Technical Data
Safety switch
Series Safety Hinge Switch SHS
Description SHS-A1Z-SR-BG
Article number 6019261018
Circuit diagram
Operating diagram
Fixing point
Fixing point in the range 0° ... 180° freely selectable
Connection
le
ng
el a
wiv
s
ON
OFF
Tolerances:
switching angle (opening) +2,0 ° / -1,5 °,
direct opening torque 10 %,
direct opening angle +0,5 ° / -3 °
Switching angle hysteresis
(closing the N.C. contact –1,0 °)
from the hinge’s typical switch-off point
Illustration with fixed shaft and sheared-off set screw.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-01-07 and will not be removed in case of changes.
Page 1 of 3
6019261018 / 2017-16
Technical Data
Electrical Data
Rated insulation voltage
Rated impulse withstand voltage
Conv. thermal current
Rated operational voltage
Utilization category
Direct opening action
Short-circuit protective device
Protection class
Ui
Uimp
Ithe
Ue
�
250 V
2,5 kV
3A
230 V AC / 60 V DC
AC-15, 230 V AC / 1,5 A, DC-13, 60 V DC / 0,5 A
acc. to IEC/EN 60947-5-1, annex K
Fuse 4 A gG
I
Mechanical data
Enclosure
Cover
Wing
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Attachment
Connection type
Weight
Installation position
Protection type
Switching angle
Direct opening angle
Direct opening torque
Mechanical load
(see dimensioned drawing for the
introduction direction of the forces)
GD-Zn
GD-Zn
GD-Zn
-25 °C to +70 °C
1 NC
1 x 106 operating cycles
max. 1200 switching operations / hour
4 x M6 screws DIN 7984 or DIN 6912
Plug M12x1, metal thread
≈ 0,4 kg
operator definable
IP 67 in acc. with IEC/EN 60529
+/- 3 ° from fixing point
+/- 10 ° from fixing point
1,5 Nm
FR1= max. 1000 N
FR2= max. 500 N
FA = max. 750 N
ID for safety engineering
B10d
2 x 106 switching cycles
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC
Approvals
DGUV
CCSAUS C300
CCC
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-01-07 and will not be removed in case of changes.
Page 2 of 3
6019261018 / 2017-16
Technical Data
Notes
The safety fixture must always be attached by at least two SHS! See max. load.
If the risk assessment of the machine permits a single-channel evaluation, an empty hinge can be used as the support element.
If the SHS is used at an ambient temperature of 70 °C, it is possible that the connecting cable will age more rapidly!
The connecting cable must be protected against mechanical damage.
The cable can be installed in tubes or cable ducts.
The electrical connection for a SHS with DGUV inspection certificate is only permitted with
the following cable couplings (Bernstein range; cable length: 5 m):
3251103234 (with straight plug) or 3251103236 (with angled plug)
The fastening nut of the connecting cable coupling must be in a closed area after assembly that can only be opened
with a tool (manipulation guard; e.g. hollow profile, machine stand, frame,...).
The manufacturer / supplier of the machine / system is obligated to observe the applicable standards for the size of the safety
intervals between the separating safety fixture and the hazard point.
These regulations include: EN 294, EN 349, EN 953, EN 1088, ... .
The switch may not be used as a stop.
For a CSA/UL application it is essential to use CSA/UL approved cable for connection.
The suggested protection type (IP code), applies only when at least an equivalent cable coupling is used.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-01-07 and will not be removed in case of changes.
Page 3 of 3
6019261018 / 2017-16
很抱歉,暂时无法提供与“601.9261.018”相匹配的价格&库存,您可以联系我们找货