0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GFL2B050102

GFL2B050102

  • 厂商:

    ALTECH

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
GFL2B050102 数据手册
GFL Series - 1 Pole+N, B Trip, 10 mA 10kA UL489 Listed Branch Circuit Breaker with Equipment Ground Fault Protection (RCBO) The GFL Series range is a combined Branch Circuit Breaker and Equipment Ground Fault Protector, featuring dual pole switching (live and neutral disconnect) and designed to provide protection against short circuits, overloads, AC ground faults (residual current faults) as well as pulsating DC ground faults. C.B. W/EQ.GFP E483494 Rated Current Type/ Cat. No. Rated Voltage 5.0A GFL2B050102 240V AC 6.0A GFL2B060102 240V AC 8.0A GFL2B080102 240V AC 10A GFL2B100102 240V AC 7200 12A GFL2B120102 240V AC 3600 2400 13A GFL2B130102 240V AC 1200 15A GFL2B150102 240V AC 16A GFL2B160102 240V AC 20A GFL2B200102 240V AC 25A GFL2B250102 240V AC GFL Series RCBO Overload Trip Curves t(s) 120 Electrical Life Mechanical Life Dimensions 60 40 20 Technical Specification Number of Poles Voltage Rating (maximum) Ground Fault Sensitivity Level Rated Short Circuit Interrupt Capacity Rated Frequency Trip Characteristic Cable Size & Tightening Torque Characteristics B, C, D 600 480 360 240 Switch off time UL 489 Branch Circuit Breaker with Ground Fault Relay Ordering Information 10 5 1 0.5 1+N 240V AC 10 mA 10 kA 50/60Hz B Stranded Wire: 16 - 3 AWG (1.5 mm2 - 25 mm2) @ 17.5 lb-in (2.0 Nm) 16 - 10 AWG (1.5 mm2 - 5.5 mm2) @ 17.5 lb-in (2.0 Nm) Solid Wire: 18 - 16 AWG (1 mm2 - 1.5 mm2) @ 25 lb-in (2.8 Nm) 6000 Switching Operations 10000 Switching Operations 0.01 t(s) 105mm 35mm C D 1 1.05 1.35 2 3 4 5 6 7 8 9 10 Rated current multiple 12 14 16 18 20 x In GFL Series RCBO Ground Fault Trip Curve (to convert to inches multply by 0.03937) 45mm B 0.1 0.05 0.5 0.4 0.2 0.3 0.15 0.1 71mm 60mm 44mm 0.05 0.04 0.03 0.02 0.015 0.01 0.005 0.5 1 0.85 1.15 5 I∆ I∆n 17.5mm Weight 220 g 1 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com GFL Series - 1 Pole+N, B Trip, 10 mA Applicable voltage systems and wiring examples. GFL...2 L1 240 V 400 V 400 V L2 240 V 400 V 400Y/240V AC LOAD N 240 V L3 208 V 208 V UL 489 120 V Branch Circuit Breaker with Ground Fault Relay GFL...2 L1 L2 120 V 208 V 208Y/120V AC LOAD N 120 V L3 GFL...2 L2 120 V LOAD N 1 N N 2 120/240V AC 240 V LINE 120 V L1 GFL...2 N 2 1 N LINE 240 V N 120 V LOAD L2 NOTE: Wiring a hot leg/phase to N terminal is not permitted. 120 V L1 2 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com
GFL2B050102 价格&库存

很抱歉,暂时无法提供与“GFL2B050102”相匹配的价格&库存,您可以联系我们找货

免费人工找货