0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
160NH00GL

160NH00GL

  • 厂商:

    ALTECH

  • 封装:

    插件

  • 描述:

    FUSENH00GL160A500V ETI ART.: 004

  • 数据手册
  • 价格&库存
160NH00GL 数据手册
NH KNIFE BLADE NH fuses are typically used for power distribution applications and to protect large electrical devices such as motors, drives, etc. They are available in seven sizes with a current range of 2 to 1600 Amps. NH fuses have knife blades at both ends, which mount into Fuse Bases. Fuse Bases are available in one or three pole designs and can be panel or DIN rail mounted. Please refer to pg 19 for NH Fuse Accessories. NH00 (NHC00)3 Current/ Voltage Ordering Information 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Operating Class aM (VDE 0636 / IEC 269) Motor Protection up to 660V AC 2/660V AC 4/660V AC 6/660V AC 10/660V AC 16/660V AC 20/660V AC 25/660V AC 32/660V AC 35/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/500V AC 160/500V AC 2NH00AM-6 4NH00AM-6 6NH00AM-6 10NH00AM-6 16NH00AM-6 20NH00AM-6 25NH00AM-6 32NH00AM-6 35NH00AM-6 40NH00AM-6 50NH00AM-6 63NH00AM-6 80NH00AM-6 100NH00AM-6 125NH00AM 160NH00AM A A A A A A A A A A A A A A A A 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Super Fast Blow Operating Class aR / gR (VDE 0636 / IEC 269) Semiconductor Protection up to 660V AC (1000V available) 16/660V AC 20/660V AC 25/660V AC 32/660V AC 35/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/660V AC 160/660V AC 16NH00GR-6 20NH00GR-6 25NH00GR-6 32NH00GR-6 35NH00GR-6 40NH00GR-6 50NH00GR-6 63NH00GR-6 80NH00GR-6 100NH00GR-6 125NH00GR-6 160NH00AR-6 A A A A A A A A A A A A 3 3 3 3 3 3 3 3 3 3 3 3 Typical Marking: gL/gG aR - Semiconductor Protection Partial range, short circuit protection for devices such as diodes, SCRs, etc. NH00 Fuses Operating Class gL / gG are available in 660V, and with insulated tags. Typical Markings: Ultra Rapid™, Sitor™, Silcu™, Protistor™, Recticur™, Ultra QuickTM, aR, gR - Semiconductor Protection Full range overload and short circuit protection for devices such as diodes, SCRs, etc. Typical Markings: Ultra Rapid™, Sitor™, Silcu™, Protistor™, Recticur™, Ultra QuickTM , gR, Mostly red, orange or blue imprint. Std. Pk. A A A A A A A A A A A A A A A A gL/gG - Line Protection Slow, typically used for distribution circuits or resistive loads. Typical Marking: aM Green imprint. Dim. 2NH00GL 4NH00GL 6NH00GL 10NH00GL 16NH00GL 20NH00GL 25NH00GL 32NH00GL 35NH00GL 40NH00GL 50NH00GL 63NH00GL 80NH00GL 100NH00GL 125NH00GL 160NH00GL Operating Classes aM - Motor Protection Fast acting short circuit protection, but slow acting overload protection. Cat. No. 2/500V AC 4/500V AC 6/500V AC 10/500V AC 16/500V AC 20/500V AC 25/500V AC 32/500V AC 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC Operating Class gL / gG (VDE 0636 / IEC 269) Line Protection up to 500V AC (660V available) 1 1 1 1 1 1 1 1 1 1 1 F L2 1 Also available in Operating Class aR. 2 Also available in 1000V. Designate suffix “-1” (ex. 32NH0GR-1). 3 Size NHC00 will be supplied in place of NH00 at manufacturer discretion. 4 Knife blade is available with screw holes, please designate a “B” after the size, (ex. 250NH3BAR-6). 11.5 C T L1 16 W Altech Corp.® ● 35 Royal Road Flemington NJ 08822-6000 ● Phone (908) 806-9400 ● Fax (908) 806-9490 ● www.altechcorp.com D NH0 Current/ Voltage NH1 Current/ Voltage Cat. No. Dim. 10/500V AC 16/500V AC 20/500V AC 25/500V AC 32/500V AC 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC 200/500V AC 10NH0GL 16NH0GL 20NH0GL 25NH0GL 32NH0GL 35NH0GL 40NH0GL 50NH0GL 63NH0GL 80NH0GL 100NH0GL 125NH0GL 160NH0GL 200NH0GL B B B B B B B B B B B B B B 3 3 3 3 3 3 3 3 3 3 3 3 3 3 16/500V AC 20/500V AC 25/500V AC 32/500V AC 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC 200/500V AC 224/500V AC 250/500V AC 10/500V AC 16/500V AC 20/500V AC 25/500V AC 32/500V AC 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC 10NH0AM 16NH0AM 20NH0AM 25NH0AM 32NH0AM 35NH0AM 40NH0AM 50NH0AM 63NH0AM 80NH0AM 100NH0AM 125NH0AM 160NH0AM B B B B B B B B B B B B B 3 3 3 3 3 3 3 3 3 3 3 3 3 16/660V AC 20/660V AC 25/660V AC 32/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/660V AC 160/660V AC 16NH0GR-6 20NH0GR-6 25NH0GR-6 32NH0GR-6 40NH0GR-6 50NH0GR-6 63NH0GR-6 80NH0GR-6 100NH0GR-6 125NH0GR-6 160NH0AR-6 B B B B B B B B B B B 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 Std. Pk. Cat. No. NH2 Current/ Voltage Dim. Std. Pk. Dim. Std. Pk. 16NH1GL 20NH1GL 25NH1GL 32NH1GL 35NH1GL 40NH1GL 50NH1GL 63NH1GL 80NH1GL 100NH1GL 125NH1GL 160NH1GL 200NH1GL 224NH1GL 250NH1GL C C C C C C C C C C C C D D D 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC 200/500V AC 224/500V AC 250/500V AC 300/500V AC 315/500V AC 355/500V AC 400/500V AC 425/500V AC 35NH2GL 40NH2GL 50NH2GL 63NH2GL 80NH2GL 100NH2GL 125NH2GL 160NH2GL 200NH2GL 224NH2GL 250NH2GL 300NH2GL 315NH2GL 355NH2GL 400NH2GL 425NH2GL Cat. No. E E E E E E E E E E E E F F F F 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 16/500V AC 20/500V AC 25/500V AC 32/500V AC 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC 200/500V AC 224/500V AC 250/500V AC 16NH1AM 20NH1AM 25NH1AM 32NH1AM 35NH1AM 40NH1AM 50NH1AM 63NH1AM 80NH1AM 100NH1AM 125NH1AM 160NH1AM 200NH1AM 224NH1AM 250NH1AM C C C C C C C C C C C C D D D 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 35/500V AC 40/500V AC 50/500V AC 63/500V AC 80/500V AC 100/500V AC 125/500V AC 160/500V AC 200/500V AC 224/500V AC 250/500V AC 315/500V AC 355/500V AC 400/500V AC 35NH2AM 40NH2AM 50NH2AM 63NH2AM 80NH2AM 100NH2AM 125NH2AM 160NH2AM 200NH2AM 224NH2AM 250NH2AM 315NH2AM 355NH2AM 400NH2AM E E E E E E E E E E E F F F 3 3 3 3 3 3 3 3 3 3 3 3 3 3 16/660V AC 20/660V AC 25/660V AC 2 32/660V AC 2 35/660V AC 2 40/660V AC 2 50/660V AC 2 63/660V AC 2 80/660V AC 2 100/660V AC2 125/660V AC2 160/660V AC2 200/660V AC2 224/660V AC2 250/660V AC2 315/500V AC 16NH1GR-6 20NH1GR-6 25NH1GR-6 4 32NH1GR-6 4 35NH1GR-6 4 40NH1GR-6 4 50NH1GR-6 4 63NH1GR-6 4 80NH1GR-6 4 100NH1GR-6 4 125NH1GR-6 4 160NH1AR-6 4 200NH1AR-6 4 224NH1AR-6 4 250NH1AR-6 4 315NH1AR-6 C C C C C C C C C C C C D D D D 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 32/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/660V AC 160/660V AC 200/660V AC 250/660V AC 280/660V AC 315/660V AC 355/660V AC 400/660V AC 32NH2GR-6 40NH2GR-6 50NH2GR-6 63NH2GR-6 80NH2GR-6 4 100NH2GR-6 4 125NH2GR-6 4 160NH2AR-6 4 200NH2AR-6 4 250NH2AR-6 4 280NH2AR-6 4 315NH2AR-6 4 355NH2AR-6 4 400NH2AR-6 4 E E E E E E E E E E E F E F 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Approximate Dimensions for NH Fuses mm (in.)* NH Size/Dim. C00 00/A 0/B 1/C 1/D 2/E 2/F Overall Length (L1) Body Length (L2) Body Depth (D) Body Width (W) Blade Width (T) Blade Thickness (C) 79(3.11) 79(3.11) 125 (4.92) 135 (5.31) 135 (5.31) 150 (5.91) 150 (5.91) 53 (2.09) 52 (2.05) 65 (2.56) 65 (2.56) 65 (2.56) 65 (2.56) 65 (2.56) 40 (1.57) 42.5 (1.67) 42 (1.65) 42 (1.65) 48 (1.89) 48 (1.89) 60 (2.36) 21 (0.83) 28 (1.10) 29 (1.14) 29 (1.14) 40 (1.57) 40 (1.57) 53 (2.10) 6 (0.24) 6 (0.24) 6 (0.24) 6 (0.24) 6 (0.24) 6 (0.24) 6 (0.24) 15 (0.59) 15 (0.59) 15 (0.59) 15 (0.59) 20 (0.79) 20 (0.79) 26 (1.02) Fixing Center (F) 110 (4.33) 110 (4.33) 110 (4.33) 110 (4.33) 110 (4.33) 110 (4.33) 110 (4.33) *Dimensions to DIN 43620 refer to diagram on pg 16 Altech Corp.® ● 35 Royal Road Flemington NJ 08822-6000 ● Phone (908) 806-9400 ● Fax (908) 806-9490 ● www.altechcorp.com 17 NH KNIFE BLADE NH 3 Current/ Voltage Cat. No. Operating Class gG / gL (VDE 0636 / IEC 269) Line Protection up to 500V AC (660V Available) 224/500V AC 250/500V AC 300/500V AC 315/500V AC 355/500V AC 400/500V AC 500/500V AC 630/500V AC Operating Class aM (VDE 0636 / IEC 269) Motor Protection up to 660V AC Operating Class aR (VDE 0636 / IEC 269) Semiconductor Protection up to 660V AC (1000V Available) Ordering Information 4 Knife blade is available with screw holes, please designate a “B” after the size, (ex. 250NH3BAR-6). 5 Also available in 660VAC, please consult Altech. NH 4 Current/ Voltage Dim. Std. Pk. Cat. No. Dim. Std. Pk. 224NH3GL 250NH3GL 300NH3GL 315NH3GL 355NH3GL 400NH3GL 500NH3GL 630NH3GL F F F F F F G G 3 3 3 3 3 3 3 3 400/500V AC 5 500/500V AC 5 630/500V AC 5 710/500V AC 800/500V AC 5 850/500V AC 900/500V AC 1000/500V AC 1250/500V AC 1600/500V AC 400NH4GL 500NH4GL 630NH4GL 710NH4GL 800NH4GL 850NH4GL 900NH4GL 1000NH4GL 1250NH4GL 1600NH4GL H H H H H H H H H I 1 1 1 1 1 1 1 1 1 1 224/500V AC 250/500V AC 300/500V AC 315/500V AC 355/500V AC 400/500V AC 500/500V AC 630/500V AC 224NH3AM 250NH3AM 300NH3AM 315NH3AM 355NH3AM 400NH3AM 500NH3AM 630NH3AM F F F F F F G G 3 3 3 3 3 3 3 3 400/500V AC 400NH4AM 500/500V AC 500NH4AM 630/500V AC 5 630NH4AM 800/500V AC 5 800NH4AM 1000/500V AC5 1000NH4AM 1250/500V AC 1250NH4AM H H H H H H 1 1 1 1 1 1 250/660V AC 280/660V AC 300/660V AC 315/660V AC 355/660V AC 400/660V AC 500/660V AC 560/660V AC 630/660V AC 250NH3AR-64 280NH3AR-64 300NH3AR-64 315NH3AR-64 355NH3AR-64 400NH3AR-64 500NH3AR-64 560NH3AR-64 630NH3AR-64 F F F F F F G G G 3 3 3 3 3 3 3 3 3 For Accessories, please refer to pg 19 For Accessories, please refer to pg 19 Approximate Dimensions for NH Fuses mm (in.)* NH Overall Size/Dim. Length (L1) 3/F 3/G 4/H 4/I 150 (5.91) 150 (5.91) 200 (7.87) 200 (7.87) Body Length (L2) 65 (2.56) 65 (2.56) 65 (2.56) 87 (3.42) Body Depth (D) Body Blade Width (W) Thickness (T) 60 (2.36) 53 (2.10) 70 (2.75) 62 (2.44) 110 (4.33) 102 (4.01) 110 (4.33) 102 (4.01) 6 (0.24) 6 (0.24) 8 (0.31) 8 (0.31) Blade Depth (C) 26 (1.02) 32 (1.26) 50 (1.97) 50 (1.97) Fixing Center (F) 110 (4.33) 110 (4.33) 150 (5.91) 150 (5.91) *Dimensions to DIN 43620 refer to diagram on pg 16 18 Altech Corp.® ● 35 Royal Road Flemington NJ 08822-6000 ● Phone (908) 806-9400 ● Fax (908) 806-9490 ● www.altechcorp.com NH FUSE ACCESSORIES FUSE BASE Fuse Bases hold fuses in place and insure proper electrical connections. Available in one or three pole designs. Three-pole Fuse Bases are supplied with two Separator Plates which should be installed between poles. We recommend the use of End Plates and Terminal Covers for increased safety. END PLATE End Plates increase safety and provide separation between devices. Install by inserting End Plate into mounting entry slot on right or left side of Fuse Base. We recommend installing one End Plate on each side of the Fuse Base. TERMINAL COVER Covers increase safety by covering the conducting metal hardware of the Fuse Base and the Fuse. We suggest Terminal Covers be used in conjunction with End Plates. To install slide Terminal Cover over terminal slot and snap in place. MICROSWITCH Microswitches can be field mounted on NH fuses for remote blown fuse indication. (Sketch below) Fuse Base Fuse End Plate No. of Poles Cat. No. Length mm (in.) Use With Fuse(s) 1 3 NHB00-1 NHB00-3 122 (4.80) 139 (5.47) NH00 NH00 1 NHB0-1 170 (6.69) NH0 NHEP0 62 (2.44) 180 (7.09) NHB0-1-3 1 3 NHB1-1 NHB1-3 202 (7.95) 214 (8.42) NH1 NH1 NHEP1 62 (2.44) 214 (8.42) NHB1-1-3 1 3 NHB2-1 NHB2-3 227 (8.94) 260 (10.24) NH2 NH2 NHEP2 90 (3.54) 260 (10.24) NHB2-1-3 1 NHB3-1 242 (9.53) NH3 NHEP3 101 (3.98) 242 (9.53) NHB3-1-3 1 NHB4-1 310 (12.20) NH4 1 NHB4A-1 338 (13.31) NH4A 1 NHSMB 146 (5.75) NH00SM Cat. No. NHEP00 62 (2.44) 121 (4.76) Microswitch Microswitch Fuse Cat. No. NHMS Current/ Voltage Approx.Dim. mm (in.) Use With Width Length Fuse Base(s) NHB00-1-3 Terminal Cover Use With Fuse(s) 5/250V AC NH Knife Blade (SPDT) or NH Stud Mount (All Sizes) Cat. No. Use With Fuse Base(s) NHTC00 NHB00-1-3 FUSE HANDLE We strongly suggest using the Fuse Handle when inserting or removing fuses from the Fuse Base to prevent electrical shocks. For increased safety, use Fuse Handle with integral safety glove. Both Fuse Handles are for use with NH-Knife Blade Fuses, NH00 - NH4. Fuse Handle Cat. No. Description NHHA Fuse Handle NHSG Fuse Handle with Safety Glove For maximum protection use Fuse Handle with integral safety glove, not shown. Altech Corp.® ● 35 Royal Road Flemington NJ 08822-6000 ● Phone (908) 806-9400 ● Fax (908) 806-9490 ● www.altechcorp.com 19 NH STUD MOUNT Semiconductor Semiconductor Fuses have extremely fast acting trip characteristics and provide short circuit and overload protection for diodes, SCR's etc. Current limiting, super fast blow. USA upon request Semiconductor Fuses offered comply with IEC, DIN and VDE standards and are available in two trip characteristics, defined below. For Accessories, please refer to pg 19 for NH Fuses. Operating Classes (VDE 0636 / IEC 269) gR - Full Range Protection Overload and short circuit protection. Typical Markings: Ultra Rapid™, Silcu™, Recticur™, Protistor™, Ultra QuickTM, gR Mostly red, orange, or blue imprint. aR - Partial Range Protection Short circuit protection only. Faster acting than full range fuses. NH00C/SM NH00C/SM-L Stud Mount sp Stud Mount with Microswitch Holder Class gR Current/ Voltage 16/660V AC 20/660V AC 25/660V AC 32/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/660V AC Class gR Cat. No. 1 1 1 1 1 1 Std. Pk. 16SM00CGR 20SM00CGR 25SM00CGR 32SM00CGR 40SM00CGR 50SM00CGR 63SM00CGR 80SM00CGR 100SM00CGR 125SM00CGR 3 3 3 3 3 3 3 3 3 3 Current/ Voltage Cat. No. 16/660V AC 20/660V AC 25/660V AC 32/660V AC 35/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/660V AC Std. Pk. 16SM00CGR-L 20SM00CGR-L 25SM00CGR-L 32SM00CGR-L 35SM00CGR-L 40SM00CGR-L 50SM00CGR-L 63SM00CGR-L 80SM00CGR-L 100SM00CGR-L 125SM00CGR-L 3 3 3 3 3 3 3 3 3 3 3 Typical Markings: Ultra Rapid™, Silcu™, Recticur™, Protistor™, Ultra QuickTM, aR Class aR Mostly red, orange, or blue imprint. 160/660V AC 1 200/660V AC 1 250/660V AC 1 315/500V AC 1 Class aR 160SM00CAR 200SM00CAR 250SM00CAR 315SM00CAR 3 3 3 3 160/660V AC 180/660V AC 160SM00CAR-L 180SM00CAR-L 3 3 Microswitch D E A 1 UL recognized version available upon request. UL rated at 700VAC. 2 Also available in operating class aR. 20 Altech Corp.® ● 35 Royal Road Flemington NJ 08822-6000 ● Phone (908) 806-9400 ● Fax (908) 806-9490 ● www.altechcorp.com USA upon request NH00/SM NH00/SM-L NH0/SM-L Stud Mount sp Stud Mount with Microswitch Holder Stud Mount with Microswitch Holder Class gR Current/ Voltage 16/660V AC 2 20/660V AC 2 25/660V AC 2 32/660V AC 2 35/660V AC 2 40/660V AC 2 50/660V AC 2 63/660V AC 2 80/660V AC 2 100/660V AC 2 125/660V AC 2 Cat. No. 16SM00GR 20SM00GR 25SM00GR 32SM00GR 35SM00GR 40SM00GR 50SM00GR 63SM00GR 80SM00GR 100SM00GR 125SM00GR Class gR Std. Pk. 3 3 3 3 3 3 3 3 3 3 3 Current/ Voltage Cat. No. 6/660V AC 2 10/660V AC 2 16/660V AC 2 20/660V AC 2 25/660V AC 2 32/660V AC 2 35/660V AC 2 40/660V AC 2 50/660V AC 2 63/660V AC 2 80/660V AC 2 100/660V AC 2 125/660V AC 2 6SM00GR-L 10SM00GR-L 16SM00GR-L 20SM00GR-L 25SM00GR-L 32SM00GR-L 35SM00GR-L 40SM00GR-L 50SM00GR-L 63SM00GR-L 80SM00GR-L 100SM00GR-L 125SM00GR-L Class aR 160/660V AC 1 200/660V AC 1 250/660V AC 1 315/660V AC 1 350/660V AC 1 400/660V AC 2 160SM00AR 200SM00AR 250SM00AR 315SM00AR 350SM00AR 400SM00AR Class gR Std. Pk. 3 3 3 3 3 3 3 3 3 3 3 3 3 Current/ Voltage 6/660V AC 10/660V AC 16/660V AC 20/660V AC 25/660V AC 32/660V AC 35/660V AC 40/660V AC 50/660V AC 63/660V AC 80/660V AC 100/660V AC 125/660V AC Class aR 3 3 3 3 3 3 160/660V AC 200/660V AC 250/660V AC 315/660V AC 350/660V AC 400/660V AC 160SM00AR-L 200SM00AR-L 250SM00AR-L 315SM00AR-L 350SM00AR-L 400SM00AR-L Cat. No. Std. Pk. 6SM0GR-L 10SM0GR-L 16SM0GR-L 20SM0GR-L 25SM0GR-L 32SM0GR-L 35SM0GR-L 40SM0GR-L 50SM0GR-L 63SM0GR-L 80SM0GR-L 100SM0GR-L 125SM0GR-L 3 3 3 3 3 3 3 3 3 3 3 3 3 Class aR 3 3 3 3 3 3 160/660V AC 160SM0AR-L 3 Approximate Dimensions Stud Mount mm (in.)* D B Dim. A B C D E NHC00 55 (2.17) 80 (3.15) 100 (3.94) 20 (0.79) 39 (1.54) NH00 55 (2.17) 80 (3.15) 100 (3.94) 28 (1.10) 50 (1.97) NH0 69 (2.72) 97 (3.82) 120 (4.72) 28 (1.10) 50 (1.97) C *Dimensions to DIN 43653 Altech Corp.® ● 35 Royal Road Flemington NJ 08822-6000 ● Phone (908) 806-9400 ● Fax (908) 806-9490 ● www.altechcorp.com 21
160NH00GL 价格&库存

很抱歉,暂时无法提供与“160NH00GL”相匹配的价格&库存,您可以联系我们找货

免费人工找货