0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
56.OW69.2011S

56.OW69.2011S

  • 厂商:

    ALTECH

  • 封装:

  • 描述:

    OW566920V 1NO/1NC AGNI10+5UMAU I

  • 详情介绍
  • 数据手册
  • 价格&库存
56.OW69.2011S 数据手册
Safety_Relays_2013.QXD_SafetyRelays2005.QXD 1/9/14 10:52 AM Page 6 Safety Relay OA/OW 5669 Features n n 2 output contacts International approvals: TÜV, UL, cUL n Quality control check for each safety relay n Forced-guided contacts, all gold flash plated n Contact Gap > 0.5 mm throughout life of relay n n n n n n Various contact materials, mixed contact material optional High coil voltage range High breakdown voltage: contact/coil ≥ 4 KV contact/contact ≥ 4KV High creeping distance: contact/coil ≥ 8 mm contact/contact ≥ 5.5 mm Protection Rating OA Version: IP 40, flow solder proof OW Version: IP 67, washable US C Custom design available, -coil voltage -coil resistance, -contact pressure -operate/release time GERMANY USA/CANADA E146415 Technical Data n Nominal Coil Voltage ....................................................... ........................................ 6, 12, 20, 24, 48, 60, 110, DC n n Coil Power Dissipation ..........................................0.7 W n n Max. Switching Voltage ....................250V DC, 400V AC n n Max. Switching Current .........8 A (2 x 5A simultaneous) n Max. Switching Power — DC .......................................... ........................................200W (2 x 160W simultaneous) n Max. Switching Power — AC .......................................... ...................................2000VA (2 x1250VA simultaneous) Operation Vibration .........................0.35 mm Ampl. max ........................................................@ 10...55Hz, 5g max Contact Arrangements .....1NO/1NC, 2CO, 2NO*, 2NC* Contact Material...................AgNi10+0.2µmAu Standard ...................AgSnO2+0.2µmAu, AgNi10+5µmAu Optional n Mechanical Life ......................≥ 50x106 operation cycles n Electrical Life ...................AgSnO2 >2x105, AgNi10 >105 n Ambient Temperature....................................-40...+70°C ......................operation cycles @ 230V AC, 6A, cos ϕ=1 n Contact Switching Rate .........10 operations per second n n Cover Material ..............................................Polyamide 6 Relay Operate Time ........................................... ≤ 15 ms n n Weight........................................................................15 g Relay Release Time ........................................... ≤ 12 ms n More detailed data upon request 1,7 Limitation factor F 1,6 1,5 U B max. I K 2A 1,4 1,3 1,2 I K= 8A 1,1 1,0 UB 0,9 UN 0,8 . U B min 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0,7 0,6 0,5 -40 -20 0 40 20 Ambient temperature 60 80 100 120°C Relay operation voltage vs. ambient temperature 0.2 0.2 0.4 0.6 0.8 1 Power factor (cos ϕ ) Operations = Operations (ohmic) x limitation factor F Limitation factor for inductive loads 108 6 4 260 2 220 107 6 4 180 Switching cycles 1,8 Switching voltage U [ V] Diagrams 140 100 60 20 0 0.2 0.4 0.60.81 2 4 6 8 10 Switching current l [A] Safe disconnection, no remaining arc, max. 1 operation/sec. Maximum switching power curve 2 106 6 4 2 AgSnO2 AgNi10 105 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Switching capacity P [kVA] Mechanical life *Special order. 6 Altech Corp.® • 35 Royal Road • Flemington NJ 08822-6000 • Phone (908) 806-9400 • FAX (908) 806-9490 • www.altechcorp.com Safety_Relays_2013.QXD_SafetyRelays2005.QXD 1/9/14 10:52 AM Page 7 Safety Relay OA/OW 5669 Data Relay Data Rated Voltage Voltage Range Ordering Information Coil Resistance 1 NO/1 NC Type 2 CO Type 2 NO* Type 2 NC* Type (10%) 6V 10V 12V 20V 24V 48V 60V 110V 4.8 8.0 9.6 16.0 19.2 38.4 48.0 88.0 - 9.6V - 16.0V - 19.2V - 32.0V - 38.4V - 76.8V - 96.0V - 176.0V 50 150 210 580 820 3200 5200 18000 Ω Ω Ω Ω Ω Ω Ω Ω 56.O 56.O 56.O 56.O 56.O 56.O 56.O 56.O 69.0611 69.1011 69.1211 69.2011 69.2411 69.4811 69.6011 69.1111 56.O 56.O 56.O 56.O 56.O 56.O 56.O 56.O 69.0600 69.1000 69.1200 69.2000 69.2400 69.4800 69.6000 69.1100 Protection Class, Example: A IP 40, Flow Solder Proof W IP 67, Washable 56.O 56.O 56.O 56.O 56.O 56.O 56.O 56.O 69.0620 69.1020 69.1220 69.2020 69.2420 69.4820 69.6020 69.1120 56.O 56.O 56.O 56.O 56.O 56.O 56.O 56.O 69.0602 69.1002 69.1202 69.2002 69.2402 69.4802 69.6002 69.1102 Contact Material, Example: C AgSnO2+.2µmAu N AgNi10+.2µmAu S AgNi0.15+5µmAu Footprints (solder side) 2 NO 1 NO/1 NC 2 CO 2 NC Dimensions Note: All dimensions are shown in millimeters. To convert to inches, divide by 25.4. *Special order. Altech Corp. • 35 Royal Road • Flemington NJ 08822-6000 • Phone (908) 806-9400 • FAX (908) 806-9490 • www.altechcorp.com ® 7
56.OW69.2011S
物料型号:Altech Safety Relay OA/OW 5669

器件简介:这是一个安全继电器,具有2个输出接触点,并通过国际认证,如TÜV、UL、cUL。每个安全继电器都经过质量控制检查,具有强制引导接触点,所有接触点都镀有金层。接触间隙在继电器的整个寿命中都大于0.5毫米。

引脚分配:文档中提供了不同类型继电器的引脚分配,包括1NO/1NC型、2CO型、2NO型和2NC型。

参数特性:包括额定线圈电压范围、接触开关速率、继电器操作时间、继电器释放时间、线圈功耗、最大开关电压和电流、接触材料、机械寿命和电气寿命等。

功能详解:文档提供了继电器的操作振动、最大开关功率、环境温度范围、外壳材料、重量等详细信息。

应用信息:文档中提到了继电器的应用,包括安全断开、无剩余电弧、最大1次/秒的操作。

封装信息:提供了继电器的尺寸信息,包括最大尺寸和引脚布局。
56.OW69.2011S 价格&库存

很抱歉,暂时无法提供与“56.OW69.2011S”相匹配的价格&库存,您可以联系我们找货

免费人工找货