0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GFL2C12100SN

GFL2C12100SN

  • 厂商:

    ALTECH

  • 封装:

  • 描述:

    MCCB+EGFP 12A120240V AC 100MA C

  • 数据手册
  • 价格&库存
GFL2C12100SN 数据手册
GFL Series - 2 Pole + N, C Trip, 100 mA 10kA UL489 Listed Branch Circuit Breaker with Equipment Ground Fault Protection (RCBO) The GFL Series range is a combined Branch Circuit Breaker and Equipment Ground Fault Protector, featuring dual pole switching (live and neutral disconnect) and designed to provide protection against short circuits, overloads, AC ground faults (residual current faults) as well as pulsating DC ground faults. N 3 1 LINE C.B. W/EQ.GFP E483494 Ordering Information Type/ Cat. No. GFL2C05100SN GFL2C06100SN GFL2C08100SN GFL2C10100SN GFL2C12100SN GFL2C13100SN GFL2C15100SN GFL2C16100SN GFL2C20100SN GFL2C25100SN GFL2C30100SN GFL2C32100SN GFL2C35100SN GFL2C40100SN Rated Voltage 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC N 4 2 GFL Series RCBO Overload Trip Curves Characteris 7200 B, C, D 3600 2400 1200 600 480 360 240 120 t(s) UL 489 Branch Circuit Breaker with Ground Fault Relay Rated Current 5.0A 6.0A 8.0A 10A 12A 13A 15A 16A 20A 25A 30A 32A 35A 40A 60 40 20 10 Technical Specification Electrical Life Mechanical Life 5 2+N 120/240V AC 100 mA 10 kA 50/60Hz C Stranded Wire: 16 - 3 AWG (1.5 mm2 - 25 mm2) @ 17.5 lb-in (2.0 Nm) 16 - 10 AWG (1.5 mm2 - 5.5 mm2) @ 17.5 lb-in (2.0 Nm) Solid Wire: 18 - 16 AWG (1 mm2 - 1.5 mm2) @ 25 lb-in (2.8 Nm) 6000 Switching Operations 10000 Switching Operations Switch Number of Poles Voltage Rating (maximum) Ground Fault Sensitivity Level Rated Short Circuit Interrupt Capacity Rated Frequency Trip Characteristic Cable Size & Tightening Torque 1 0.5 C B 0.1 D 0.05 0.01 1 1.05 1.35 2 3 Rated current 4 5 6 7 8 9 10 12 14 16 18 20 xIn Dimensions (to convert to inches multply by 0.03937) GFL Series RCBO Ground Fault Trip Curve 105mm 45mm t(s) 53mm 0.5 0.4 0.2 0.3 0.15 71mm 60mm 44mm 0.1 0.05 0.04 0.03 0.02 0.015 0.01 0.005 Weight 0.5 1 0.85 1.15 5 I∆ I∆n 353 g 1 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com GFL Series - 2 Pole + N, C Trip, 100 mA Applicable voltage systems and wiring examples. GFL...SN UL 489 Branch Circuit Breaker with Ground Fault Relay L2 N 4 2 LINE 1 3 N LOAD 240 V N 120 V 120 V L1 L1 120 V N 4 2 LINE 3 1 N LOAD JUMPER from terminal 2 to N 240 V N 120 V No N Connection on Load L2 2 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com
GFL2C12100SN 价格&库存

很抱歉,暂时无法提供与“GFL2C12100SN”相匹配的价格&库存,您可以联系我们找货

免费人工找货