0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GFL2C160302

GFL2C160302

  • 厂商:

    ALTECH

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
GFL2C160302 数据手册
GFL Series - 1 Pole+N, C Trip, 30 mA 10kA UL489 Listed Branch Circuit Breaker with Equipment Ground Fault Protection (RCBO) The GFL Series range is a combined Branch Circuit Breaker and Equipment Ground Fault Protector, featuring dual pole switching (live and neutral disconnect) and designed to provide protection against short circuits, overloads, AC ground faults (residual current faults) as well as pulsating DC ground faults. C.B. W/EQ.GFP E483494 Rated Voltage 5.0A GFL2C050302 240V AC 6.0A GFL2C060302 240V AC 8.0A GFL2C080302 240V AC 10A GFL2C100302 240V AC 12A GFL2C120302 240V AC 13A GFL2C130302 240V AC 15A GFL2C150302 240V AC 16A GFL2C160302 240V AC 20A GFL2C200302 240V AC 25A GFL2C250302 240V AC GFL Series RCBO Overload Trip Curves 3600 2400 1200 600 480 360 240 120 Electrical Life Mechanical Life 60 40 20 Technical Specification Number of Poles Voltage Rating (maximum) Ground Fault Sensitivity Level Rated Short Circuit Interrupt Capacity Rated Frequency Trip Characteristic Cable Size & Tightening Torque Characteristics B, C, D 7200 t(s) Type/ Cat. No. time Rated Current Switch UL 489 Branch Circuit Breaker with Ground Fault Relay Ordering Information 1+N 240V AC 30 mA 10 kA 50/60Hz C Stranded Wire: 16 - 3 AWG (1.5 mm2 - 25 mm2) @ 17.5 lb-in (2.0 Nm) 16 - 10 AWG (1.5 mm2 - 5.5 mm2) @ 17.5 lb-in (2.0 Nm) Solid Wire: 18 - 16 AWG (1 mm2 - 1.5 mm2) @ 25 lb-in (2.8 Nm) 6000 Switching Operations 10000 Switching Operations 10 5 1 0.5 C B 0.1 D 0.05 0.01 2 1 1.05 1.35 Dimensions 3 4 5 6 Rated current multiple 7 8 9 10 12 14 16 18 20 xIn GFL Series RCBO Ground Fault Trip Curve (to convert to inches multply by 0.03937) 45mm 35mm t(s) 105mm 0.5 0.4 0.2 0.3 0.15 0.1 71mm 60mm 44mm 0.05 0.04 0.03 0.02 0.015 0.01 0.005 0.5 1 0.85 1.15 5 I∆ I∆n 17.5mm Weight 220 g 1 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com GFL Series - 1 Pole+N, C Trip, 30 mA Applicable voltage systems and wiring examples. GFL...2 L1 240 V 400 V 400 V L2 240 V 400 V 400Y/240V AC LOAD N 240 V L3 208 V 208 V UL 489 120 V Branch Circuit Breaker with Ground Fault Relay GFL...2 L1 L2 120 V 208 V 208Y/120V AC LOAD N 120 V L3 GFL...2 L2 120 V LOAD N 1 N N 2 120/240V AC 240 V LINE 120 V L1 GFL...2 N 2 1 N LINE 240 V N 120 V LOAD L2 NOTE: Wiring a hot leg/phase to N terminal is not permitted. 120 V L1 2 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com
GFL2C160302 价格&库存

很抱歉,暂时无法提供与“GFL2C160302”相匹配的价格&库存,您可以联系我们找货

免费人工找货