0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CBI2410A

CBI2410A

  • 厂商:

    ALTECH

  • 封装:

    -

  • 描述:

    CBI2410A

  • 数据手册
  • 价格&库存
CBI2410A 数据手册
CBI_Brochure_Final.pdf C M Y CM MY CY CMY K 2 3/21/14 4:53 PM CBI_Brochure_Final.pdf 3 3/21/14 CBI Series DC-UPS Solutions (pages 4-11) 4:53 PM CBI All In One UPS Power Solutions combine the requirements for several applications in just one device which can be used as power supply unit, battery charger, battery care module or backup module. The available power is automatically distributed among load and battery, while supplying power to the load always is the first priority. The maximum available current of the load output is two times the value of the device’s rated current. If the device is disconnected from the main power source, the battery will supply the load until the battery voltage reaches 1.5 V per cell. This prevents the battery from deep discharge. CBI devices provide microprocessor controlled battery charging. Using algorithms, the battery’s condition will be detected and based on that, an appropriate charging mode is chosen. The real-time diagnostics system will continuously monitor the charging progress and indicate possibly occurring faults such as elements in short circuit, accidental reverse polarity connection or disconnection of the battery by the battery fault LED and a flashing code of the diagnosis LED. CBI All In One UPS Power Solutions are suitable for open/sealed lead acid-, lead gel- and optionally Ni-Cd batteries. By using the battery-select-jumper, it is possible to set predefined charging curves for those battery types. The available charging options are recovery-, boost- and trickle charge. All CB devices are built in a rugged metal case with a DIN rail mounting bracket. Features: • Power supply, battery charger, battery care module and backup module in one device • Three charging modes • Compact, rugged metal case • Available in 12VDC, 24VDC and 48VDC • Suitable for most common battery types • Adjustable charging current • Easy battery diagnosis and fault identification either by LED or external devices connected to fault • Status contacts • High efficiency up to 91% through switching technology • Several output protection features such as short circuit, overload, deep battery discharge etc. • DIN rail mounting • Small size • 3 year warranty C M Y CM MY CY CMY K Battery Charging Output Load Output Monitor Signal Switch Contacts DIN Rail Mounting Charging Level Mains LED Low Battery LED Diagnosis LED Battery Start Push Button Battery Type Configuration Jumper AC Input 2 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com CBI_Brochure_Final.pdf 4 3/21/14 CB Series Battery Chargers (pages 12-15) 4:53 PM With the CB Battery Charger Line, Altech offers a highly reliable battery management solution. Operating at single phase Input Voltages of 115-230-277 VAC, the devices supply an Output of 12VDC and up to 35A or 24VDC and up to 20A. Equipped with microcontrollers, the CB line offers fully automated multi-stage charging that will expand the battery's life significantly. Several diagnostic and monitoring features ensure easy handling and a high amount of transparency during daily operation. Altech's CB line battery chargers are based on the switching technology which allows much higher efficiency as well as smaller and lighter devices. Additionally, several standard safety and protection features ensure safe installation and operation. Features: C M • Fully automated charging • Three charging modes • Compact, rugged metal case • Available in 12VDC and 24VDC • Suitable for most common battery types • Adjustable charging current • Easy battery diagnosis and fault identification either by LED or external devices connected to fault status contacts • High efficiency up to 91% through switching technology • Several output protection features such as short circuit, overload, deep battery discharge etc. • DIN rail mounting • Small size • 3 year warranty Y Fault Status Contacts CM MY CY DC Output CMY DIN Rail Mounting K Charging Level Battery Fault LED Diagnosis LED Battery Type Configuration Jumper AC Input Applications for CBI & CB Series: Acoustic Evacuations As Mini DC-UPS in industrial applications Power Supply + Back Up Module Audio Backup, Lighting Backup, Greenhouse Control, etc. Automatic Revolving Doors, Access Control, CCTV, Alarms, etc. Automotive Service Centers, Cars, Motorbikes, etc. E-Car, Off-Highway Equipment/Machinery, E-Scooter, Electric Vehicles (on-board chargers) Emergency Backup Fire Protection Systems, etc. Firing System Forklifts, Scissors Lifts, Pallet Trucks, Generator Sets (Gen set, Engine Starting, etc.) Golf Carts, Wheel Chairs, etc. Industrial Water Pumping Light Security Marine Applications Motorway Light Message Boards Portable Equipment Power Supply Continuity Remote Measurement Station, etc. Remote measurement stations Security Doors For Banks Security Systems Security Vision Control Telecommunications Waterworks Control Wireless Control Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 3 CBI_Brochure_Final.pdf 5 3/21/14 CBI Series DC-UPS Solutions Everything and more! • More efficiency of the battery thanks to continuous control over time. • More monitoring in main connection nodes: input, output load, battery. • Event logging: number of battery charging cycles, charge cycles completed, aborted charge cycles, Ah charged, charging time, total number of transitions stand-by /back-up etc... C 4:53 PM Power continuity DC-UPS = Power Supply + Smart battery management Battery Charger + Back Up module Load output will not be affected by Double Output, Optimized Power Man agement. Thanks to the DC-UPS units, it will be possible to smart-manage available power. It will be automatically allocated between load and battery. Supplying power to the load is the first priority of the unit; thus it is not neces sary to double the power, and also the power available for the battery will go to the load if the load requires so. Output Load: Power Boost: 12, 24, 48 In x 2 Continuous In x 3 max 4 sec. Battery Avoid deep battery discharge • Event Management: checking the load output, shutdown management of PCs (UPS function), RESET management of a generic equipment. CM MY CY In case of mains failure, the battery will supply the load until battery voltage reaches 1.5 Vpc (Volt per cell). Below this level the device automatically switches off to prevent deep discharge and battery damage. CMY • Flexibility of use: customization of the entire charging curve of the battery, battery type setting, setting of the various time-out algorithms of charge, setting boost voltage, absorption, float, etc... configuration as DC-UPS or batteries charger, enabling power supply function . K Load Load M Y battery conditions. The DC-UPS insures continuous power supply to the load even in conditions of completely discharged batteries. The automatic multi-stage operation optimizes and adapts to the battery status. DCUPS can recharge deeply discharged batteries even when their voltage is close to zero, thus allowing recharge and complete recovery of flat batteries. In Power Boost mode the maximum current on the load output is the 2 times the rated current (2 x In) in continuous operation and 3 times the rated current (3 x In) for max. 4 seconds. In 2 In 3 In Load In In I batt In I batt > 4 min. I batt max. 4 sec. Time buffering Time buffering is enabled when in back-up mode. Buffering time setting is possible by operating the rotary switch on the front panel. Adjustable maximum battery charging current The maximum battery charging current can be set from 10% to 100% of the device rated value. TIME BUFFERING 4 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com CBI_Brochure_Final.pdf 6 3/21/14 4:53 PM CBI Series DC-UPS Solutions Connection & monitoring Start from battery without main Monitor signals Accessories If you want to restart the system while the mains is off, a battery restart function is available, via RTCONN cable connections, or via pushbutton in the front panel. Clear definition of each system operation, via LED indications and Relay contact: All DC-UPS units can be made available with the following options by RJ45 or RJ11 connector: Contact Port signals, galvanic insulation ■ Main or back-up signaling relay with voltage-free. NO-NC output terminals. ■ Battery faulty signaling relay, relay with voltage-free. NO-NC output terminals. ■ Flat battery signaling relay, relay with voltage-free. NO-NC output terminals. Temperature sensor Probe, for ambient temperature compensation charging. Start from battery Voltage drop cable compensation. + Batt. C M Y CM Battery Start UP cable. Wide input voltage range Flexibility is given also by the wide range input voltage. The range of the devices accept input voltage 120 - 230 277 - 400 - 500 VAC. Display Signals by LED ■ Input Main On Off ■ Battery Fault ■ Low battery (capacity less than 30%) ■ Type of Battery charge mode ■ Help through “blinking code” the diagnosis of the system MY CY CMY K Input ity flexibil Auxiliary output “Aux 2 and "Aux 3” MODBUS and CANBUS connection for Multimedia management, for connection to external displays and perform customized data monitoring. Connection to: • Power View App • Power View System • Power Bus • Power View Graphic • Power View Bar Graph • Power View Config One device for output 12 or 24 VDC You can select the voltage between 12 or 24 VDC just before installing the device in your panel (available on selected products in the new Altech DC-UPS units). 24 12 C VD Driver Contact Remote link for selection of trickle/ boost charging Via RTCONN remote connections cable it is possible to drive the devices from Boost - Bulk to Trickle Float charge. It is also possible to permanently install a jumper for Boost Bulk Charging. AUX 2 AUX 3 C VD Boost flat charge Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 5 3/21/14 CBI Series DC-UPS Solutions C M Y CM MY These devices are completely automatic and can charge any kind of battery using factory pre-set charging curves suitable to the most common battery technologies: open lead acid, sealed lead acid, lead gel, Ni-Cd and Ni-MH. These devices are very flexible and can be customized to meet the needs of the user and the requirements of the application. After the installation, it is possible to carry out functional software updates just using any laptop computer. Doing so, your system can always be updated to changing requirements. The Battery Care concept is base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. Battery faults such as battery sulfated, elements in short circuit, accidental reverse polarity connection can easily be detected, identified and removed. The All in one Series meet the highest standards of quality and insure high reliability, with MTBF values up to 300.000 hours. 4:53 PM Battery care One device for all battery types All devices are suitable to charge most batteries types thank to user selectable charging curves. They can charge open lead acid, sealed lead acid, Gel, Ni-Cd, Ni-MH, Li Ion batteries. It is possible to change or add other charging curves connecting the device to a portable PC. Charging mode is then completely automatic. Open Lead Acid (factory preset): Trickle 2.23 V Boost 2.40 V Sealed Lead Acid (1): Trickle 2.25 V Boost 2.40 V Multi-Stage charging - Four charging modes Automatic multi-stage operation and real time diagnostic allows fast recharge and recovery of deeply discharged batteries, adding value and reliability to the system hosting the DC-UPS device. The type of charging is Voltages stabilized and Current stabilized IUoU. CBI battery chargers feature four charging modes, identified by a flashing code on a LED. ■ Recovery (5 Blinks / sec) able to recharge batteries even when their voltage is close to zero. ■ Boost - Bulk (2 Blinks / sec). ■ Absorption (1 Blinks / sec). ■ Trickle - Float (1 Blink / 2 sec). AGM Sealed Lead Acid (2): Trickle 2.27 V Boost 2.40 V Gel: Trickle 2.30 V Boost 2.40 V Recovery charge (blink 5/sec.) Optional: Ni/Cd, LI-Ion CY Charge Absorbtion Absorption 7 Boost CBI_Brochure_Final.pdf Trickle / Float Charge (blink 1/sec.) CMY Boost or flat charge K Start from battery Battery Life Test Battery type confi guration jumper L N PE Diagnosis of battery and device All CBI devices support the user during installation and operation. A LED flash ing sequence code allows to discrimi nate among various possible faults. Error conditions, LED Fault ON and LED Diagnosis flashing with sequence of: ■ 1 flash = Reverse polarity, wrong battery voltage ■ 2 flashes= Disconnected battery ■ 3 flashes = Battery element in short circuit Boost or float charge. ■ 4 flashes = Overload ■ 5 flashes = Battery to be replaced (Internal impedance Bad or Bad battery wire connection) 6 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com CBI_Brochure_Final.pdf 8 3/21/14 4:53 PM CBI Series DC-UPS Battery care Solutions Battery Life Test Diagnostic checks Max. safety and protection It guarantees battery reliability in time by continuously testing the internal impedance status. It avoids any possible risk of damages and grants also a permanent, reliable and safe connection of the battery to the power supply. The system, through a battery stimulation circuit with algorithms of evaluation of the detected parameter, is able to recognize sulfated batteries or batteries with a short-circuited cell. Check for accidental disconnection of the battery cables. DC-UPS detects accidental disconnection and immediately switches off output power. The DC-UPS series is designed to provide safe operation and long power supply and battery life. The following protections are standard features: C M Y CM Battery not connected If the battery is not connected the battery output is disabled. Test of wire connection impedance During trickle charge the resistance on the battery connection is checked every 20 sec. This to detect if the cable connection has been properly made. Battery in open circuit or sulfated Every four hours DC-UPS tests of internal impedance, while in trickle charging mode. All protections have automatic reset. No thermal fuse to be replaced. Reverse polarity check If the battery it is connected with inverted polarity, DC-UPS is automatically protected. Robust construction and easy installation All the units in the range have aluminum casing, DIN rail fastening clip and are light and compact. IP20 protection degree. MY CY CMY K Temperature Compensation In special application like fire fighting equipment, you can recharge the battery also with the temperature compensation charging function, for the best condition of your battery in the temperature fluctuation. • Outputs protected against short circuit and overload • Outputs in conformity to SELV and PELV conditions • High insulation between primary and secondary • Protection against deep battery discharge • Protection against reverse polarity connection • Detection of batteries with wrong rated voltage Test of battery voltage connections Appropriate voltage check, to prevent connection of wrong battery types. End of charge check When the battery it is completely full, the device automatically switches to trickle charging mode. Check for battery cells in short circuit Thanks to specific testing algorithms, the DC-UPS recognize batteries with cells in internal short circuit. Element in Short Circuit Technology The new DC-UPS range is based on two strategic know-how elements. Switching technology, we have 25 years of experience in design of advanced stabilized switching technology power supplies. A power supply/battery charger unit based on this technology is much more efficient. Back UP Module and Battery Care units, unlike most other state-of-the-art battery chargers, the DC-UPS series is equipped with complex algorithms which controls the charging process and enable several monitoring functions. The firmware implements the extended battery care know-how, result of many years of experience in this field. Norms In Conformity to: • IEC/EN 60335-2-29 Battery chargers; • EN60950 / UL60950; • Electrical safety EN54-4 Fire Detection and fire alarm systems; • EMC Directive; • DIN 41773 (Charging cycle) C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com US UL60950 7 CBI_Brochure_Final.pdf 9 3/21/14 4:53 PM CBI Series DC-UPS In VAC 12 VDC Battery Mains or Backup Battery Low or Battery Replacement Out load INPUT DATA OUTPUT DATA INPUT DATA Input voltage range Output VDC / IN Efficiency (50% of In) 12VDC - 3A - 36W Input voltage range 90 - 305 VAC Frequency 47 - 63 Hz ±6% Output VDC / IN 12VDC - 3A Efficiency (50% of In) 90% Over load and short-circuit protection ■ Over load and short-circuit protection Overheating thermal protection ■ Overheating thermal protection Reverse battery protection ■ Reverse battery protection Output voltage (at IN) VDC Output voltage (at at IN) VDC 10 - 14.4VDC Nominal current IN = Iload Nominal current IN = Iload 1.1 x In A ± 5% Continuous current (without battery) Iload = In Continuous current (without battery) Iload = In 3A Max current (with battery) Out: Iload = In + Ibatt Max current (with battery) Out: Iload = In + Ibatt 6A Max current (main input) Out: Iload (4sec.) Max current (main input) Out: Iload (4sec.) 9A max Max current output load: (Back Up) Iload (4sec.) Max current output load: (Back Up) Iload (4sec.) 6A max Push button or remote input control ■ Push button or remote input control Time Buffering Time Buffering Boost-Bulk charge (Typ. at IN) Boost-Bulk charge (Typ. at IN) 14.4VDC Max. time boost-bulk charge (Typ. at IN) Max. time boost-bulk charge (Typ. at IN) 15h Min. time boost-bulk charge (Typ. at IN) Min. time boost-bulk charge (Typ. at IN) 1min. Trickle-Float charge (Typ. at IN) Trickle-Float charge (Typ. at IN) 13.8VDC Charging current Limiting IN (Iadj) Charging current Limiting IN (Iadj) 20 ÷ 100 % / Ibatt MY CY CLIMATIC DATA GENERAL DATA OPTIONAL K AUXILIARY SIGNAL OUTPUT* OUTPUT FOR: (RELAY) CMY 8 12VDC - 6A - 72W 90 - 305 VAC 90 - 305 VAC 47 - 63 Hz ±6% 47 - 63 Hz ±6% 12VDC - 3A 12VDC - 6A 90% 90% ■ E353188 CBI126A CBI1210A 12VDCCBI1210A - 6A - 72W 12VDCCBI1235A - 10A - 120W CBI1235A 12VDC - 35A - 420W ■ ■ 12VDC - 10A - 120W 12VDC - 35A - 420W 90 - 135 VAC 90 - 305 VAC 90 - 305 90VAC - 135 VAC 180 - 305 VAC 90 - 305 VAC 180 - 305 VAC 47 - 63 Hz ±6% 47 - 63 Hz ±6% 47 - 63 Hz ±6% 47 - 63 Hz ±6% 47 - 63 Hz ±6% 12VDC - 6A 12VDC - 10A 12VDC - 35A 12VDC - 10A 12VDC - 35A 90% 90% > 91% 90% > 91% ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 10 - 14.4VDC 10 - 14.4VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 3A 6A 6A 12A 9A max 18A max 6A max 12A max - ■ ■ ■ ■ ■ 10 - 14.4VDC 10 - 14.4VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 6A 10A 12A 20A 18A max 30A max 12A max 20A max ■ - ■ ■ ■ ■ ■ 10 - 14.4VDC 10 - 14.4VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 10A 35A 20A 70A 30A max 105A max 20A max 70A max ■ - 10 - 14.4VDC 1.1 x In A ± 5% 35A 70A 105A max 70A max ■ ■ ■ BATTERY CHARGER OUTPUT CM AUXILIARY SIGNAL OUTPUT* OUTPUT FOR: (RELAY) Y Main or backup power Main or backup power ■ ■ Low battery and fault battery ■ Low battery and fault battery Temp. charging probe Temp. charging probe by ext. Probe UPS active UPS active Modbus - CAN Bus Modbus - CAN Bus Ambient temperature operation Ambient temperature operation -25 ÷ +70°C De rating Tª > (In) / De rating Tª > (In) De rating Tª > (In) / De rating Tª > (In) > 50° -2.5%(In) / °C Ambient temperature storage Ambient temperature storage -40 ÷ +85°C Humidity at 25 °C Humidity at 25 °C 95% to 25°C Cooling Cooling Auto Convection Isolation voltage (IN / OUT) Isolation voltage (IN / OUT) 3000VAC Isolation voltage (IN / PE) Isolation voltage (IN / PE) 1605VAC Isolation voltage (OUT / PE) Isolation voltage (OUT / PE) 500VAC Protection class (EN/IEC 60529) Protection class (EN/IEC 60529) IP 20 Reliability (MTBF IEC 61709) Reliability (MTBF IEC 61709) > 300 000 h Dimension (w-h-d) Dimension (w-h-d) 65x115x135 Safety standard approval Safety standard approval CE /C-UL Recognized 60950 Bar graph control panel Bar graph control panel Graphic multifunction control panel Graphic multifunction control panel System monitoring software System monitoring software System configuration software System configuration software Interface module modbus 485 - Ethernet Interface module modbus 485 - Ethernet Interface module cloud all in one - Ethernet Interface module cloud all in one - Ethernet Battery temp. compensation Probe RJTemp ■ Battery temp. compensation Probe RJTemp CLIMATIC DATA BATTERY CHARGER OUTPUT M E353188 ■ 14.4VDC 14.4VDC 14.4VDC 14.4VDC 14.4VDC 14.4VDC 14.4VDC 15h 15h 15h 15h 15h 15h 15h 1min. 1min. 1min. 1min. 1min. 1min. 1min. 13.8VDC 13.8VDC 13.8VDC 13.8VDC 13.8VDC 13.8VDC 13.8VDC 20 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel; Jumper config. type battery (NiCd optional) 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, V/cell(10 Sealed Lead, 2.3(Imax V/cell10%) gel; NiCd2.27 1.5V/cell elem.) trickle Jumper config. type battery (NiCd optional) NiCd 1.5V/cell (10 elem.) trickle (Imax 10%) Remote input control (AMP Type connector) Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Remote input control (AMP Type connector) Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Characteristic Curve IUoU, Automatic, 4 stage Characteristic Curve IUoU, Automatic, 4 stage GENERAL DATA C CBI123A 12VDCCBI126A - 3A - 36W ■ ■ ■ ■ ■ ■ ■ by ext. Probe by ext. Probe -25 ÷ +70°C -25 ÷ +70°C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C -40 ÷ +85°C -40 ÷ +85°C 95% to 25°C 95% to 25°C Auto Convection Auto Convection 3000VAC 3000VAC 1605VAC 1605VAC 500VAC 500VAC IP 20 IP 20 > 300 000 h > 300 000 h 65x115x135 65x115x135 CE /C-UL Recognized 60950 ■ ■ ■ ■ ■ ■ by ext. Probe by ext. Probe by ext. Probe by ext. Probe ■ -25 ÷ +70°C -25 ÷ +70°C -25 ÷ +70°C -25 ÷ +70°C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C -40 ÷ +85°C -40 ÷ +85°C -40 ÷ +85°C -40 ÷ +85°C 95% to 25°C 95% to 25°C 95% to 25°C 95% to 25°C Auto Convection Auto Convection Auto Convection Auto Convection 3000VAC 3000VAC 3000VAC 3000VAC 1605VAC 1605VAC 1605VAC 1605VAC 500VAC 500VAC 500VAC 500VAC IP 20 IP 20 IP 20 IP 20 > 300 000 h > 300 000 h > 300 000 h > 300 000 h 65x115x135 65x115x135 65x115x135 150x115x135 CE /C-UL Recognized 60950 CE /C-UL Recognized 60950 CE OPTIONAL LOAD OUTPUT LOAD OUTPUT OUTPUT DATA CBI123A Output Output Frequency E353188 Model Model by ext. Probe ■ -25 ÷ +70°C > 50° -2.5%(In) / °C -40 ÷ +85°C 95% to 25°C Auto Convection 3000VAC 1605VAC 500VAC IP 20 > 300 000 h 150x115x135 CE ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com ■ ■ CBI_Brochure_Final.pdf 10 3/21/14 4:53 PM CBI Series DC-UPS 24 VDC CBI243A 24VDC - 3A - 72W E353188 CBI245A 24VDC CBI243A 5A - 120W 24VDC - 3A - 72W 90 - 305 VAC 47 - 63 Hz ±6% 24VDC - 3A 90% 90 - 305 VAC 90 - 305 VAC 47 - 63 Hz ±6% 47 - 63 Hz ±6% 24VDC - 5A 24VDC - 3A 90% 90% ■ 1.1 x In A ± 5% 3A 6A 9A max 6A max M Y CM 28.8VDC 15h 1min. 27.6VDC 20 ÷ 100 % / Ibatt MY CY Boost / Trickle CMY K CBI2420A 24VDC - 10A - 240W 90 - 135 VAC 90 - 180 135 -VAC 305 VAC 180 - 305 VAC 47 - 63 Hz ±6% 47 - 63 Hz ±6% 24VDC - 20A 24VDC - 10A > 91% 83% 24VDC - 20A - 500W 90 - 135 VAC 90 - 180 135 -VAC 305 VAC 180 - 305 VAC 47 - 63 Hz ±6% 47 - 63 Hz ±6% 48VDC - 5A 24VDC - 20A 83% > 91% ■ ■ 48VDC - 5A - 240W 90 - 135 VAC 90 - 180 135 -VAC 305 VAC 180 - 305 VAC 47 - 63 Hz ±6% 47 - 63 Hz ±6% 48VDC - 10A 48VDC - 5A > 91% 83% ■ ■ ■ ■ ■ ■ ■ 22 - 28.8VDC 22 - 28.8VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 5A 3A 10A 6A 15A max 9A max 10A max 6A max 22 - 28.8VDC 22 - 28.8VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 10A 5A 20A 10A 30A max 15A max 20A max 10A max ■ CBI2410A/S 22 - 28.8VDC 22 - 28.8VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 20A 10A 40A 20A 60A max 30A max 40A max 20A max 44 - 57.6VDC 22 - 28.8VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 5A 20A 10A 40A 15A max 60A max 10A max 40A max ■ CBI485A/S 44 - 57.6VDC 44 - 57.6VDC 1.1 x In A ± 5% 1.1 x In A ± 5% 10A 5A 20A 10A 30A max 15A max 20A max 10A max ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ by ext. Probe by ext. Probe by ext. Probe by ext. Probe by ext. Probe -25 ÷ +70°C -25 ÷ +70°C -25 ÷ +70°C -25 ÷ +70°C -25 ÷ +70°C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C -40 ÷ +85°C -40 ÷ +85°C -40 ÷ +85°C -40 ÷ +85°C -40 ÷ +85°C 95% to 25°C 95% to 25°C 95% to 25°C 95% to 25°C 95% to 25°C Auto Convection Auto Convection Auto Convection Auto Convection Auto Convection 3000VAC 3000VAC 3000VAC 3000VAC 3000VAC 1605VAC 1605VAC 1605VAC 1605VAC 1605VAC 500VAC 500VAC 500VAC 500VAC 500VAC IP 20 IP 20 IP 20 IP 20 IP 20 > 300 000 h > 300 000 h > 300 000 h > 300 000 h > 300 000 h 65x115x135 65x115x135 100x115x135 65x115x135 65x115x135 CE /C-UL Recognized 60950 CE CE /C-UL Recognized 60950 CE /C-UL Recognized 60950 ■ ■ ■ by ext. Probe by ext. Probe - by ext. Probe by ext. Probe - by ext. Probe by ext. Probe - ■ -25 ÷ +70°C -25 ÷ +70°C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C -40 ÷ +85°C -40 ÷ +85°C 95% to 25°C 95% to 25°C Auto Convection Auto Convection 3000VAC 3000VAC 1605VAC 1605VAC 500VAC 500Vac IP 20 IP 20 > 300 000 h > 300 000 h 150x115x135 100x115x135 CE CE -25 ÷ +70°C -25 ÷ +70°C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C -40 ÷ +85°C -40 ÷ +85°C 95% to 25°C 95% to 25°C Auto Convection Auto Convection 3000VAC 3000VAC 1605VAC 1605VAC 500VAC 500VAC IP 20 IP 20 > 300 000 h > 300 000 h 100x115x135 150x115x135 CE CE - ■ 15h 1min. 55.2VDC 10 ÷ 100 % / Ibatt Boost / Trickle by ext. Probe -25 ÷ +70°C > 50° -2.5%(In) / °C -40 ÷ +85°C 95% to 25°C Auto Convection 3000VAC 1605VAC 500VAC IP 20 > 300 000 h 150x115x135 CE ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 57.6 ■ ■ ■ ■ ■ ■ ■ 20A max ■ ■ -25 ÷ +70°C -25 ÷ +70°C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C -40 ÷ +85°C -40 ÷ +85°C 95% to 25°C 95% to 25°C Auto Convection Auto Convection 3000VAC 3000VAC 1605VAC 1605VAC 500VAC 500VAC IP 20 IP 20 > 300 000 h > 300 000 h 150x115x135 100x115x135 CE CE ■ ■ 30A max ■ ■ ■ 20A ■ ■ ■ 10A ■ ■ - 1.1 x In A ± 5% ■ ■ ■ 44 - 57.6VDC ■ ■ CBI485A/S ■ ■ ■ 28.8VDC 28.8VDC 28.8VDC 57.6 57.6 28.8VDC 28.8VDC 28.8VDC 28.8VDC 57.6 15h 15h 15h 15h 15h 15h 15h 15h 15h 15h 1min. 1min. 1min. 1min. 1min. 1min. 1min. 1min. 1min. 1min. 27.6VDC 27.6VDC 27.6VDC 55.2VDC 55.2VDC 27.6VDC 27.6VDC 27.6VDC 27.6VDC 55.2VDC 20 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 20 ÷ 100 % / Ibatt 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel; 2.23NiCd V/cell1.5V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel; trickle (Imax 10%) NiCd 1.5V/cell trickle (Imax 10%) Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle Boost / Trickle IUoU, Automatic, 4 stage IUoU, Automatic, 4 stage - - ■ > 91% ■ ■ ■ CBI2410A/S 48VDC - 10A ■ ■ ■ 47 - 63 Hz ±6% ■ ■ ■ 90 - 135 VAC 180 - 305 VAC ■ ■ ■ 48VDC - 10A - 500W ■ ■ ■ ■ CBI4810A 48VDC - 10A - 500W CBI4810A CBI485A ■ ■ ■ ■ CBI485A 24VDC - 20A - 500W CBI2420A 48VDC - 5A - 240W CBI2410A ■ ■ - 47 - 63 Hz ±6% 47 - 63 Hz ±6% 24VDC - 10A 24VDC - 5A 83% 90% ■ ■ C 24VDC - 5A - 120W 90 - 135 VAC 305 V AC 90 - 180 305 -VAC ■ ■ ■ 22 - 28.8VDC E353188 CBI2410A 24VDC CBI245A 10A - 240W ■ ■ ■ 48 VDC ■ ■ ■ ■ ■ ■ Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com ■ 9 CBI_Brochure_Final.pdf 11 3/21/14 4:53 PM CBI Series DC-UPS In VAC 36/48 VDC 12/24 VDC 12/24 VDCdc Battery Mains or Backup Battery Low or Battery Replacement Out load CBI2803648A Model LOAD OUTPUT OUTPUT DATA INPUT DATA Output C MY CY BATTERY CHARGER OUTPUT CM CMY 12/24VDC - 270W Input voltage range 90 - 135 VAC 180 - 305 VAC 90 - 135 VAC 180 - 305 VAC 180 - 264 VAC 330 - 550 VAC Frequency 47 - 63 Hz ±6% 47 - 63 Hz ±6% 47 - 63 Hz ±6% Output VDC / IN 36 / 48VDC - 270 W 12 / 24VDC - 270 W 12 / 24VDC - 270 W Efficiency (50% of In) > 91% > 91% > 91% Over load and short-circuit protection ■ ■ ■ Overheating thermal protection ■ ■ ■ Reverse battery protection ■ ■ ■ Output voltage (at IN) VDC 33 - 43,2VDC / 44 - 57.6VDC 11 - 14.4VDC / 22 - 28.8VDC 11 - 14.4VDC / 22 - 28.8VDC Nominal current IN = Iload 1.1 x In A ± 5% 1.1 x In A ± 5% 1.1 x In A ± 5% Continuous current (without battery) Iload = In 7A (36V) / 5A (48V) 15A (12V) / 10A (24V) 15A (12V) / 10A (24V) Max current (with battery) Out: Iload = In + Ibatt 14A (36V) / 10A (48V) 30A (12V) / 20A (24V) 30A (12V) / 20A (24V) Max current: (main input) Out: Iload (4sec.) 21A (36V) / 15A (48V) 45A (12V) / 30A (24V) 45A (12V) / 30A (24V) Max current output load: (Back Up) Iload (4sec.) 14A (36V) / 10A (48V) 30A (12V) / 20A (24V) 30A (12V) / 20A (24V) Push button or remote input control ■ ■ ■ Time Buffering ■ ■ ■ Boost-Bulk charge (Typ. at IN) 43.2VDC (36V) / 57.6VDC (48V) 14.4 VDC (12V) / 28.8VDC (24V) 14.4 VDC (12V) / 28.8VDC (24V) Max. time boost-bulk charge (Typ. at IN) 15h 15h 15h Min. time boost-bulk charge (Typ. at IN) 1min. 1min. 1min. Trickle-Float charge (Typ. at IN) 41.4VDC (36V) / 55.2VDC (48V) 13.8 VDC (12V) / 27.6VDC (24V) 13.8 VDC (12V) / 27.6VDC (24V) Charging current Limiting IN (Iadj) 10 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 10 ÷ 100 % / Ibatt 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel; NiCd 1.5V/cell (20 elem.) trickle (Imax 10%) Jumper config. type battery (NiCd optional) Remote input control (AMP Type connector) K Boost / Trickle Boost / Trickle AUXILIARY SIGNAL OUTPUT* OUTPUT FOR: (RELAY) CLIMATIC DATA GENERAL DATA OPTIONAL Boost / Trickle IUoU, Automatic, 4 stage Characteristic Curve 10 CBI2801224B 12/24VDC - 270W M Y CBI2801224A 36/48VDC - 270W Main or backup power ■ ■ Low battery and fault battery ■ ■ ■ Temp. charging probe by ext. Probe by ext. Probe by ext. Probe UPS active - - - Modbus - CAN Bus ■ ■ ■ Ambient temperature operation -25 ÷ +70°C -25 ÷ +70°C -25 ÷ +70°C De rating Tª > (In) / De rating Tª > (In) > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C > 50° -2.5%(In) / °C Ambient temperature storage -40 ÷ +85°C -40 ÷ +85°C -40 ÷ +85°C ■ 95% to 25°C 95% to 25°C 95% to 25°C Cooling Auto Convection Auto Convection Auto Convection Isolation voltage (IN / OUT) 3000Vac 3000Vac 3000Vac Isolation voltage (IN / PE) 1605Vac 1605VAC 1605VAC Isolation voltage (OUT / PE) 500VAC 500VAC 500VAC Protection class (EN/IEC 60529) IP 20 IP 20 IP 20 Reliability (MTBF IEC 61709) > 300 000 h > 300 000 h > 300 000 h Dimension (w-h-d) 115x115x135 115x115x135 115x115x135 Safety standard approval CE CE CE Bar graph control panel ■ ■ ■ Graphic multifunction control panel ■ ■ ■ System monitoring software ■ ■ ■ System configuration software ■ ■ ■ Interface module modbus 485 - Ethernet ■ ■ ■ Interface module cloud all in one - Ethernet ■ ■ ■ Battery temp. compensation Probe RJTemp ■ ■ ■ Humidity at 25 °C Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com CBI_Brochure_Final.pdf 12 3/21/14 4:53 PM Battery Enclosures Small VRLA Compact and fully enclosed improve safety and maintenance, transmit information on the temperature and type of batteries. They save space and improve the efficiency of the DC UPS “All In One”.. Size for 24 VDC: 1.2 Ah, 3 Ah, 7.2 Ah and 12 Ah. 24 VDC BAT1.2 VRLA Model OUTPUT DATA INPUT DATA Output 24V - 1.2Ah BAT3.4 VRLA 24V - 7.2Ah BAT12 VRLA 24V - 12Ah 27.5 VDC (20°C) ; 27 VDC (30°C); 26.5 VDC (40°C) End-of-charge voltage (trickle charge) Max. permissible charging current 0.30 A 0.80 A 1.70 A Short-circuit protection ■ ■ ■ ■ Protection fuse 25 A 25 A 25 A 25 A Output current max. 25 A max. 25 A 3A max. 25 A max. 25 A DIN Rail / Wall Mount Mounting position for hanging onto M4 screws Assembly using 4 holes GENERIC DATA BAT7.2 VRLA 24V - 3.2Ah Ambient temperature (operation) 0 ÷ +40 °C 0 ÷ +40 °C 0 ÷ +40 °C 0 ÷ +40 °C Ambient temperature (storage) -20 ÷ +50 °C -20 ÷ +50 °C -20 ÷ +50 °C -20 ÷ +50 °C 20 °C 15% per month Self-discharge rate Dimension (w-h-d) 62 x 175 x 120 82 x 200 x 160 145 x 210 x130 210 x 210x210 Weight 1.5Kg approx 3 Kg approx 5.5 Kg approx. 9 Kg Protection class IP20 IP20 IP20 IP20 C M Y CM MY Battery Selection Chart CY CMY BUFFERING (MINUTE) TIME K Battery type 1.2 Ah 3.2 Ah 7.2 Ah 12 Ah Load 1.5 A 20 60 200 400 Load 3 A 8 30 120 240 Load 5 A 3 15 55 100 Load 7.5 A 2 10 30 60 Load 10 A - 7 20 45 Load 12 A - 3 12 30 Load 15 A - - 9 20 Load 20 A - - 7 13 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 11 CBI_Brochure_Final.pdf 13 3/21/14 4:53 PM CB Series Battery Chargers One device for all battery types Completely automatic, the battery chargers of the CB series are microprocessor controlled devices suited to charging most batteries types thank to factory pre-set and selectable charging curves. They can charge open lead acid, sealed lead acid, Gel and Ni-Cd, Ni-MH batteries. It is possible to change or add other charging curves connecting the device to a portable PC. Multi-Stage charging Three charging modes Automatic multi-stage operation and real time diagnostic allow fast recharge and recovery of deep discharged batteries, adding value and reliability to the system hosting the CB device. The type of charging it is Voltages stabilized and current stabilized IUoUo. CB battery chargers feature three charging modes, identified by a flashing code on a LED. Recovery charging Automatic multi-stage operation optimizes and adapt to battery status, even when the battery voltage is very low. CB can recharge batteries even when their voltage is close to zero. It allows recharge and complete recovery of flat batteries. Typical charging curve for recovery of batteries with voltage close to zero. • Boost (Boost - Bulk) (Blink 2/sec) • Trickle (also known as fl oat or maintenance charging) (Trickle - Float) (Blink 1/Sec.) • Recovery (Recovery) (Blink 5/sec.) Recovery (blink 5/sec.) Trickle - Float (blink 1/sec.) Jumper positions / VpC: Setting of battery maximum charging current The maximum battery charging current can be set from 20% to 100% of the device rated value. Not available on LC models. • Open Lead Acid: Trickle 2.23V Boost 2.40V • Sealed Lead Acid (1): Trickle 2.25V Boost 2.40V C M Y Boost - Bulk (blink 2/sec.) • Sealed Lead Acid (2): Trickle 2.27 Boost 2.40V CM MY Diagnosis • Gel: Trickle 2.30V Boost 2.40V CY CMY K • Optional: Ni/Cd Diagnosis Diagnosis Jumper for Battery Type Selection Diagnostic of battery and device All CB devices support the user during installation and operation. An LED flashing sequence code allows to discriminate among various possible faults. LED Diagnosis: • 1 flash Reverse polarity, wrong battery voltage. • 2 flashes Disconnected battery. • 3 flashes Battery element in short circuit. • 5 flashes Battery to be replaced (Internal impedance Bad or Bad battery wire connection). Diagnosis Diagnosis C 12 US Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 14 3/21/14 CB Series Battery Chargers Monitor signals Wide range input voltage Technology Flexibility is given also by the wide range input voltage. All the devices of the CB range accept input voltage in the range of 120 - 230 - 277 VAC. Only one device to stock! The CB series is a new range of battery chargers based on two strategic know-how elements. 120 VAC flexibility AC 0V 23 277 Signal contacts • CB chargers indicate battery status and faults also via a change-over contact with galvanic isolation. • Battery common fault. • Unit disconnected from mains. 4:53 PM VAC CBI_Brochure_Final.pdf Diagnostic checks C M Visual indication • Battery common fault • Unit disconnected from mains • Charging mode • CB device self-diagnostic Y CM Diagnosis • Check for accidental disconnection of the battery cables. If happen the devices switch off immediately the output power. • Battery not connected. If the battery it is not connected no output power. MY CY • Test of quality wire connections. During trickle charge the quality (resistance) on the battery connection is checked every 20 sec. This to detect if the cable connection has been properly made. CMY K Single output devices • Test of battery voltage connections. Appropriate voltage check, to prevent connection of wrong battery types. Diagnosis • End of charging check. When the battery it is completely full, the device automatically switch in trickle charging mode. • Reverse polarity check. If the battery it is connected with inverted polarity, the devices are automatically protected. Element in Short Circuit Switching technology We have over 25 year experience in design of advanced stabilized switching technology power supplies. A battery charger based on this technology is much more efficient and much smaller and lighter than traditional linear technology battery chargers. Micro-processor and Battery Care Unlike most other state-of-the-art battery chargers, the CB series is equipped with a micro-processor which controls the charging process and enables several monitoring functions. The firmware implements the extended battery care know-how, result of many years of experience in this field. Maximum safety and protection The CB series is designed to provide safe operation and long battery life. The following protections are standard features: • Output protected against short circuit and overload • Protection against deep battery discharge • Protection against reverse polarity connection • High insulation between primary and secondary • Detection of batteries with wrong rated voltage • Protection against the effect of parallel connection with other power sources, e.g. gensets. All protections have automatic reset. No thermal fuse to be replaced. Diagnosis Test and Diagnosis of the battery • Check for elements in short circuit. Thanks to specific algorithms of evaluation, the CBs recognize batteries with element in short circuit. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 13 CBI_Brochure_Final.pdf 15 3/21/14 4:53 PM CB Series Battery Chargers 12 VDC E353188 INPUT DATA 2xVAC OUTPUTS DATA CB123A CB126A CB1210A CB1235 A Input (Volt) VAC 115-230-277 115-230-277 115-230-277 115-230-277 Output (VDC - A - W) 12 - 3 - 36 12 - 6 - 72 12 - 10 - 120 12 - 35 - 420 Model CB123A CB126A CB1210A CB1235A Input Voltage Range VAC 90 - 264 90 - 264 90 - 264 90 - 135 / 180 - 264 Inrush Current (Vn and In Load) I2t (msec) ≤ 11 A ≤ 5 ≤ 11 A ≤ 5 ≤ 16 A ≤ 5 ≤ 35 A ≤ 5 Frequency 47 - 63 Hz ± 6% 47 - 63 Hz ± 6% 47 - 63 Hz ± 6% 47 - 63 Hz ± 6% Input Current (115 - 230 VAC) 0,5 - 0.3 A 1 - 0.7 A 2.4 - 1.2 A 8 - 4.2 A Internal Fuse 4A 4A 4A 10 A External Fuse (recommended) 10 A 10 A 10 A 16 A Output VDC / IN 12 VDC 3 A 12 VDC 6 A 12 VDC 10 A 12 VDC 35 A > 81% > 81% > 89% > 91% Boost - Bulk charge (Typ. at IN) 14.4 VDC 14.4 VDC 14.4 VDC 14.4 VDC Max.Time Boost-Bulk charge (Typ. at IN) 15 h 15 h 15 h 15 h Min.Time Boost-Bulk charge (Typ. at IN) 70 min. 70 min. 1 min. 1 min. Trickle-Float charge (Typ. at IN) 13.75 VDC 13.75 VDC 13.75 VDC 13.75 VDC Recovery Charge 2 - 7 VDC 2 - 7 VDC 2 - 9 VDC 2 - 9 VDC Charging max Ibatt 3 A ± 5% 6 A ± 5% 10 A ± 5% 35 A ± 5% Minimum load Efficiency (50% of IN) Short-circuit protection Over Load protection Over Voltage Out protection Reverse battery protection C M BATTERY CHARGER OUTPUT Y CM MY CY Charging current Limiting IN (Iadj) 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel Jumper Config. Type Battery CMY Quiescent Current K ≤ 5 mA ≤ 5 mA ≤ 5 mA IUoUo, Automatic 3 stage ≤ 5 mA Characteristic Curve SIGNAL OUTPUT (RELAY) Main or Backup Power Low Battery and Fault Battery Main or Backup - Fault Battery AUXILIARY RJ45 OUTPUT FOR: Temp. Charging probe CLIMATIC DATA Ambient Temperature (operation) -25 - +70 °C -25 - +70 °C -25 - +70 °C -25 - +70 °C De rating Tª > . (In) > 50° 2.5% > 40° 2.5% > 50° 2.5% > 50° 2.5% Voltage drop compensation Remote monitoring display > 40 °C Automatic De rating GENERAL DATA 14 Ambient Temperature Storage -40 - +85 °C -40 - +85 °C -40 - +85 °C -40 - +85 °C Humidity at 25 °C, no condensation 95% to 25 °C 95% to 25 °C 95% to 25 °C 95% to 25 °C Cooling Auto Convection Auto Convection Auto Convection Auto Convection Insulation Voltage (IN/OUT) 3000 VAC 3000 VAC 3000 VAC 3000 VAC Insulation Voltage (IN/PE) 1605 VAC 1605 VAC 1605 VAC 1605 VAC Insulation Voltage (OUT/PE) 500 VAC 500 VAC 500 VAC 500 VAC Protection Class (EN/IEC 60529) IP 20 IP 20 IP 20 IP 20 Reliability: MTBF IEC 61709 > 300 000 h > 300 000 h > 300 000 h > 300 000 h Pollution Degree Environment 2 2 2 2 Connection Terminal Blocks Screw Type 2,5 mm 2,5 mm 2,5 mm 4 mm Protection class (with PE connected) I I I I Dimension (w-h-d) 45x100x100 45x100x100 65x115x135 150x115x135 Weight 0.30 kg approx 0.30 kg approx 0.65 kg approx 1.5 kg approx Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com CBI_Brochure_Final.pdf 16 3/21/14 4:53 PM CB Series Battery Chargers 24 VDC 12/24 VDC E353188 E353241 CB243A CB245A CB2410A CB2420A 115-230-277 115-230-277 115-230-277 115-230-277 CB12245A 115-230-277 24 - 3 - 72 24 - 5 - 120 24 - 10 - 240 24 - 20 - 500 12/24 – 6/5 – 120 CB243A CB245A CB2410AC CB2420A CB12245A 90 - 264 90 - 264 90 - 135 / 180 - 264 90 - 135 / 180 - 264 90-305 ≤7A≤5 ≤ 16 A ≤ 5 ≤ 16 A ≤ 5 ≤ 35 A ≤ 5 81% > 89% Connection Diagram In VAC Battery Mains or Backup Battery Low or Battery Replacement CB123A, CB1210A 90% In VAC Battery Mains or Backup Battery Low or Battery Replacement C 28.8 VDC 28.8 VDC 28.8 VDC 28.8 VDC 14.4VDC / 28.8VDC M 15 h 15 h 15 h 15 h 15 h Y 70 min. 1 min. 1 min. 1 min. 4 min. 27.5 VDC 27.5 VDC 27.5 VDC 27.5 VDC 13.75 VDC / 27.5 VDC 2 - 16 VDC 2 - 18 VDC 2 - 18 VDC 2 - 18 VDC 2-7 / 2-16 VDC 3 A ± 5% 5 A ± 5% 10 A ± 5% 20 A ± 5% 6A / 5A ± 5% CM MY CB1235A In Battery Mains or Backup Battery Low or Battery Replacement CB243A, CY 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel CMY K ≤ 5 mA ≤ 5 mA ≤ 5 mA ≤ 5 mA ≤ 5 mA In VAC Battery IUoUo, Automatic, 3 stage Mains or Backup Battery Low or Battery Replacement CB245A, CB2410A, CB2420A -25 - +70 °C -25 - +70 °C -25 - +70 °C -25 - +70 °C -25 - +70 °C > 50° 2.5% > 50° 2.5% > 50° 2.5% > 50° 2.5% > 40° 2.5% -40 - +85 °C -40 - +85 °C -40 - +85 °C -40 - +85 °C -40 - +85 °C 95% to 25 °C 95% to 25 °C 95% to 25 °C 95% to 25 °C 95% to 25 °C Auto Convection Auto Convection Auto Convection Auto Convection Auto Convection 3000 VAC 3000 VAC 3000 VAC 3000 VAC 3000 VAC 1605 VAC 1605 VAC 1605 VAC 1605 VAC 1605 VAC 500 VAC 500 VAC 500 VAC 500 VAC 500 VAC IP 20 IP 20 IP 20 IP 20 IP 20 > 300 000 h > 300 000 h > 300 000 h > 300 000 h > 300 000 h 2 2 2 2,5 mm 2,5 mm 2,5 mm I I I 45x100x100 65x115x135 100x115x135 150x115x135 45x105x100 0.30 kg approx 0.65 kg approx 0.85 kg approx 1.55 kg approx 0.35 kg approx > 40 °C 2 4 mm I 2 2,5 mm I Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Optional for Auxiliary Output (RJ 45 connection) Temp. Charging probe: Temperature Sensor for battery 2 m length; Safety Standard Approval: CE. 15 CBI_Brochure_Final.pdf 1 3/21/14 4:53 PM C M Y CM MY CY CMY K Altech Corporation 35 Royal Road Flemington, NJ 08822-6000 P 908.806.9400 • F 908.806.9490 www.altechcorp.com Altech Corp.® CBICB-042014-3M Printed April 2014
CBI2410A 价格&库存

很抱歉,暂时无法提供与“CBI2410A”相匹配的价格&库存,您可以联系我们找货

免费人工找货
CBI2410A
    •  国内价格 香港价格
    • 1+7162.474451+841.14405

    库存:0