Technical Data
Safety switch
Series SKC- with separate actuator
Description SKC-A1Z MRU
Article number 6016169087
Terminal screw acc. to
DIN 912 M5
Operating symbol
Operating diagram
Ø5.5 fixed location for
safety application
Actuator
withdrawn
inserted
On
Off
Tolerance:
Operating Point ± 0,25 mm;
Operating force ± 10 %
Electrical Data
Rated insulation voltage
Conv. thermal current
Utilization category
Direct opening action
Short-circuit protective device
Protection class
Ui
Ithe
p
250 V AC
5A
AC-15, Ue /Ie 240 V / 1,5 A
according to IEC/EN 60947-5-1, Annex K
Fuse 6 A gG
II, totally insulated
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-07-04 and will not be removed in case of changes.
Page 1 of 3
6016169087 / 2208-16
Technical Data
Mechanical data
Enclosure
Cover
Actuator
Extraction force
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Thermoplastic, glass fibre reinforced (UL94-V0)
Thermoplastic, glass fibre reinforced (UL94-V0)
Separate actuator (metal)
10 N
-30 °C … +80 °C
1 NC (Y)
1 x 106 switching cycles
≤ 30 / min.
Assembly
2 x M5
2 x M5
Safety switch
Actuator
Connection
2 screw connections (M3,5)
Conductor cross-sections
Solid: 0,5 ... 1,5 mm²
Litz wire with ferrules: 0,5 ... 1,5 mm²
Cable entrance
Weight
Installation position
Protection type
3 x M16 x 1,5
≈ 0,13 kg
operator definable
IP65 acc. to IEC/EN 60529
ID for safety engineering
B10d
2 x 106 switching cycles
Actuation
Turning the cap (pos A/B) allows 4 different directions of drive.
Cover (1) has to be opened before turning the cap (2).
Insert the screwdriver into the gap between housing and cap and
turn until the cap snaps off.
Remove the cap, turn it 180° (4), latch it into the housing and close the cover.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC
Approvals
TÜV Rheinland, Product Safety
B300 (same polarity)
CCSAUS
CCC
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-07-04 and will not be removed in case of changes.
Page 2 of 3
6016169087 / 2208-16
Technical Data
Notes
The degree of protection (IP code) specified applies solely to a property closed cover
and the use of an equivalent cable gland with adequate cable.
The switch may not be used as a mechanical stop.
Radial actuation may reduce the mechanical life.
The min. radius refers to a pivot at the top of the cap (S0).
Tapped holes not in use must be closed with blind plugs.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-07-04 and will not be removed in case of changes.
Page 3 of 3
6016169087 / 2208-16
很抱歉,暂时无法提供与“601.6169.087”相匹配的价格&库存,您可以联系我们找货