD must be greater than or equal to zero to avoid device latch-up.
** = tMRD is required before any command can be applied, and 200 cycles of CK are required before any executable
command can be applied the two auto Refresh commands may be moved to follow the first MRS but precede the second
PRECHARGE ALL command.
Don’t Care
Confidential
51 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 33. Power Down Mode
tCK
tCH
tCL
CK
CK
tIS tIH
CKE
tIS
tIS
tIS tIH
COMMAND
VALID*
NOP
NOP
VALID
tIS tIH
VALID
ADDR
VALID
DQS
DQ
DM
Enter
power-down mode
Exit
power-down mode
No column accesses are allowed to be in progress at the time Power-Down is entered
*=If this command is a PRECHARGE ALL (or if the device is already in the idle state) then the Power-Down
mode shown is Precharge Power Down. If this command is an ACTIVE (or if at least one row is already active)
then the Power-Down mode shown is active Power Down.
Don’t Care
Confidential
52 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 34. Auto Refresh Mode
tCK
tCH tCL
CK
CK
tIS tIH
CKE
VALID
VALID
tIS tIH
COMMAND
NOP
PRE
NOP
NOP
AR
NOP
AR
NOP
NOP
ACT
RA
A0-A9
ALL BANKS
RA
A10
ONE BANKS
tIS tIH
BA0,BA1
BA
*Bank(s)
DQS
DQ
DM
tRP
tRFC
tRFC
* = Don't Care , if A10 is HIGH at this point; A10 must be HIGH if more than one bank is active (i.e., must precharge all active banks)
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH
NOP commands are shown for ease of illustration; other valid commands may be possible after tRFC
DM, DQ and DQS signals are all
Don't Care
/High-Z for operations shown
Don’t Care
Confidential
53 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 35. Self Refresh Mode
tCK
tCH
CK
Clock must be stable before
Exiting Self Refresh mode
tCL
CK
tIS tIH
CKE
tIS
tIS
tIS tIH
COMMAND
NOP
NOP
AR
VALID
tIS tIH
VALID
ADDR
DQS
DQ
DM
tRP*
Enter Self Refresh
mode
tXSNR/
tXSRD**
Exit Self Refresh
mode
* = Device must be in the All banks idle state prior to entering Self Refresh mode
** = tXSNR is required before any non-READ command can be applied, and tXSRD (200 cycles of CK) is
required before a READ command can be applied.
Don’t Care
Confidential
54 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 36. Read without Auto Precharge
tCK
tCH tCL
CK
CK
tIH
tIS tIH
CKE
VALID
VALID
VALID
NOP
NOP
NOP
tIS tIH
NOP
COMMAND
READ
PRE
NOP
NOP
NOP
ACT
tIS tIH
Col n
A0-A9
tIS
RA
tIH
ALL BANKS
RA
A10
ONE BANKS
DIS AP
tIS tIH
Bank X
BA0,BA1
Bank X
*Bank X
CL=3
tRP
DM
Case 1:
tAC/tDQSCK=min
tDQSCK
min
tRPRE
tRPST
DQS
tLZ
min
DQ
DO
n
tLZ
tAC
min
Case 2:
tAC/tDQSCK=max
min
tDQSCK
max
tRPRE
tRPST
DQS
tLZ
max
DQ
tLZ
max
tHZ
max
DO
n
tAC
max
DO n = Data Out from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DO n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A10 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH
NOP commands are shown for ease of illustration; other commands may be valid at these times
Don’t Care
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Confidential
55 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 37. Read with Auto Precharge
tCK
tCH tCL
CK
CK
tIH
tIS tIH
CKE
VALID
VALID
VALID
NOP
NOP
NOP
tIS tIH
NOP
COMMAND
READ
NOP
NOP
NOP
NOP
ACT
tIS tIH
Col n
A0-A9
RA
EN AP
RA
A10
tIS tIH
tIS tIH
Bank X
BA0,BA1
Bank X
CL=3
tRP
DM
Case 1:
tAC/tDQSCK=min
tDQSCK
min
tRPRE
DQS
tRPST
tLZ
min
DO
n
DQ
tLZ
tAC
min
min
Case 2:
tAC/tDQSCK=max
tDQSCK
max
tRPRE
tRPST
DQS
tLZ
max
DQ
tHZ
max
DO
n
tLZ
max
tAC
max
DO n = Data Out from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DO n
EN AP = Enable Autoprecharge
ACT = ACTIVE, RA = Row Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
The READ command may not be issued until tRAP has been satisfied. Support Fast Autoprecharge , tRAP = tRCD, But it still needs tRC to
next ACT.
Don’t Care
Confidential
56 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 38. Bank Read Access
tCK
tCH tCL
CK
CK
tIS tIH
CKE
tIS tIH
NOP
COMMAND
ACT
NOP
NOP
NOP
READ
NOP
PRE
NOP
NOP
ACT
tIS tIH
A0-A9
Col n
RA
tIS
A10
RA
tIH
ALL BANKS
RA
RA
tIS tIH
Bank X
BA0,BA1
DIS AP
ONE BANKS
Bank X
*Bank X
Bank X
tRC
tRAS
tRCD
tRP
CL=3
DM
Case 1:
tAC/tDQSCK=min
tDQSCK
min
tRPRE
DQS
tLZ
DO
n
min
DQ
tLZ
tAC
tDQSCK
min
Case 2:
tAC/tDQSCK=max
min
max
tRPRE
DQS
max
DO
n
tLZ
max
DO n = Data Out from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DO n
tRPST
tHZ
tLZ
max
DQ
tRPST
tAC
max
DIS AP = Disable Autoprecharge
*=
Don't Care , if A10 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Note that tRCD > tRCD MIN so that the same timing applies if Autoprecharge is enabled (in which case tRAS
would be limiting)
Confidential
57 of 63
Rev.1.0 Dec 2015
Don’t Care
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 39. Write without Auto Precharge
tCK
tCH tCL
CK
CK
tIH
tIS tIH
CKE
VALID
tIS tIH
NOP
COMMAND
NOP
NOP
NOP
WRITE
NOP
PRE
NOP
NOP
ACT
tIS tIH
RA
Col n
A0-A9
tIS tIH
ALL BANKS
RA
A10
ONE BANKS
DIS AP
tIS tIH
Bank X
BA0,BA1
Case 1:
tDQSS=min
tDQSS
BA
*Bank X
tDSH
tDQSH
tRP
tDSH
tWR
tWPST
DQS
tDQSL
tWPRES
tWPRE
DI
n
DQ
DM
tDSS
Case 2:
tDQSS=max
tDQSS
tDSS
tDQSH
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data In are provided in the programmed order following DI n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A10 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the +
25% window of the corresponding positive clock edge
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Confidential
58 of 63
Don’t Care
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 40. Write with Auto Precharge
tCK
tCH tCL
CK
CK
tIS tIH
CKE
VALID
VALID
VALID
NOP
NOP
NOP
tIS tIH
COMMAND
NOP
NOP
NOP
NOP
WRITE
NOP
ACT
tIS tIH
RA
Col n
A0-A9
DIS AP
RA
A10
tIS tIH
Bank X
BA0,BA1
BA
tDAL
Case 1:
tDQSS=min
tDQSS
tDSH
tDQSH
tDSH
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
Case 2:
tDQSS=max
tDQSS
tDSS
tDQSH
tDSS
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DI n
EN AP = Enable Autoprecharge
ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25%
window of the corresponding positive clock edge
Don’t Care
Confidential
59 of 63
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 41. Bank Write Access
tCK
tCH tCL
CK
CK
tIS tIH
CKE
tIS tIH
NOP
COMMAND
ACT
NOP
NOP
WRITE
NOP
NOP
NOP
NOP
PRE
tIS tIH
RA
A0-A9
Col n
tIS tIH
ALL BANKS
DIS AP
ONE BANK
RA
A10
tIS tIH
Bank X
BA0,BA1
Bank X
*Bank X
tRAS
tRCD
Case 1:
tDQSS=min
tWR
tDQSS
tDSH
tDQSH
tDSH
tWPST
DQS
tWPRES
tWPRE
tDQSL
DI
n
DQ
DM
tDSS
Case 2:
tDQSS=max
tDQSS
tDSS
tDQSH
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DI n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A10 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25%
window of the corresponding positive clock edge
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Confidential
60 of 63
Don’t Care
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 42. Write DM Operation
tCK
tCH tCL
CK
CK
tIS tIH
CKE
VALID
tIS tIH
NOP
COMMAND
NOP
NOP
NOP
WRITE
NOP
PRE
NOP
NOP
ACT
tIS tIH
RA
Col n
A0-A9
tIS
tIH
ALL BANKS
RA
A10
ONE BANKS
DIS AP
tIS tIH
Bank X
BA0,BA1
Case 1:
tDQSS=min
tDQSS
BA
*Bank X
tDSH
tDQSH
tRP
tDSH
tWR
tWPST
DQS
tDQSL
tWPRES
tWPRE
DI
n
DQ
DM
tDSS
Case 2:
tDQSS=max
tDQSS
tDSS
tDQSH
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data In are provided in the programmed order following DI n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A10 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25%
window of the corresponding positive clock edge
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Confidential
61 of 63
Don’t Care
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
Figure 43. 144 ball LFBGA Package Outline Drawing Information
Units: mm
PIN #1
Top View
"A"
Bottom View
Side View
DETAIL : "A"
Symbol
A
A1
A2
D
E
D1
E1
e
b
Confidential
Dimension in inch
Min
Nom
Max
--0.055
0.012
0.014
0.016
0.036
0.038
0.040
0.469
0.472
0.476
0.469
0.472
0.476
-0.346
--0.346
--0.031
-0.016
0.018
0.020
62 of 63
Dimension in mm
Min
Nom
Max
--1.40
0.30
0.35
0.40
0.91
0.96
1.01
11.90
12.00
12.10
11.90
12.00
12.10
-8.80
--8.80
--0.80
-0.40
0.45
0.50
Rev.1.0 Dec 2015
AS4C2M32D1A-5BCN
AS4C2M32D1A-5BIN
PART NUMBERING SYSTEM
AS4C
DRAM
2M32D1A
2M32=2Mx32
D1=DDR
A = Die Revision
5
5=200MHz
B
B = FBGA
C/I
N
C=Commercial
(0° C70° C)
I =Industrial
(-40° C85° C)
Indicates Pb and
Halogen Free
Alliance Memory, Inc.
511 Taylor Way,
San Carlos, CA 94070
Tel: 650-610-6800
Fax: 650-620-9211
www.alliancememory.com
Copyright © Alliance Memory
All Rights Reserved
© Copyright 2007 Alliance Memory, Inc. All rights reserved. Our three-point logo, our name and Intelliwatt are
trademarks or registered trademarks of Alliance. All other brand and product names may be the trademarks of their
respective companies. Alliance reserves the right to make changes to this document and its products at any time
without notice. Alliance assumes no responsibility for any errors that may appear in this document. The data
contained herein represents Alliance's best data and/or estimates at the time of issuance. Alliance reserves the right
to change or correct this data at any time, without notice. If the product described herein is under development,
significant changes to these specifications are possible. The information in this product data sheet is intended to be
general descriptive information for potential customers and users, and is not intended to operate as, or provide, any
guarantee or warrantee to any user or customer. Alliance does not assume any responsibility or liability arising out of
the application or use of any product described herein, and disclaims any express or implied warranties related to the
sale and/or use of Alliance products including liability or warranties related to fitness for a particular purpose,
merchantability, or infringement of any intellectual property rights, except as express agreed to in Alliance's Terms
and Conditions of Sale (which are available from Alliance). All sales of Alliance products are made exclusively
according to Alliance's Terms and Conditions of Sale. The purchase of products from Alliance does not convey a
license under any patent rights, copyrights; mask works rights, trademarks, or any other intellectual property rights of
Alliance or third parties. Alliance does not authorize its products for use as critical components in life-supporting
systems where a malfunction or failure may reasonably be expected to result in significant injury to the user, and the
inclusion of Alliance products in such life-supporting systems implies that the manufacturer assumes all risk of such
use and agrees to indemnify Alliance against all claims arising from such use.
Confidential
63 of 63
Rev.1.0 Dec 2015