V-EA-Series - UL508 Manual Motor Controller - 3 pole G-Trip
Weight:
0.3A - 32A
1.8kg (3.97 lb.)
40A - 63A
1.98kg (4.37 lb.)
Three Pole
35 mm
(1.38 in.)
93.3 mm
(3.67 in.)
74.7 mm
(2.94 in.)
52.5 mm
(2.07 in.)
V-EA-G Trip
0.3A Through 10A Rated Current
1.05-1.35xIN
60
40
Minutes
Approvals
10
Thermal Overload
“Must Trip” = 125% Rated Current
“Must Not Trip” < 1 hr = 135% RC
“Must Not Trip” > 1 hr = 105% RC
“Must Not Trip” = Rated Current
4
1
Tripping time t
Standard Pack: 6
Type/
Cat. No.
3G03UM
3G05UM
NA
3G08UM
3G1UM
3G1.6UM
3G2UM
3G2.5UM
3G3UM
3G3.5UM
3G4UM
3G5UM
3G6UM
3G8UM
3G10UM
3G12UM
3G13UM
3G15UM
3G16UM
3G20UM
3G25UM
3G30UM
3G32UM
3G40UM
3G50UM
3G60UM
3G63UM
10
4
1
0.4
10-1
4x10-2
Seconds
E137938
Rated
Current
0.3A
0.5A
0.75A
0.8A
1.0A
1.6A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
6.0A
8.0A
10A
12A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
10-2
4x10-3
10-3
1
2
Backup
Protection
Amp Range
UL-Listed
RK5-Fuse
up to 10kA
UL-Listed
MCCB
up to 10kA
No BCP
Required
up to:
all
0.3 - 10A
4xRC*
min 15A, max 70A
4xRC*
min 15A, max 70A
10kA
all
12 - 30/32A
4xRC*
max 125A
4xRC*
max 125A
5kA
all
40 - 50A
4xRC*
max 200A
4xRC*
max 200A
5kA
all
60 / 63A
4xRC*
max 250A
4xRC*
max 250A
5kA
*up to nearest rated current
Tripping time t
480Y/277VAC
0.3-25A: 1 pole - 42VDC; 2 Pole - 80VDC
30-60A: 1 pole - 24VDC; 2 Pole - 60VDC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
40°C (104°F)
-25°C to 55°C (-13°F to 131°F)
-40°C to 70°C (-40°F to 158°F)
Top: 18-3 AWG; Bottom: 18-2 AWG (Line/Load reversible)
20 lb.in.
IP20
short circuit Withstand ratings for v-ea manual motor controller
Trip
Curve
40
100
1.05-1.35xIN
60
40
10
Thermal Overload
“Must Trip” = 125% Rated Current
“Must Not Trip” < 1 hr = 135% RC
“Must Not Trip” > 1 hr = 105% RC
“Must Not Trip” = Rated Current
4
10
4
1
0.4
10-1
4x10-2
Seconds
Short Circuit Withstand Rating
(UL/CSA - Ratings)
Group Short Circuit Withstand Rating
(UL/CSA - Ratings)
Interrupting Capacity (VDE - Ratings)
Calibration Temperature
Operating Temperature
Storage Temperature
Terminal Size Acceptability
Terminal Torque
Terminal Protection Degree
20
V-EA-G Trip
12A Through 63A Rated Current
1
Voltage Rating
3 4 5 6 8 10
Multiple of Rated Current
Minutes
UL508 Listed
10-2
4x10-3
10-3
1
2
3 4 5 6 8 10
20
40
100
Multiple of Rated Current
Standard Dual
Connection Terminal
All parts are ring tongue compatible.
Ring
tongue
Box
clamp
很抱歉,暂时无法提供与“3G12UM”相匹配的价格&库存,您可以联系我们找货