Technical Data
Safety switch
Series SKC- with separate actuator
Description SKC-A1Z F30 M
Article number 6116169016
Operating symbol
27
28.5
40
7.5
52
Terminal screw acc. to
DIN 912 M5
10.5
8
40
ø5.2
5
8
18
29
7
Actuator
withdrawn
Ø5.5 fixed location for
safety application
75
21.5mm
M16 x 1,5
11-12
Operating diagram
17.5
5.5
13
M16x1.5
14.5
40
0mm
14
8
30
S0
inserted
30
On
Off
33
8
6
5
ø5.5
52
Tolerance:
Operating Point ± 0,25 mm;
Operating force ± 10 %
Electrical Data
Rated insulation voltage
Conv. thermal current
Utilization category
Direct opening action
Short-circuit protective device
Protection class
Ui
Ithe
p
250 V AC
5A
AC-15, Ue /Ie 240 V / 1,5 A
according to IEC/EN 60947-5-1, Annex K
Fuse 6 A gG
II, totally insulated
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-07-04 and will not be removed in case of changes.
Page 1 of 2
6116169016 / 2208-16
Technical Data
Mechanical data
Enclosure
Cover
Actuator
Extraction force
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Assembly
Safety switch
Actuator
Connection
Conductor cross-sections
Cable entrance
Weight
Installation position
Protection type
Thermoplastic, glass fibre reinforced (UL94-V0)
Thermoplastic, glass fibre reinforced (UL94-V0)
Separate actuator (G-stainless steel)
30 N
-30 °C … +80 °C
1 NC (Y)
1 x 106 switch operations
≤ 30 / min.
2 x M5
2 x M5
2 screw connections (M3,5)
Solid: 0,5 ... 1,5 mm²
Litz wire with ferrules: 0,5 ... 1,5 mm²
3 x M16 x 1,5
≈ 0,13 kg
operator definable
IP65 acc. to IEC/EN 60529
ID for safety engineering
B10d
2 x 106 switching cycles
Actuation
Turning the cap (pos A/B) allows 4 different directions of drive.
Cover (1) has to be opened before turning the cap (2).
Insert the screwdriver into the gap between housing and cap and
turn until the cap snaps off.
Remove the cap, turn it 180° (4), latch it into the housing and close the cover.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC
Approvals
TÜV Rheinland, Product Safety
CCC
B300 (same polarity)
CCSAUS
Notes
R min.
R min
. 150
150
22
s
0
7.5
The degree of protection (IP code) specified applies solely to a property closed cover
and the use of an equivalent cable gland with adequate cable.
The switch may not be used as a mechanical stop.
Radial actuation may reduce the mechanical life.
The min. radius refers to a pivot at the top of the cap (S0).
Tapped holes not in use must be closed with blind plugs.
16
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-07-04 and will not be removed in case of changes.
Page 2 of 2
6116169016 / 2208-16
很抱歉,暂时无法提供与“611.6169.016”相匹配的价格&库存,您可以联系我们找货